首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A reverse phase high performance liquid chromatography method was developed for simultaneous estimation of nitazoxanide and ofloxacin in tablet formulation. The separation and quantification was achieved by Hiq Sil C18V Size 4.6 mm Ø *250 mm column in isocratic mode, with mobile phase consisting of acetonitrile-methanol-0.4 M citric acid, (60:30:10, v/v/v). Citric acid used to stabilize nitazoxanide and ofloxacin in mobile phase. The mobile phase was pumped at a rate of 0.6 ml/min and the detection was carried out at 304 nm. The retention time of ofloxacin and nitazoxanide was found to be 3.122 and 5.902 min, respectively. The method was validated for linearity, accuracy, and precision. Linearity for ofloxacin and nitazoxanide were in the range 2-36 μg/ml and 5-90 μg/ml, respectively. The developed method was found to be accurate, precise and selective for simultaneous estimation of ofloxacin and nitazoxanide in tablets.  相似文献   

2.
A simple, specific and accurate reverse phase liquid chromatographic method was developed for the simultaneous determination of losartan potassium and ramipril in table dosage forms. A hypersil ODS C18, 4.6×250 mm, 5 μm column in isocratic mode, with mobile phase acetonitrile:methanol:10 mM tetra butyl ammonium hydrogen sulphate in water in the ratio of 30:30:40% v/v/v was used. The flow rate was 1.0 ml/min and effluent was monitored at 210 nm. The retention times of losartan potassium and ramipril were 4.7 and 3.3 min, respectively. The linearity range for losartan potassium and ramipril were in the range of 0.04-100 μg/ml and 0.2-300 μg/ml, respectively. The proposed method was also validated and successfully applied to the estimation of losartan potassium and ramipril in combined tablet formulations.  相似文献   

3.
A rapid high performance liquid chromatographic method has been developed and validated for the estimation of ramipril and telmisartan simultaneously in combined dosage form. A Genesis C18 column having dimensions of 4.6×250 mm and particle size of 5 μm in isocratic mode, with mobile phase containing a mixture of 0.01 M potassium dihydrogen phosphate buffer (adjusted to pH 3.4 using orthophosphoric acid): methanol:acetonitrile (15:15:70 v/v/v) was used. The mobile phase was pumped at a flow rate of 1.0 ml/min and the eluents were monitored at 210 nm. The selected chromatographic conditions were found to effectively separate ramipril (Rt: 3.68 min) and telmisartan (Rt: 4.98 min) having a resolution of 3.84. The method was validated in terms of linearity, accuracy, precision, specificity, limit of detection and limit of quantitation. Linearity for ramipril and telmisartan were found in the range of 3.5-6.5 μg/ml and 28.0-52.0 μg/ml, respectively. The percentage recoveries for ramipril and telmisartan ranged from 99.09-101.64% and 99.45-100.99%, respectively. The limit of detection and the limit of quantitation for ramipril was found to be 0.5 μg/ml and 1.5 μg/ml respectively and for telmisartan was found to be 1.5 μg/ml and 3.0 μg/ml, respectively. The method was found to be robust and can be successfully used to determine the drug content of marketed formulations.  相似文献   

4.
A simple reverse phase liquid chromatographic method has been developed and subsequently validated for simultaneous determination of salbutamol sulphate and bromhexine hydrochloride. The separation was carried out using a mobile phase consisting of acetonitrile, methanol and phosphate buffer, pH 4 in the ratio 60:20:20 v/v. The column used was SS Wakosil-II C-18 with a flow rate of 1 ml/min and UV detection at 224 nm. The described method was linear over a concentration range of 10-110 μg/ml and 20-140 μg/ml for the assay of salbutamol sulphate and bromhexine hydrochloride, respectively. The mean recovery was found to be 95-105% for salbutamol sulphate and 96.2-102.1% for bromhexine hydrochloride when determined at five different levels.  相似文献   

5.
A rapid and sensitive reverse phase high performance liquid chromatographic method is depicted for the qualitative and quantitative assay of letrozole in pharmaceutical dosage forms. Letrozole was chromatographed on a reverse phase C18 column with a mobile phase consisting of acetonitrile and phosphate buffer (pH 7.8) in the ratio of 70:30 v/v. The mobile phase was pumped at a flow rate of 1 ml/min. Acenaphthene was used as an internal standard and the eluents were monitored at 232 nm. The retention time of the drug was 3.385 min. With this method, linearity was observed in the range of 10-100 μg/ml. The LOD and LOQ were found to be 0.51 μg/ml and 1.52 μg/ml, respectively. The method was found to be applicable for analysis of drug in tablets. The results of the analysis were validated statistically.  相似文献   

6.
A simple, precise, and sensitive capillary electrophoresis technique coupled with a diode array detector has been developed for the separation and simultaneous determination of ezetimibe and atorvastatin in pharmaceutical formulations. Separation of both ezetimibe and atorvastatin was achieved utilizing fused silica capillary (58 cm × 75 μm ID) and background electrolyte solution that consisted of phosphate buffer (2.5 mM, pH 6.7): methanol (70:30 v/v). The proposed method was validated by testing its specificity, linearity, precision, accuracy, recovery, and detection limit/quantitation limit values. The method was linear over the range 2.5–50 μg/ml for ezetimibe (r = 0.9992) and 1–100 μg/ml for atorvastatin (r = 0.9999). Within-day and between-day RSD for ezetimibe and atorvastatin were ⩽5.6% and ⩽2.9%, respectively. The detection limit was 0.07 μg/ml for ezetimibe and 0.06 μg/ml for atorvastatin. The validated method was successfully employed for the determination of ezetimibe and atorvastatin in tablets with no interfering peaks from common pharmaceutical excipients. The percentage recoveries of the two drugs from their tablets were 99.80 ± 1.76 and 100.19 ± 1.83, respectively.  相似文献   

7.
Reversed phase high performance liquid chromatographic method was developed and validated for the estimation of voriconazole in bulk and formulation using prominence diode array detector. Selected mobile phase was a combination of water:acetonitrile (35:65 % v/v) and wavelength selected was 256 nm. Retention time of voriconazole was 3.95 min. Linearity of the method was found to be 0.1 to 2 μg/ml, with the regression coefficient of 0.999. This method was validated according to ICH guidelines. Quantification was done by calculating area of the peak and the detection limit and quantitation limit ware 0.026 μg/ml and 0.1 μg/ml, respectively. There was no significant difference in the intra day and inter day analysis of voriconazole determined for three different concentrations using this method. Present method can be applied for the determination of voriconazole in quality control of formulation without interference of the excipients.  相似文献   

8.
A simple, specific, accurate and stability indicating reversed phase high performance liquid chromatographic method was developed for the simultaneous determination of atorvastatin calcium and amlodipine besylate in tablet dosage forms. A phenomenex Gemini C-18, 5 μm column having 250×4.6 mm i.d. in isocratic mode, with mobile phase containing 0.02 M potassium dihydrogen phosphate:acetonitrile:methanol (30:10:60, v/v/v) adjusted to pH 4 using ortho phosphoric acid was used. The flow rate was 1.0 ml/min and effluents were monitored at 240 nm. The retention times of atorvastatin calcium and amlodipine besylate were 11.6 min and 4.5 min, respectively. The calibration curves were linear in the concentration range of 0.08-20 μg/ml for atorvastatin calcium and 0.1-20 μg/ml for amlodipine besylate. Atorvastatin calcium and amlodipine besylate stock solutions were subjected to acid and alkali hydrolysis, chemical oxidation and dry heat degradation. The degraded product peaks were well resolved from the pure drug peak with significant difference in their retention time values. The proposed method was validated and successfully applied to the estimation of atorvastatin calcium and amlodipine besylate in combined tablet dosage forms.  相似文献   

9.
Two UV-spectrophotometric and one reverse phase high performance liquid chromatography methods have been developed for the simultaneous estimation of amlodipine besilate, losartan potassium and hydrochlorothiazide in tablet dosage form. The first UV spectrophotometric method was a determination using the simultaneous equation method at 236.5, 254 and 271 nm over the concentration range 5-25, 10-50 and 5-25 μg/ml for amlodipine besilate, losartan potassium and hydrochlorothiazide, respectively. The second UV method was a determination using the area under curve method at 231.5-241.5, 249-259 and 266-276 nm over the concentration range of 5-25, 5-25 and 10-50 μg/ml for amlodipine besilate, hydrochlorothiazide and losartan potassium, respectively. In reverse phase high performance liquid chromatography analysis is carried out using 0.025 M phosphate buffer (pH 3.7):acetonitrile (57:43 v/v) as the mobile phase and Kromasil C18 (4.6 mm i.d×250 mm) column as stationery phase with detection wavelength of 232 nm linearity was obtained in the concentration range of 2-14, 20-140 and 5-40 μg/ml for amlodipine besilate, losartan potassium and hydrochlorothiazide, respectively. Both UV-spectrophotometric and reverse phase high performance liquid chromatography methods were statistically validated and can be used for analysis of combined dose tablet formulation containing amlodipine besilate, losartan potassium and hydrochlorothiazide.  相似文献   

10.
A simple, reproducible and efficient reverse phase high performance liquid chromatographic method was developed for simultaneous determination of valsartan and hydrochlorothiazide in tablets. A column having 200 × 4.6 mm i.d. in isocratic mode with mobile phase containing methanol:acetonitrile:water:isopropylalcohol (22:18:68:2; adjusted to pH 8.0 using triethylamine; v/v) was used. The flow rate was 1.0 ml/min and effluent was monitored at 270 nm. The retention time (min) and linearity range (μg/ml) for valsartan and hydrochlorothiazide were (3.42, 8.43) and (5-150, 78-234), respectively. The developed method was found to be accurate, precise and selective for simultaneous determination of valsartan and hydrochlorothiazide in tablets.  相似文献   

11.
A simple, fast, and efficient RP-HPLC method has been developed and validated for the simultaneous estimation of Levodropropizine, Chloropheniramine, Methylparaben, Propylparaben, and the quantification of Levodropropizine impurities in the Reswas syrup dosage form. A gradient elution method was used for the separation of all the actives and Levodropropizine impurities by using the X-Bridge C18, 150 mm × 4.6 mm, 3.5 μm column with a flow rate of 1.0 mL/min and detector wavelength at 223 nm. The mobile phase consisted of a potassium dihydrogen orthophosphate buffer and acetonitrile. All the peaks were symmetrical and well-resolved (resolution was greater than 2.5 for any pair of components) with a shorter run time. The limit of detection for Levodropropizine and its Impurity B was 0.07 μg/ml & 0.05 μg/ml, whereas the limit of quantification was 0.19 μg/ml & 0.15 μg/ml respectively. The method was validated in terms of precision, accuracy, linearity, robustness, and specificity. Degradation products resulting from the stress studies were well-resolved and did not interfere with the detection of Levodropropizine, Chloropheniramine, Methylparaben, Propylparaben, and Levodropropizine Impurity B, thus the test method is stability-indicating. Validation of the method was carried out as per International Conference on Harmonization (ICH) guidelines.  相似文献   

12.
A fast, robust and stability indicating RP-HPLC method was developed for simultaneous determination of bisoprolol fumarate and amlodipine besylate in tablets. The mobile phase was mixture of 25 mM ammonium acetate adjusted to pH 5.0 and methanol (65: 35) at 0.8 ml/min. The stationary phase was Luna C18-2 column (3 μ, 50×4.6 mm ID). UV detection was performed at 230 nm. Retention time was 1.45 min and 3.91 min for bisoprolol and amlodipine, respectively. Linearity was established in the range of 8–33 μg/ml. Mean recovery was 99.1% and 98.6% for bisoprolol fumarate and amlodipine besylate, respectively.  相似文献   

13.
A simple, specific, accurate and stability-indicating reversed phase high performance liquid chromatographic method was developed for the simultaneous determination of mephenesin and diclofenac diethylamine, using a Spheri-5-RP-18 column and a mobile phase composed of methanol: water (70:30, v/v), pH 3.0 adjusted with o-phosphoric acid. The retention times of mephenesin and diclofenac diethylamine were found to be 3.9 min and 14.5 min, respectively. Linearity was established for mephenesin and diclofenac diethylamine in the range of 50-300 μg/ml and 10-60 μg/ml, respectively. The percentage recoveries of mephenesin and diclofenac diethylamine were found to be in the range of 99.06-100.60% and 98.95-99.98%, respectively. Both the drugs were subjected to acid, alkali and neutral hydrolysis, oxidation, dry heat, photolytic and UV degradation. The degradation studies indicated, mephenesin to be susceptible to neutral hydrolysis, while diclofenac diethylamine showed degradation in acid, H2O2, photolytic and in presence of UV radiation. The degradation products of diclofenac diethylamine in acidic and photolytic conditions were well resolved from the pure drug with significant differences in their retention time values. This method can be successfully employed for simultaneous quantitative analysis of mephenesin and diclofenac diethylamine in bulk drugs and formulations.  相似文献   

14.
A rapid and accurate liquid chromatographic method is described for the simultaneous determination of roxithromycin and ambroxol hydrochloride in a new tablet formulation. Chromatographic separation of the two drugs was achieved on a Diamonsil™ C18 column (200 mm×4.6 mm, 5 μm). The mobile phase consisting of a mixture of acetonitrile, methanol and 0.5% ammonium acetate (39:11:50 (v/v), pH 5.5) was delivered at a flow rate of 1.0 ml/min. Detection was performed at 220 nm. Linearity, accuracy and precision were found to be acceptable over the concentration range of 201.2–2012.0 μg/ml for roxithromycin and 42.7–427.0 μg/ml for ambroxol hydrochloride, respectively. Separation was complete in less than 10 min. The proposed method can be used for the quality control of formulation products.  相似文献   

15.
A rapid, simple, sensitive and selective analytical method was developed by using reverse phase ultra performance liquid chromatographic technique for the simultaneous estimation of bambuterol hydrochloride and montelukast sodium in combined tablet dosage form. The developed method is superior in technology to conventional high performance liquid chromatography with respect to speed, resolution, solvent consumption, time, and cost of analysis. Elution time for the separation was 6 min and ultra violet detection was carried out at 210 nm. Efficient separation was achieved on BEH C18 sub-2-μm Acquity UPLC column using 0.025% (v/v) trifluoro acetic acid in water and acetonitrile as organic solvent in a linear gradient program. Resolutions between bambuterol hydrochloride and montelukast sodium were found to be more than 31. The active pharmaceutical ingredient was extracted from tablet dosage from using a mixture of methanol, acetonitrile and water as diluent. The calibration graphs were linear for bambuterol hydrochloride and montelukast sodium in the range of 6.25-37.5 μg/ml. The percentage recoveries for bambuterol hydrochloride and montelukast sodium were found to be in the range of 99.1-100.0% and 98.0-101.6%, respectively. The test solution was found to be stable for 7 days when stored in the refrigerator between 2-8°. Developed UPLC method was validated as per International Conference on Harmonization specifications for method validation. This method can be successfully employed for simultaneous estimation of bambuterol hydrochloride and montelukast sodium in bulk drugs and formulations.  相似文献   

16.
Liquid chromatographic method was developed for simultaneous quantitative determination of dicyclomine hydrochloride, mefenamic acid and paracetamol in their combined dosage form. The separation was achieved using a C18 column (250×4.6 mm id, 5 μm) using acetonitrile:20 mM potassium dihydrogen phosphate 70:30 (v/v) adjusted to pH 4 using orthophosphoric acid as mobile phase at a flow rate of 1 ml/min and detection at 220 nm. Separation was completed within 12 min. The retention times of dicyclomine hydrochloride, mefenamic acid and paracetamol were 3.8, 9.3 and 2.5 minutes respectively. The proposed method was found to have linearity in concentration range of 10–100 μg/ml for dicyclomine hydrochloride, 0.05-10 μg/ml for mefenamic acid and 0.1−20 μg/ml for paracetamol. The developed method has been statistically validated and was found to be simple, precise, reproducible and accurate. The developed and validated method was successfully used for the quantitative analysis of commercially available dosage form.  相似文献   

17.
A simple, precise, accurate and economic simultaneous UV spectrophotometric method has been developed for the estimation of amlodipine besylate, valsartan and hydrochlorothiazide in combination in bulk mixture and tablet. The estimation was based upon measurement of absorbance at absorbance maxima of 359 nm, 317 nm and 250 nm for amlodipine besylate, hydrochlorothiazide and valsartan in methanol, respectively in bulk mixture and tablet. The Beer Lambert''s law obeyed in the concentration range 5-25 μg/ml, 10-50 μg/ml and 5-25 μg/ml for amlodipine besylate, hydrochlorothiazide and valsartan, respectively. The estimation of bulk mixture and tablet was carried out by simultaneous equation, Q-analysis and area under curve method for estimation of amlodipine besylate and hydrochlorothiazide and standard curve method for estimation of valsartan. The results were found to be in the range of 99.6±1.52% to 102±0.51%. Method was validated with respect to specificity, linearity, range, accuracy, precision, LOD, LOQ, robustness, ruggedness and can be applied for routine analysis of tablet dosage forms.  相似文献   

18.
A new, simple, precise, rapid and accurate RP-HPLC method has been developed for the simultaneous estimation of cefpodoxime proxetil and clavulanic acid from pharmaceutical dosage forms. The method was carried out on a Zorbax Eclipse XDB 5 μ C 18 (150×4.6 mm) column with a mobile phase consisting of acetonitrile:50 mM potassium dihydrogen phosphate buffer (pH 3.0, 70:30 v/v) at a flow rate of 1.0 ml/min. Detection was carried out at 228 nm. Aspirin was used as an internal standard. The retention time of clavulanic acid, cefpodoxime proxetil and aspirin was 4.43, 6.44 and 5.6 min, respectively. The developed method was validated in terms of accuracy, precision, linearity, limit of detection, limit of quantification and solution stability. The proposed method can be used for the estimation of these drugs in combined dosage forms.  相似文献   

19.
A stability-indicating reverse phase high performance liquid chromatography method was developed and validated for cefixime and linezolid. The wavelength selected for quantitation was 276 nm. The method has been validated for linearity, accuracy, precision, robustness, limit of detection and limit of quantitation. Linearity was observed in the concentration range of 2-12 μg/ml for cefixime and 6-36 μg/ml for linezolid. For RP-HPLC, the separation was achieved by Phenomenex Luna C18 (250×4.6 mm) 5 μm column using phosphate buffer (pH 7):methanol (60:40 v/v) as mobile phase with flow rate 1 ml/min. The retention time of cefixime and linezolid were found to be 3.127 min and 11.986 min, respectively. During force degradation, drug product was exposed to hydrolysis (acid and base hydrolysis), H2O2, thermal degradation and photo degradation. The % degradation was found to be 10 to 20% for both cefixime and linezolid in the given condition. The method specifically estimates both the drugs in presence of all the degradants generated during forced degradation study. The developed methods were simple, specific and economic, which can be used for simultaneous estimation of cefixime and linezolid in tablet dosage form.  相似文献   

20.
In this study, a rapid, precise, accurate, specific and sensitive ion-paired reverse phase liquid chromatographic method has been developed for the simultaneous estimation of nebivolol hydrochloride and valsartan in their capsule formulation. The chromatographic method was standardized using a HIQ sil C18 column (250×4.6 mm i.d., 5 μm particle size) with UV detection at 289 nm and flow rate of 1 ml/min. The mobile phase consisting of methanol:water (80:20 v/v) with addition of 0.1 percent 1-hexanesulfonic acid monohydrate sodium salt as an ion-pairing reagent was selected. The method was validated and produced accurate and precise results for estimation of the two drugs.  相似文献   