首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ObjectivesThis study sought to report the results of a prospective randomized controlled trial comparing paclitaxel-coated balloons (PCB) versus drug-eluting stents (DES) in long infrapopliteal lesions.BackgroundDES have an established role in the treatment of short infrapopliteal lesions, whereas there is increasing evidence for the use of PCB in longer below-the-knee lesions.MethodsInclusion criteria were patients with Rutherford classes 3 to 6 and angiographically documented infrapopliteal disease with a minimum lesion length of 70 mm. The primary endpoint was target lesion restenosis >50% assessed by digital angiography at 6 months. Secondary endpoints included immediate post-procedure stenosis and target lesion revascularization.ResultsFifty patients were randomized to undergo infrapopliteal PCB angioplasty (25 arteries in 25 limbs; PCB group) or primary DES placement (30 arteries in 27 limbs; DES group). Immediate residual post-procedure stenosis was significantly lower in DES (9.6 ± 2.2% vs. 24.8 ± 3.5% in PCB; p < 0.0001). At 6 months, 5 patients died (2 in PCB vs. 3 in DES; p = 1.00) and 3 suffered a major amputation (1 in PCB vs. 2 in DES; p = 1.00). In total, 44 angiograms were evaluable with quantitative vessel analysis. Binary (>50%) angiographic restenosis rate was significantly lower in DES (7 of 25 [28%] vs. 11 of 19 [57.9%] in PCB; p = 0.0457). There were no significant differences with regard to target lesion revascularization (2 of 26 [7.7%] in DES vs. 3 of 22 [13.6%] in PCB; p = 0.65). Positive vessel wall remodeling was observed in 3 cases in the PCB arm (3 of 19 [(15.8%)] vs. 0 of 19 [0%] in DES; p = 0.07).ConclusionsCompared with PCB in long infrapopliteal lesions, DES are related with significantly lower residual immediate post-procedure stenosis and have shown significantly reduced vessel restenosis at 6 months. PCB may produce positive vessel remodeling. (Infrapopliteal Drug-Eluting Angioplasty Versus Stenting [IDEAS-I]; NCT01517997)  相似文献   

2.
ObjectivesThis study sought to evaluate the optimal percutaneous coronary intervention techniques using drug-eluting stents for bifurcation coronary lesions.BackgroundThe optimal bifurcation stenting technique needs to be evaluated.MethodsThe trial included 2 randomization studies separated by the presence of side branch (SB) stenosis for patients having non–left main bifurcation lesions. For 306 patients without SB stenosis, the routine final kissing balloon or leave-alone approaches were compared. Another randomization study compared the crush or single-stent approaches for 419 patients with SB stenosis.ResultsBetween the routine final kissing balloon and leave-alone groups for nondiseased SB lesions, angiographic restenosis occurred in 17.9% versus 9.3% (p = 0.064), comprising 15.1% versus 3.7% for the main branch (p = 0.004) and 2.8% versus 5.6% for the SB (p = 0.50) from 214 patients (69.9%) receiving 8-month angiographic follow-up. Incidence of major adverse cardiac events including death, myocardial infarction, or target vessel revascularization over 1 year was 14.0% versus 11.6% between the routine final kissing balloon and leave-alone groups (p = 0.57). In another randomization study for diseased SB lesions, 28.2% in the single-stent group received SB stents. From 300 patients (71.6%) receiving angiographic follow-up, between the crush and single-stent groups, angiographic restenosis rate was 8.4% versus 11.0% (p = 0.44), comprising 5.2% versus 4.8% for the main branch (p = 0.90) and 3.9% versus 8.3% for the SB (p = 0.12). One-year major adverse cardiac events rate between the crush and single-stent groups was 17.9% versus 18.5% (p = 0.84).ConclusionsAngiographic and clinical outcomes were excellent after percutaneous coronary intervention using drug-eluting stents with any stent technique for non–left main bifurcation lesions once the procedure was performed successfully.  相似文献   

3.
ObjectivesThis study sought to investigate the long-term comparative efficacy and safety of paclitaxel-eluting balloon (PEB), paclitaxel-eluting stent (PES), or balloon angioplasty (BA) for the treatment of drug-eluting stent restenosis.BackgroundThe optimal treatment of drug-eluting stent restenosis remains unknown. Although PEB has shown encouraging results, the long-term clinical efficacy and safety of PEB remains poorly defined.MethodsA total of 402 patients with clinically significant restenosis in limus-eluting stents were randomly assigned to receive PEB (n = 137), PES (n = 131), or BA (n = 134). For this analysis, PEB versus PES and PEB versus BA were compared. The primary efficacy and safety endpoints were target lesion revascularization and the composite of death or myocardial infarction.ResultsAt a median follow-up of 3 years, the risk of target lesion revascularization was comparable with PEB versus PES (hazard ratio [HR]: 1.46, 95% confidence interval [CI]: 0.91 to 2.33; p = 0.11) and lower with PEB versus BA (HR: 0.51, 95% CI: 0.34 to 0.74; p < 0.001). The risk of death/myocardial infarction tended to be lower with PEB versus PES (HR: 0.55, 95% CI: 0.28 to 1.07; p = 0.08), due to a lower risk of death (HR: 0.38, 95% CI: 0.17 to 0.87; p = 0.02). The risk of death/myocardial infarction was similar with PEB versus BA (HR: 0.96, 95% CI: 0.46 to 2.0; p = 0.91).ConclusionsAt 3 years, the use of PEB as compared with PES to treat patients with limus-eluting stent restenosis has similar efficacy and safety. PEB remains superior to BA. The sustained efficacy without trade-off in safety supports the role of PEB as treatment option for patients with drug-eluting stent restenosis. (Intracoronary Stenting and Angiographic Results: Drug Eluting Stent In-Stent Restenosis: 3 Treatment Approaches [ISAR-DESIRE 3]; NCT00987324)  相似文献   

4.
ObjectivesA Bayesian network meta-analysis was performed comparing the efficacy and safety of drug-eluting balloons (DEB), drug-eluting stents (DES), or plain old balloon angioplasty (POBA) for treatment of in-stent restenosis (ISR).BackgroundOptimal treatment options for ISR have not been well established.MethodsRandomized, controlled trials comparing DEB, DES, and POBA for the treatment of ISR after percutaneous coronary intervention with bare metal stent or DES were included. The primary outcome was target lesion revascularization (TLR). The pairwise posterior median odds ratio (OR) with 95% credible interval (CrI) was the effect measure.ResultsThis analysis included 2,059 patients from 11 RCTs. The risk of TLR was markedly lower in patients treated with DEB (OR: 0.22, 95% CrI: 0.10 to 0.42) or DES (OR: 0.24, 95% CrI: 0.11 to 0.47) than in those treated with POBA in a random-effects model. In a comparison of DEB and DES, the risk of TLR (OR: 0.92, 95% CrI: 0.43 to 1.90) was similar. The risk of MI or all-cause mortality was lowest in the DEB group compared with the DES and POBA groups, which did not meet statistical significance. The risk of major adverse cardiac events, which was mainly driven by TLR, was also significantly lower in the DEB or and DES group (OR: 0.28, 95% CrI: 0.14 to 0.53) than in the POBA group, but it was similar between the DEB and DES groups (OR: 0.84, 95% CrI: 0.45 to 1.50). The probability of being ranked as the best treatment was 59.9% (DEB), 40.1% (DES), and 0.1% (POBA) in terms of TLR, whereas it was 63.0% (DEB), 35.3% (POBA), and 1.7% (DES) in terms of MI.ConclusionsLocal drug delivery by DEB or DES for ISR lesions was markedly better than POBA in preventing TLR, but not for MI or mortality. Among the 2 different strategies of drug delivery for ISR lesions, treatment with DEB showed a trend of less development of MI than did treatment with DES.  相似文献   

5.
ObjectivesThe intention this PEPCAD-DES (Treatment of Drug-eluting Stent [DES] In-Stent Restenosis With SeQuent Please Paclitaxel Eluting Percutaneous Transluminal Coronary Angioplasty [PTCA] Catheter) study update was to demonstrate the safety and efficacy of paclitaxel-coated balloon (PCB) angioplasty in patients with DES-ISR at 3 years.BackgroundIn the PEPCAD-DES trial late lumen loss and the need for repeat target lesion revascularization (TLR) was significantly reduced with PCB angioplasty compared with plain old balloon angioplasty (POBA) in patients with drug-eluting stent in-stent restenosis (DES-ISR) at 6 months. We evaluated whether the clinical benefit of reduced TLR and major adverse cardiac events (MACE) was maintained up to 3 years.MethodsA total of 110 patients with DES-ISR in native coronary arteries with reference diameters ranging from 2.5 mm to 3.5 mm and lesion lengths ≤22 mm were randomized to treatment with either PCB or POBA in a multicenter, randomized, single-blind clinical study. With a 2:1 randomization, 72 patients were randomized to the PCB group and 38 patients to the POBA group. At baseline, there were lesions with at least 2 stent layers in PCB (52.8%, 38 of 72) and POBA (55.3%, 21 of 38) patients.ResultsAt 36 months, the TLR rates were significantly lower in the PCB group compared with the POBA control group (19.4% vs. 36.8%; p = 0.046). Multiple TLRs in individual patients were more frequent in the POBA group compared with the PCB group (more than 1 TLR: POBA, 13.2%; PCB, 1.4%; p = 0.021). The 36-month MACE rate was significantly reduced in the PCB group compared with the POBA group (20.8% vs. 52.6%, log-rank p = 0.001).ConclusionsPCB angioplasty was superior to POBA for the treatment of DES-ISR patients in terms of MACE and TLR for up to 36 months. There was no late catch-up phenomenon. (Treatment of Drug-eluting Stent [DES] In-Stent Restenosis With SeQuent® Please Paclitaxel Eluting Percutaneous Transluminal Coronary Angioplasty [PTCA] Catheter [PEPCAD-DES]; NCT00998439)  相似文献   

6.
ObjectivesThis study sought to compare the outcomes of fractional flow reserve (FFR)–guided and angiography (Angio)–guided provisional side-branch (SB) stenting for true coronary bifurcation lesions.BackgroundAngio-guided provisional SB stenting after stenting of the main vessel provides favorable outcomes for the majority of coronary bifurcation lesions. Whether an FFR-guided provisional stenting approach is superior has not been studied.MethodsA total of 320 patients with single Medina 1,1,1 and 0,1,1 coronary bifurcation lesions undergoing stenting with a provisional SB approach were randomly assigned 1:1 to Angio-guided and FFR-guided groups. SB stenting was performed for Thrombolysis In Myocardial Infarction flow grade <3, ostial SB stenosis >70%, or greater than type A dissection after main vessel stenting in the Angio-guided group and for SB-FFR <0.80 in the FFR-guided group. The primary endpoint was the 1-year composite rate of major adverse cardiac events (cardiac death, myocardial infarction, and clinically driven target vessel revascularization).ResultsComparing the Angio-guided and FFR-guided groups, treatment of the SB (balloon or stenting) was performed in 63.1% and 56.3% of lesions respectively (p = 0.07); stenting of the SB was attempted in 38.1% and 25.9%, respectively (p = 0.01); and, when attempted, stenting was successful in 83.6% and 73.3% of SBs, respectively (p = 0.01). The 1-year composite major adverse cardiac event rate was 18.1% in both groups (hazard ratio: 0.91, 95% confidence interval: 0.48 to 1.88; p = 1.00). The 1-year target vessel revascularization and stent thrombosis rates were 6.9% and 5.6% (p = 0.82) and 1.3% and 0.6% (p = 0.56) in the Angio-guided and FFR-guided groups, respectively.ConclusionsIn this multicenter, randomized trial, angiographic and FFR guidance of provisional SB stenting of true coronary bifurcation lesions provided similar 1-year clinical outcomes. (Randomized Study on DK Crush Technique Versus Provisional Stenting Technique for Coronary Artery Bifurcation Lesions; ChiCTR-TRC-07000015)  相似文献   

7.
ObjectivesThis study investigated the impact of final kissing ballooning (FKB) after main vessel (MV) stenting on outcomes in patients with coronary bifurcation lesions after application of the 1-stent technique.BackgroundAlthough FKB has been established as the standard method for bifurcation lesions treated with a 2-stent strategy, its efficacy in a 1-stent approach is highly controversial.MethodsThis study enrolled 1,901 patients with a bifurcation lesion with a side branch diameter ≥2.3 mm, treated solely with the 1-stent technique using a drug-eluting stent from 18 centers in Korea between January 1, 2003 and December 31, 2009. The primary outcome was major adverse cardiac events (MACE)—cardiac death, myocardial infarction, or target lesion revascularization. Propensity score-matching analysis was also performed.ResultsFKB was performed in 620 patients and the post minimal lumen diameter of the MV and side branch was larger in the FKB group than in the non-FKB group. During follow-up (median 36 months), the incidence of MACE (adjusted hazard ratio [HR]: 0.68, 95% confidence interval [CI]: 0.46 to 0.99; p = 0.048) was lower in the FKB group than the non-FKB group. After propensity score matching (545 pairs), the FKB group had a lower incidence of MACE (adjusted HR: 0.50, 95% CI: 0.30 to 0.85; p = 0.01), and target lesion revascularization in the MV (adjusted HR: 0.51, 95% CI: 0.28 to 0.93; p = 0.03) and both vessels (adjusted HR: 0.47, 95% CI: 0.25 to 0.90; p = 0.02) than in the non-FKB group.ConclusionsIn coronary bifurcation lesions, we demonstrated that the 1-stent technique with FKB was associated with a favorable long-term clinical outcome, mainly driven by the reduction of target lesion revascularization in the MV or both vessels as a result of an increase in minimal lumen diameter. (Korean Coronary Bifurcation Stenting Registry II [COBIS II]: NCT01642992)  相似文献   

8.
ObjectivesThis study aimed to investigate the clinical outcomes of patients presenting with recurrent drug-eluting stent (DES) in-stent restenosis (ISR) treated with a second-generation DES or with a drug-coated balloon (DCB).BackgroundTo date, there are no reports of DCB treatment and limited data with regard to the efficacy of further DES implantation for recurrent ISR.MethodsBetween January 2008 and December 2013, 171 lesions were assessed for eligibility (82 lesions in the second-generation DES group and 89 lesions in the DCB group).ResultsAcute gain was greater in the second-generation DES group (second-generation DES, 2.09 ± 0.53 mm vs. DCBs, 1.60 ± 0.62 mm, p < 0.001). The rates of major adverse cardiac events were comparable (at 1 year, DES 14.0% vs. DCBs 12.3%; at 2 years, DES 28.8% vs. DCBs 43.5%, p = 0.21). Major adverse cardiac event rates were mainly driven by target lesion revascularization (at 1 year, DES 12.5% vs. DCBs 10.9%; at 2 years, DES 27.7% vs. DCBs 38.3%; p = 0.40). Definite scaffold thrombosis occurred in 2 patients (1 patient in each group). Multivariable analysis revealed ISR recurrence within 1 year (hazard ratio: 2.43, 95% confidence interval: 1.14 to 5.18, p = 0.02) and lesion length (per 10-mm increase) (hazard ratio: 1.15, 95% confidence interval: 1.00 to 1.32, p = 0.049) to be independent predictors of TLR.ConclusionsThe results after both treatments were equivalent. ISR recurrence within 1 year of the first reintervention and lesion length were independent predictors of future target lesion revascularization. Larger studies are required to confirm the late (>1 year) differences with regard to clinical outcomes.  相似文献   

9.
ObjectivesThe authors sought to understand the clinical and angiographic outcomes of dissections left after drug-coated balloon (DCB) angioplasty.BackgroundSecond-generation DCB may be an alternative to stents in selected populations for the treatment of native coronary lesions. However, the use of these devices may be hampered by a certain risk of acute vessel recoil or residual coronary dissection. Moreover, stenting after DCB has shown limited efficacy. Little is known about when a non–flow-limiting dissection is left after DCB angioplasty.MethodsThis was a prospective observational study whose aim was to investigate the outcome of a consecutive series of patients with native coronary artery disease treated with second-generation DCB and residual coronary dissection at 2 Italian centers. We evaluated patient clinical conditions at 1 and 9 months, and angiographic follow up was undertaken at 6 months.ResultsBetween July 2012 and July 2014, 156 patients were treated with DCB for native coronary artery disease. Fifty-two patients had a final dissection, 4 of which underwent prosthesis implantation and 48 were left untreated and underwent angiographic follow-up after 201 days (interquartile range: 161 to 250 days). The dissections were all type A to C, and none determined an impaired distal flow. Complete vessel healing at angiography was observed in 45 patients (93.8%), whereas 3 patients had persistent but uncomplicated dissections, and 3 had binary restenosis (6.2%). Late lumen loss was 0.14 mm (−0.14 to 0.42). Major adverse cardiovascular events occurred in 11 patients in the entire cohort and in 4 of the dissection cohort (7.2% vs. 8.1%; p = 0.48). We observed 8 and 3 target lesion revascularizations, respectively (5.3% vs. 6.2%; p = 0.37).ConclusionsIn this cohort of consecutive patients treated with new-generation DCB and left with a final dissection, this strategy of revascularization seemed associated with the sealing of most of dissections and without significant neointimal hyperplasia.  相似文献   

10.
ObjectivesThis study sought to assess the incidence and clinical impact of stent fracture (SF) after the PROMUS Element platinum-chromium everolimus-eluting stent (PtCr-EES).BackgroundSF remains an unresolved, clinically relevant issue, even in the newer-generation drug-eluting stent era.MethodsFrom March 2012 to August 2013, 816 patients with 1,094 lesions were treated only with PtCr-EES and 700 patients (85.7%) with 898 lesions undergoing follow-up angiography within 9 months after the index procedure were analyzed. SF was defined as complete or partial separation of the stent, as assessed by plain fluoroscopy, intravascular ultrasound, or optical coherence tomography during the follow-up. We assessed the rate of SF and the cumulative incidence of clinically driven target lesion revascularization and definite stent thrombosis within 9 months after the index procedure.ResultsSF was observed in 16 of 898 lesions (1.7%) and 16 of 700 patients (2.2%). Lesions with in-stent restenosis at baseline (odds ratio [OR]: 14.2, 95% confidence intervals [CI]: 5.09 to 39.7; p < 0.001) or hinge motion (OR: 4.31, 95% CI: 1.12 to 16.5; p = 0.03), and total stent length (per 10-mm increase; OR: 1.32, 95% CI: 1.12 to 1.57; p = 0.001) were predictors of SF. Cumulative incidence of clinically driven target lesion revascularization within 9-months was numerically higher in the SF group than that in the non-SF group (18.7% vs. 2.3%). Cumulative incidence of definite stent thrombosis within 9 months after the index procedure was similar between the SF and non-SF groups (0.0% vs. 0.23%).ConclusionsSF after PtCr-EES occurs in 1.7% of lesions and appears to be associated with clinically driven target lesion revascularization.  相似文献   

11.
ObjectivesThe purpose of this study was to compare the long-term clinical outcomes of patients with chronic total occlusion (CTO) and well-developed collateral circulation treated with revascularization versus medical therapy.BackgroundLittle is known about the clinical outcomes and optimal treatment strategies of CTO with well-developed collateral circulation.MethodsWe screened 2,024 consecutive patients with at least 1 CTO detected on coronary angiogram. Of these, we analyzed data from 738 patients with Rentrop 3 grade collateral circulation who were treated with medical therapy alone (n = 236), coronary artery bypass grafting (n = 170) or percutaneous coronary intervention (n = 332; 80.1% successful). Patients who underwent revascularization and medical therapy (revascularization group, n = 502) were compared with those who underwent medical therapy alone (medication group, n = 236) in terms of cardiac death and major adverse cardiac events (MACE), defined as the composite of cardiac death, myocardial infarction, and repeat revascularization.ResultsDuring a median follow-up duration of 42 months, multivariate analysis revealed a significantly lower incidence of cardiac death (hazard ratio [HR]: 0.29; 95% confidence interval [CI]: 0.15 to 0.58; p < 0.01) and MACE (HR: 0.32; 95% CI: 0.21 to 0.49; p < 0.01) in the revascularization group compared with the medication group. After propensity score matching, the incidence of cardiac death (HR: 0.27; 95% CI: 0.09 to 0.80; p = 0.02) and MACE (HR: 0.44; 95% CI: 0.23 to 0.82; p = 0.01) were still significantly lower in the revascularization group than in the medication group.ConclusionsIn patients with coronary CTO and well-developed collateral circulation, aggressive revascularization may reduce the risk of cardiac mortality and MACE.  相似文献   

12.
ObjectivesThe present study established criteria to differentiate simple from complex bifurcation lesions and compared 1-year outcomes stratified by lesion complexity after provisional stenting (PS) and 2-stent techniques using drug-eluting stents.BackgroundCurrently, no criterion can distinguish between simple and complex coronary bifurcation lesions. Comparisons of PS and 2-stent strategies stratified by lesion complexity have also not been reported previously.MethodsCriteria of bifurcation complexity in 1,500 patients were externally tested in another 3,660 true bifurcation lesions after placement of drug-eluting stents. The primary endpoint was the occurrence of a major adverse cardiac event (MACE) at 12 months. The secondary endpoint was the rate of stent thrombosis (ST).ResultsComplex (n = 1,108) bifurcation lesions were associated with a higher 1-year rate of MACE (16.8%) compared with simple (n = 2,552) bifurcation lesions (8.9%) (p < 0.001). The in-hospital ST and 1-year target lesion revascularization rates after 2-stent techniques in the simple group (1.0% and 5.6%, respectively) were significantly different from those after PS (0.2% [p = 0.007] and 3.2% [p = 0.009], respectively); however, 1-year MACE rates were not significantly different between the 2 groups. For complex bifurcation lesions, 2-stent techniques had lower rates of 1-year cardiac death (2.8%) and in-hospital MACE (5.0%) compared with PS (5.3%, p = 0.047; 8.4%, p = 0.031).ConclusionsComplex bifurcation lesions had higher rates of 1-year MACE and ST. The 2-stent and PS techniques were overall equivalent in 1-year MACE. However, 2-stent techniques for complex lesions elicited a lower rate of cardiac death and in-hospital MACE but higher rates of in-hospital ST and revascularization at 1 year for simple lesions.  相似文献   

13.
ObjectivesThe aim of this study was to investigate the correlation between in-stent neointimal tissue without features of neoatherosclerosis and long-term clinical outcomes.BackgroundRecent studies have reported differential morphological characteristics of in-stent neointimal tissue assessed by optical coherence tomography (OCT).MethodsThe study population consisted of 336 patients with 368 drug-eluting stent-treated lesions. Patients received a follow-up OCT examination without any intervention. OCT-based neointima was categorized as homogeneous (n = 227 lesions in 208 patients), heterogeneous (n = 79 lesions in 73 patients), or layered (n = 62 lesions in 55 patients). Major adverse cardiac events (MACE) (a composite of cardiac death, nonfatal myocardial infarction, or target lesion revascularization) were assessed according to neointimal patterns during long-term clinical follow-up after OCT examination.ResultsThe time interval between stent implantation and OCT examination was similar among the 3 groups (p = 0.64). On multivariate logistic regression analysis, the significant determinant for the heterogeneous neointima was age (odds ratio [OR]: 1.037, 95% confidence interval [CI]: 1.007 to 1.068, p = 0.015) and an initial clinical presentation of acute coronary syndrome (OR: 1.967, 95% CI: 1.159 to 3.339, p = 0.012). The overall median follow-up duration for all patients after follow-up OCT examination was 31.0 months, and this was statistically different among the heterogeneous group (22.0 months), the homogeneous group (34.0 months), and the layered group (28.0 months, overall p = 0.002). MACE occurred more frequently in patients with heterogeneous neointima over a median 31-month follow-up period after OCT examination (13.7% vs. 2.9% in homogeneous vs. 7.3% in layered, p = 0.001). A propensity score–adjusted Cox regression analysis showed that independent risk factors for MACE were inclusion in the heterogeneous neointima (hazard ratio: 3.925, 95% CI: 1.445 to 10.662, p = 0.007) and minimal lumen cross-sectional area (hazard ratio: 0.368, 95% CI: 0.242 to 0.560, p < 0.001).ConclusionsDetermination of neointimal characteristics is helpful in predicting long-term clinical outcomes. Our data suggest that heterogeneous lesions are linked to poor long-term clinical prognoses.  相似文献   

14.
ObjectivesThe aim of this study was to investigate the hypothesis that a novel biodegradable polymer–coated, cobalt-chromium (CoCr), sirolimus-eluting stent (BP-SES) is noninferior in safety and efficacy outcomes compared with a durable polymer (DP)-SES.BackgroundNo randomized trials have the compared safety and efficacy of BP-SES versus DP-SES on similar CoCr platforms, thereby isolating the effect of the polymer type.MethodsIn this prospective, single-blind, randomized trial conducted at 32 Chinese sites, 2,737 patients eligible for coronary stenting were treated with BP- or DP-SES in a 2:1 ratio. The primary endpoint was 12-month target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or clinically indicated target lesion revascularization. Secondary endpoints included TLF components, and definite/probable stent thrombosis.ResultsAt 12 months, the difference in the primary endpoint of TLF between BP-SES (6.3%) and DP-SES (6.1%) groups was 0.25% (95% confidence interval: −1.67% to 2.17%, p for noninferiority = 0.0002), demonstrating noninferiority of BP-SES to DP-SES. Individual TLF components of cardiac death (0.7% vs. 0.6%, p = 0.62), target vessel myocardial infarction (3.6% vs. 4.3%, p = 0.39), and clinically indicated target lesion revascularization (2.6% vs. 2.2%, p = 0.50) were similar, as were low definite/probable stent thrombosis rates (0.4% vs. 0.6%, p = 0.55).ConclusionsIn this large-scale real-world trial, BP-SES was noninferior to DP-SES for 1-year TLF. (Evaluate Safety and Effectiveness of the Tivoli ® DES and the Firebird ® DES for Treatment of Coronary Revascularization; NCT01681381)  相似文献   

15.
ObjectivesThe purpose of this study was to analyze the effect of transcatheter aortic valve replacement (TAVR) without versus with prior balloon aortic valvuloplasty (BAV) on the risk of cerebral embolization in patients who receive a balloon-expandable valve.BackgroundAvoiding BAV prior to TAVR may simplify the procedure, but the risk of cerebral embolization is currently unknown.MethodsA total of 87 consecutive high surgical-risk patients with no contraindications for diffusion-weighted magnetic resonance imaging (DW-MRI) were enrolled. Thirty-two patients received a balloon-expandable aortic valve with and 55 patients without BAV. The incidence, number, and volume of new ischemic lesions in DW-MRI performed 2 to 7 days after TAVI were evaluated.ResultsMean age (83.8 ± 5.2 years vs. 82.9 ± 6.8 years) and sex (43.8% vs. 52.7% male) of the patients with versus without BAV, respectively, as well as other demographic and hemodynamic data were not significantly different between both groups. The procedural success rate was 93.5% with and 98.2% without BAV, and procedure duration and contrast volume were significantly lower without BAV. The incidence of new cerebral ischemic lesions in the total cohort was 66.7%. Compared with patients with BAV, those without BAV had a significantly higher total volume of cerebral ischemic lesions (235.4 ± 331.4 mm3 vs. 89.5 ± 128.2 mm3; p = 0.01).ConclusionsThe implantation of a balloon-expandable aortic valve without versus with prior BAV, although performed with a shorter procedure time and lower contrast volume, is associated with a significantly higher volume of cerebral ischemic lesions.  相似文献   

16.
ObjectivesThis study provides preliminary data on the safety and feasibility of the use of a novel focal implant for managing post–percutaneous transluminal balloon angioplasty (post-PTA) dissection.BackgroundPost-PTA dissection of the lower extremity arteries is managed with stent placement. This provides an acceptable post-intervention result but has long-term disadvantages, such as in-stent restenosis. Focal treatment of post-PTA dissection and avoidance of stents are the objectives of the Tack-It (Intact Vascular, Inc., Wayne, Pennsylvania) device.MethodsA preclinical study and first-in-human data are presented. Seven swine underwent superficial femoral artery device placement, with a self-expanding nitinol stent on 1 side and a series of 4 Tack-It devices on the other side. Specimens were harvested at 28 days. The clinical study included 15 limbs that underwent revascularization for critical limb ischemia (n = 9) or claudication (n = 6). Twenty-five lesions were treated in the superficial femoral (n = 8), popliteal (n = 7), and tibial (n = 10) arteries.ResultsThe preclinical study demonstrated a reduction in stenosis with the Tack-It (16.8 ± 2.6%) compared with stents (46.4 ± 9.8%). Neointimal thickness and injury score decreased with the Tack-It. Clinically, Tack-It placement resulted in acute technical success with resolution of the post-PTA dissection in 100% of lesions. There were no device-related complications or major amputations. Eighteen of the 25 lesions were available for angiographic follow-up at 1-year, and patency was 83.3%.ConclusionsPreclinical data suggest that the Tack-It device causes minimal vessel injury. Clinical use of the Tack-It to manage post-PTA dissection was safe and feasible in this early study and resulted in apposition of dissection flaps without stent placement.  相似文献   

17.
ObjectivesThe aim of this study was to assess the incidence and clinical impact of balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR) with the CoreValve prosthesis (Medtronic Inc., Minneapolis, Minnesota).BackgroundBPD is a widely adopted strategy to reduce the degree of paraprosthetic regurgitation in case of transcatheter heart valve underexpansion. However, controversies still remain regarding its real effectiveness and safety.MethodsThe ClinicalService (a nation-based data repository and medical care project) dataset was analyzed. All patients were dichotomized according to the need for BPD during the index procedure.ResultsAmong 1,376 patients, BPD of the transcatheter heart valve was performed in 272 (19.8%). In 37% of cases, it was unsuccessful at reducing the paravalvular regurgitation to mild or less. No case of valve embolization, new intravalvular regurgitation, coronary occlusion, and aortic root injury occurred during BPD. There were no statistically significant differences between the 2 groups in the incidence of in-hospital all-cause and cardiovascular mortality, neurological events, myocardial infarction, bleeding, conversion to open-chest surgery, and the need for a permanent pacemaker. The need for BPD did not emerge as an independent risk factor for all-cause (adjusted hazard ratio [HR]: 1.33, 95% confidence interval [CI]: 0.81 to 2.19, p = 0.264) and cardiovascular (adjusted HR: 1.48, 95% CI: 0.74 to 2.97, p = 0.265) mortality at 1 year after the procedure. In addition, BPD did not predispose to higher odds of neurological events during 12 months after TAVR (HR: 0.92, 95% CI: 0.45 to 1.88, p = 0.815).ConclusionsThis large study showed that BPD after TAVR was safe and not associated with increased rates of cerebrovascular events, mortality, myocardial infarction, and aortic root injury.  相似文献   

18.
ObjectivesThis study sought to compare the effect of paclitaxel-coated balloon (PCB) concentration on tissue levels and vascular healing using 3 different PCB technologies (In.Pact Pacific = 3 μg/mm2, Lutonix = 2 μg/mm2 and Ranger = 2 μg/mm2) in the experimental setting.BackgroundThe optimal therapeutic dose for PCB use has not been determined yet.MethodsPaclitaxel tissue levels were measured up to 60 days following PCB inflation (Ranger and In.Pact Pacific) in the superficial femoral artery of healthy swine (18 swine, 36 vessels). The familial hypercholesterolemic swine model of superficial femoral artery in-stent restenosis (6 swine, 24 vessels) was used in the efficacy study. Two weeks following bare-metal stent implantation, each in-stent restenosis site was randomly treated with a PCB or an uncoated control balloon (Sterling). Quantitative vascular analysis and histology evaluation was performed 28 days following PCB treatment.ResultsAll PCB technologies displayed comparable paclitaxel tissue levels 4 h following balloon inflation. At 28 days, all PCB had achieved therapeutic tissue levels; however, the In.Pact PCB resulted in higher tissue concentrations than did the other PCB groups at all time points. Neointimal inhibition by histology was decreased in all PCB groups compared with the control group, with a greater decrease in the In.Pact group. However, the neointima was more mature and contained less peri-strut fibrin deposits in both 2-μg/mm2 PCB groups.ConclusionsCompared with the clinically established PCB dose, lower-dose PCB technologies achieve lower long-term tissue levels but comparable degrees of neointimal inhibition and fewer fibrin deposits. The impact of these findings in restenosis reduction and clinical outcomes needs to be further investigated.  相似文献   

19.
ObjectivesThe aim of this meta-analysis was to evaluate and compare the efficacy of the 2 different neuroprotection systems in preventing embolization during carotid artery stenting (CAS), as detected by diffusion-weighted magnetic resonance imaging (DW-MRI).BackgroundData from randomized and nonrandomized studies comparing both types of embolic protection devices revealed contrasting evidence about their efficacy in neuroprotection, as assessed by the incidence of new ischemic lesions detected by DW-MRI.MethodsEight studies, enrolling 357 patients, were included in the meta-analysis. Our study analyzed the incidence of new ischemic lesions/patient, comparing filter cerebral protection and proximal balloon occlusion.ResultsFollowing CAS, the incidence of new ischemic lesions/patient detected by DW-MRI was significantly lower in the proximal balloon occlusion group (effect size [ES]: −0.43; 95% confidence interval [CI]: −0.84 to −0.02, I2 = 70.08, Q = 23.40). Furthermore, following CAS, the incidence of lesions at the contralateral site was significantly lower in the proximal protection group (ES: −0.50; 95% CI: −0.72 to −0.27, I2 = 0.00, Q = 3.80).ConclusionsOur meta-analysis supports the concept that the use of proximal balloon occlusion compared with filter cerebral protection is associated with a reduction of the amount of CAS-related brain embolization. The data should be confirmed by a randomized clinical trial.  相似文献   

20.
ObjectivesThe aim of this study was to assess outcomes after percutaneous coronary intervention (PCI) with stents in patients treated with thoracic external beam radiation therapy (EBRT).BackgroundThoracic EBRT for cancer is associated with long-term cardiotoxic sequelae. The impact of EBRT on patients requiring coronary stents is unclear.MethodsWe analyzed outcomes after PCI in cancer survivors treated with curative thoracic EBRT before and after stenting between 1998 and 2012. Reference groups were propensity-matched cohorts with stenting but no EBRT. Primary endpoint was target lesion revascularization (TLR), a clinical surrogate for restenosis. Secondary endpoints included myocardial infarction (MI) and cardiac and overall mortality.ResultsWe identified 115 patients treated with EBRT a median 3.6 years after stenting (group A) and 45 patients treated with EBRT a median 2.2 years before stenting (group B). Long-term mean TLR rates in group A (3.2 vs. 6.6%; hazard ratio: 0.6; 95% confidence interval: 0.2 to 1.6; p = 0.31) and group B (9.2 vs. 9.7%; hazard ratio: 1.2; 95% confidence interval: 0.4 to 3.4; p = 0.79) were similar to rates in corresponding control patients (group A: 1,390 control patients; group B: 439 control patients). Three years post-PCI, group A had higher overall mortality (48.6% vs. 13.9%; p < 0.001) but not MI (4.8% vs. 4.3%; p = 0.93) or cardiac mortality (2.3% vs. 3.6%; p = 0.66) rates versus control patients. There were no significant differences in MI, cardiac, or overall mortality rates in group B.ConclusionsThoracic EBRT is not associated with increased stent failure rates when used before or after PCI. A history of PCI should not preclude the use of curative thoracic EBRT in cancer patients or vice versa. Optimal treatment of cancer should be the goal.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号