首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Objectives

To analyze concordance between preoperative lymphoscintigraphy and intraoperative lymphatic mapping (ILM) for sentinel lymph node identification using technetium 99m-labeled-dextran 500 (99m-Tc) and patent blue dye in patients with early cervical cancer undergoing radical hysterectomy and pelvic lymphadenectomy, as well as to evaluate sentinel lymph node (SLN) detection.

Study design

Forty-seven patients underwent surgical treatment for cervical cancer. For SLN identification, 99m-Tc and blue patent were injected into the cervix on the eve and day of surgery, respectively. Preoperative pelvic lymphoscintigraphy was performed in all patients after 99m-Tc injection. Concordance between preoperative lymphoscintigraphy and ILM was evaluated.

Results

Of the 56 patients who underwent preoperative lymphoscintigraphy, 43 (81.13%) had at least one lymph node identified. Bilateral lymph nodes were identified in 21 (37.5%) patients. Sentinel lymph nodes detected on ILM had been previously found on preoperative lymphoscintigraphy in 66.7%, 67.2% and 0% in the right, left and central locations, respectively. In 14 patients (25%), only one lymph node was identified on preoperative lymphoscintigraphy, but more than one sentinel lymph node was detected on intraoperative mapping. In nine (16.1%) patients, lymphoscintigraphy showed only unilateral lymph nodes, but ILM identified bilateral sentinel lymph nodes.

Conclusion

The combination of patent blue and radionuclide techniques produced excellent results for SLN detection in cervical cancer. Preoperative lymphoscintigraphy does not offer any advantage over ILM for SLN identification.  相似文献   

2.
We studied the distribution of sentinel lymph nodes (SLNs) in vulvar cancer using blue dye and (99m)Tc radiocolloid and evaluated the techniques used, including the optimum timing of preoperative scintigraphy scans and its contribution to (99m)Tc SLN detection over that of the intraoperative handheld gamma probe. Fifty-nine women with squamous cell cancers <4 cm treated at our institution between December 2001 and December 2005 were included in this study. Blue dye alone was used in the first 16 women (group A) and the combination of (99m)Tc and blue dye was used on 43 women (group B). Of the 118 SLN detected in 82 groins, 83.9% (99) were sited in the superficial medial and intermediate inguinal chain, none were in superficial lateral groin, 16.1% (19) were deep femoral. The patient-specific SLN detection and false-negative rate in group B was 100% and 0%, compared to 68.8% (11/16 cases) and 6.3% (1/16) in group A. The optimum timing for preoperative lymphoscintigraphy scans was 45 min postinjection, but intraoperative use of the handheld gamma probe yielded 15% more "hot" nodes and allowed tailored placement of the lymphadenectomy incision. Eighty-four percent of SLNs were in the medial and intermediate region of the superficial inguinal chain, 16.1% were deep femoral. The combined use of (99m)Tc radiocolloid and blue dye was significantly superior at SLN detection than blue dye alone. (99m)Tc SLN detection using the intraoperative handheld probes was not enhanced by preoperative scintigraphy scans.  相似文献   

3.
BACKGROUND: The aim of the study was to demonstrate the validity of sentinel lymph node (SLN) detection after injection of radioactive isotope and patent blue dye in patients affected by early stage endometrial cancer. The second purpose was to compare radioactive isotope and patent blue dye migration. METHODS: Between September 2000 and May 2001, 11 patients with endometrial cancer FIGO stage Ib (n=10) and IIa (n=1) underwent laparoscopic SLN detection during laparoscopic assisted vaginal hysterectomy with bilateral salpingo-oophorectomy and pelvic bilateral systematic lymphadenectomy. Radioactive isotope injection was performed 24 ours before surgery and blue dye injection was performed just before surgery in the cervix at 3, 6, 9 and 12 hours. A 350 mm laparoscopic gamma-scintiprobe MR 100 type 11, (99m)Tc setted (Pol.Hi.Tech.), was used intraoperatively for detecting SLN. RESULTS: Seventeen SLN were detected at lymphoscintigraphy (6 bilateral and 5 monolateral). At laparoscopic surgery the same locations were found belonging at internal iliac lymph nodes (the so called "Leveuf-Godard" area, lateral to the inferior vescical artery, ventral to the origin of uterine artery and medial or caudal to the external iliac vein). Fourteen SLN were negative at histological analysis and only 3 positive for micrometastasis (mean SLN sections = 60. All the other pelvic lymph nodes were negative at histological analysis. The same SLN locations detected with g-scintiprobe were observed during laparoscopy after patent blue dye injection. CONCLUSIONS: If the sensitivity of the assessment of SLN is confirmed to be 100%, this laparoscopic approach could change the management of early stage endometrial cancer. The clinical validity of this technique must be evaluated prospectively.  相似文献   

4.
Sentinel lymph node detection in patients with endometrial cancer   总被引:15,自引:0,他引:15  
OBJECTIVE: The purpose of this study was to examine the feasibility of sentinel lymph node (SLN) detection in patients with endometrial cancer using preoperative lymphoscintigraphy and an intraoperative gamma probe. PATIENTS AND METHODS: Between June 2001 and January 2003, 28 consecutive patients with endometrial cancer who were scheduled for total abdominal hysterectomy, bilateral salpingo-oophorectomy, total pelvic lymphadenectomy, and paraaortic lymphadenectomy at Tohoku University School of Medicine underwent sentinel lymph node detection. On the day before surgery, preoperative lymphoscintigraphy was performed by injection of 99m-Technetium ((99m)Tc)-labeled phytate into the endometrium during hysteroscopy. At the time of surgery, a gamma-detecting probe was used to locate radioactive lymph nodes. RESULTS: At least one sentinel node was detected in each of 23 of the 28 patients (82%). The mean number of sentinel nodes detected was 3.1 (range, 1-9). Sentinel nodes could be identified in 21 of 22 patients (95%) whose tumor did not invade more than halfway into the myometrium. Eighteen patients had radioactive nodes in the paraaortic area. Most patients had a sentinel node in one of the following three sites: paraaortic, external iliac, and obturator. The sensitivity and specificity for detecting lymph node metastases were both 100%. CONCLUSION: The combination of preoperative lymphoscintigraphy with intraoperative gamma probe detection may be useful in identifying sentinel nodes in early-stage endometrial cancer.  相似文献   

5.
OBJECTIVE: The aim of our study was to compare the identification of sentinel lymph nodes (SLN) by blue dye and (99m) Tc; to evaluate detection rate per patient and specific side detection rate (SSDR) of SLN, distribution of SLN and distribution of positive SLN and false negative rate of the methods. PATIENTS AND METHODS: From February 2000 until September 2004, we included 183 women with early stage cervical carcinoma. We evaluated two methods of detection of SLN (100 cases by Patent blue, 83 cases by Patent blue with (99m)Tc). We stratified the group upon the size of the tumor and upon the type of surgical method (laparoscopy, laparotomy). RESULTS: SLN identification increased in cases when we used combination of both methods (Tc + blue dye) SSDR = 93% versus the use of blue dye only SSDR = 71% (OR:5,76, CI 95% -2.9 -11.4, <0.0001). Distribution of 462 SLN-45.0% external iliac artery and vein, 42.6% supraobturator, 4.8 bifurcation and common illiac artery and vein, 4.6% praesacral, 3% medial part of lateral parametrium. Distribution of 44 positive SLN-approximately 38.6% external illiac artery and vein, 45.5% supraobturator, 6.8% bifurcation and common illiac artery and vein, 4.5% praesacral, 4.5% medial part of lateral parametrium. One false negative SN was in presacral area. CONCLUSION: Detection of SLN by combination of (99m)Tc and blue dye was statistically significantly better than blue dye alone. Our study documents high sensitivity, specificity and low false negativity of the method.  相似文献   

6.
OBJECTIVE: To determine the feasibility of intraoperative radioisotopic mapping using an endoscopic gamma probe associated with patent blue dye injection in patients with early stage cervical cancer. METHODS: Between April 2001 and March 2002 a total of 12 patients underwent laparoscopic bilateral pelvic lymphadenectomy (squamous carcinoma in 10 cases, all stage FIGO IB1, and adenocarcinoma in 2 cases, stages IA2 and IB1). Lymphoscintigraphies were performed on the day before surgery to visualize sentinel lymph nodes, 31 +/- 22.5 and 174 +/- 34 min after injection of 200 microCi of technetium 99m rhenium sulfur colloid. The marker was injected at the 3, 6, 9, and 12 o'clock positions. The day of surgery 2 ml of patent blue dye plus 2 ml of physiological serum was injected in the cervix, at the same locations as the radioactive isotope injection. RESULTS: A total of 35 sentinel lymph nodes were detected. Eight sentinel lymph nodes were only detected by color, 8 sentinel lymph nodes were only detected by the endoscopic gamma probe, and 19 sentinel lymph nodes were "hot and dyed." We found 3 metastatic lymph nodes. In one case, bilateral positive sentinel nodes were only detected by the endoscopic gamma probe. Permanent section identified one inframillimetric micrometastasis in a lymph node that was neither blue nor hot intraoperatively (sensitivity = 66%, specificity = 100%, positive predictive value = 100%, negative predictive value = 90%). CONCLUSION: The identification of the sentinel lymph node with blue dye and radioisotope using an endoscopic gamma probe is feasible and improves detection rate. False negatives still occur, but the proportion is low even at the beginning of the learning curve. Isotopic imaging identifies nodes in areas outside the pelvis not routinely sampled in early cervical cancer patients.  相似文献   

7.
子宫颈癌根治术中的淋巴显影和前哨淋巴结识别   总被引:21,自引:1,他引:20  
目的 探索子宫颈癌根治术中淋巴显影和前哨淋巴结识别的方法及其可行性,评价前哨淋巴结预测盆腔淋巴结有无肿瘤转移的准确性。方法 应用染料法对20例宫颈癌患者(临床分期为Ib期3例、Ⅱa期12例、Ⅱb期5例)在根治术中于宫颈肿瘤周围的正常组织中分4点(3、6、9、12点处)注入美蓝或专利蓝溶液4ml,识别和定位蓝染的淋巴结(即前哨淋巴结),然后再按常规行盆腔淋巴清扫术,所有淋巴结一起送病理检查。结果 20例宫颈癌患者中淋巴管有蓝色染料摄取者18例,共有蓝染淋巴结33枚,其中左侧15枚,右侧18枚,前哨淋巴结识别成功14例,识别率为78%(14/18)。共有6例有淋巴结转移,淋巴结转移率为33%(6/18)。成功识别前哨淋巴结的14例中,淋巴结转移5例,其中前哨淋巴结和盆腔淋巴结均转移者2例,仅有前哨淋巴结转移者3例,准确性为100%,假阴性率为0。结论 宫颈癌根治术中淋巴显影和前哨淋巴结识别技术是可行的,但识别率尚有待提高。  相似文献   

8.
Sentinel lymph node detection in patients with cervical cancer   总被引:42,自引:0,他引:42  
PURPOSE: We investigated the validity of sentinel lymph node (SLN) detection after radioactive isotope and/or blue dye injection in patients with cervical cancer. PATIENTS AND METHODS: Between December 1998 and May 2000, 50 patients (mean age 44 years) with cervical cancer FIGO stage I (n = 32), stage II (n = 16), or stage IV (n = 2) underwent SLN detection during primary operation (radical laparoscopic-vaginal or abdominal hysterectomy, exenteration). The day before surgery 1 ml of Albu-Res labeled with 50 MBq Technetium 99m was applied into the cervix at 3(00), 6(00), 9(00), and 12(00). Blue dye injection (Patentblue) occurred intraoperatively into the cervix at the same locations. RESULTS: The detection rate of SLN was 78%. Ten patients (20.0%) were diagnosed with lymph node metastases. No SLN was detected in 10 patients, of which 4 patients had positive lymph nodes. Sensitivity and negative predictive value were 83.3 and 97.1%, respectively. The false-negative rate was 16.6% (1 of 6 patients). After the combined injection, the detection rate, sensitivity, and negative predictive values were 100%. A mean of 2.7 pelvic and 2.6 para-aortic SLNs were detected. Para-aortic SLNs were located in the paracaval region in 66.6%, whereas pelvic SLNs were detected in 25.7% at the origin of the uterine artery and in 24.7% at the division of the common iliac artery. CONCLUSION: A combination of radioactively labeled albumin with blue dye allows successful detection of SLN in patients with cervical cancer. The clinical validity of this technique must be evaluated prospectively.  相似文献   

9.
OBJECTIVES: Validity of the sentinel node concept in patients with cervical, endometrial and vulvar cancer. MATERIAL AND METHODS: 47 cases of FIGO stage I and II cervical cancer, 33 cases of first clinical stage of endometrial cancer and 37 patients with FIGO stage I and II of vulvar cancer. In cervical and vulvar cancer preoperative lymphoscyntygraphy and intraoperative lymphatic mapping with blue dye and handheld gamma probe were performed. In patients with endometrial cancer intraoperative lymphatic mapping with blue dye injected into the cervix and into the uterine corpus subserously were done. In the last 10 cases radiolabeled nannocolloid were administered and the patients underwent preoperative lymphoscyntygraphy and intraoperative radio detection of sentinel node. Sentinel nodes were labeled as blue, radioactive, or blue/radioactive. RESULTS: In cervical cancer sensitivity of the dye and radiocolloid methods was 94%, specificity 100% and negative predictive value 97%. Out of 33 cases of endometrial cancer sentinel node was identified in 29 (87.87%) patients. None of women with histological negative sentinel node had metastases in the rest of lymph nodes resected. Sentinel node was detected in all cases of vulvar cancer. The status of sentinel nodes were representative for all lymph node resected. CONCLUSIONS: Concept of sentinel node may be applied first of all for vulvar cancer and also for cervical and endometrial cancer.  相似文献   

10.
OBJECTIVES: The main study objective was to describe the distribution of sentinel lymph nodes (SLNs) and the prevalence of SLN micrometastases in patients with early cervical cancer. The secondary objective was to confirm the SLN detection rate and negative predictive value found in our preliminary study. PATIENTS AND METHODS: We prospectively included 25 patients with early cervical cancer, each of whom received an injection of 120 MBq of technetium-99m for preoperative lymphoscintigraphy and intraoperative node detection using an endoscopic gamma probe. Patent blue dye was injected intraoperatively. SLNs were sought in the pelvic and para-aortic drainage areas. Radical iliac dissection was performed routinely at the end of the procedure. SLNs were examined after hematoxylin-eosin-saffron staining; negative specimens were assessed using immunohistochemistry. RESULTS: Most (85%) of the SLNs were in the inter-iliac territory. Para-aortic or parametrial SLNs were found respectively in 2 patients and common iliac SLNs in 5 patients. Thus 9/25 patients had additional information due to SLN detection. One metastasis and one micrometastasis were detected in SLNs. No patients had positive non-sentinel nodes with negative SLNs. CONCLUSION: SLN detection ensures the identification of SLNs in unusual locations in 36% of patients. SLN disease was found in 8% of our patients. Thus, SLN biopsy improves staging in patients with early cervical cancer. Studies in larger patient populations are needed to evaluate the clinical impact of SLN biopsy.  相似文献   

11.
Sentinel node detection in cervical cancer   总被引:19,自引:0,他引:19  
BACKGROUND: For superficial tumors such as melanoma, breast, and vulvar cancer, sentinel node detection prevents unnecessary extensive lymph node dissections. Sentinel node detection has not yet proved feasible in tumors, such as cervical cancer, that drain to deep pelvic lymph nodes. TECHNIQUE: We injected technetium-99m colloidal albumin around the tumor allowing preoperative lymphscintigraphy and intraoperative gamma probe detection of sentinel nodes. For visual detection, blue dye was injected at the start of surgery. EXPERIENCE: In six of 10 eligible women who had Wertheim-Meigs operations for cervical cancer stage Ib, one or more sentinel nodes could be detected by scintigraphy. Intraoperative gamma probe detection was successful in eight of ten women, whereas visual detection found sentinel nodes in only four. They were found as far as the common iliac level. One woman had positive lymph nodes, of which one was a sentinel node. CONCLUSION: Identification of sentinel nodes using radionuclide is possible in women with cervical cancer and potentially identifies women in whom lymph node dissection can be avoided.  相似文献   

12.
OBJECTIVE: To evaluate the feasibility of sentinel lymph node (SLN) detection in patients with cervical cancer using the low-cost methylene blue dye and to optimize the application procedure. PATIENTS AND METHODS: Patients with stage Ib(1)-IIa cervical cancer and subjected to abdominal radical abdominal hysterectomy and pelvic lymphadenectomy were enrolled. Methylene blue, 2-4 ml, was injected into the cervical peritumoral area in 77 cases (4 ml patent blue in the other four cases) 10-360 min before the incision, and surgically removed lymph nodes were examined for the blue lymph nodes that were considered as SLNs. RESULTS: High SLN detection rate was successfully achieved when 4 ml of methylene blue was applied (93.9%, 46/49). Bilaterally SLN detection rate was significantly higher (78.1% vs. 47.1% P=0.027) in cases when the timing of application was more than 60 min before surgery than those with timing no more than 30 min. The blue color of methylene blue-stained SLNs sustained both in vivo and ex vivo, compared with the gradually faded blue color of patent blue that detected in 3 of 4 cases unilaterally. In the total of 112 dissected sides, the most common location of SLNs was the obturator basin (65.2%, 73/112), followed by external iliac area (30.4%, 34/112) and internal iliac area (26.8%, 30/112). Three patients who gave false negative results all had enlarged nodes. CONCLUSION: Methylene blue is an effective tracer to detect SLNs in patients with early stage cervical cancer. The ideal dose and timing of methylene blue application are 4 ml and 60-90 min prior surgery, respectively.  相似文献   

13.

Objective

The objective of this study is to evaluate the detection rate and diagnostic accuracy of sentinel lymph node (SLN) mapping using intra-operative cervical injection of filtered 99mTc-sulfur colloid (99mTc-SC) and patent blue in patients with endometrial cancer.

Methods

Prospective evaluation of the first 100 endometrial cancer patients undergoing SLN mapping using cervical injection of patent blue combined with filtered 99mTc-SC in the operating room was done. Patients underwent robotic-assisted lymphatic mapping with frozen section, hysterectomy, BSO, and completion bilateral lymphadenectomy (including para-aortic nodes in grade 2 and 3 tumors).

Results

At least one SLN was detected in 92% of patients; in 66 of these (72%) bilateral SLN were detected, and in 15 cases the SLN was in the para-aortic area. Eleven percent of all patients had lymph node metastases, and 4 of which had pre-operative grade 1 tumor. The SLN was the only positive node in 44% of the cases with positive nodes. Sensitivity was 89% with 1 false negative result, yielding a negative predictive value of 99% (95% CI 93-100). Specificity was 100% (95% CI 94-100), and positive predictive value was 100% (95% CI 60-100). No complications or anaphylactic reactions were noted.

Conclusions

Intra-operative SLN biopsy, using cervical injection of patent blue and filtered 99mTc-SC in endometrial cancer patients is feasible and yields adequate detection rates.  相似文献   

14.
Sentinel node detection in cervical cancer with (99m)Tc-phytate   总被引:2,自引:0,他引:2  
OBJECTIVES: The aim of this study was to investigate the feasibility of sentinel lymph node (SLN) identification using radioisotopic lymphatic mapping with technetium-99 m-labeled phytate in patients undergoing radical hysterectomy with pelvic lymphadenectomy for treatment of early cervical cancer. METHODS: Between July 2001 and February 2003, 56 patients with cervical cancer FIGO stage I (n = 53) or stage II (n = 3) underwent sentinel lymph node detection with preoperative lymphoscintigraphy ((99m)Tc-labeled phytate injected into the uterine cervix, at 3, 6, 9, and 12 o'clock, at a dose of 55-74 MBq in a volume of 0.8 ml) and intraoperative lymphatic mapping with a handheld gamma probe. Radical hysterectomy was aborted in three cases because parametrial invasion was found intraoperatively and we performed only sentinel node resection. The remaining 53 patients underwent radical hysterectomy with complete pelvic lymphadenectomy. Sentinel nodes were detected using a handheld gamma-probe and removed for pathological assessment during the abdominal radical hysterectomy and pelvic lymphadenectomy. RESULTS: One or more sentinel nodes were detected in 52 out of 56 eligible patients (92.8%). A total of 120 SLNs were detected by lymphoscintigraphy (mean 2.27 nodes per patient) and intraoperatively by gamma probe. Forty-four percent of SLNs were found in the external iliac area, 39% in the obturator region, 8.3% in interiliac region, and 6.7% in the common iliac area. Unilateral sentinel nodes were found in thirty-one patients (59%). The remaining 21 patients (41%) had bilateral sentinel nodes. Microscopic nodal metastases were confirmed in 17 (32%) cases. In 10 of these patients, only SLNs had metastases. The 98 sentinel nodes that were negative on hematoxylin and eosin were submitted to cytokeratin immunohistochemical analysis. Five (5.1%) micrometastases were identified with this technique. The sensitivity of the sentinel node was 82.3% (CI 95% = 56.6-96.2) and the negative predictive value was 92.1% (CI 95% = 78.6-98.3). The accuracy of sentinel node in predicting the lymph node status was 94.2%. CONCLUSION: Preoperative lymphoscintigraphy and intraoperative lymphatic mapping with (99m)Tc-labeled phytate are effective in identifying sentinel nodes in patients undergoing radical hysterectomy and to select women in whom lymph node dissection can be avoided.  相似文献   

15.
OBJECTIVES: We investigated the feasibility of sentinel lymph node identification using radioisotopic lymphatic mapping with technetium-99m-labeled human serum albumin and isosulfan blue dye injection in patients undergoing radical hysterectomy with pelvic lymphadenectomy for treatment of early cervical cancer. METHODS: Between September 2000 and October 2002, 25 patients with cervical cancer FIGO stage I (n=24) or stage II (n=1) underwent sentinel lymph node detection with preoperative lymphoscintigraphy (technetium-99m colloid albumin injection around the tumor) and intraoperative lymphatic mapping with blue dye and a handheld or laparoscopic gamma probe. Complete pelvic or paraaortic lymphadenectomy was performed in all cases by open surgery or laparoscopic surgery. RESULTS: In 23 evaluable patients, a total of 51 sentinel lymph nodes were detected by lymphoscintigraphy (mean 2.21 nodes per patient). Intraoperatively, 61 sentinel lymph nodes were identified, with a mean of 2.52 nodes per patient by gamma probe and a mean of 1.94 nodes per patient after isosulfan blue injection. Forty percent of sentinel nodes were found in the interiliac region and 25% in the external iliac area. Microscopic nodal metastases (four nodes) were confirmed in 12% of cases. All these lymph nodes were previously detected as sentinel lymph nodes. The remaining 419 nodes after pelvic lymphadenectomy were histologically negative. CONCLUSIONS: Sentinel lymph node identification with technetium-99m-labeled nanocolloid combined with blue dye injection is feasible and showed a 100% negative predictive value, and potentially identified women in whom lymph node dissection can be avoided.  相似文献   

16.

Objective

The aim of this study was to investigate the feasibility of the sentinel lymph node (SLN) identification with SPECT/CT lymphoscintigraphy imaging in the early stage invasive cervical cancer in patients undergoing radical hysterectomy and pelvic lymphadenectomy.

Methods

Between March 2007 and June 2009, a prospective consecutive study was designed for SLN mapping. Twenty-two patients with cervical cancer FIGO stage IB1 (n = 20) or stage IIA1 (n = 2) underwent SLN identification with preoperative SPECT/CT and planar images (technetium-99 m colloid albumin injection around the tumor) and posterior intraoperative detection with both blue dye and a handheld or laparoscopic gamma probe. Complete pelvic lymphadenectomy was performed in all cases by open (n = 2) or laparoscopic (n = 20) surgery.

Results

In the present series, a total of 35 SLN were detected with planar images and 40 SLN were identified and well located by SPECT/CT lymphoscintigraphy (median 2.0 nodes per patient). In 5/22 patients (22.7%) SPECT/CT procedure improves the number of localized SLN. Intraoperatively, 57 SLNs were identified, with a median of 3 SLNs per patient by gamma probe (a total of 53 hot nodes) and a median of 2 nodes per patient after blue dye injection (a total of 42 blue nodes). Microscopic nodal metastases (eight nodes, corresponding to four patients) were confirmed in 18.18% of cases; all these lymph nodes were previously detected as SLN. The remaining 450 nodes, including SLNs, following complete pelvic lymphadenectomy, were histologically negative.

Conclusions

Sentinel lymph node detection is improved by SPECT/CT imaging because of the increased number of SLN detected and the better tridimensional anatomic location, allowing easier intra-operative detection with gamma probe and showing, in this series, a 100% negative predictive value.  相似文献   

17.

Objective

The aim of the present study was to clarify the most effective combination of injected tracer types and injection sites in order to detect sentinel lymph nodes (SLNs) in early endometrial cancer.

Patients and methods

The study included 100 consecutive patients with endometrial cancer treated at Tohoku University Hospital between June 2001 and December 2012. The procedure for SLN identification entailed either radioisotope (RI) injection into the endometrium during hysteroscopy (55 cases) or direct RI injection into the uterine cervix (45 cases). A combination of blue dye injected into the uterine cervix or uterine body intraoperatively in addition to preoperative RI injection occurred in 69 of 100 cases. All detected SLNs were recorded according to the individual tracer and the resultant staging from this method was compared to the final pathology of lymph node metastases including para-aortic nodes.

Results

SLN detection rate was highest (96%) by cervical RI injection; however, no SLNs were detected in para-aortic area. Para-aortic SLNs were detected only by hysteroscopic RI injection (56%). All cases with pelvic lymph node metastases were detected by pelvic SLN biopsy. Isolated positive para-aortic lymph nodes were detected in 3 patients. Bilateral SLN detection rate was high (96%; 26 of 27 cases) by cervical RI injection combined with dye.

Conclusion

RI injection into the uterine cervix is highly sensitive in detection of SLN metastasis in early stage endometrial cancer. It is a useful and safe modality when combined with blue dye injection into the uterine body.  相似文献   

18.

Objectives

To compare the relative value of two methods of detection for the sentinel lymphatic nodes (SLNs): colorimetric with Isosulfan blue (ISB) and radio-isotopic with Technetium-99 (Tc99), and to evaluate the concept of the SLN mapping applied to cervical cancer.

Methods

From October 2000 to December 2006, radical surgery was planned in 211 patients who presented early-stage cancer of the cervix. Both ISB and Tc99 were used to detect the SLNs. In all cases, we proceeded with laparoscopy for the identification and removal of the SLNs, followed by a complete pelvic lymphadenectomy with or without para-aortic node sampling. The SLNs were sent for frozen section (1 level) and were ultra-staged (6 levels) for final pathology. Detection rate, sensitivity and negative predictive value (NPV) were calculated.

Results

Among the 211 patients, ISB (n = 152) identified at least 1 SLN in 92.8% of the cases. With Tc99 (n = 166), the detection rate of SLN increased to 96.9%. When both techniques were used together (n = 107), Tc99 was significantly better than ISB by 7.8% (p = 0.0094) and at least 1 SLN (hot and/or blue) was found in 99.1% of the cases. In 16.7% of patients, a SLN was located in aberrant sites, including 3.8% in the para-aortic area. Thirty-three out of the 211 patients (15.6%) had lymph node metastases. When considering only the 181 patients with bilateral SLNs identified, the NPV of SLN is 100% after ultra staging on final pathology and 94.2% on frozen section (FS).

Conclusion

Sentinel node mapping is feasible using laparoscopy. The radio-isotopic technique adds significantly to the rate of detection. The main benefits of SLN mapping in cervical cancer are the detection of micro-metastases on ultra staging which might be missed on routine pathological evaluation, and identification of aberrant drainage sites. However, the current frozen section techniques lack sensitivity to identify very small metastases and need refinement. SLN mapping should become the standard of care in the modern management of cervical cancer and complete pelvic lymphadenectomy could be avoided when bilateral SLNs are detected in patients with lesions less than 2 cm.  相似文献   

19.
OBJECTIVE: The aim of this study was to investigate the feasibility of sentinel node detection with the blue dye technique in early cervical cancer. METHODS: In a retrospective study conducted between January 2000 and February 2005, 47 women with early cervical cancer (6 patients FIGO Stage I A, 38 patients FIGO Stage I B, 2 patients FIGO Stage II A, 1 patient FIGO Stage II B) who underwent class II-III radical hysterectomy with pelvic lymphadenectomy were identified. Prior to surgery 1 ml of blue dye (lymphazurin 1%) was injected into the four quadrants of the cervix. RESULTS: The detection rate for sentinel nodes was 83% (39/47 patients). The median number of sentinel lymph nodes per patient was two. Nine patients had positive sentinel nodes. In one patient the sentinel lymph node procedure revealed to be false-negative. Positive predictive value and specificity were both 100%. The sensitivity and negative predictive value were 90% and 97%, respectively. CONCLUSIONS: Sentinel node detection has become a main field of interest in gynecological oncology. Our detection rate and sensitivity rate using the blue dye technique in cervical cancer are comparable to those in previously published data. However, recent data on a combined radioactively labeled albumin and blue dye technique show even more promising results. The clinical validity of the combined techniques must be evaluated prospectively in larger studies.  相似文献   

20.
Study ObjectiveTo determine whether the concomitant use of indocyanine green (ICG) with technetium-99m–filtered sulfur colloid (Tc99m-FSC) improves bilateral sentinel lymph node (SLN) detection rate in endometrial cancer and whether anatomic concordance of pelvic lymph nodes exists and can be used to predict SLN location in cases of unilateral mapping failure.DesignRetrospective cohort study.SettingTertiary academic medical center in Holon, Israel.PatientsPatients diagnosed with endometrial cancer, who underwent SLN mapping with Tc99m-FSC, ICG, or both, at our center between 2014 and 2019.InterventionsA total of 111 patients were included in the study. SLN mapping using Tc99m-FSC was performed in 101 (91.9%) patients, and ICG injection was given to 64 (57.6%) patients of whom 55 (49.5%) received both. We compared SLN detection rates (unilateral and bilateral) and anatomic symmetry for each method alone and for a combination of the 2.Measurements and Main ResultsThe overall detection rate for unilateral SLNs was 96.4%; 96.9% with ICG, 93.1% with gamma-probe, and 98.2% by combining both methods. The total bilateral detection rate was 72.1%, with ICG performing better as a single tracer than Tc99m-FSC (75% vs 63.4%, respectively). In 55 women in whom both tracers were used, the bilateral detection rate was significantly higher compared with Tc99m-FSC alone. Symmetric pelvic anatomic concordance of SLN was found in only 35 of 80 patients with bilateral SLN detection (43.8%).ConclusionThe combination of preoperative radioisotope injection and intraoperative ICG administration may yield the best bilateral SLN detection rate. In cases of unilateral mapping failure, one cannot rely on the anatomic location of the ipsilateral SLN detected to harvest the complementary node because the symmetric concordance is poor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号