首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ObjectivesThis study sought to evaluate the optimal percutaneous coronary intervention techniques using drug-eluting stents for bifurcation coronary lesions.BackgroundThe optimal bifurcation stenting technique needs to be evaluated.MethodsThe trial included 2 randomization studies separated by the presence of side branch (SB) stenosis for patients having non–left main bifurcation lesions. For 306 patients without SB stenosis, the routine final kissing balloon or leave-alone approaches were compared. Another randomization study compared the crush or single-stent approaches for 419 patients with SB stenosis.ResultsBetween the routine final kissing balloon and leave-alone groups for nondiseased SB lesions, angiographic restenosis occurred in 17.9% versus 9.3% (p = 0.064), comprising 15.1% versus 3.7% for the main branch (p = 0.004) and 2.8% versus 5.6% for the SB (p = 0.50) from 214 patients (69.9%) receiving 8-month angiographic follow-up. Incidence of major adverse cardiac events including death, myocardial infarction, or target vessel revascularization over 1 year was 14.0% versus 11.6% between the routine final kissing balloon and leave-alone groups (p = 0.57). In another randomization study for diseased SB lesions, 28.2% in the single-stent group received SB stents. From 300 patients (71.6%) receiving angiographic follow-up, between the crush and single-stent groups, angiographic restenosis rate was 8.4% versus 11.0% (p = 0.44), comprising 5.2% versus 4.8% for the main branch (p = 0.90) and 3.9% versus 8.3% for the SB (p = 0.12). One-year major adverse cardiac events rate between the crush and single-stent groups was 17.9% versus 18.5% (p = 0.84).ConclusionsAngiographic and clinical outcomes were excellent after percutaneous coronary intervention using drug-eluting stents with any stent technique for non–left main bifurcation lesions once the procedure was performed successfully.  相似文献   

2.
ObjectivesThis study sought to evaluate the intravascular ultrasound (IVUS) minimal lumen area (MLA) for functionally significant left main coronary artery (LMCA) stenosis using fractional flow reserve (FFR) as the standard.BackgroundThe evaluation of significant LMCA stenosis remains challenging.MethodsWe identified 112 patients with isolated ostial and shaft intermediate LMCA stenosis (angiographic diameter stenosis of 30% to 80%) who underwent IVUS and FFR measurement.ResultsThe FFR was ≤0.80 in 66 LMCA lesions (59%); these exhibited smaller reference vessels, smaller minimal lumen diameter, greater diameter of stenosis, longer lesion length, smaller MLA, larger plaque burden, and more frequent plaque rupture. The independent factors of an FFR of ≤0.80 were plaque rupture (odds ratio [OR]: 4.47; 95% Confidence Interval (CI): 1.35 to 14.8; p = 0.014); body mass index (OR: 1.19; 95% CI: 1.00 to 1.41; p = 0.05), age (OR: 0.95; 95% CI: 0.90 to 1.00; p = 0.031), and IVUS MLA (OR: 0.37; 95% CI: 0.25 to 0.56; p < 0.001). The optimal IVUS MLA cutoff value for an FFR of ≤0.80 was 4.5 mm2 (77% sensitivity, 82% specificity, 84% positive predictive value, 75% negative predictive value, area under the curve: 0.83, 95% CI: 0.76 to 0.96; p < 0.001) overall and 4.1 to 4.5 mm2 in various subgroups. Adjustment for the body surface area, body mass index, and left ventricular mass did not improve the diagnostic accuracy of the IVUS MLA.ConclusionsIn patients with isolated ostial and shaft intermediate LMCA stenosis, an IVUS-derived MLA of ≤4.5 mm2 is a useful index of an FFR of ≤0.80.  相似文献   

3.
ObjectivesThis study sought to investigate the long-term comparative efficacy and safety of paclitaxel-eluting balloon (PEB), paclitaxel-eluting stent (PES), or balloon angioplasty (BA) for the treatment of drug-eluting stent restenosis.BackgroundThe optimal treatment of drug-eluting stent restenosis remains unknown. Although PEB has shown encouraging results, the long-term clinical efficacy and safety of PEB remains poorly defined.MethodsA total of 402 patients with clinically significant restenosis in limus-eluting stents were randomly assigned to receive PEB (n = 137), PES (n = 131), or BA (n = 134). For this analysis, PEB versus PES and PEB versus BA were compared. The primary efficacy and safety endpoints were target lesion revascularization and the composite of death or myocardial infarction.ResultsAt a median follow-up of 3 years, the risk of target lesion revascularization was comparable with PEB versus PES (hazard ratio [HR]: 1.46, 95% confidence interval [CI]: 0.91 to 2.33; p = 0.11) and lower with PEB versus BA (HR: 0.51, 95% CI: 0.34 to 0.74; p < 0.001). The risk of death/myocardial infarction tended to be lower with PEB versus PES (HR: 0.55, 95% CI: 0.28 to 1.07; p = 0.08), due to a lower risk of death (HR: 0.38, 95% CI: 0.17 to 0.87; p = 0.02). The risk of death/myocardial infarction was similar with PEB versus BA (HR: 0.96, 95% CI: 0.46 to 2.0; p = 0.91).ConclusionsAt 3 years, the use of PEB as compared with PES to treat patients with limus-eluting stent restenosis has similar efficacy and safety. PEB remains superior to BA. The sustained efficacy without trade-off in safety supports the role of PEB as treatment option for patients with drug-eluting stent restenosis. (Intracoronary Stenting and Angiographic Results: Drug Eluting Stent In-Stent Restenosis: 3 Treatment Approaches [ISAR-DESIRE 3]; NCT00987324)  相似文献   

4.
ObjectivesThis study sought to assess the incidence and clinical impact of stent fracture (SF) after the PROMUS Element platinum-chromium everolimus-eluting stent (PtCr-EES).BackgroundSF remains an unresolved, clinically relevant issue, even in the newer-generation drug-eluting stent era.MethodsFrom March 2012 to August 2013, 816 patients with 1,094 lesions were treated only with PtCr-EES and 700 patients (85.7%) with 898 lesions undergoing follow-up angiography within 9 months after the index procedure were analyzed. SF was defined as complete or partial separation of the stent, as assessed by plain fluoroscopy, intravascular ultrasound, or optical coherence tomography during the follow-up. We assessed the rate of SF and the cumulative incidence of clinically driven target lesion revascularization and definite stent thrombosis within 9 months after the index procedure.ResultsSF was observed in 16 of 898 lesions (1.7%) and 16 of 700 patients (2.2%). Lesions with in-stent restenosis at baseline (odds ratio [OR]: 14.2, 95% confidence intervals [CI]: 5.09 to 39.7; p < 0.001) or hinge motion (OR: 4.31, 95% CI: 1.12 to 16.5; p = 0.03), and total stent length (per 10-mm increase; OR: 1.32, 95% CI: 1.12 to 1.57; p = 0.001) were predictors of SF. Cumulative incidence of clinically driven target lesion revascularization within 9-months was numerically higher in the SF group than that in the non-SF group (18.7% vs. 2.3%). Cumulative incidence of definite stent thrombosis within 9 months after the index procedure was similar between the SF and non-SF groups (0.0% vs. 0.23%).ConclusionsSF after PtCr-EES occurs in 1.7% of lesions and appears to be associated with clinically driven target lesion revascularization.  相似文献   

5.
ObjectivesThe present study established criteria to differentiate simple from complex bifurcation lesions and compared 1-year outcomes stratified by lesion complexity after provisional stenting (PS) and 2-stent techniques using drug-eluting stents.BackgroundCurrently, no criterion can distinguish between simple and complex coronary bifurcation lesions. Comparisons of PS and 2-stent strategies stratified by lesion complexity have also not been reported previously.MethodsCriteria of bifurcation complexity in 1,500 patients were externally tested in another 3,660 true bifurcation lesions after placement of drug-eluting stents. The primary endpoint was the occurrence of a major adverse cardiac event (MACE) at 12 months. The secondary endpoint was the rate of stent thrombosis (ST).ResultsComplex (n = 1,108) bifurcation lesions were associated with a higher 1-year rate of MACE (16.8%) compared with simple (n = 2,552) bifurcation lesions (8.9%) (p < 0.001). The in-hospital ST and 1-year target lesion revascularization rates after 2-stent techniques in the simple group (1.0% and 5.6%, respectively) were significantly different from those after PS (0.2% [p = 0.007] and 3.2% [p = 0.009], respectively); however, 1-year MACE rates were not significantly different between the 2 groups. For complex bifurcation lesions, 2-stent techniques had lower rates of 1-year cardiac death (2.8%) and in-hospital MACE (5.0%) compared with PS (5.3%, p = 0.047; 8.4%, p = 0.031).ConclusionsComplex bifurcation lesions had higher rates of 1-year MACE and ST. The 2-stent and PS techniques were overall equivalent in 1-year MACE. However, 2-stent techniques for complex lesions elicited a lower rate of cardiac death and in-hospital MACE but higher rates of in-hospital ST and revascularization at 1 year for simple lesions.  相似文献   

6.
ObjectivesThis study sought to compare the outcomes of fractional flow reserve (FFR)–guided and angiography (Angio)–guided provisional side-branch (SB) stenting for true coronary bifurcation lesions.BackgroundAngio-guided provisional SB stenting after stenting of the main vessel provides favorable outcomes for the majority of coronary bifurcation lesions. Whether an FFR-guided provisional stenting approach is superior has not been studied.MethodsA total of 320 patients with single Medina 1,1,1 and 0,1,1 coronary bifurcation lesions undergoing stenting with a provisional SB approach were randomly assigned 1:1 to Angio-guided and FFR-guided groups. SB stenting was performed for Thrombolysis In Myocardial Infarction flow grade <3, ostial SB stenosis >70%, or greater than type A dissection after main vessel stenting in the Angio-guided group and for SB-FFR <0.80 in the FFR-guided group. The primary endpoint was the 1-year composite rate of major adverse cardiac events (cardiac death, myocardial infarction, and clinically driven target vessel revascularization).ResultsComparing the Angio-guided and FFR-guided groups, treatment of the SB (balloon or stenting) was performed in 63.1% and 56.3% of lesions respectively (p = 0.07); stenting of the SB was attempted in 38.1% and 25.9%, respectively (p = 0.01); and, when attempted, stenting was successful in 83.6% and 73.3% of SBs, respectively (p = 0.01). The 1-year composite major adverse cardiac event rate was 18.1% in both groups (hazard ratio: 0.91, 95% confidence interval: 0.48 to 1.88; p = 1.00). The 1-year target vessel revascularization and stent thrombosis rates were 6.9% and 5.6% (p = 0.82) and 1.3% and 0.6% (p = 0.56) in the Angio-guided and FFR-guided groups, respectively.ConclusionsIn this multicenter, randomized trial, angiographic and FFR guidance of provisional SB stenting of true coronary bifurcation lesions provided similar 1-year clinical outcomes. (Randomized Study on DK Crush Technique Versus Provisional Stenting Technique for Coronary Artery Bifurcation Lesions; ChiCTR-TRC-07000015)  相似文献   

7.
ObjectivesThis study aimed to investigate the clinical outcomes of patients presenting with recurrent drug-eluting stent (DES) in-stent restenosis (ISR) treated with a second-generation DES or with a drug-coated balloon (DCB).BackgroundTo date, there are no reports of DCB treatment and limited data with regard to the efficacy of further DES implantation for recurrent ISR.MethodsBetween January 2008 and December 2013, 171 lesions were assessed for eligibility (82 lesions in the second-generation DES group and 89 lesions in the DCB group).ResultsAcute gain was greater in the second-generation DES group (second-generation DES, 2.09 ± 0.53 mm vs. DCBs, 1.60 ± 0.62 mm, p < 0.001). The rates of major adverse cardiac events were comparable (at 1 year, DES 14.0% vs. DCBs 12.3%; at 2 years, DES 28.8% vs. DCBs 43.5%, p = 0.21). Major adverse cardiac event rates were mainly driven by target lesion revascularization (at 1 year, DES 12.5% vs. DCBs 10.9%; at 2 years, DES 27.7% vs. DCBs 38.3%; p = 0.40). Definite scaffold thrombosis occurred in 2 patients (1 patient in each group). Multivariable analysis revealed ISR recurrence within 1 year (hazard ratio: 2.43, 95% confidence interval: 1.14 to 5.18, p = 0.02) and lesion length (per 10-mm increase) (hazard ratio: 1.15, 95% confidence interval: 1.00 to 1.32, p = 0.049) to be independent predictors of TLR.ConclusionsThe results after both treatments were equivalent. ISR recurrence within 1 year of the first reintervention and lesion length were independent predictors of future target lesion revascularization. Larger studies are required to confirm the late (>1 year) differences with regard to clinical outcomes.  相似文献   

8.
ObjectivesThis study sought to evaluate procedural and clinical outcomes among patients undergoing chronic total occlusion (CTO) percutaneous coronary intervention (PCI) using contemporary methods and everolimus-eluting stents (EES).BackgroundLimited studies have detailed the procedural and late-term safety and efficacy of CTO revascularization among multiple centers applying modern techniques and with newer-generation drug-eluting stents.MethodsAmong 20 centers, 250 consecutive patients were enrolled for attempted CTO PCI. Procedural and in-hospital clinical outcomes were examined in addition to the 1-year primary endpoint of death, myocardial infarction, and target lesion revascularization (major adverse cardiac events [MACE]).ResultsDemographic, lesion, and procedural characteristics included prior bypass surgery: 9.9%; diabetes: 40.1%; lesion length: 36.1 ± 18.5 mm; and stent length: 51.7 ± 27.2 mm. Procedural success, defined as guidewire recanalization with no in-hospital MACE, was 96.4%. Success with antegrade-only methods was 97.9% and 86.2% by retrograde/combined methods, respectively. Compared with a pre-specified performance goal derived from 6 prior CTO drug-eluting stent trials (1-year MACE: 24.4%), treatment with EES was associated with significantly lower composite adverse events for both intent-to-treat (18.5%, 1-sided upper confidence interval: 23.4%, p = 0.025) and per-protocol populations (8.2%, 1-sided upper confidence interval: 12.3%, p < 0.0001). Target lesion revascularization at 1 year was 6.3%. Dual antiplatelet therapy adherence was 53.9% at 1 year, yet subacute definite stent thrombosis occurred in only 2 patients (0.9%), and late probable stent thrombosis occurred in 1 patient (0.5%).ConclusionsIn a multicenter registration trial representing contemporary technique and EES, favorable procedural success and late-term clinical outcomes support CTO PCI in a patient population with high lesion complexity. (EXPERT CTO: Evaluation of the XIENCE PRIME LL and XIENCE Nano Everolimus Eluting Coronary Stent Coronary Stents, Performance, and Technique in Chronic Total Occlusions; NCT01435031)  相似文献   

9.
ObjectivesThe aim of the current study was to compare everolimus-eluting stents (EES) with sirolimus-eluting stents (SES) in patients undergoing primary angioplasty.BackgroundDrug-eluting stents may offer benefits in terms of repeat revascularization. However, as shown for first-generation drug-eluting stents, they may be counterbalanced by a potential higher risk of stent thrombosis, especially among patients with ST-segment elevation myocardial infarction (STEMI). No data have been reported so far on the long-term benefits and safety of the new generation of drug-eluting stents in STEMI.MethodsConsecutive STEMI patients admitted within 12 h of symptom onset and undergoing primary angioplasty and stent implantation at a tertiary center with 24-h primary percutaneous coronary intervention capability were randomly assigned to SES or EES. The primary endpoint was a major adverse cardiac event at 3-year follow-up. The secondary endpoints were death, reinfarction, definite or probable stent thrombosis, and target vessel revascularization at 3-year follow-up. No patient was lost to follow-up.ResultsFrom April 2007 to May 2009, 500 patients with STEMI were randomized to EES (n = 250) or SES (n = 250). No difference was observed in terms of baseline demographic and clinical characteristics between the groups. No difference was observed between the groups in terms of number of implanted stents per patient or total stent length. However, a larger reference diameter was observed with SES (3.35 ± 0.51 mm vs. 3.25 ± 0.51 mm, p = 0.001), whereas patients randomized to EES more often received glycoprotein IIb/IIIa inhibitors (54.4% vs. 42.4%, p = 0.006). Follow-up data were available in all patients (1,095 ± 159 days). No significant difference was observed between EES and SES in major adverse cardiac events (16% vs. 20.8%, adjusted hazard ratio [HR]: 0.75 [95% confidence interval (CI): 0.5 to 1.13], p = 0.17), cardiac death (4.4% vs. 5.6%, adjusted HR: 0.77 [95% CI: 0.35 to 1.71], p = 0.53), recurrent MI (6.4% vs. 10%, adjusted HR: 0.62 [95% CI: 0.33 to 1.16], p = 0.13), and target vessel revascularization (4.8% vs. 4.8%, adjusted HR: 1.00 [95% CI: 0.45 to 2.32], p = 0.99). However, EES was associated with a significant reduction in stent thrombosis (1.6% vs. 5.2%, adjusted HR: 0.3 [95% CI: 0.1 to 0.92], p = 0.035).ConclusionsThis study shows that among STEMI patients undergoing primary angioplasty, EES has similar efficacy as SES, but is associated with a significant reduction in stent thrombosis. (Randomized Comparison of Everolimus Eluting Stents and Sirolimus Eluting Stent in Patients With ST Elevation Myocardial Infarction [RACES-MI]; NCT01684982)  相似文献   

10.
ObjectivesThis study sought to compare the outcomes of spot stenting versus long stenting after intentional subintimal approach for long femoropopliteal chronic total occlusions (CTO).BackgroundThe optimal stenting strategy following the subintimal recanalization of long femoropopliteal chronic total occlusions has not been investigated.MethodsA total of 196 limbs in 163 patients, implanted with bare nitinol stents after subintimal approach in long femoropopliteal occlusions (lesion length 25 ± 8 cm), were retrospectively analyzed. The primary patency was compared between spot stenting (n = 129) and long stenting (n = 67).ResultsBaseline characteristics and immediate procedural results were similar between groups. Adjusted-primary patency (47% vs. 77%, p < 0.001) and adjusted-freedom from target lesion revascularization (52% vs. 84%, p < 0.001) at 2 years were significantly lower in the long stenting group than in the spot stenting group. The incidence of stent fracture, fracture type, and restenosis pattern did not differ between groups. Long stenting was an independent predictor of restenosis (hazard ratio [HR]: 2.0) along with other risk factors such as nonuse of clopidogrel (HR: 3.3) or cilostazol (HR: 2.2), small stent diameter (HR: 0.6), poor run-off (HR: 1.9), and post-procedural ankle-brachial index (HR: 0.1). Compared with spot stenting after adjustment using inverse probability of treatment weighting, long stenting, especially involving the P2 or P3 segment of the popliteal artery, was independently associated with 7.5-fold increases in restenosis risk (p < 0.001).ConclusionsThe primary patency was significantly higher with spot stenting than with long stenting following subintimal approach for long femoropopliteal chronic total occlusions. The risk of restenosis was especially higher when long stenting was extended to the distal popliteal artery.  相似文献   

11.
ObjectivesThis study sought to compare the effect of paclitaxel-coated balloon (PCB) concentration on tissue levels and vascular healing using 3 different PCB technologies (In.Pact Pacific = 3 μg/mm2, Lutonix = 2 μg/mm2 and Ranger = 2 μg/mm2) in the experimental setting.BackgroundThe optimal therapeutic dose for PCB use has not been determined yet.MethodsPaclitaxel tissue levels were measured up to 60 days following PCB inflation (Ranger and In.Pact Pacific) in the superficial femoral artery of healthy swine (18 swine, 36 vessels). The familial hypercholesterolemic swine model of superficial femoral artery in-stent restenosis (6 swine, 24 vessels) was used in the efficacy study. Two weeks following bare-metal stent implantation, each in-stent restenosis site was randomly treated with a PCB or an uncoated control balloon (Sterling). Quantitative vascular analysis and histology evaluation was performed 28 days following PCB treatment.ResultsAll PCB technologies displayed comparable paclitaxel tissue levels 4 h following balloon inflation. At 28 days, all PCB had achieved therapeutic tissue levels; however, the In.Pact PCB resulted in higher tissue concentrations than did the other PCB groups at all time points. Neointimal inhibition by histology was decreased in all PCB groups compared with the control group, with a greater decrease in the In.Pact group. However, the neointima was more mature and contained less peri-strut fibrin deposits in both 2-μg/mm2 PCB groups.ConclusionsCompared with the clinically established PCB dose, lower-dose PCB technologies achieve lower long-term tissue levels but comparable degrees of neointimal inhibition and fewer fibrin deposits. The impact of these findings in restenosis reduction and clinical outcomes needs to be further investigated.  相似文献   

12.
ObjectivesThe purpose of this study was to evaluate 15-year patency and life expectancy after endovascular treatment (EVT) with primary stenting guided by intravascular ultrasound (IVUS) for iliac artery lesions.BackgroundFifteen-year patency, factors causing restenosis, and survival after IVUS-guided EVT are unclear based on the TransAtlantic Inter-Society Consensus II (TASC-II) classification in peripheral arterial disease (PAD).MethodsEVT was performed for 507 lesions in 455 patients with PAD. The 15-year endpoints were primary, primary-assisted, and secondary patency; overall survival; freedom from major adverse cardiovascular events (MACE); and freedom from major adverse cardiovascular and limb events (MACLE).ResultsThe 5-, 10-, and 15-year primary and secondary patencies were 89%, 83%, and 75%, respectively, and 92%, 91%, and 91%, respectively. There were no significant differences among TASC-II categories.ConclusionsIVUS-guided stenting for the iliac artery had favorable 15-year patency in all TASC categories. Life expectancy after EVT was poor, but stenting is feasible for patients with PAD.  相似文献   

13.
ObjectivesThis study aimed to assess the clinical impact of strut width (evaluated by abluminal strut surface area [ASSA]) on periprocedural myocardial infarction (PMI) and clinical outcomes in patients treated with bioresorbable scaffolds (BRS) versus first-generation sirolimus-eluting stents (SES).BackgroundTo date, there are no reports on the impact of ASSA on PMI and clinical outcomes.MethodsWe compared the impact of ASSA on outcomes and PMI in propensity-matched patients treated with BRS and SES. The primary outcome was the incidence of major adverse cardiac events (MACE), defined as the combination of all-cause mortality, follow-up myocardial infarction, and target vessel revascularization, at 30-days and 1-year follow-ups. The secondary endpoint was the incidence of PMI.ResultsAfter propensity-matched analysis, 499 patients (147 BRS patients vs. 352 SES patients) were evaluated. Mean ASSA was higher in patients treated with BRS versus SES (BRS: 132.3 ± 76.7 mm2 vs. SES: 67.6 ± 48.4 mm2, p < 0.001). MACE was not significantly different between groups (30-days MACE: BRS: 0% vs. SES: 1.4%, p = 0.16, and 1-year MACE: BRS: 15.7% vs. SES: 11.4%, p = 0.67). The incidence of PMI was significantly higher in the BRS group (BRS: 13.1% vs. SES: 7.5%, p = 0.05). Multivariable analyses indicated that treatment of left anterior descending artery and ASSA were independent predictors of PMI.ConclusionsBRS implantation, compared with SES implantation, was associated with a higher incidence of PMI. MACE at 30 days and 1 year were not significantly different. Left anterior descending artery percutaneous coronary intervention and ASSA were independent predictors of PMI.  相似文献   

14.
ObjectivesMAVERIC (Mitral Valve Repair Clinical Trial) reports the safety and efficacy of the ARTO system in patients with symptomatic heart failure and functional mitral regurgitation (FMR).BackgroundThe ARTO system percutaneously modifies the mitral annulus to improve leaflet coaptation in FMR.MethodsThe MAVERIC trial is a prospective, nonrandomized first-in-human study. Key inclusion criteria were systolic heart failure New York Heart Association functional classes II to IV, FMR grade ≥2+, left ventricular (LV) ejection fraction ≤40%, LV end-diastolic diameter >50 mm and ≤75 mm. Exclusion criteria were clinical variables that precluded feasibility of the ARTO procedure. Primary outcomes were safety (30-day major adverse events) and efficacy (MR reduction, LV volumes, and functional status).ResultsEleven patients received the ARTO system, and there were no procedural adverse events. From baseline to 30 days, there were meaningful improvements. Effective regurgitant orifice area decreased from 30.3 ± 11.1 mm2 to 13.5 ± 7.1 mm2 and regurgitant volumes from 45.4 ± 15.0 ml to 19.5 ± 10.2 ml. LV end-systolic volume index improved from 77.5 ± 24.3 ml/m2 to 68.5 ± 21.4 ml/m2, and LV end-diastolic volume index 118.7 ± 28.6 ml/m2 to 103.9 ± 21.2 ml/m2. Mitral annular anteroposterior diameter decreased from 45.0 ± 3.3 mm to 38.7 ± 3.0 mm. Functional status was 81.8% New York Heart Association functional class III/IV improving to 54.6% functional class I/II. At 30 days, there were 2 adverse events: 1 pericardial effusion requiring surgical drainage; and 1 asymptomatic device dislodgement.ConclusionsThe ARTO system is a novel transcatheter device that can be used safely with meaningful efficacy in the treatment of FMR. (Mitral Valve Repair Clinical Trial [MAVERIC]; NCT02302872)  相似文献   

15.
ObjectivesThe purpose of this study was to compare the 2-year safety and effectiveness of new- versus early-generation drug-eluting stents (DES) according to the severity of coronary artery disease (CAD) as assessed by the SYNTAX (Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery) score.BackgroundNew-generation DES are considered the standard-of-care in patients with CAD undergoing percutaneous coronary intervention. However, there are few data investigating the effects of new- over early-generation DES according to the anatomic complexity of CAD.MethodsPatient-level data from 4 contemporary, all-comers trials were pooled. The primary device-oriented clinical endpoint was the composite of cardiac death, myocardial infarction, or ischemia-driven target-lesion revascularization (TLR). The principal effectiveness and safety endpoints were TLR and definite stent thrombosis (ST), respectively. Adjusted hazard ratios (HRs) with 95% confidence intervals (CIs) were calculated at 2 years for overall comparisons, as well as stratified for patients with lower (SYNTAX score ≤11) and higher complexity (SYNTAX score >11).ResultsA total of 6,081 patients were included in the study. New-generation DES (n = 4,554) compared with early-generation DES (n = 1,527) reduced the primary endpoint (HR: 0.75 [95% CI: 0.63 to 0.89]; p = 0.001) without interaction (p = 0.219) between patients with lower (HR: 0.86 [95% CI: 0.64 to 1.16]; p = 0.322) versus higher CAD complexity (HR: 0.68 [95% CI: 0.54 to 0.85]; p = 0.001). In patients with SYNTAX score >11, new-generation DES significantly reduced TLR (HR: 0.36 [95% CI: 0.26 to 0.51]; p < 0.001) and definite ST (HR: 0.28 [95% CI: 0.15 to 0.55]; p < 0.001) to a greater extent than in the low-complexity group (TLR pint = 0.059; ST pint = 0.013). New-generation DES decreased the risk of cardiac mortality in patients with SYNTAX score >11 (HR: 0.45 [95% CI: 0.27 to 0.76]; p = 0.003) but not in patients with SYNTAX score ≤11 (pint = 0.042).ConclusionsNew-generation DES improve clinical outcomes compared with early-generation DES, with a greater safety and effectiveness in patients with SYNTAX score >11.  相似文献   

16.
ObjectivesThis study aimed to investigate the characteristics of neoatherosclerosis (NA) in patients with diabetes mellitus (DM) after drug-eluting stent (DES) implantation using optical coherence tomography.BackgroundNA is an important substrate for stent failure. In vivo NA characteristics in DM patients have not been investigated.MethodsA total of 397 patients with 452 DES who underwent follow-up optical coherence tomography examination after DES implantation were enrolled. Characteristics of NA were compared between DM and non-DM patients. Neovascularization was defined as signal-poor holes or tubular structures with a diameter of 50 to 300 μm.ResultsA total of 123 DES with NA lesions in 115 patients were identified. The incidence of NA was similar between DM and non-DM patients (29.6% vs. 28.6%; p = 0.825). Compared with the non-DM group, neovascularization was more frequently observed in the DM group (55.1% vs. 32.4%; p = 0.012). The multivariate logistic model demonstrated that DM (odds ratio: 3.00; 95% confidence interval: 1.31 to 6.81; p = 0.009) and follow-up duration (odds ratio: 1.03; 95% confidence interval: 1.02 to 1.05; p < 0.001) were the independent predictors for neovascularization in NA lesions. DM patients with glycated hemoglobin ≥7.0% had a higher prevalence of thin-cap fibroatheroma compared with those with glycated hemoglobin <7.0% (40.0% vs. 8.3%; p = 0.01).ConclusionsThe incidence of NA was similar between patients with and without DM. Neovascularization in NA lesions was more frequent in those with DM. Poorly controlled DM patients had a higher incidence of thin-cap fibroatheroma, compared with those with well-controlled DM.  相似文献   

17.
ObjectivesThe intention this PEPCAD-DES (Treatment of Drug-eluting Stent [DES] In-Stent Restenosis With SeQuent Please Paclitaxel Eluting Percutaneous Transluminal Coronary Angioplasty [PTCA] Catheter) study update was to demonstrate the safety and efficacy of paclitaxel-coated balloon (PCB) angioplasty in patients with DES-ISR at 3 years.BackgroundIn the PEPCAD-DES trial late lumen loss and the need for repeat target lesion revascularization (TLR) was significantly reduced with PCB angioplasty compared with plain old balloon angioplasty (POBA) in patients with drug-eluting stent in-stent restenosis (DES-ISR) at 6 months. We evaluated whether the clinical benefit of reduced TLR and major adverse cardiac events (MACE) was maintained up to 3 years.MethodsA total of 110 patients with DES-ISR in native coronary arteries with reference diameters ranging from 2.5 mm to 3.5 mm and lesion lengths ≤22 mm were randomized to treatment with either PCB or POBA in a multicenter, randomized, single-blind clinical study. With a 2:1 randomization, 72 patients were randomized to the PCB group and 38 patients to the POBA group. At baseline, there were lesions with at least 2 stent layers in PCB (52.8%, 38 of 72) and POBA (55.3%, 21 of 38) patients.ResultsAt 36 months, the TLR rates were significantly lower in the PCB group compared with the POBA control group (19.4% vs. 36.8%; p = 0.046). Multiple TLRs in individual patients were more frequent in the POBA group compared with the PCB group (more than 1 TLR: POBA, 13.2%; PCB, 1.4%; p = 0.021). The 36-month MACE rate was significantly reduced in the PCB group compared with the POBA group (20.8% vs. 52.6%, log-rank p = 0.001).ConclusionsPCB angioplasty was superior to POBA for the treatment of DES-ISR patients in terms of MACE and TLR for up to 36 months. There was no late catch-up phenomenon. (Treatment of Drug-eluting Stent [DES] In-Stent Restenosis With SeQuent® Please Paclitaxel Eluting Percutaneous Transluminal Coronary Angioplasty [PTCA] Catheter [PEPCAD-DES]; NCT00998439)  相似文献   

18.
ObjectivesThis study used a fractal bifurcation bench model to compare 6 optimization sequences for coronary bifurcation provisional stenting, including 1 novel sequence without kissing balloon inflation (KBI), comprising initial proximal optimizing technique (POT) + side-branch inflation (SBI) + final POT, called “re-POT.”BackgroundIn provisional bifurcation stenting, KBI fails to improve the rate of major adverse cardiac events. Proximal geometric deformation increases the rate of in-stent restenosis and target lesion revascularization.MethodsA bifurcation bench model was used to compare KBI alone, KBI after POT, KBI with asymmetric inflation pressure after POT, and 2 sequences without KBI: initial POT plus SBI, and initial POT plus SBI with final POT (called “re-POT”). For each protocol, 5 stents were tested using 2 different drug-eluting stent designs: that is, a total of 60 tests.ResultsCompared with the classic KBI-only sequence and those associating POT with modified KBI, the re-POT sequence gave significantly (p < 0.05) better geometric results: it reduced SB ostium stent-strut obstruction from 23.2 ± 6.0% to 5.6 ± 8.3%, provided perfect proximal stent apposition with almost perfect circularity (ellipticity index reduced from 1.23 ± 0.02 to 1.04 ± 0.01), reduced proximal area overstretch from 24.2 ± 7.6% to 8.0 ± 0.4%, and reduced global strut malapposition from 40 ± 6.2% to 2.6 ± 1.4%.ConclusionsIn comparison with 5 other techniques, the re-POT sequence significantly optimized the final result of provisional coronary bifurcation stenting, maintaining circular geometry while significantly reducing SB ostium strut obstruction and global strut malapposition. These experimental findings confirm that provisional stenting may be optimized more effectively without KBI using re-POT.  相似文献   

19.
Treatment of coronary bifurcation lesions remains an ongoing challenge for interventional cardiologists. Stenting of coronary bifurcations carries higher risk for in-stent restenosis, stent thrombosis, and recurrent clinical events. This review summarizes the current evidence regarding application and use of biomechanical modeling in the study of stent properties, local flow dynamics, and outcomes after percutaneous coronary interventions in bifurcation lesions. Biomechanical modeling of bifurcation stenting involves computational simulations and in vitro bench testing using subject-specific arterial geometries obtained from in vivo imaging. Biomechanical modeling has the potential to optimize stenting strategies and stent design, thereby reducing adverse outcomes. Large-scale clinical studies are needed to establish the translation of pre-clinical findings to the clinical arena.  相似文献   

20.
ObjectivesThis study sought to report the 5-year outcomes of everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES) in an all-comers population undergoing percutaneous coronary intervention (PCI).BackgroundThe medium-term 1 and 2-year results of the prospective randomized COMPARE trial (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) showed superior clinical outcomes with EES compared with PES in an all-comers PCI population. Whether this benefit is sustained over longer-term follow-up is unknown. Furthermore, systematic long-term follow-up data on these metallic drug eluting stents with durable polymers are scarce.MethodsWe randomly assigned 1,800 patients undergoing PCI to EES or PES. The pre-specified composite primary endpoint was death, myocardial infarction (MI), or target vessel revascularization (TVR).ResultsFollow-up at 5 years was completed in 1,791 (99.5%) patients. Treatment with EES compared with PES led to a relative risk reduction of the primary endpoint by 27% (18.4% vs. 25.1%, p = 0.0005), driven by lower rates of MI (7.0% vs. 11.5%, p = 0.001) and TVR (7.4% vs. 11.4%, p = 0.003), but not with mortality (9.0% vs. 10.3%, relative risk 0.88, p = 0.36). Moreover, patients treated with EES compared with PES had lower rates of definite/probable stent thrombosis at 5 years (3.1% vs. 5.9%, p = 0.005). The hazard curves for TVR, MI, and stent thrombosis diverge over the first 3 years and, subsequently, progress in parallel.ConclusionsThe early- and medium-term superiority of EES over PES measured both by safety and efficacy endpoints is sustained at 5 years in this all-comer population. (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice [COMPARE]; NCT01016041)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号