首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
2.

Objective

To assess the diagnostic value of automated breast volume scanning (ABVS) or conventional handheld ultrasonography (HHUS) for the differentiation of benign and malignant breast lesions.

Materials and methods

The study prospectively evaluated 239 lesions in 213 women who were scheduled for open biopsy. The patients underwent ABVS and conventional HHUS. The sensitivity, specificity, accuracy, false positive rate, false negative rate, and positive and negative predictive values for HHUS and ABVS images were calculated using histopathological examination as the gold standard. Additionally, diagnostic accuracy was further evaluated according to the size of the masses.

Results

Among the 239 breast lesions studied, pathology revealed 85 (35.6%) malignant lesions and 154 (64.4%) benign lesions. ABVS was similar to HHUS in terms of sensitivity (95.3% vs. 90.6%), specificity (80.5% vs. 82.5%), accuracy (85.8% vs. 85.3%), positive predictive value (73.0% vs. 74.0%), and negative predictive value (93.3% vs. 94.1%). The area under the receiver operating characteristic (ROC) curve, which is used to estimate the accuracy of the methods, demonstrated only minor differences between HHUS and ABVS (0.928 and 0.948, respectively).

Conclusions

The diagnostic accuracy of HHUS and ABVS in differentiating benign from malignant breast lesions is almost identical. However, ABVS can offer new diagnostic information. ABVS may help to distinguish between real lesions and inhomogeneous areas, find small lesions, and demonstrate the presence of intraductal lesions. This technique is feasible for clinical applications and is a promising new technique in breast imaging.  相似文献   

3.

Objectives

Handheld breast ultrasound (HHUS) lacks standardization and reproducibility. The automated breast volume scanner (ABVS) could overcome this limitation. To analyze the interobserver reliability of ABVS and the agreement with HHUS, mammography and pathology is the aim of this study.

Methods

All 42 study participants (=84 breasts) received an ABVS examination in addition to the conventional breast diagnostic work-up. 25 breasts (30%) showed at least one lesion. The scans were interpreted by six breast diagnostic specialists blinded to results of breast imaging and medical history. 32 lesions received histological work-up: 20 cancers were detected. We used kappa statistics to interpret agreement between examiners and diagnostic instruments.

Results

On the basis of the Breast Imaging Reporting and Data System (BI-RADS) classification of the 84 breasts an agreement (defined as ≥4 of 6 examiners) was achieved in 63 cases (75%) (mk = 0.35) and even improved when dichotomizing the interpretation in benign (BI-RADS 1, 2) and suspicious (BI-RADS 4, 5) to 98% (mk = 0.52). Agreement of ABVS examination to HHUS, mammography and pathology was fair to substantial depending on the specific analysis.

Conclusions

The development of an ABVS seems to be a promising diagnostic method with a good interobserver reliability, as well as a comparable good test criteria as HHUS.  相似文献   

4.

Objective

We wanted to evaluate the image quality and diagnostic value of 64-slice dual-source computed tomography (DSCT) coronary angiography in patients with atrial fibrillation (Afib).

Materials and Methods

The coronary arteries of 22 Afib patients seen on DSCT were classified into 15 segments and the imaging quality (excellent, good, moderate and poor) and significant stenoses (≥ 50%) were evaluated by two radiologists who were blinded to the conventional coronary angiography (CAG) results. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for detecting important coronary artery stenosis were calculated. McNemar test was used to determine any significant difference between DSCT and CAG, and Cohen''s Kappa statistics were calculated for the intermodality and interobserver agreement.

Results

The mean heart rate was 89 ± 8.3 bpm (range: 80-118 bpm). A range from 250 msec to 300 msec within the RR interval was the optimal reconstruction interval for the patients with Afib. The respective overall sensitivity, specificity, PPV and NPV values were 74%, 97%, 81% and 96% for reader 1 and 72%, 98%, 85% and 96% for reader 2. No significant difference between DSCT and CAG was found for detecting a significant stenosis (reader 1, p = 1.0; reader 2, p = 0.727). Cohen''s Kappa statistics demonstrated good intermodality and interobserver agreement.

Conclusion

64-slice DSCT coronary angiography provides good image quality in patients with atrial fibrillation without the need for controlling the heart rate. DSCT can be used for ruling out significant stenosis in patients with atrial fibrillation with its high NPV for detecting in important stenosis.  相似文献   

5.

Objective

To evaluate the nature and imaging appearance of incidental enhancing breast lesions detected on a routine contrast-enhanced chest CT.

Materials and Methods

Twenty-three patients with incidental enhancing breast lesions on contrast-enhanced chest CT were retrospectively reviewed. The breast lesions were reviewed by unenhanced and enhanced CT, and evaluated by observing the shapes, margins, enhancement patterns and backgrounds of breast lesions. A histopathologic diagnosis or long-term follow-up served as reference standard.

Results

Sixteen (70%) patients had malignant breast lesions and seven (30%) had benign lesions. In 10 patients, the breast lesions were exclusively detected on contrast-enhanced CT. Using unenhanced CT, breast lesions with fibroglandular backgrounds were prone to be obscured (p < 0.001). Incidental primary breast cancer showed an non-significant trend of a higher percentage irregular margin (p = 0.056). All of the four incidental breast lesions with non-mass-like enhancement were proven to be malignant.

Conclusion

Routine contrast-enhanced chest CT can reveal sufficient details to allow for the detection of unsuspected breast lesions, in which some cases may be proven as malignant. An irregular margin of incidental enhancing breast lesion can be considered a suggestive sign of malignancy.  相似文献   

6.

Objectives

To retrospectively investigate the added value of kinetic features measured by computer-aided diagnosis (CAD) for differentiating benign and malignant contralateral breast lesions detected by preoperative MRI in breast cancer patients.

Methods

This study was approved by our institutional review board, and the requirement for informed consent was waived. Fifty-two breast MR images and their CAD kinetic features were obtained for 52 consecutive breast cancer patients with contralateral breast lesions detected by preoperative MRI and confirmed by excision (23 cancers and 29 benign lesions). Three experienced radiologists independently reviewed the MR images without CAD information and assessed probabilities of malignancy. Four weeks later, these probabilities were reanalyzed using stored CAD data. Diagnostic performances and detection rates of delayed washout components were compared between interpretations without and with CAD for each reader.

Results

Use of MR CAD increased detection of washout component by 2.4- to 3.7-fold than visual assessment for enhancing contralateral lesions, which increased sensitivity (91% vs. 87% in reader 1; 96% vs. 74% in reader 2; 91% vs. 70% in reader 3) and decreased specificity, but statistical significance was only found for decreased specificity in one reader (52% vs. 28%, P = 0.039), and overall performance (areas under ROC curves 0.672 vs. 0.616 in reader 1; 0.624 vs. 0.603 in reader 2; 0.706 vs. 0.590 in reader 3) remained unimproved.

Conclusion

Addition of MR CAD increased sensitivity and decreased specificity than radiologist's assessment alone for differentiating benign and malignant contralateral lesions in breast cancer patients and overall performance remained unimproved.  相似文献   

7.

Objectives

This study aimed to evaluate automated breast ultrasound (ABUS) compared to hand-held traditional ultrasound (HHUS) in the visualisation and BIRADS characterisation of breast lesions.

Materials and methods

From January 2016 to January 2017, 1,886 women with breast density category C or D (aged 48.6±10.8 years) were recruited. All participants underwent ABUS and HHUS examination; a subcohort of 1,665 women also underwent a mammography.

Results

The overall agreement between HHUS and ABUS was 99.8 %; kappa=0.994, p<0.0001. Two cases were graded as BI-RADS 1 in HHUS, but were graded as BIRADS 4 in ABUS; biopsy revealed a radial scar. Three carcinomas were graded as BI-RADS 2 in mammography but BI-RADS 4 in ABUS; two additional carcinomas were graded as BI-RADS 2 in mammography but BI-RADS 5 in ABUS. Two carcinomas, appearing as a well-circumscribed mass or developing asymmetry in mammography, were graded as BI-RADS 4 in mammography but BI-RADS 5 in ABUS.

Conclusions

ABUS could be successfully used in the visualisation and characterisation of breast lesions. ABUS seemed to outperform HHUS in the detection of architectural distortion on the coronal plane and can supplement mammography in the detection of non-calcified carcinomas in women with dense breasts.

Key Points

? The new generation of ABUS yields comparable results to HHUS. ? ABUS seems superior to HHUS in detecting architectural distortions. ? In dense breasts, supplemental ABUS to mammography detects additional cancers.
  相似文献   

8.

Objective

We wanted to determine the clinical feasibility of using non-breath-hold real-time MR-echo imaging for the evaluation of mediastinal and chest wall tumor invasion.

Materials and Methods

MR-echo imaging was prospectively applied to 45 structures in 22 patients who had non-small cell lung cancer when the tumor invasion was indeterminate on CT. The static MR imaging alone, and the static MR imaging combined with MR-echo examinations were analyzed. The surgical and pathological findings were compared with using the Wilcoxon-signed rank test and McNemar''s test.

Results

The accuracy, sensitivity and specificity of the combined MR-echo examination and static MR imaging for determining the presence of invasion were 84%, 83% and 85%, respectively, for the first reading session and they were 87%, 83% and 87%, respectively, for the second reading session (there was substantial interobserver agreement, k = 0.74). For the static MR imaging alone, these values were 62%, 83% and 59%, respectively, for the first reader and they were 69%, 67% and 74%, respectively, for the second reader (there was moderate interobserver agreement, k = 0.49). The diagnostic confidence for tumor invasion was also higher for the combined MR-echo examination and static MR imaging than that for the static MR imaging alone (p < 0.05).

Conclusion

The combined reading of a non-breath-hold real-time MR-echo examination and static MR imaging provides higher specificity and diagnostic confidence than those for the static MR imaging reading alone to determine the presence of mediastinal or chest wall tumor invasion when this was indeterminate on CT scanning.  相似文献   

9.

Objective

The goal of the study was to compare conventional mammography (MG) and contrast-enhanced spectral mammography (CESM) in preoperative women.

Materials and Methods

The study was approved by the local Ethics Committee and all participants provided informed consent. The study included 152 consecutive patients with 173 breast lesions diagnosed on MG or CESM. All MG examinations and consults were conducted in one oncology centre. Non-ionic contrast agent, at a total dose of 1.5 mL/kg body weight, was injected intravenous. Subsequently, CESM exams were performed with a mammography device, allowing dual-energy acquisitions. The entire procedure was done within the oncology centre. Images from low and high energy exposures were processed together and the combination provided an "iodine" image which outlined contrast up-take in the breast.

Results

MG detected 157 lesions in 150 patients, including 92 infiltrating cancers, 12 non-infiltrating cancers, and 53 benign lesions. CESM detected 149 lesions in 128 patients, including 101 infiltrating cancers, 13 non-infiltrating cancers, and 35 benign lesions. CESM sensitivity was 100% (vs. 91% for MG), specificity was 41% (vs. 15% for MG), area under the receiver operating characteristic curve was 0.86 (vs. 0.67 for MG), and accuracy was 80% (vs. 65% for MG) for the diagnosis of breast cancer. Both MG and CESM overestimated lesion sizes compared to histopathology (p < 0.001).

Conclusion

CESM may provide higher sensitivity for breast cancer detection and greater diagnostic accuracy than conventional mammography.  相似文献   

10.

Objectives

The aim of this study was to evaluate the diagnostic accuracy of fused fluoro-deoxy-D-glucose positron emission tomography/magnetic resonance mammography (FDG-PET/MRM) in breast cancer patients and to compare FDG-PET/MRM with MRM.

Methods

27 breast cancer patients (mean age 58.9±9.9 years) underwent MRM and prone FDG-PET. Images were fused software-based to FDG-PET/MRM images. Histopathology served as the reference standard to define the following parameters for both MRM and FDG-PET/MRM: sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for the detection of breast cancer lesions. Furthermore, the number of patients with correctly determined lesion focality was assessed. Differences between both modalities were assessed by McNemaŕs test (p<0.05). The number of patients in whom FDG-PET/MRM would have changed the surgical approach was determined.

Results

58 breast lesions were evaluated. The sensitivity, specificity, PPV, NPV and accuracy were 93%, 60%, 87%, 75% and 85% for MRM, respectively. For FDG-PET/MRM they were 88%, 73%, 90%, 69% and 92%, respectively. FDG-PET/MRM was as accurate for lesion detection (p = 1) and determination of the lesions'' focality (p = 0.7722) as MRM. In only 1 patient FDG-PET/MRM would have changed the surgical treatment.

Conclusion

FDG-PET/MRM is as accurate as MRM for the evaluation of local breast cancer. FDG-PET/MRM defines the tumours'' focality as accurately as MRM and may have an impact on the surgical treatment in only a small portion of patients. Based on these results, FDG-PET/MRM cannot be recommended as an adjunct or alternative to MRM.  相似文献   

11.

Objective

We wanted to evaluate the role of the arterial phase (AP) together with the portal venous phase (PP) scans in the diagnosis of Fitz-Hugh-Curtis syndrome (FHCS) with using computed tomography (CT).

Materials and Methods

Twenty-five patients with FHCS and 25 women presenting with non-specifically diagnosed acute abdominal pain and who underwent biphasic CT examinations were evaluated. The AP scan included the upper abdomen, and the PP scan included the whole abdomen. Two radiologists blindly and retrospectively reviewed the PP scans first and then they reviewed the AP plus PP scans. The diagnostic accuracy of FHCS on each image set was compared for each reader by analyzing the area under the receiver operating characteristic curve (Az). Weighted kappa (wk) statistics were used to measure the interobserver agreement for the presence of CT signs of the pelvic inflammatory disease (PID) on the PP images and FHCS as the diagnosis based on the increased perihepatic enhancement on both sets of images.

Results

The individual diagnostic accuracy of FHCS was higher on the biphasic images (Az = 0.905 and 0.942 for reader 1 and 2, respectively) than on the PP images alone (Az = 0.806 and 0.706, respectively). The interobserver agreement for the presence of PID on the PP images was moderate (wk = 0.530). The interobserver agreement for FHCS as the diagnosis was moderate on only the PP images (wk = 0.413), but it was substantial on the biphasic images (wk = 0.719).

Conclusion

Inclusion of the AP scan is helpful to depict the increased perihepatic enhancement, and it improves the diagnostic accuracy of FHCS on CT.  相似文献   

12.

Objective:

Biopsy has long been the standard approach in Breast Imaging Reporting and Data System® (BI-RADS) 4 or BI-RADS 5 (American College of Radiology, Reston, VA) lesions despite a wide variation in reported incidence of malignancy in BI-RADS 4 lesions. This study examined the diagnostic value of breast MRI as well as its ability to decrease unnecessary biopsies in patients with solid breast lesions who had an indication for biopsy.

Methods:

In this retrospective study, 277 breast lesions with a documented histological diagnosis as established by ultrasound-guided biopsy were included. All patients were female, and biopsy was performed owing to a BI-RADS score of 4 or 5 on ultrasonography. In addition, all patients had undergone MRI before biopsy. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of MRI in predicting malignancy were calculated.

Results:

When all lesions were analysed, sensitivity, specificity, NPV and PPV of MRI in detecting malignancy were 94.2%, 56.1%, 90.7% and 68.1%, respectively. When only ultrasonographic BI-RADS 4 lesions are considered, the corresponding figures were as follows: 90.9%, 56.7%, 93.8% and 46.4%, respectively. False-negative rate of MRI for the latter group of lesions was 2.6%. 42% of unnecessary biopsies were avoided in sonographic BI-RADS 4 lesions.

Conclusion:

Despite promising results obtained in this study, dynamic MRI currently does not seem to be effective in ruling out the need for biopsy in the assessment of sonographic BI-RADS 4 lesions. However, advanced MRI techniques may assist in improving possible benefits of MRI in this patient group.According to data from the American Cancer Society, Atlanta, GA, benign lesions account for nearly 80% of all breast biopsies performed. Although mammography is effective in detecting occult breast cancer, it is also associated with false-positive findings, resulting in the detection of different types of benign tissue in approximately 71–75% of the cases undergoing biopsy owing to suspicious mammography.1 This usually prompts the clinicians to use ultrasound or MRI to obtain additional information on the character of the lesions. However, this approach has resulted in higher cancer detection yields in females who are at increased risk of breast cancer at the expense of increased false-positivity rates.2,3Although it may be appropriate to monitor Breast Imaging Reporting and Data System® (BI-RADS) 3 (American College of Radiology, Reston, VA) (probably benign) lesions radiologically owing to their low cancer risk (0.3–1.7%),48 biopsy has long been the standard approach in BI-RADS 4 or BI-RADS 5 lesions. The reported risk of malignancy for BI-RADS 5 lesions is >95%, while a wide variation in reported incidence of malignancy is noted in BI-RADS 4 lesions (from 2% to 95%). Biopsy is recommended for any lesion with an estimated risk of malignancy exceeding 2% based on imaging findings. Therefore, most of the solid lesions visualized through imaging modalities are candidates for biopsy. In recent years, a good deal of research has been devoted to the combined use of different imaging modalities in order to decrease false-positive biopsies and to improve the well-known low specificity of radiological imaging techniques in general and ultrasound in particular. In this regard, breast MRI has been shown to provide a high negative predictive value (NPV) that may help safely exclude a diagnosis of malignancy.912In this study, the diagnostic value of breast MRI as well as its ability to decrease unnecessary biopsies has been examined in a group of patients with solid breast lesions who had an indication for biopsy based on ultrasound results.  相似文献   

13.

Objectives

To compare interobserver variability (IOV), reader confidence, and sensitivity/specificity in detecting architectural distortion (AD) on digital mammography (DM) versus digital breast tomosynthesis (DBT).

Methods

This IRB-approved, HIPAA-compliant reader study used a counterbalanced experimental design. We searched radiology reports for AD on screening mammograms from 5 March 2012–27 November 2013. Cases were consensus-reviewed. Controls were selected from demographically matched non-AD examinations. Two radiologists and two fellows blinded to outcomes independently reviewed images from two patient groups in two sessions. Readers recorded presence/absence of AD and confidence level. Agreement and differences in confidence and sensitivity/specificity between DBT versus DM and attendings versus fellows were examined using weighted Kappa and generalised mixed modeling, respectively.

Results

There were 59 AD patients and 59 controls for 1,888 observations (59?×?2 (cases and controls)?×?2 breasts?×?2 imaging techniques?×?4 readers). For all readers, agreement improved with DBT versus DM (0.61 vs. 0.37). Confidence was higher with DBT, p?=?.001. DBT achieved higher sensitivity (.59 vs. .32), p?<?.001; specificity remained high (>.90). DBT achieved higher positive likelihood ratio values, smaller negative likelihood ratio values, and larger ROC values.

Conclusions

DBT decreases IOV, increases confidence, and improves sensitivity while maintaining high specificity in detecting AD.

Key points

? Digital breast tomosynthesis decreases interobserver variability in the detection of architectural distortion.? Digital breast tomosynthesis increases reader confidence in the detection of architectural distortion.? Digital breast tomosynthesis improves sensitivity in the detection of architectural distortion.
  相似文献   

14.

Purpose

To evaluate the feasibility of assessing advanced T-stage (T3–T4) colorectal carcinomas by correlating MRI with histopathological findings.

Materials and methods

The study population comprised 31 patients with 32 lesions (22 colon and 10 rectal carcinomas). The relationship between the tumor and bowel layers on T2- and contrast-enhanced T1-weighted images (T2WI, CE-T1WI), bowel wall deformity, and the linear architecture of subserosal fat on T2WI scans was independently assessed by two radiologists. Diagnostic ability and interobserver agreement were evaluated using Fisher’s exact test and kappa statistics, respectively.

Results

The sensitivity/specificity for disrupting the outer layer on T2WI scans for the differentiation between Tis–T2 and T3–T4 colorectal carcinoma was 100/75 % (p < 0.05) for both observers; on CE-T1WI, it was 88.0/50 % (p = 0.13) for one and 96.0/50 % (p = 0.11) for the other. The sensitivity/specificity for recognizing the reticulated linear architecture to distinguish T3 from T4 colon carcinoma was 83.3/84.6 % (p < 0.05) for one reader and 100/92.3 % (p < 0.05) for the other reader.

Conclusion

Disruption of the outer low-intensity layer on T2WI scans was the most important finding for the diagnosis of T3–T4 colorectal carcinoma. The reticulated linear architecture of the fat tissue was suggestive of T4 colon carcinoma.
  相似文献   

15.

Objective

To evaluate the sonographic features of invasive apocrine carcinoma (IAC) of the breast.

Materials and Methods

This study included five pathologically proven cases of IAC, and their sonographic features were retrospectively analyzed according to the Breast Imaging Reporting and Data System (BI-RADS) lexicon.

Results

All five lesions involved the left breast and were seen as irregularly shaped masses. All lesions, except one, had a parallel orientation to the chest wall. All five lesions showed noncircumscribed margins and heterogeneous echotexture; however, they showed various posterior features. One lesion had edema as an associated feature. Sonographic assessments were classified as BI-RADS category 4 in all five cases.

Conclusion

Invasive apocrine carcinoma sonographic findings are difficult to differentiate from those of invasive ductal carcinoma of no special type.  相似文献   

16.

Objective:

To prospectively analyse the diagnostic value of semi-quantitative breast-specific gamma imaging (BSGI) in the work-up of suspicious breast lesions compared with that of mammography (MG), breast ultrasound and MRI of the breast.

Methods:

Within a 15-month period, 67 patients with 92 breast lesions rated as Category IV or V according to the breast imaging reporting and data system detected with MG and/or ultrasound were included into the study. After the injection of 740–1110 MBq of Technetium-99m (99mTc) SestaMIBI intravenously, scintigrams were obtained in two projections comparable to MG. The BSGI was analysed visually and semi-quantitatively by calculating a relative uptake factor (X). With the exception of two patients with cardiac pacemakers, all patients underwent 3-T breast MRI. Biopsy results were obtained as the reference standard in all patients. Sensitivity, specificity, positive- and negative-predictive values, accuracy and area under the curve were calculated for each modality.

Results:

Among the 92 lesions, 67 (72.8%) were malignant. 60 of the 67 cancers of any size were detected by BSGI with an overall sensitivity of 90%, only exceeded by ultrasound with a sensitivity of 99%. The sensitivity of BSGI for lesions <1 cm declined significantly to 60%. Overall specificity of ultrasound was only 20%. Specificity, accuracy and positive-predictive value were the highest for BSGI (56%, 80% and 85%, respectively). X was significantly higher for malignant lesions (mean, 4.27) and differed significantly between ductal types (mean, 4.53) and the other histopathological entities (mean, 3.12).

Conclusion:

Semi-quantitative BSGI with calculation of the relative uptake factor (X) can help to characterize breast lesions. BSGI negativity may obviate the need for biopsy of breast lesions >1 cm with low or intermediate prevalence for malignancy.

Advances in knowledge:

Compared with morphological imaging modalities, specificity, positive-predictive value for malignancy and accuracy were the highest for BSGI in our study. BSGI negativity may support the decision not to biopsy in selected lesions with a low or low-to-moderate pre-test probability for malignancy.Tissue characterization is fundamental in the assessment of suspicious breast lesions. Based on specific imaging findings, breast lesions are selected for biopsy, as histopathological examination is the essential part of a comprehensive diagnosis and the basis for an individually adjusted therapy.An imaging modality used in this setting should be rapidly available and highly accurate, minimizing the need for additional examinations and preventing unnecessary biopsies of benign lesions. Being aware of the limitations of the established imaging modalities, such as mammography (MG), ultrasound and MRI of the breast, we implemented breast-specific gamma imaging (BSGI) as an adjunct imaging modality in the work-up of suspicious breast lesions.1 BSGI as functional imaging modality visualizes metabolic alterations in contrast to MG, ultrasound and MRI, which show primarily structural breast changes as morphological imaging modalities.The BSGI has been suggested to overcome some limitations of scintimammography as described in the latest version of the European Association of Nuclear Medicine (EANM) breast scintigraphy guidelines.2 In scintimammography, it was impossible to create images comparable to MG because standard gamma cameras were used.3 In contrast to BSGI, prone positioning required for scintimammography prevented direct contact of the breast and the detector and compromised the spatial resolution.4 Edge effects at the border of the large single crystal of sodium iodine (NaI) resulted in a significant “dead space”.5In contrast to former studies, such as Tadwalkar et al,6 we implemented BSGI in the assessment of suspicious breast lesions detected initially with MG and breast ultrasound. As a result, we were able to prospectively analyse the performance of BSGI in the assessment of suspicious breast lesions and to compare the results to the other well-established imaging modalities in a large series of patients in a breast cancer centre. The benefit of an easily calculated uptake factor (X) in addition to visual evaluation was also assessed.  相似文献   

17.

Objective

The aim of the study was to compare the diagnostic performances of F-18 sodium fluoride positron emission tomography/computed tomography (bone PET/CT) and bone scintigraphy (BS) for the detection of thyroid cancer bone metastasis.

Materials and Methods

We retrospectively enrolled 6 thyroid cancer patients (age = 44.7 ± 9.8 years, M:F = 1:5, papillary:follicular = 2:4) with suspected bone metastatic lesions in the whole body iodine scintigraphy or BS, who subsequently underwent bone PET/CT. Pathologic diagnosis was conducted for 4 lesions of 4 patients.

Results

Of the 17 suspected bone lesions, 10 were metastatic and 7 benign. Compared to BS, bone PET/CT exhibited superior sensitivity (10/10 = 100% vs. 2/10 = 20%, p = 0.008), and accuracy (14/17 = 82.4% vs. 7/17 = 41.2%, p < 0.025). The specificity (4/7 = 57.1%) of bone PET/CT was not significantly different from that of BS (5/7 = 71.4%, p > 0.05).

Conclusion

Bone PET/CT may be more sensitive and accurate than BS for the detection of thyroid cancer bone metastasis.  相似文献   

18.

Objective

To compare the use of conventional, real-time compound, and pulse-inversion harmonic imaging in the evaluation of breast nodules.

Materials and Methods

Fifty-two breast nodules were included in this study, conducted between May and December 2000, in which conventional, real-time compound, and pulse-inversion harmonic images were obtained in the same plane. Three radiologists, each blinded to the interpretations of the other two, evaluated the findings, characterizing the lesions and ranking the three techniques from grade 1, the worst, to grade 3, the best. Lesion conspicuity was assessed, and lesions were also characterized in terms of their margin, clarity of internal echotexture, and clarity of posterior echo pattern. The three techniques were compared using Friedman''s test, and interobserver agreement in image interpretation was assessed by means of the intraclass correlation coefficient.

Results

With regard to lesion conspicuity, margin, and internal echotexture of the nodules, real-time compound imaging was the best technique (p < 0.05); in terms of posterior echo pattern, the best was pulse-inversion harmonic imaging (p < 0.05). Real-time compound and pulse inversion harmonic imaging were better than conventional sonography in all evaluative aspects. Interobserver agreement was greater than moderate.

Conclusion

Real-time compound and pulse-inversion harmonic imaging procedures are superior to conventional sonography in terms of both lesion conspicuity and the further characterization of breast nodules. Real-time compound imaging is the best technique for evaluation of the margin and internal echotexture of nodules, while pulse-inversion harmonic imaging is very effective for the evaluation of the posterior echo patterns.  相似文献   

19.
20.

Objectives:

The aim of this CBCT investigation on the detection of caries was to assess the influence of artefacts produced by the presence of amalgam fillings located in the vicinity.

Methods:

102 non-cavitated pre-molar and molar teeth were placed in blocks of silicone with approximal contacts consisting of 3 sound or carious teeth and 1 mesial–occlusal–distal amalgam-filled tooth in-between. Radiographs of all the teeth were recorded using the CBCT system (NewTom™ 3G; QR Srl, Verona, Italy; field of view, 9 inches). Data from the CBCT unit were reconstructed and sectioned in the mesiodistal tooth plane. Images were evaluated twice by two observers, using a five-step confidence scale. After the CBCT examination, the teeth were individually sectioned in the mesiodistal direction with a diamond saw. Using a light microscope at ×40 magnification, the true morphological status of all approximal surfaces was established.

Results:

Sensitivity of the CBCT for the detection of caries on surfaces located proximally and distally to an amalgam filing ranged from 0.27 to 0.30 for enamel and from 0.47 to 0.56 for dentin. Specificity values for enamel proximal and distal lesions were 0.48 and 0.53, respectively, for enamel and 0.33 to 0.38, respectively, for proximal and distal dentin cases. Intra-observer reliability was 0.84, and interobserver reliability was 0.49.

Conclusions:

Owing to its low specificity, scans from a CBCT examination should not be used to determine the presence of demineralization of the tooth surface when amalgam fillings are present in the region of interest.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号