首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
RATIONALE AND OBJECTIVES: To evaluate the diagnostic utility of indirect MR arthrography of the unexercised glenohumeral joint in patients with rotator cuff tears confirmed by arthroscopy or arthrotomy as the gold standard. METHODS: Twenty-six patients underwent conventional MR imaging and indirect MR arthrography of the stationary glenohumeral joint using a wrap-around surface coil. Unenhanced T1-weighted spin echo/T2-weighted fast spin echo sequences and T1-weighted gradient echo sequences, adding spectral fat suppression after intravenous administration of contrast medium, were performed in the oblique coronal and oblique sagittal planes. Images were analyzed by three experienced radiologists in consensus. Levels of diagnostic confidence were evaluated using a four-point scale of diagnostic certainty. RESULTS: Performing indirect MR arthrography of the unexercised shoulder leads to a diagnostically efficient enhancement of joint fluid (120% at 4 minutes and 145% at 8 minutes after intravenous injection of gadodiamide). In terms of soft tissue delineation, characterization of rotator cuff tears was significantly improved by using enhanced fat-suppressed T1-weighted gradient echo sequences compared with conventional MR imaging. CONCLUSIONS: Indirect MR arthrography without glenohumeral joint exercise in the diagnosis of rotator cuff tears is feasible and represents a more convenient and less time-consuming alternative to indirect MR arthrography after joint exercise.  相似文献   

2.
The purpose of this study was to compare the diagnostic performance of fat-saturation fast-spin-echo (FSE) T2-weighted (T2W) sequences with conventional spin-echo (CSE) T2W sequences in the detection of rotator cuff pathology using surgery as the reference standard. Oblique coronal dual-echo CSE and FSE T2W images with fat saturation from 50 surgically confirmed MR shoulder examinations were acquired on a 1.5-T MR scanner. Blinded MR readers retrospectively analyzed each imaging sequence separately and ultimately correlated both sequences together with findings at surgery. FSE was 100% sensitive and 94% specific in detection of full-thickness tears (n = 19) and 73% sensitive and 97% specific in the detection of partial-thickness rotator cuff tears (n = 13). There was no statistically significant difference in the performance of FSE with fat saturation compared with CSE. The two discrepancies between imaging sequences related to the extent of partial-thickness tears. Our findings suggest that fat-saturation FSE imaging can effectively replace CSE imaging in the evaluation of rotator cuff pathology.  相似文献   

3.
Most magnetic resonance (MR) studies evaluating the rotator cuff for tears have used T2-weighted imaging in the coronal oblique and sagittal oblique planes, T2*-weighted gradient echo imaging, however, has advantages over spin echo imaging, including contiguous slices without cross-talk, high contrast around the cuff, and intrinsically shorter imaging times which can be used to increase the number of signals averaged and thus improve the signal-to-noise ratio. We reviewed the shoulder MR scans of 87 consecutive patients who underwent both a MR scan and a shoulder arthroscopy during which the size of tears, if present, was graded. The reviewers were blinded as to the history and arthroscopic results. The MR scans included oblique coronal T2*-weighted gradient echo and oblique sagittal T2-weighted spin echo images. MR cuff grades were correlated with arthroscopic findings. For complete tears, the sensitivity of MR was 0.91 and the specificity 0.95. For partial tears, the sensitivity was 0.74 and the specificity 0.87. This accuracy is similar to two-plane T2-weighted imaging as previously reported in the literature. There was a statistically significant correlation (p < 0.0005) between the cuff grade as determined by MR and the arthroscopic findings.  相似文献   

4.
目的 评价梯度回波T2*WI对肩袖病变的诊断价值。资料与方法 对35例可疑肩袖损伤的病例进行前瞻性MRI检查,对比分析斜冠状位T2*WI和脂肪抑制快速自旋回波T2WI(FS TSET2WI)对肩袖病变的诊断价值。结果 T2*WI和FS TSE T2WI对肩袖损伤的评价具有较好的诊断一致性,Kappa值为0.746。不管是对总的肩袖撕裂,还是对于肩袖全层撕裂,T2*WI的诊断敏感性和阴性预测值均高于FS TSE T2WI,但其诊断特异性和阳性预测值降低。结论 T2*WI和FS TSE T2WI对于肩袖损伤的评价具有较好的诊断一致性。  相似文献   

5.
RATIONALE AND OBJECTIVES: Spin lock imaging has been shown to be useful in characterizing head and neck tumors. The purposes of this study were to explore and develop multiple-slice spin lock gradient-echo (SL-GRE) sequences for head and neck imaging and to compare the tumor contrast on SL images to spin-echo (SE) T2-weighted images at 0.1 T. METHODS: On the basis of measured relaxation times of tumors and head and neck tissues, the authors evaluated with signal equations the effect of imaging parameters on tissue contrast produced by the SL-GRE sequence. In the clinical study, 34 patients with pathologically verified head and neck tumors were imaged with multiple-slice SL-GRE (repetition time 1500 ms/echo time 30 ms) out-of-phase fat/water sequences and compared with T2-weighted SE (repetition time 1500 ms/echo time 120 ms) sequences. The conspicuity of tumors was evaluated by calculating the contrast-to-noise ratios (CNRs). RESULTS: The combination of a short echo time of 30 ms and the length of locking pulses in the range of 10 to 35 ms produced optimal CNRs for head and neck tumor imaging. The measured CNRs and subjective evaluation for tumor detection were satisfactory with both imaging sequences. However, the CNRs between tumors and salivary gland tissues were significantly greater with the SL sequence than with the T2-weighted sequence. CONCLUSIONS: The multiple-slice SL-GRE technique provides image contrast comparable to that of SE T2-weighted imaging for head and neck tumors at 0.1 T. With short locking pulse lengths and echo times, wide anatomic coverage and reduced motion and susceptibility artifacts can be achieved. The out-of-phase SL technique is useful in imaging salivary gland tumors.  相似文献   

6.
MR arthrography of the shoulder: comparison with conventional MR imaging   总被引:5,自引:0,他引:5  
Twenty-three patients underwent both conventional MR imaging of the shoulder and MR shoulder arthrography for clinically suspected labral or rotator cuff abnormalities. Images obtained before and after contrast administration were studied independently, and without knowledge of clinical findings, by two radiologists for the presence of abnormalities of the glenoid labrum or rotator cuff. Results were correlated with surgical findings in all patients. Nine patients had surgically proved labral tears. MR arthrography detected all nine labral abnormalities, while six of the nine were missed on conventional MR imaging. Fourteen patients had surgically proved rotator cuff tears. MR arthrography detected 11 of the 14 tears and missed three partial tears on the bursal surface. Conventional MR imaging detected nine cuff tears and missed five tears; two of these were complete rotator cuff tears and three were partial tears of the undersurface of the rotator cuff. Our results suggest that MR arthrography enhances the accuracy of MR in the evaluation of the glenoid labrum and rotator cuff tendon.  相似文献   

7.
Conventional magnetic resonance imaging (MRI) of the rotator cuff has not done well in distinguishing partial-thickness tears from tendonitis or small, full-thickness tears. However, these are important distinctions for orthopedic surgeons who are deciding whether to operate and what type of surgery to perform on a patient with suspect rotator cuff pathology. Gadolinium magnetic resonance arthrography (MRA) involves injecting dilute gadolinium into the shoulder under fluoroscopy. Subsequent multiplanar T1-weighted fat-suppressed fast spin echo combined with T2-weighted fast spin echo and short tau inversion recovery (STIR) produces images that can accurately differentiate absence of tear from partial-thickness tear and from small, full-thickness tear; as a fringe benefit, this combination of sequences can identify the inflammation associated with tendonitis. Furthermore, the technique differentiates articular from bursal surface partial-thickness tears, and it accurately quantitates the size of full-thickness tears to help surgeons choose between arthroscopic versus open surgery.  相似文献   

8.
The value of T2-weighted fast spin-echo imaging of the musculoskeletal system was assessed in 22 patients with various neoplastic, inflammatory, and traumatic disorders. Images were acquired with high echo number (i.e., echo train length) fast spin-echo (FSE; TR 2000 ms, effective TE 100 ms, echo number 13, lineark-space ordering), conventional spin-echo (SE; TR 2000 ms, TE 100 ms) and gradient-echo (GRE) sequences (TR 600 ms, TE 34 ms, flip angle 25°). Signal intensities, signal-to-noise ratios, contrast, contrast-to-noise ratios, lesion conspicuousness, detail perceptibility, and sensitivity towards image artifacts were compared. The high signal intensity of fat on FSE images resulted in a slightly inferior lesion-to-fat contrast on FSE images. However, on the basis of lesion conspicuity, FSE is able to replace time-consuming conventional T2-weighted SE imaging in musculoskeletal MRI. In contrast, GRE images frequently showed superior lesion conspicuity. One minor disadvantage of FSE in our study was the frequent deterioration of image quality by blurring, black band, and rippling artifacts. Some of these artifacts, however, can be prevented using short echo trains and/or short echo spacings.  相似文献   

9.
PURPOSE: To conduct a multi-center assessment of the use of a 0.2-T, extremity MR system (E-scan; General Electric Lunar Corp. and Esaote, Genoa, Italy) for identifying tears of the rotator cuff and glenoid labrum. MATERIALS AND METHODS: A retrospective study was performed involving 160 patients (age range, 15-84 years old) from five facilities in the United States, comparing shoulder MR imaging to surgical findings. MR imaging of the shoulder was conducted as follows: shoulder coil; T1-weighted spin echo, coronal-oblique and axial images; short Tau inversion recovery (STIR), coronal-oblique images and axial images; and T2-weighted spin echo, coronal-oblique and sagittal-oblique images. The MR examinations were interpreted in an independent, prospective manner by two radiologists with extensive musculoskeletal MRI experience. Arthroscopic (N = 103) or open surgical (N = 57) procedures were performed within a mean of 53 days after MR imaging. RESULTS: Surgical findings demonstrated rotator cuff tears in 131 patients and labral tears in 60 patients. For the rotator cuff, the sensitivity, specificity, positive predictive value, and negative predictive value were 90%, 93%, 98%, and 68%, respectively. For the labrum, the sensitivity, specificity, positive predictive value, and negative predictive value were 55%, 100%, 100%, and 82%, respectively. CONCLUSIONS: There was good agreement when MR results obtained using the extremity MR system were compared to surgical findings for identifying rotator cuff tears, while the sensitivity of MR imaging for determining labral tears was relatively poor. Nevertheless, these findings were comparable to those reported in the peer-reviewed literature for MR systems operating at mid-, and high-field-strengths.  相似文献   

10.
Rotator cuff tears: diagnostic performance of MR imaging   总被引:10,自引:0,他引:10  
To determine the diagnostic performance of magnetic resonance (MR) imaging in the evaluation of suspected rotator cuff tears, eight asymptomatic volunteers and 32 patients with rotator cuff tendonopathy who underwent surgery were examined with MR imaging. Twenty-four of these patients also underwent contrast arthrography. The ability of MR imaging to depict the size of cuff tears and the quality of torn tendon edges was also evaluated. The MR imaging and arthrographic studies were reviewed without knowledge of surgical results or of the other studies. A scoring system was developed and a score assigned to each patient's MR study. The sensitivity of MR imaging for all tears (partial and full thickness) was 0.91, and the specificity was 0.88; whereas the sensitivity and specificity of arthrography were each 0.71. The scoring system improved the sensitivity to 1.0 and the specificity to 0.92. Linear regression analysis showed excellent correlation between preoperative assessment of the size of rotator cuff tears and measurement at surgery (r = .95).  相似文献   

11.
Rationale and Objectives.Recent evidence suggests an inhomogeneous distribution of intramuscular rotator cuff fat infiltration (FI) in a small sample of individuals with rotator cuff tears, yet clinically just a few slices at the scapular Y-view are used to evaluate FI in patients with rotator cuff tears. The purpose of this study was to determine if assessment of FI using the scapular Y-view is representative of the entire muscle in patients with full-thickness rotator cuff tears, and whether this varies by tear size.Materials and methodsPatients (N = 25) diagnosed with full-thickness rotator cuff tear and confirmed with magnetic resonance imaging (MRI) were included. Fat-water sequences were used to objectively quantify mean FI (%) in the entire 3D muscle and the mean from 3 slices at the Y-view. Mixed-model 2 × 2 ANOVAs were used to assess for differences between methods, and if results vary by tear-size.ResultsThere were no statistically significant differences between mean amount of FI of the entire 3D muscle and mean Y-view in the supraspinatus or infraspinatus muscles (p > 0.05). Additionally, this did not differ across tear size groups (p > 0.05).ConclusionResults of this study suggest FI assessed in the Y-view is not different (mean difference < 1.0%) from FI of the entire 3D muscle in patients with full-thickness rotator cuff tears. Therefore, the clinical utility of evaluating rotator cuff intramuscular fat infiltration with the Y-view is further supported in patients with full-thickness rotator cuff tears across tear sizes.  相似文献   

12.
PURPOSE: To assess the magnetic resonance (MR) imaging appearance of the successfully repaired rotator cuff in an asymptomatic population. MATERIALS AND METHODS: Fifteen subjects who had undergone clinically successful rotator cuff repair were included in the study. All underwent functional testing of the affected shoulder and had good to excellent scores on the Constant scale. Standard MR imaging sequences were performed at 1.5 T, including oblique coronal fast spin-echo T2-weighted MR imaging with fat saturation. RESULTS: Three (10%) of 30 supraspinatus and infraspinatus tendons had normal signal intensity, and 16 (53%) had mildly increased signal intensity on fast spin-echo T2-weighted fat-saturated images, compatible with tendonitis or tendinosis. Three partial and four complete tears of the supraspinatus tendon and two partial and two complete tears of the infraspinatus tendon were seen. Other findings included subacromial-subdeltoid effusion (10 subjects), joint effusions (five subjects), and bone marrow edema (six subjects). CONCLUSION: Postoperative signal intensity changes consistent with tendonitis or tendinosis were common, and clinically "silent" partial and complete rotator cuff tears were seen. Such postoperative MR imaging findings should be interpreted with caution, and meticulous correlation with symptoms and clinical results is recommended.  相似文献   

13.
Objective. Fast spin-echo (FSE) sequences reduce imaging time compared with conventional spin-echo (CSE) sequences, but may result in blurring. High-performance gradients permit shorter interecho spacing and use of the second echo as the effective TE (20 ms); both improvements reduce blurring. This randomized observer study compared a short TE, second-echo FSE sequence obtained using high-performance gradients and a CSE sequence with similar TR/TE for the detection of meniscal tears in the knee. Design and patients. One hundred consecutive MR examinations of the knee using FSE and CSE sequences at 1.5 T were evaluated. The FSE sequence used an effective TE of 20 ms (centered on the second echo at 2 times minimal interecho spacing) and an echo train length of 4. FSE and CSE parameters were otherwise similar. Four independent, masked readers reviewed randomized sagittal FSE and CSE sequences. Results. Cases were assessed for the presence or absence of meniscal tears and, if present, whether tears were medial or lateral and anterior or posterior. Sequence concordance was 93.5% (1496 of 1600 meniscal segments); the intermethod kappa value was 0.78. Sequence quality was graded from 1 to 5. Average quality of CSE images was slightly but statistically significantly preferred by three of the four readers. Conclusion. There was no statistically significant difference between CSE imaging and FSE imaging centered on the second echo (20 ms) using high-performance gradients for the detection of meniscal tears in the knee. There was a small preference for the quality of CSE images. Received: 22 July 1999 Revision requested: 27 October 1999 Revision received: 7 February 2000 Accepted: 21 March 2000  相似文献   

14.
Purpose  The purpose of this paper was to evaluate if short volumetric interpolated breath-hold examination (VIBE) sequences can be used as a substitute for T1-weighted with fat saturation (T1-FS) sequences when performing magnetic resonance (MR) arthrography to diagnose rotator cuff tears. Materials and methods  Eighty-two patients underwent direct MR arthrography of the shoulder joint using VIBE (acquisition time of 13 s) and T1-FS (acquisition time of 5 min) sequences in the axial and paracoronal plane on a 1.0-T MR unit. Two radiologists scored rotator cuff tendons on VIBE and T1-FS images separately as normal, small/large partial thickness and full thickness tears with or without geyser sign. T1-FS sequences were considered the gold standard. Surgical correlation was available in a small sample. Results  Sensitivity, specificity, and positive and negative predictive values of VIBE were greater than 92% for large articular-sided partial thickness and full thickness tears. For detecting fraying and articular-sided small partial thickness tears, these parameters were 55%, 94%, 94%, and 57%, respectively. The simple kappa value was 0.76, and the weighted kappa value was 0.86 for agreement between T1-FS and VIBE scores. All large partial and full thickness tears at surgery were correctly diagnosed using VIBE or T1-FS MR images. Conclusion  Fast MR arthrography of the shoulder joint using VIBE sequences showed good concordance with the classically used T1-FS sequences for the appearance of the rotator cuff, in particular for large articular-sided partial thickness tears and for full thickness tears. Due to its very short acquisition time, VIBE may be especially useful when performing MR arthrography in claustrophobic patients or patients with a painful shoulder.  相似文献   

15.
MR imaging diagnosis of rotator cuff tears   总被引:4,自引:0,他引:4  
Thirty-one symptomatic patients were studied with MR imaging to evaluate the sensitivity and specificity of shoulder MR in the diagnosis of rotator cuff tears. Correlative studies included arthroscopy in 19 patients and arthrography in 12 patients. Images were obtained on either a 0.5- or 1.5-T Philips superconducting magnet using spin-echo pulse sequences (650-850/30 [TR, TE], 2000/30, 100) with 5-mm slices oriented in an oblique coronal plane perpendicular to the glenohumeral joint. The MR studies were initially interpreted without knowledge of the results of other diagnostic procedures. The MR diagnosis of cuff tear was made when irregularity, discontinuity, and increased signal were identified in the rotator cuff. MR images showed tears in 10 patients (32%) and were negative for tear in 21 patients (68%). MR correlated with arthroscopy and arthrography in 17 of 18 normal patients, in eight of 10 patients with complete tears, and in one of three patients with partial tears. For complete rotator cuff tears, the sensitivity, specificity, and accuracy were 80%, 94%, and 89%, respectively. For all tears (partial and complete), the sensitivity, specificity, and accuracy were 69%, 94%, and 84%, respectively. These data suggest that MR imaging is an accurate procedure for the diagnosis of complete rotator cuff tears. The number of partial tears (three) in this series is too small to evaluate the value of MR imaging in the diagnosis of partial tears.  相似文献   

16.
Purpose To re-evaluate the relationship between os acromiale and rotator cuff tears. Methods We retrospectively analyzed 84 magnetic resonance imaging studies of the shoulder. Forty-two subjects with os acromiale (n = 42; 32 men and ten women, age 25–81 years, mean 47.6 years) were compared with age- and gender-matched subjects with no evidence of os acromiale (controls). Arthroscopy data were available in 19 os acromiale and 12 control subjects. Statistical analyses were performed to determine differences between groups regarding rotator cuff tears affecting the supraspinatus and infraspinatus tendons detected by magnetic resonance imaging and arthroscopy. Analysis of os acromiale type, ossicle synchondrosis edema, acromioclavicular joint degenerative changes and step-off deformity at the synchondrosis were tabulated. Results No statistically significant difference between the os acromiale and control groups was noted, either on magnetic resonance imaging or arthroscopy, with regard to tears of the supraspinatus (P = 1.000 and 0.981, respectively) and infraspinatus (P = 1.000 and 0.667, respectively) tendons. There was a statistically significant increased number of supraspinatus (P = 0.007) and infraspinatus (P = 0.03) tears in a comparison of subjects with os acromiale and step-off deformity (10/42) vs os acromiale without step-off deformity (32/42). Conclusion The presence of os acromiale may not significantly predispose to supraspinatus and infraspinatus tendon tears. However, subjects with step-off deformity of an os acromiale are at greater risk of rotator cuff tears than are similar subjects without such deformity.  相似文献   

17.

Objective:

To evaluate the diagnostic accuracy of three-dimensional (3D) enhanced T1 high-resolution isotropic volume excitation (eTHRIVE) shoulder MR for variable shoulder pathology such as rotator cuff tear, labral injury and synovial pathology in comparison with two-dimensional enhanced fast spin echo T1 fat saturation (2D T1 FS) sequences MR.

Methods:

This retrospective study included 86 patients who underwent MRI of the shoulder using eTHRIVE technique. Two radiologists evaluated anatomic identification of the supraspinatus, glenoid labrum and acromioclavicular joint (AC joint) on routine MRI sequences (2D T1 FS) and compared them with the reformatted eTHRIVE images. Subjective scoring of the images was performed with a four-point scale that rated the degree of discrimination of the shape of the supraspinatus, glenoid labrum and AC joint. The diagnostic accuracy of eTHRIVE compared with routine MR images was evaluated in terms of rotator cuff pathology, labral pathology and synovial pathology.

Results:

Anatomic identification scores of the supraspinatus tendon and labrum were significantly lower for eTHRIVE than for 2D T1 FS. There were no significant differences between eTHRIVE and 2D T1 FS in anatomic identification of the AC joint. There were no significant differences between eTHRIVE and 2D T1 FS in diagnosing the three disease categories.

Conclusion:

eTHRIVE had comparable diagnostic accuracy to 2D T1 FS imaging in the evaluation of rotator cuff tears, labral injury and synovial pathology, but anatomic identification was inferior to that of 2D T1 FS.

Advances in knowledge:

The accuracy of 3D eTHRIVE imaging is comparable to that of 2D T1 FS for the diagnosis of rotator cuff tears, labral injury and synovial pathology.  相似文献   

18.
In 28 patients the preoperative MR results and arthroscopic examination findings, in which both sides of the rotator cuff were systematically examined, were compared. The interpretive MR criteria were both sensitive and specific for detection of full thickness tears: 100% (5 of 5) and 100% (23 of 23), respectively. Criteria were insensitive in 71% (10 of 14) but specific in 93% (13 of 14) for detection of all tears; 4 of 9 partial thickness tears were not detected of MR. The potential significance of these tears and the use of fat suppression MR sequences to improve detection and depiction of rotator cuff abnormalities are discussed.  相似文献   

19.
Experience with rotator cuff sonography in 106 patients was analyzed to identify the causes of scan misinterpretation. Possible interpretive errors may be classified into four categories: those from failure to recognize normal anatomy, those caused by soft-tissue abnormalities, those caused by bony abnormalities, and those caused by technical limitations of the study. Errors in recognition of normal anatomy are easily overcome by experience and comparison to the normal, contralateral rotator cuff. Errors resulting from soft-tissue abnormalities were seen in two patients with calcific tendinitis simulating rotator cuff tears. Problems in interpretation resulting from fractures in two patients and inferior glenohumeral subluxation in two other patients could have been avoided by review of the plain films before performing sonography. The major technical limitation of the study arises from the inability to image the rotator cuff beneath the acromion. Fortunately, rotator cuff tears are rarely isolated in this location, and passive maneuvers often allow otherwise hidden parts of the cuff to be imaged.  相似文献   

20.
OBJECTIVE: Studies linking greater tuberosity findings on radiographs with rotator cuff disease have largely been uncontrolled and biased toward more severe disease. We correlated greater tuberosity changes seen on radiography with rotator cuff disease seen on MR images in a broadly symptomatic patient population. MATERIALS AND METHODS: Both radiography and MR imaging were performed in 108 shoulders. Unaware of the MR imaging findings, three radiologists independently reviewed the radiographs for cortical thickening, subcortical sclerosis, and cystlike lesions in the humeral greater tuberosity. Interobserver agreement was analyzed using kappa statistics. We correlated the radiographic findings with MR imaging evidence of rotator cuff tears and tendonopathy. The positive predictive value of each finding for rotator cuff disease was also calculated. RESULTS: Interobserver agreement for the three radiographic findings was poor to fair: Kappa values ranged from .06 to .41. Cortical thickening and subcortical sclerosis were not seen more frequently in shoulders with rotator cuff disease than in normal shoulders. Cystlike lesions were more prevalent in shoulders with rotator cuff disease, but the association reached statistical significance (p < .05) for one observer only. Positive predictive values for each finding were low (14-48% for predicting full-thickness rotator cuff tears). CONCLUSION: Cortical thickening of the greater tuberosity and subcortical sclerosis are not associated with rotator cuff disease. For some observers, identifying cystlike lesions is associated with rotator cuff disease, but the clinical usefulness of the observation is limited by high interobserver variability and poor positive predictive value.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号