首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
ObjectivesThe aim of the current study was to compare everolimus-eluting stents (EES) with sirolimus-eluting stents (SES) in patients undergoing primary angioplasty.BackgroundDrug-eluting stents may offer benefits in terms of repeat revascularization. However, as shown for first-generation drug-eluting stents, they may be counterbalanced by a potential higher risk of stent thrombosis, especially among patients with ST-segment elevation myocardial infarction (STEMI). No data have been reported so far on the long-term benefits and safety of the new generation of drug-eluting stents in STEMI.MethodsConsecutive STEMI patients admitted within 12 h of symptom onset and undergoing primary angioplasty and stent implantation at a tertiary center with 24-h primary percutaneous coronary intervention capability were randomly assigned to SES or EES. The primary endpoint was a major adverse cardiac event at 3-year follow-up. The secondary endpoints were death, reinfarction, definite or probable stent thrombosis, and target vessel revascularization at 3-year follow-up. No patient was lost to follow-up.ResultsFrom April 2007 to May 2009, 500 patients with STEMI were randomized to EES (n = 250) or SES (n = 250). No difference was observed in terms of baseline demographic and clinical characteristics between the groups. No difference was observed between the groups in terms of number of implanted stents per patient or total stent length. However, a larger reference diameter was observed with SES (3.35 ± 0.51 mm vs. 3.25 ± 0.51 mm, p = 0.001), whereas patients randomized to EES more often received glycoprotein IIb/IIIa inhibitors (54.4% vs. 42.4%, p = 0.006). Follow-up data were available in all patients (1,095 ± 159 days). No significant difference was observed between EES and SES in major adverse cardiac events (16% vs. 20.8%, adjusted hazard ratio [HR]: 0.75 [95% confidence interval (CI): 0.5 to 1.13], p = 0.17), cardiac death (4.4% vs. 5.6%, adjusted HR: 0.77 [95% CI: 0.35 to 1.71], p = 0.53), recurrent MI (6.4% vs. 10%, adjusted HR: 0.62 [95% CI: 0.33 to 1.16], p = 0.13), and target vessel revascularization (4.8% vs. 4.8%, adjusted HR: 1.00 [95% CI: 0.45 to 2.32], p = 0.99). However, EES was associated with a significant reduction in stent thrombosis (1.6% vs. 5.2%, adjusted HR: 0.3 [95% CI: 0.1 to 0.92], p = 0.035).ConclusionsThis study shows that among STEMI patients undergoing primary angioplasty, EES has similar efficacy as SES, but is associated with a significant reduction in stent thrombosis. (Randomized Comparison of Everolimus Eluting Stents and Sirolimus Eluting Stent in Patients With ST Elevation Myocardial Infarction [RACES-MI]; NCT01684982)  相似文献   

2.
ObjectivesThis study sought to evaluate the optimal percutaneous coronary intervention techniques using drug-eluting stents for bifurcation coronary lesions.BackgroundThe optimal bifurcation stenting technique needs to be evaluated.MethodsThe trial included 2 randomization studies separated by the presence of side branch (SB) stenosis for patients having non–left main bifurcation lesions. For 306 patients without SB stenosis, the routine final kissing balloon or leave-alone approaches were compared. Another randomization study compared the crush or single-stent approaches for 419 patients with SB stenosis.ResultsBetween the routine final kissing balloon and leave-alone groups for nondiseased SB lesions, angiographic restenosis occurred in 17.9% versus 9.3% (p = 0.064), comprising 15.1% versus 3.7% for the main branch (p = 0.004) and 2.8% versus 5.6% for the SB (p = 0.50) from 214 patients (69.9%) receiving 8-month angiographic follow-up. Incidence of major adverse cardiac events including death, myocardial infarction, or target vessel revascularization over 1 year was 14.0% versus 11.6% between the routine final kissing balloon and leave-alone groups (p = 0.57). In another randomization study for diseased SB lesions, 28.2% in the single-stent group received SB stents. From 300 patients (71.6%) receiving angiographic follow-up, between the crush and single-stent groups, angiographic restenosis rate was 8.4% versus 11.0% (p = 0.44), comprising 5.2% versus 4.8% for the main branch (p = 0.90) and 3.9% versus 8.3% for the SB (p = 0.12). One-year major adverse cardiac events rate between the crush and single-stent groups was 17.9% versus 18.5% (p = 0.84).ConclusionsAngiographic and clinical outcomes were excellent after percutaneous coronary intervention using drug-eluting stents with any stent technique for non–left main bifurcation lesions once the procedure was performed successfully.  相似文献   

3.
ObjectivesThe present study established criteria to differentiate simple from complex bifurcation lesions and compared 1-year outcomes stratified by lesion complexity after provisional stenting (PS) and 2-stent techniques using drug-eluting stents.BackgroundCurrently, no criterion can distinguish between simple and complex coronary bifurcation lesions. Comparisons of PS and 2-stent strategies stratified by lesion complexity have also not been reported previously.MethodsCriteria of bifurcation complexity in 1,500 patients were externally tested in another 3,660 true bifurcation lesions after placement of drug-eluting stents. The primary endpoint was the occurrence of a major adverse cardiac event (MACE) at 12 months. The secondary endpoint was the rate of stent thrombosis (ST).ResultsComplex (n = 1,108) bifurcation lesions were associated with a higher 1-year rate of MACE (16.8%) compared with simple (n = 2,552) bifurcation lesions (8.9%) (p < 0.001). The in-hospital ST and 1-year target lesion revascularization rates after 2-stent techniques in the simple group (1.0% and 5.6%, respectively) were significantly different from those after PS (0.2% [p = 0.007] and 3.2% [p = 0.009], respectively); however, 1-year MACE rates were not significantly different between the 2 groups. For complex bifurcation lesions, 2-stent techniques had lower rates of 1-year cardiac death (2.8%) and in-hospital MACE (5.0%) compared with PS (5.3%, p = 0.047; 8.4%, p = 0.031).ConclusionsComplex bifurcation lesions had higher rates of 1-year MACE and ST. The 2-stent and PS techniques were overall equivalent in 1-year MACE. However, 2-stent techniques for complex lesions elicited a lower rate of cardiac death and in-hospital MACE but higher rates of in-hospital ST and revascularization at 1 year for simple lesions.  相似文献   

4.
ObjectivesThis study sought to investigate the long-term comparative efficacy and safety of paclitaxel-eluting balloon (PEB), paclitaxel-eluting stent (PES), or balloon angioplasty (BA) for the treatment of drug-eluting stent restenosis.BackgroundThe optimal treatment of drug-eluting stent restenosis remains unknown. Although PEB has shown encouraging results, the long-term clinical efficacy and safety of PEB remains poorly defined.MethodsA total of 402 patients with clinically significant restenosis in limus-eluting stents were randomly assigned to receive PEB (n = 137), PES (n = 131), or BA (n = 134). For this analysis, PEB versus PES and PEB versus BA were compared. The primary efficacy and safety endpoints were target lesion revascularization and the composite of death or myocardial infarction.ResultsAt a median follow-up of 3 years, the risk of target lesion revascularization was comparable with PEB versus PES (hazard ratio [HR]: 1.46, 95% confidence interval [CI]: 0.91 to 2.33; p = 0.11) and lower with PEB versus BA (HR: 0.51, 95% CI: 0.34 to 0.74; p < 0.001). The risk of death/myocardial infarction tended to be lower with PEB versus PES (HR: 0.55, 95% CI: 0.28 to 1.07; p = 0.08), due to a lower risk of death (HR: 0.38, 95% CI: 0.17 to 0.87; p = 0.02). The risk of death/myocardial infarction was similar with PEB versus BA (HR: 0.96, 95% CI: 0.46 to 2.0; p = 0.91).ConclusionsAt 3 years, the use of PEB as compared with PES to treat patients with limus-eluting stent restenosis has similar efficacy and safety. PEB remains superior to BA. The sustained efficacy without trade-off in safety supports the role of PEB as treatment option for patients with drug-eluting stent restenosis. (Intracoronary Stenting and Angiographic Results: Drug Eluting Stent In-Stent Restenosis: 3 Treatment Approaches [ISAR-DESIRE 3]; NCT00987324)  相似文献   

5.
ObjectivesThis study sought to evaluate the self-expandable ACURATE TA device (Symetis SA, Ecublens, Switzerland) in a cohort of patients with pure aortic regurgitation (AR).BackgroundTranscatheter aortic valve replacement (TAVR) has been initially considered as an alternative for high-risk patients with aortic stenosis. Although the current experience is limited, TAVR might be also an alternative to treat patients with pure, severe AR.MethodsBetween April 2012 and December 2013, a total of 8 high-risk patients with pure, severe AR were enrolled (grade III+). Clinical and hemodynamic data as well as data on device and procedure parameters and outcomes were collected.ResultsPatient mean was 72.5 ± 8.4 years, and 37.5% of patients were female. Logistic EuroSCORE was 34.0 ± 7.9% and the Society of Thoracic Surgeons score was 7.3 ± 3.3% on average. Two patients had undergone emergency aortic operation before due to acute type A aortic dissection, and both were treated by replacement of the ascending aorta (including root reconstruction) and the aortic arch combined with or without E-vita Open stent graft (Jotec GmbH, Hechingen, Germany) (January 2011 and March 2012), whereas the other patients experienced primary AR. All patients underwent successful transapical TAVR with the transapical ACURATE TA device (size small, n = 1, size medium, n = 3, size large, n = 4) without any intraprocedural complications according to the Valve Academic Research Consortium 2 criteria. Post-procedure AR grade I+ or lower, as revealed by transoesophageal echocardiography and angiography, was present in all 8 patients. At 30 days, the stroke incidence and all-cause mortality rate were 0%.ConclusionsThis small single-center series demonstrates the feasibility of transapical TAVR with the self-expandable ACURATE TA device in high-risk patients with severe AR.  相似文献   

6.
ObjectivesThis study sought to compare rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE) (composite of death, myocardial infarction, or stroke) after coronary stenting with drug-eluting stents (DES) versus bare-metal stents (BMS) in patients who participated in the DAPT (Dual Antiplatelet Therapy) study, an international multicenter randomized trial comparing 30 versus 12 months of dual antiplatelet therapy in subjects undergoing coronary stenting with either DES or BMS.BackgroundDespite antirestenotic efficacy of coronary DES compared with BMS, the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Many clinicians perceive BMS to be associated with fewer adverse ischemic events and to require shorter-duration dual antiplatelet therapy than DES.MethodsProspective propensity-matched analysis of subjects enrolled into a randomized trial of dual antiplatelet therapy duration was performed. DES- and BMS-treated subjects were propensity-score matched in a many-to-one fashion. The study design was observational for all subjects 0 to 12 months following stenting. A subset of eligible subjects without major ischemic or bleeding events were randomized at 12 months to continued thienopyridine versus placebo; all subjects were followed through 33 months.ResultsAmong 10,026 propensity-matched subjects, DES-treated subjects (n = 8,308) had a lower rate of stent thrombosis through 33 months compared with BMS-treated subjects (n = 1,718, 1.7% vs. 2.6%; weighted risk difference −1.1%, p = 0.01) and a noninferior rate of MACCE (11.4% vs. 13.2%, respectively, weighted risk difference −1.8%, p = 0.053, noninferiority p < 0.001).ConclusionsDES-treated subjects have long-term rates of stent thrombosis that are lower than BMS-treated subjects. (The Dual Antiplatelet Therapy Study [DAPT study]; NCT00977938)  相似文献   

7.
ObjectivesThis study sought to review the outcomes for the Sapien and Sapien XT valves (Edwards Lifesciences, Irvine, California) for percutaneous pulmonary valve implantation (PPVI).BackgroundPPVI has emerged as a viable alternative to surgery in patients with right ventricular (RV) outflow tract dysfunction. Limited data are available for the Sapien and Sapien XT valves in this setting.MethodsRetrospective analysis was performed for all patients to have undergone PPVI using the Edwards Sapien system at a large quaternary center.ResultsTwenty-five patients (70% male, mean age 34 ± 8.9 years) were identified. Primary underlying diagnosis was tetralogy of Fallot (n = 15), Ross procedure (n = 5), and other (n = 5). RV outflow tract characteristics included: biological valve (n = 16) and homograft (n = 9). Technical success was 96%. One patient required elective surgical pulmonary valve replacement for a high residual gradient. Pre-stenting was performed in all cases (52% covered stents). Valve sizes were 23 mm (n = 8), 26 mm (n = 15), and 29 mm (n = 2). Procedural hemodynamics revealed a decrease in the mean RV-to-systemic pressure ratio from 0.64 to 0.36 (p < 0.001) and RV-to-pulmonary artery (PA) gradient from 39 to 9 mm Hg (p < 0.001). No patient had clinically significant pulmonary regurgitation (PR). At a mean follow-up of 3.5 ± 2.1 years (range 0.3 to 7.2 years), there were no deaths. One patient required reintervention (no PR evident immediately post-procedure but severe valvular PR at 1 year requiring a valve-in-valve procedure). There were no episodes of endocarditis and no stent fractures. There was preserved valve function during follow-up with no change in RV-to-PA gradient nor PR severity.ConclusionsThe Edwards Sapien system is a viable and durable option for PPVI in this single-center study.  相似文献   

8.
ObjectivesThis study sought to report the results of a prospective randomized controlled trial comparing paclitaxel-coated balloons (PCB) versus drug-eluting stents (DES) in long infrapopliteal lesions.BackgroundDES have an established role in the treatment of short infrapopliteal lesions, whereas there is increasing evidence for the use of PCB in longer below-the-knee lesions.MethodsInclusion criteria were patients with Rutherford classes 3 to 6 and angiographically documented infrapopliteal disease with a minimum lesion length of 70 mm. The primary endpoint was target lesion restenosis >50% assessed by digital angiography at 6 months. Secondary endpoints included immediate post-procedure stenosis and target lesion revascularization.ResultsFifty patients were randomized to undergo infrapopliteal PCB angioplasty (25 arteries in 25 limbs; PCB group) or primary DES placement (30 arteries in 27 limbs; DES group). Immediate residual post-procedure stenosis was significantly lower in DES (9.6 ± 2.2% vs. 24.8 ± 3.5% in PCB; p < 0.0001). At 6 months, 5 patients died (2 in PCB vs. 3 in DES; p = 1.00) and 3 suffered a major amputation (1 in PCB vs. 2 in DES; p = 1.00). In total, 44 angiograms were evaluable with quantitative vessel analysis. Binary (>50%) angiographic restenosis rate was significantly lower in DES (7 of 25 [28%] vs. 11 of 19 [57.9%] in PCB; p = 0.0457). There were no significant differences with regard to target lesion revascularization (2 of 26 [7.7%] in DES vs. 3 of 22 [13.6%] in PCB; p = 0.65). Positive vessel wall remodeling was observed in 3 cases in the PCB arm (3 of 19 [(15.8%)] vs. 0 of 19 [0%] in DES; p = 0.07).ConclusionsCompared with PCB in long infrapopliteal lesions, DES are related with significantly lower residual immediate post-procedure stenosis and have shown significantly reduced vessel restenosis at 6 months. PCB may produce positive vessel remodeling. (Infrapopliteal Drug-Eluting Angioplasty Versus Stenting [IDEAS-I]; NCT01517997)  相似文献   

9.
ObjectivesThis study sought to assess the rate and predictors of 1-year restenosis after drug-eluting stent implantation for femoropopliteal (FP) lesions in patients with peripheral arterial disease.BackgroundZilver PTX, a paclitaxel-eluting stent for FP lesions, provides superior outcomes to angioplasty and bare-metal stents in clinical trials. However, its real-world outcomes and the associated features remain unclear.MethodsThis was a prospective multicenter study enrolling 831 FP lesions (797 limbs, 690 patients) treated by Zilver PTX implantation. The primary endpoint was 1-year restenosis. Secondary endpoints included major adverse limb event and stent thrombosis.ResultsMean lesion length was 17 ± 10 cm. One-year restenosis, major adverse limb event, and stent thrombosis rates were 37%, 22%, and 2%, respectively. The generalized linear mixed model showed that lesion length ≥16 cm assessed by angiography and distal external elastic membrane area ≤27 mm2 and minimum stent area ≤12 mm2 assessed by intravascular ultrasound were independent risk factors for restenosis. One-year restenosis rates were 15% in cases with none of these risk factors and 50% in those with ≥2 risk factors.ConclusionsThe current study demonstrated 1-year real-world outcomes after drug-eluting stent treatment for FP lesions, including challenging ones in clinical practice. Lesion length, external elastic membrane area, and minimum stent area were independent predictors for restenosis. (Zilver PTX for the Femoral Artery and Proximal Popliteal Artery—Prospective Multicenter Registry [ZEPHYR]; UMIN000008433)  相似文献   

10.
ObjectivesThe aim of this study was to investigate the correlation between in-stent neointimal tissue without features of neoatherosclerosis and long-term clinical outcomes.BackgroundRecent studies have reported differential morphological characteristics of in-stent neointimal tissue assessed by optical coherence tomography (OCT).MethodsThe study population consisted of 336 patients with 368 drug-eluting stent-treated lesions. Patients received a follow-up OCT examination without any intervention. OCT-based neointima was categorized as homogeneous (n = 227 lesions in 208 patients), heterogeneous (n = 79 lesions in 73 patients), or layered (n = 62 lesions in 55 patients). Major adverse cardiac events (MACE) (a composite of cardiac death, nonfatal myocardial infarction, or target lesion revascularization) were assessed according to neointimal patterns during long-term clinical follow-up after OCT examination.ResultsThe time interval between stent implantation and OCT examination was similar among the 3 groups (p = 0.64). On multivariate logistic regression analysis, the significant determinant for the heterogeneous neointima was age (odds ratio [OR]: 1.037, 95% confidence interval [CI]: 1.007 to 1.068, p = 0.015) and an initial clinical presentation of acute coronary syndrome (OR: 1.967, 95% CI: 1.159 to 3.339, p = 0.012). The overall median follow-up duration for all patients after follow-up OCT examination was 31.0 months, and this was statistically different among the heterogeneous group (22.0 months), the homogeneous group (34.0 months), and the layered group (28.0 months, overall p = 0.002). MACE occurred more frequently in patients with heterogeneous neointima over a median 31-month follow-up period after OCT examination (13.7% vs. 2.9% in homogeneous vs. 7.3% in layered, p = 0.001). A propensity score–adjusted Cox regression analysis showed that independent risk factors for MACE were inclusion in the heterogeneous neointima (hazard ratio: 3.925, 95% CI: 1.445 to 10.662, p = 0.007) and minimal lumen cross-sectional area (hazard ratio: 0.368, 95% CI: 0.242 to 0.560, p < 0.001).ConclusionsDetermination of neointimal characteristics is helpful in predicting long-term clinical outcomes. Our data suggest that heterogeneous lesions are linked to poor long-term clinical prognoses.  相似文献   

11.
AimsEvaluation of safety and efficacy of ProNOVA XR, a new generation of polymer-free sirolimus eluting stents (SES), utilizing a pharmaceutical excipient for timed release of sirolimus from the XR platform.Methods and resultsSafety and efficacy of ProNOVA XR coronary stent system was examined in EURONOVA prospective, single arm, multi-center registry of 50 patients with de novo native coronary lesions up to 28 mm in length in arteries between 2.25 and 4 mm.At 6-month, in-stent late lumen loss by QCA was 0.45 ± 0.41 mm and in-stent neointimal volume obstruction in the IVUS sub-study was 14 ± 11%. One-year clinical follow-up revealed a favorable safety profile, with 2% of in-hospital MACE and 6.4% of MACE from hospital discharge up to 12 months (including 1 cardiac death >30 days after stent implantation and 2 TLRs). According to the ARC definition, there was no definite or probable stent thrombosis and 1 possible stent thrombosis (2%) up to 12 months of clinical follow-up.ConclusionsIn this preliminary evaluation, ProNOVA XR polymer-free sirolimus eluting stent system appeared safe with an early promise of adequate effectiveness in the treatment of de novo coronary lesions in up to 12 months of clinical, angiographic and IVUS follow-up.  相似文献   

12.
ObjectivesThe aim of BIOLUX P-II (BIOTRONIK'S–First in Man study of the Passeo-18 LUX drug releasing PTA Balloon Catheter vs. the uncoated Passeo-18 PTA balloon catheter in subjects requiring revascularization of infrapopliteal arteries) trial was to compare the safety and efficacy of a novel paclitaxel-coated drug-eluting balloon (DEB) versus an uncoated balloon (percutaneous transluminal angioplasty [PTA]) in de novo or native restenotic lesions of the infrapopliteal arteries in patients with claudication and critical limb ischemia.BackgroundDEB have shown promising results in femoropopliteal lesions, but data for infrapopliteal lesions are scarce.MethodsIn this prospective, multicenter, randomized first-in-man study, 72 patients were randomized 1:1 to either a Passeo-18 Lux DEB (Biotronik AG, Buelach, Switzerland) (n = 36) or Passeo-18 PTA (n = 36). Follow-up assessments were scheduled at 1, 6, and 12 months, with angiographic assessment at 6 months. Adverse events were adjudicated by an independent clinical events committee, and angiographic parameters were assessed by an independent core laboratory.ResultsThe primary safety endpoint (a composite of all-cause mortality, target extremity major amputation, target lesion thrombosis, and target vessel revascularization at 30 days) was 0% in the DEB group versus 8.3% in the PTA group (p = 0.239). The primary performance endpoint (patency loss at 6 months) was 17.1% in the DEB group versus 26.1% in the PTA group (p = 0.298), and major amputations of the target extremity occurred in 3.3% versus 5.6% of the patients at 12 months, respectively.ConclusionsThe Passeo-18 Lux DEB has been proven to be safe and effective in infrapopliteal lesions with comparable outcomes to PTA.  相似文献   

13.
ObjectivesThis study sought to compare the outcomes of fractional flow reserve (FFR)–guided and angiography (Angio)–guided provisional side-branch (SB) stenting for true coronary bifurcation lesions.BackgroundAngio-guided provisional SB stenting after stenting of the main vessel provides favorable outcomes for the majority of coronary bifurcation lesions. Whether an FFR-guided provisional stenting approach is superior has not been studied.MethodsA total of 320 patients with single Medina 1,1,1 and 0,1,1 coronary bifurcation lesions undergoing stenting with a provisional SB approach were randomly assigned 1:1 to Angio-guided and FFR-guided groups. SB stenting was performed for Thrombolysis In Myocardial Infarction flow grade <3, ostial SB stenosis >70%, or greater than type A dissection after main vessel stenting in the Angio-guided group and for SB-FFR <0.80 in the FFR-guided group. The primary endpoint was the 1-year composite rate of major adverse cardiac events (cardiac death, myocardial infarction, and clinically driven target vessel revascularization).ResultsComparing the Angio-guided and FFR-guided groups, treatment of the SB (balloon or stenting) was performed in 63.1% and 56.3% of lesions respectively (p = 0.07); stenting of the SB was attempted in 38.1% and 25.9%, respectively (p = 0.01); and, when attempted, stenting was successful in 83.6% and 73.3% of SBs, respectively (p = 0.01). The 1-year composite major adverse cardiac event rate was 18.1% in both groups (hazard ratio: 0.91, 95% confidence interval: 0.48 to 1.88; p = 1.00). The 1-year target vessel revascularization and stent thrombosis rates were 6.9% and 5.6% (p = 0.82) and 1.3% and 0.6% (p = 0.56) in the Angio-guided and FFR-guided groups, respectively.ConclusionsIn this multicenter, randomized trial, angiographic and FFR guidance of provisional SB stenting of true coronary bifurcation lesions provided similar 1-year clinical outcomes. (Randomized Study on DK Crush Technique Versus Provisional Stenting Technique for Coronary Artery Bifurcation Lesions; ChiCTR-TRC-07000015)  相似文献   

14.
ObjectivesThis study sought to evaluate whether the permanent fluoropolymer-coated Xience Xpedition everolimus-eluting stent (Xience-EES) exhibits lower acute thrombogenicity compared with contemporary drug-eluting stents (DES) with biodegradable polymer coatings in an acute swine shunt model.BackgroundPrevious pre-clinical and clinical experience suggests that several factors may influence the predisposition for acute thrombus formation of polymer-coated DES, including stent design and the polymer coating technology. It remains unclear whether relevant differences exist with respect to acute thrombogenicity, particularly between current commercial stent designs using permanent polymers and those using biodegradable polymers.MethodsAn ex vivo carotid to jugular arteriovenous porcine shunt model involving a test circuit of 3 in-line stents, was used to test acute thrombogenicity, where Xience-EES (n = 24) was compared with 4 CE-marked DES with biodegradable polymer coatings (BioMatrix Flex, Synergy, Nobori, and Orsiro [n = 6 each]). After 1 h of circulation, platelet aggregation in whole mount stents was evaluated by confocal microscopy with immunofluorescent staining against dual platelet markers (CD61/CD42b) along with scanning electron microscopy.ResultsXience-EES showed the least percentage of thrombus-occupied area as compared with the biodegradable polymer-coated DES, with a significant difference compared with BioMatrix Flex and Synergy (mean differences: [BioMatrix Flex: 15.54, 95% confidence interval [CI]: 11.34 to 19.75, p < 0.001; Synergy: 8.64, 95% CI: 4.43 to 12.84, p < 0.001; Nobori: 4.22, 95% CI: -0.06 to 8.49, p = 0.055; Orsiro: 2.95, 95% CI: -1.26 to 7.15, p = 0.286). The number of cell nuclei on strut surfaces was also the least in Xience-EES, with a significant difference relative to BioMatrix Flex, Nobori, and Orsiro (mean ratios: BioMatrix Flex: 4.73, 95% CI: 2.46 to 9.08, p < 0.001; Synergy: 1.44, 95% CI: 0.75 to 2.76, p = 0.51; Nobori: 5.97, 95% CI: 3.11 to 11.44, p < 0.001; Orsiro: 5.16, 95% CI: 2.69 to 9.91, p < 0.001).ConclusionsXience-EES’s overall design confers acute thromboresistance relative to contemporary DES with biodegradable coatings, with less platelet aggregation versus BioMatrix Flex and Synergy, and less inflammatory cell attachment versus BioMatrix Flex, Nobori, and Orsiro, in an ex vivo swine shunt model, which lends support to reported clinical findings of lower early stent thrombosis.  相似文献   

15.
ObjectivesThis study sought to compare the outcomes of spot stenting versus long stenting after intentional subintimal approach for long femoropopliteal chronic total occlusions (CTO).BackgroundThe optimal stenting strategy following the subintimal recanalization of long femoropopliteal chronic total occlusions has not been investigated.MethodsA total of 196 limbs in 163 patients, implanted with bare nitinol stents after subintimal approach in long femoropopliteal occlusions (lesion length 25 ± 8 cm), were retrospectively analyzed. The primary patency was compared between spot stenting (n = 129) and long stenting (n = 67).ResultsBaseline characteristics and immediate procedural results were similar between groups. Adjusted-primary patency (47% vs. 77%, p < 0.001) and adjusted-freedom from target lesion revascularization (52% vs. 84%, p < 0.001) at 2 years were significantly lower in the long stenting group than in the spot stenting group. The incidence of stent fracture, fracture type, and restenosis pattern did not differ between groups. Long stenting was an independent predictor of restenosis (hazard ratio [HR]: 2.0) along with other risk factors such as nonuse of clopidogrel (HR: 3.3) or cilostazol (HR: 2.2), small stent diameter (HR: 0.6), poor run-off (HR: 1.9), and post-procedural ankle-brachial index (HR: 0.1). Compared with spot stenting after adjustment using inverse probability of treatment weighting, long stenting, especially involving the P2 or P3 segment of the popliteal artery, was independently associated with 7.5-fold increases in restenosis risk (p < 0.001).ConclusionsThe primary patency was significantly higher with spot stenting than with long stenting following subintimal approach for long femoropopliteal chronic total occlusions. The risk of restenosis was especially higher when long stenting was extended to the distal popliteal artery.  相似文献   

16.
ObjectivesThis study sought to assess the safety and the efficacy of bivalirudin compared with unfractionated heparin (UFH) alone in the subset of patients at increased risk of bleeding undergoing transfemoral elective percutaneous coronary intervention (PCI).BackgroundBivalirudin, a synthetic direct thrombin inhibitor, determines a significant decrease of in-hospital bleeding following PCI.MethodsThis is a single-center, investigator-initiated, randomized, double-blind, controlled trial. Consecutive biomarker-negative patients at increased bleeding risk undergoing PCI through the femoral approach were randomized to UFH (UFH group; n = 419) or bivalirudin (bivalirudin group; n = 418). The primary endpoint was the rate of in-hospital major bleeding.ResultsThe primary endpoint occurred in 11 patients (2.6%) in the UFH group versus 14 patients (3.3%) in the bivalirudin group (odds ratio: 0.78; 95% confidence interval: 0.35 to 1.72; p = 0.54). Distribution of access-site and non–access-site bleeding was 18% and 82% in the UFH group versus 50% and 50% in the bivalirudin group (p = 0.10).ConclusionsThe results of this randomized study, carried out at a single institution, suggest that there is no difference in major bleeding rate between bivalirudin and UFH in increased-risk patients undergoing transfemoral PCI. (Novel Approaches in Preventing and Limiting Events III Trial: Bivalirudin in High-Risk Bleeding Patients [NAPLES III]; NCT01465503)  相似文献   

17.
ObjectivesThis study investigated the feasibility of visual and quantitative assessment of coronary vessel wall contrast enhancement (CE) for detection of symptomatic atherosclerotic coronary artery disease (CAD) and subclinical coronary vasculitis in autoimmune inflammatory disease (systemic lupus erythematosus [SLE]), as well as the association with aortic stiffness, an established marker of risk.BackgroundCoronary CE by cardiac magnetic resonance (CMR) is a novel noninvasive approach to visualize gadolinium contrast uptake within the coronary artery vessel wall.MethodsA total of 75 subjects (CAD: n = 25; SLE: n = 27; control: n = 23) underwent CMR imaging using a 3-T clinical scanner. Coronary arteries were visualized by a T2-prepared steady state free precession technique. Coronary wall CE was visualized using inversion-recovery T1 weighted gradient echo sequence 40 min after administration of 0.2 mmol/kg gadobutrol. Proximal coronary segments were visually examined for distribution of CE and quantified for contrast-to-noise ratio (CNR) and total CE area.ResultsCoronary CE was prevalent in patients (93%, n = 42) with a diffuse pattern for SLE and a patchy/regional distribution in CAD patients. Compared with control subjects, CNR values and total CE area in patients with CAD and SLE were significantly higher (mean CNR: 3.9 ± 2.5 vs. 6.9 ± 2.5 vs. 6.8 ± 2.0, respectively; p < 0.001; total CE area: median 0.8 [interquartile range (IQR): 0.6 to 1.2] vs. 3.2 [IQR: 2.6 to 4.0] vs. 3.3 [IQR: 1.9 to 4.5], respectively; p < 0.001). Both measures were positively associated with aortic stiffness (CNR: r = 0.61, p < 0.01; total CE area: 0.36, p = 0.03), hypercholesterolemia (r = 0.68, p < 0.001; r = 0.61, p < 0.001) and hypertension (r = 0.40, p < 0.01; r = 0.32, p < 0.05).ConclusionsWe demonstrate that quantification of coronary CE by CNR and total CE area is feasible for detection of subclinical and clinical uptake of gadolinium within the coronary vessel wall. Coronary vessel wall CE may become an instrumental novel direct marker of vessel wall injury and remodeling in subpopulations at risk.  相似文献   

18.
IntroductionCentral (aortic or carotid) pulse pressure (PP) is more strongly associated with local organ damage and possibly mortality than brachial PP.AimTo investigate for the first time the association of femoral (f) PP with all-cause mortality, and incident cardiovascular disease (CVD), coronary heart disease (CHD) and cerebrovascular disease (CerVD) events, as well as with markers of renal function (estimated glomerular filtration rate, eGFR, and microalbuminuria).MethodsWe used data from a population-based study, by design including 50% type 2 diabetes and impaired glucose metabolism (IGM). The baseline examination included non-invasive PP assessment at the brachial, aorta (Sphygmocor device), carotid and femoral (ultrasound distention waves calibrated by brachial mean and diastolic pressure) arteries.ResultsAfter 7.8 years of follow-up (n = 449, age: 68.9 ± 6.0 males: 52%), 66 participants had died, 102 had a CVD event, 45 a CHD event, and 31 a CerVD event. PP at all sites was associated with incident all-cause mortality and CVD events. Only fPP was, however, associated with incident CHD events, even after adjustment for CVD risk factors (HRs 1.31 [1.07–1.61 95% CIs]). No association between PP and incident CerVD events was found – possibly due to the small number of events. fPP was associated with renal function but this was similar to other PP indices. No interaction between each any local PP index and glucose metabolism status or renal function was present.ConclusionBeyond anatomical topography, local fPP provide important information related to CVD events. This possibility and the underlying mechanisms should be further investigated.  相似文献   

19.
ObjectivesThis study aimed to assess 6-month outcomes in patients with implantable cardioverter-defibrillators (ICDs) undergoing renal sympathetic denervation (RSD) for refractory ventricular arrhythmias (VAs).BackgroundICDs are generally indicated for patients at high risk of malignant VAs. Sympathetic hyperactivity plays a critical role in the development, maintenance, and aggravation of VAs.MethodsA total of 10 patients with refractory VA underwent RSD. Underlying conditions were Chagas disease (n = 6), nonischemic dilated cardiomyopathy (n = 2), and ischemic cardiomyopathy (n = 2). Information on the number of ventricular tachycardia (VT)/ventricular fibrillation (VF) episodes and device therapies (antitachycardia pacing/shocks) in the previous 6 months as well as 1 and 6 months post-treatment was obtained from ICD interrogation.ResultsThe median number of VT/VF episodes/antitachycardia pacing/shocks 6 months before RSD was 28.5 (range 1 to 106)/20.5 (range 0 to 52)/8 (range 0 to 88), respectively, and was reduced to 1 (range 0 to 17)/0 (range 0 to 7)/0 (range 0 to 3) at 1 month and 0 (range 0 to 9)/0 (range 0 to 7)/0 (range 0 to 3) at 6 months afterward, respectively. There were no major procedure-related complications. Two patients experienced sustained VT within the first week; in both cases, no further episodes occurred during follow-up. Two patients were nonresponders: 1 with persistent idioventricular rhythm and 1 with multiple renal arteries and incomplete ablation. Three patients died during follow-up. None of the deaths was attributed to VA.ConclusionsIn patients with ICDs and refractory VAs, RSD was associated with reduced arrhythmic burden with no procedure-related complications. Randomized controlled trials investigating RSD for treatment of refractory VAs in patients with increased sympathetic activity are needed.  相似文献   

20.
Introduction and objectivesWe sought to compare the long-term clinical outcome of patients with ST-segment elevation myocardial infarction treated with paclitaxel-eluting stents or everolimus-eluting stents and the influence of thrombectomy on outcomes.MethodsThe ESTROFA-IM is a multicenter retrospective registry collecting consecutive patients with infarction treated with these stents in 16 centers. Propensity-score matching was performed to select comparable stent groups and comparable groups with and without thrombectomy.ResultsAfter matching patients, 350 treated with everolimus-eluting stents and 350 with paclitaxel-eluting stents were included in the analysis. The clinical and angiographic characteristics were comparable in both groups. The 2-year incidence of death, infarction, and target lesion revascularization was 14.9% for paclitaxel-eluting stents and 11.5% for everolimus-eluting stents (P = .04) and the incidence of definite/probable thrombosis 4.3% and 1.4%, respectively (P = .01). The use of paclitaxel-eluting stents was an independent predictor for events (hazard ratio = 2.44, 95% confidence interval, 1.28-4.65; P = .006). The benefit of everolimus-eluting stents over paclitaxel-eluting stents regarding stent thrombosis was more evident in the nonthrombectomy subgroup (5.4% vs 1.4%; P = .01). A significant interaction was found in the subgroups with and without thombectomy in the comparison between paclitaxel-eluting stents and everolimus-eluting stents for the end-point of stent thrombosis (P = .039).ConclusionsThe results of this multicenter registry suggest better clinical outcomes with the everolimus-eluting stents in ST-segment elevation myocardial infarction. The lower risk of thrombosis with these stents could be more relevant in the absence of thrombectomy.Full English text available from: www.revespcardiol.org/en  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏