首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BACKGROUND: Non-penetrating, arcuate-legged vascular-closure staple clips made of titanium were initially developed for microvascular anastomoses with little experience of their use in larger vessels. The purpose of this study was to compare vascular-closure staple clips to sutured anastomoses in common iliac arteries in a porcine model. METHODS: In an experimental study, transected iliac arteries on both sides of 11 pigs were randomly assigned to end-to-end anastomosis performed with vascular-closure staple clips or interrupted 6-0 polypropylene sutures. Angiographic, macroscopic and microscopic results were assessed after 2 months. RESULTS: There was no significant difference in the patency rate, tensile strength of the anastomoses, vessel diameter at the repair site, intimal thickness or wall thickness of the arteries after either method of closure. The mean (s.d.) clamp time was 19.8 (6.1) minutes for clip repair, and 36.0 (6.9) seconds for suture repair (P < 0.001). The times required for the reconstruction of the anastomoses were 17.4 (6.1) and 35.5 (7.1) minutes, respectively (P < 0.001). CONCLUSIONS: Arterial anastomoses performed with vascular-closure staple clips are faster than sutured anastomoses, and result in comparable wound healing when assessed for patency, tensile strength, degree of narrowing and intimal reaction.  相似文献   

2.
BACKGROUND: The use of a self-closing nitinol surgical clip (Coalescent Surgical U-Clip) is a novel technique of creating an interrupted vascular anastomosis, which also eliminates the knot tying associated with a conventional vascular anastomosis. The purpose of this study was to compare the clinical outcome of arteriovenous fistulae (AVF) for hemodialysis as constructed using interrupted U-Clip devices and conventional continuous polypropylene sutures. METHODS: We prospectively studied the clinical course of 132 patients (149 access) undergoing either forearm autologous arteriovenous fistula (FAVF, n = 69) or upper arm autologous arteriovenous fistula (UAVF, n = 80) or creations during a 39-month period. Among the FAVF, U-Clips and polypropylene sutures were used in 37 and 32 anastomoses, respectively. Among the UAVF, U-Clips and polypropylene sutures were used in 41 and 30 anastomoses, respectively. Primary patency, complication, and maturation rates were analyzed. RESULTS: Clipped FAVF had an improved maturation rate at 6 weeks (32 of 37, 86%) when compared with sutured FAVF (22 of 32, 69%, P <0.05). There was no difference in the maturation rate among UAVF constructed with either U-Clips or sutures (88% versus 87%, not significant). The primary patency rates at 12, 24, and 36 months were 91%, 84%, and 75% for the clipped FAVF; and 83%, 74%, and 61% for the sutured FAVF (P <0.05) There was no difference in the patency rate of UAVF constructed with either U-Clips or polypropylene sutures at either 12, 24 or 36 moths (91%, 80%, and 75% versus 83%, 77%, and 69%, respectively). CONCLUSIONS: The U-Clips are a viable alternative to sutures for creating vascular anastomosis. It provides a improved maturation and patency rates when compared with the conventional sutured AVF in the forearm. The clinical benefit of the U-Clips may be due in part to the improved compliance created by the interrupted anastomotic technique.  相似文献   

3.
PURPOSE: The gross, light microscopic, and scanning microscopic appearance of arterial and venous anastomoses in expanded polytetrafluoroethylene (ePTFE) access grafts constructed with nonpenetrating clips were compared with that of those constructed with polypropylene suture. We hypothesized that clip-constructed anastomoses would provide controlled approximation of native vessel intimal and medial components with the ePTFE grafts. We further hypothesized that anastomotic healing with clips would involve primarily an intimal cellular response, as compared with suture-constructed anastomoses in which cells within the media and adventitia walls participate. METHODS: Femoral artery to femoral vein arteriovenous (AV) grafts were constructed in five dogs using 4-mm internal diameter ePTFE graft material. Each animal received one AV graft with anastomoses constructed by using polypropylene sutures in one leg and one AV graft with anastomoses constructed with Vascular Closure System clips in the contralateral leg. Animals were given aspirin for the duration of the study, and grafts were explanted at 5 weeks. At the time of explantation, graft segments were grossly evaluated and then underwent light and scanning electron microscopic analysis. RESULTS: At the time of explantation, all access grafts were patent. Joining the ePTFE grafts to the native vessels with clips resulted in minimal vessel wall damage. The lumenal contours of the discontinuous approximation were smooth and without gross endothelial disruption. These observations are in contrast to the lumenal compromise and endothelial disturbance associated with the sutured anastomoses. Furthermore, hemostasis was achieved immediately in the clipped grafts, decreasing the incidence of perianastomic hematoma. Finally, cellular reconstitution occurred at the anastomotic cleft in both the sutured and the clipped junctions. The neointima exhibited an endothelial cell lining on the lumenal surface and the presence of alpha-smooth muscle cell actin positive cells within the subendothelial layer. CONCLUSION: Vascular Closure System clips are a viable alternative to suture for the approximation of ePTFE AV access grafts to native blood vessels. The use of the clips resulted in a more streamlined anastomosis, with decreased vessel wall damage, immediate hemostasis, and a trend toward shorter procedure times.  相似文献   

4.
OBJECTIVE: There is an urgent and compelling need to reduce the morbidity and expense of maintaining hemodialysis vascular access patency. This large, long-term, retrospective, multicenter study, which compared access patency of autogenous arteriovenous fistulas (AVF) and synthetic bridge grafts (AVG) created with conventional sutures or nonpenetrating clips, was undertaken to resolve conflicting results from previous smaller studies. DESIGN: Patency data for 1385 vascular access anastomoses (clipped or sutured) was obtained from 17 hospitals and dialysis centers (Appendix). Five hundred eighteen AVF (242 clip, 276 suture) and 827 AVG (440 clip, 384 suture) were analyzed. Statistical comparisons were made with Kaplan-Meier survival analysis, log-rank test, two-sample t test, and X(2) test. The Cox proportional hazards model was used to confirm Kaplan-Meier analysis. RESULTS: Access patency (primary, secondary, overall, and intention to treat) was significantly improved in access anastomoses constructed with clips. In the intention-to-treat group, primary patency at 24 months was 0.54 for clipped AVF and 0.34 for sutured AVF, and was 0.36 for clipped AVG and 0.17 for sutured AVG. At 24 months, primary patency rate for AVF successfully used for dialysis was 0.67 for clips and 0.48 for sutures, and for AVG was 0.39 for clips and 0.19 for sutured constructs. Interventions necessary to maintain patency were significantly fewer in clipped anastomoses. CONCLUSION: Replacing conventional suture with clips significantly reduces morbidity associated with maintaining permanent hemodialysis vascular access. This beneficial effect may be due to the biologic superiority of interrupted, nonpenetrating vascular anastomoses.  相似文献   

5.
BACKGROUND: Vascular repair with sutures is associated with disruption of the endothelial lining and subsequent thrombus formation on the intraluminal lesions. This experimental study was designed to determine whether the use of non-penetrating clips improved endothelial preservation. METHODS: In ten female pigs, 25-mm arteriotomies were made in both carotid arteries. The arteriotomies were repaired with jugular vein patches. On the left side, the repair was done with 1.4-mm titanium clips, and on the right side with two running 6/0 polypropylene sutures. Next, the aorta was divided and subsequently repaired with 2-mm clips in five of these pigs, and with two running 5/0 polypropylene sutures in the remaining five pigs. Endothelial function was studied at the anastomotic site in the carotid arteries by determination of endothelium-dependent and -independent relaxatory responses. Morphometric examination of the carotid arteries and inspection of the aortic endothelium were performed by means of scanning electron microscopy. RESULTS: Maximal endothelium-dependent relaxation to adenosine 5'-diphosphate was less in sutured than in clipped carotid arteries (P < 0.05), while there was no difference in maximal endothelium-independent relaxation to sodium nitrite. This result in clipped carotid arteries was not accompanied by less intimal hyperplasia. Screening of the aortic anastomotic line showed better preservation of endothelial architecture after clip anastomosis. Mean cross-clamp time for carotid patch repair was significantly less when using clips than with sutures. CONCLUSION: The use of non-penetrating clips for vascular anastomoses preserved endothelial function and structural integrity better than running sutures, although the degree of intimal hyperplasia was similar.  相似文献   

6.
In search of the "perfect" anastomosis   总被引:2,自引:0,他引:2  
Forty-five end-to-side microvascular anastomoses were completed in rat carotid arteries of 0.7-0.8 mm diameter (anastomosing the distal end of the left common carotid to the side of the right common carotid). For comparison both 10-0 and 11-0 sutures were utilized in different anastomotic techniques: interrupted, direct-continuous, and diagonal-continuous sutures, plus total mural thickness vs. partial mural thickness (piercing only the adventitia and outer media, excluding the intima). Anastomoses were evaluated for patency and scanning electron microscopic appearance after 10 to 12 weeks. The results indicate complete patency in all anastomoses. Ultrastructural observations revealed nearly normal intimal appearance in the partial medial technique and only minimal evidence of intimal injury in the other techniques. It is concluded that 100% patency can be obtained regardless of suture size or anastomotic technique. The most important factor in anastomotic patency is the operator's technical skill.  相似文献   

7.
There is an urgent and compelling need to reduce the morbidity and expense of maintaining hemodialysis vascular access patency. We previously reported the beneficial effects of altering anastomotic technique on vascular access patency from a multicenter clinical trial. Interrupted anastomoses created with nonpenetrating clips showed significant improvement in primary, assisted primary, and secondary patencies of native vein fistulae (AVF) and synthetic arteriovenous grafts (AVG). In the current report, we provide an analysis of the economic impact of these procedures. The economic analysis is based on a subgroup of patients who underwent access procedures as outpatients during years 1998-1999 at a university-affiliated hospital that contributed 23% of procedures described in the multicenter clinical trial. Hospital charges and payments received were determined for fistula placement and for commonly performed surgical and endovascular procedures (thrombectomy and angioplasty) that maintain patency. Financial comparisons were based on the hospital's average accumulative charges and actual payments calculated on a daily basis. Cost curves were generated by using charge and payment data. Financial information was extrapolated to the entire study population to estimate the cost savings for the larger group. Both charge and payment calculations indicated financial benefit with the use of clips. When financial estimates were extrapolated to reflect the national volume, clip usage projected significant savings of $20 million for AVF and $30.8 million for AVG for every 1,000 days of access patency. Replacing conventional sutures with clips can reduce the morbidity and cost associated with maintaining permanent hemodialysis vascular accesses. This beneficial effect may be due to the biologic advantages of interrupted, nonpenetrating vascular anastomoses.  相似文献   

8.
OBJECTIVE: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. METHODS: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = pi x mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC=Delta CSAA/Delta P where Delta P is the mean pulse pressure and Delta CSAA is the mean CSAA during cardiac cycle. RESULTS: We collected a total of 1200000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94+/-0.4 mm(2) and a mean CSAA in diastole of 26.30+/-0.5 mm(2) (mean Delta CSAA was 0.64 mm(2)). CSAC for running suture was 4.5 x 10(-6)m(2)/kPa. For interrupted suture we had a mean CSAA in systole of 21.98+/-0.2 mm(2) and a mean CSAA in diastole of 17.38+/-0.3 mm(2) (mean Delta CSAA was 4.6+/-0.1 mm(2)). CSAC for interrupted suture was 11 x 10(-6) m(2)/kPa. CONCLUSIONS: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomoses.  相似文献   

9.
Abstract. Purpose: To evaluate whether nonpenetrating vascular closure staples (VCS) and hepatocyte growth factor (HGF) can effectively prevent anastomotic intimal hyperplasia. Methods: An expanded polytetrafluoroethylene graft, 2 mm in diameter, was implanted in the common carotid artery of rabbits divided into three experimental groups. In the control group, distal anastomosis was performed with interrupted suturing; in the VCS group, clips were applied along the lateral suture line after the placement of stay sutures; and in the VCS + HGF group, the same anastomotic technique was performed as in the VCS group, followed by the administration of the HGF for 4 days. Results: The time taken to complete the anastomosis was significantly less in both the VCS groups than in the control group (P < 0.0001). On postoperative day (POD) 28, the patency rate was significantly lower (P < 0.05) in the VCS group (42.9%) than in the control group (100%), but the rate in the VCS + HGF group (100%) was the same as that in the control group. Intimal thickness was significantly less in the control group than in either the VCS or VCS + HGF groups (P < 0.05). The percentage of area stenosis was significantly less (P < 0.01) in the control group than in the VCS group. Conclusion: The VCS clip failed to suppress intimal thickness or reduce the percentage of stenosis at the anastomotic site. Received: July 13, 2001 / Accepted: November 20, 2001  相似文献   

10.
Suture technique and para-anastomotic compliance   总被引:2,自引:0,他引:2  
We previously described a para-anastomotic hypercompliant zone (PHZ), located 3 to 4 mm from end-to-end continuous anastomoses in canine femoral arteries, in which arterial compliance first increases approximately 50% above adjacent reference values before falling to a minimum at the anastomosis. To determine if PHZ is affected by suture technique, 16 interrupted and 21 continuous end-to-end anastomoses were studied. Pulsed ultrasound was used to obtain detailed longitudinal profiles of compliance and diameter vs. distance, at 1 mm intervals within a 2 cm region centered at the anastomoses. Both compliance and diameter at the anastomosis were lower in continuous compared with interrupted anastomoses (p less than 0.003). The PHZ was present in 86% of continuous but in only 50% of interrupted anastomoses (p less than 0.03). The site of peak compliance averaged 3.8 +/- 1.2 mm from the anastomosis and was independent of suture technique. The increase in peak compliance at the PHZ, when normalized to adjacent references values, was the same in continuous and interrupted anastomoses. PHZ augments any preexisting compliance mismatch between artery and graft, which may contribute to the development of para-anastomotic subintimal hyperplasia. Interrupted anastomoses, which create a smaller compliance mismatch than do continuous and have a lower incidence of PHZ, may be preferred in certain settings.  相似文献   

11.
Comparison of anastomotic suturing techniques in the rat esophagus.   总被引:2,自引:0,他引:2  
BACKGROUND: Long-gap esophageal atresia continues to be a challenging pediatric thoracic surgical problem. Despite the use of various tension relieving procedures, the esophageal anastomosis is often performed under considerable tension. Excessive tension can cause anastomotic sutures to pull through the esophageal tissue, with resultant early esophageal anastomotic dehiscence. To test the hypothesis that interrupted horizontal mattress sutures would withstand the forces of tension better than interrupted simple sutures, an experimental study of rat esophageal anastomoses was done. METHODS: Twenty rats were killed and their esophagi were excised. The esophagi were divided in the mid portion and end-to-end anastomoses were done using interrupted 6-0 polypropylene sutures. Ten rats had anastomoses done with interrupted simple sutures and ten had interrupted horizontal mattress suturing. Anastomotic breaking strength was tested in a tensiometer. RESULTS: Anastomotic breaking strength was 3.22+/-0.56 N for the interrupted simple sutured anastomoses and 3.51+/-0.61 N for the interrupted horizontal mattress group (p=0.30). The difference was not significant. CONCLUSIONS: In this animal study interrupted simple and horizontal mattress suturing withstood the disruptive forces of anastomotic tension equally well.  相似文献   

12.
To date, the gold standard for performing a microvascular anastomosis has been the penetrating suture with attached needle. During the last two decades, non-penetrating techniques have been introduced, including the Unilink system for end-to-end anastomoses, and the VCS clip-applier system for both end-to-end and end-to-side anastomoses. The aim of this study was to compare the results of different techniques used to create microvascular anastomoses in free-flap reconstructions. Between January 1995 and October 1999, we performed 474 microvascular anastomoses in 216 consecutive free-tissue transfers. The anastomosis techniques included manual sutures (42%), Unilink rings (34%) and VCS clips (24%). Seven combined sutured-clipped anastomoses were excluded from further analysis. The mean anastomotic time when rings were applied was significantly shorter than when using clips (P 0.0001) or sutures (P 0.0001). Venous anastomoses using clips took less time than those using sutures (P 0.05). There were 19 anastomotic failures, all of which lead to early flap failure. Ten flaps were salvaged by early reoperation; nine flaps were lost. Three more flaps were lost as a result of other causes, bringing the flap survival rate down to 94.4%. Early flap failure was caused by failure of the arterial anastomosis in eight cases; all of them were sutured (these represented 5% of all arterial anastomoses with sutures). None of the clipped arterial anastomoses failed. Early flap failure was caused by failure of the venous anastomosis in 11 patients. Three of these anastomoses were sutured (representing 6% of all venous anastomoses with sutures), seven were anastomosed with rings (representing 5% of all venous anastomoses with rings) and one was clipped (representing 2% of all venous anastomoses with clips). Both the VCS clip-applier system and the Unilink system are easy to handle and allow fast microvascular anastomoses without intraluminal penetration. The patency rate of clipped vessels is at least as good as the patency rates of vessels anastomosed using sutures or rings.  相似文献   

13.
This study compared the growth of vascular anastomoses performed with either polypropylene or polydioxanone sutures and with either continuous running suture or interrupted suture technique. Primary end-to-end anastomoses of the infrarenal aorta were performed in 38 puppies. Nineteen were performed with 5-0 polypropylene sutures; in ten all sutures were placed in continuous fashion, and in nine in interrupted fashion. The other nineteen were performed with 5-0 polydioxanone sutures; in ten the sutures were placed in continuous fashion, and in nine in interrupted fashion. The animals were subjected to the repeated aortograms at 2, 4, 8 weeks, 6 months and 1 year following operation. Each abdominal aorta was subjected to burst test, and pathological examination. All anastomoses were patent and tolerated burst-test (300 mmHg). Neither aneurysm nor dilatation of anastomotic site was observed. Anastomotic area was significantly smaller and more stenotic in the continuous polypropylene suture group than in other three groups at 8 weeks, 6 months and 1 year following operation. There was no significant difference among these three groups. No suture materials were observed in the polydioxanone suture groups after 6 months following operation. This study suggests that polydioxanone suture will be useful for the repair of cardiovascular anomalies where growth of the suture line is required.  相似文献   

14.
Nonpenetrating vascular clips for small-caliber anastomosis   总被引:2,自引:0,他引:2  
In the search for better anastomosing techniques, an improved vascular stapler device (VCS clip applier system(R)) has been introduced. The system uses nonpenetrating clips to approximate everted vessel walls. The objective of this study was to determine the effects of nonpenetrating vascular clips on endothelial wound healing. Aortic end-to-end anastomoses were performed in male Wistar rats. A comparison was made between clipped (n = 12) and conventional hand-sewn (n = 6) anastomoses. Patency rates were verified at different time intervals (after 1, 4, and 8 weeks), after which the anastomotic sites were removed. Morphological evaluation was carried out using scanning electron microscopy. All rats survived the procedure. Closure with clips took less time than closure with conventional sutures, with decreasing aortic clamping times for the clipped procedures during the course of the experiments. Patency rates were 100% in both the "clipped" and "sutured" groups. Microscopic examination showed favorable endothelial healing at the clipped anastomotic sites, with less inflammatory reaction at 1 week, and a more complete endothelial regeneration at 4 and 8 weeks follow-up, as compared with the sutured anastomoses. The clip applier holds the promise of a useful device in anastomosing small-caliber vessels, since clip closure takes less time than suturing, while patency rates are identical, and morphological results are favorable. Training is mandatory to obtain technical skills and to achieve optimal results.  相似文献   

15.
BACKGROUND: compliance mismatch is an important factor in the development of myointimal hyperplasia in both coronary and vascular anastomoses. This mismatch may be reduced by the use of newer suture materials and techniques. This review discusses the current techniques and materials used to date in generating anastomoses in both coronary and vascular applications and to correlate these with the degree of inherent compliance achieved. METHODS: PubMed, ISIS, CAS and PAS database searches were performed. Other articles were cross-referenced. RESULTS AND CONCLUSION:continuous suture is still the most used technique in both cardiac and vascular surgery for the generation of anastomoses due to the reduced time and improved haemostasis. However, continuous suture results in a greater compliance mismatch than the interrupted technique. Vein cuffs and patches improve compliance and transmission of pulsatile blood flow and offer improvement of graft patency. Alternative to sutures are biological glue, clips and laser generated solders all of which have shown promising results, but further work is required before they become applicable for routine use.  相似文献   

16.
Background and Objectives: The argon laser-assisted vascular anastomosis may solve the problems of conventional sutured anastomosis, such as vascular stenosis and arrest of growth owing to a foreign-body reaction to suture material. Study Design/Materials and Methods: Twelve argon laser-assisted vascular anastomoses, seven conventional anastomoses with interrupted sutures, and five conventional anastomoses with continuous sutures were performed in 12 young mongrel dogs. Results: Five months later, the external diameter at the anastomosis had increased 70.5% in the laser group, 67.0% in the interrupted suture group, and 22.9% in the continuous suture group. Histological examination of the laser-assisted anastomoses showed almost complete healing, with no granulomatous response around the anastomotic site. In the interrupted suture group, marked scaring and foreign body reactions were observed on the vessel wall at the site of the anastomosis. The continuous suture group showed more remarkable disorientation of the vascular layer and intimal hyperplasia than the interrupted suture group. Conclusion: Vascular anastomosis using the argon laser offers advantages over the conventional procedure in growing vessels.  相似文献   

17.
BACKGROUND: The purpose of this study was to have a preliminary assessment of the safety and efficacy of an automated vascular suturing device. METHODS: The device (Heartflo, Perclose/Abbott Labs, Redwood City, CA), which delivers 10 interrupted 7-0 polypropylene sutures between side-to-side arteriotomies, was evaluated in animals (8 Yorkshire pigs). RESULTS: Tissue edge capture and quality of anastomosis were highly rated. Time of anastomoses averaged 22 minutes. This time was prolonged primarily due to suture management, tying of interrupted sutures, and learning curve effects. Six of the anastomoses were hemostatic and two required an additional stitch each. Angiography and histology of the anastomosis confirmed patency and quality of the anastomosis. CONCLUSIONS: Our preliminary results indicate that the Heartflo automated anastomotic device is safe and effective. Preclinical and clinical studies to validate its acute and long-term effectiveness will commence shortly.  相似文献   

18.
Are pancreatoenteric anastomoses improved by duct-to-mucosa sutures?   总被引:7,自引:0,他引:7  
The patency of anastomoses joining the pancreas to either a Roux-Y loop of jejunum or the stomach was evaluated in 26 dogs. At a preliminary operation, the head and uncinate process of the pancreas were resected while carefully preserving the duodenal blood supply. The remaining body and tail of the pancreas were totally obstructed. After obstruction for a mean of 22 (range: 6 to 42) days, one of three anastomoses was performed: (1) inversion pancreatogastrostomy with two layers of sutures; (2) a similar inversion pancreatojejunostomy to the side of a Roux-Y jejunal loop; or (3) pancreatojejunostomy in which the major duct was joined to the jejunal mucosa with interrupted sutures. Six animals were kept for controls. Anastomotic patency was assessed after 8 to 12 weeks by pancreatography, with minimal pressures to achieve anastomotic flow recorded. Weight trends were consistent with anastomotic status. The eight dogs with duct-to-mucosa sutures clearly achieved superior anastomotic patency.  相似文献   

19.
BACKGROUND: A new sutureless technique has been introduced clinically to facilitate the process of vascular reconstruction and improve patency. The Vessel Closure System (VCS) is nonpenetrating, creates an elastomeric everted anastomosis, and is easily and reproducibly applied. The objective of this report is to review the published world experience that has accrued regarding these clips with attention to the assets, liabilities, and pitfalls associated with the new technology. DATA SOURCES: Medline search and manual cross-referencing were performed, after which 61 original articles were identified on the use of VCS clips for vascular anastomoses. RESULTS: Advantages of the clips compared with sutures include the technical ease of application, the reduced anastomotic time, the superior hemodynamics, and the improved healing pattern of the anastomosis. Disadvantages include the potential problems in atherosclerotic vessels, lack of prospective randomized long-term follow-up, and initial costs. The best clinical results have been achieved in microvascular repair, as well as with vascular access and transplantation surgery. CONCLUSIONS: The VCS clip technology has become an accepted vascular anastomosing technique, which in future could lead to the use of clips as a standard approach and the use of sutures only in case of severe atherosclerosis and other circumstances in which vessel edges are difficult to evert.  相似文献   

20.
BACKGROUND: In the progress toward "off-pump" endoscopic coronary artery surgical procedures, new techniques for coronary artery anastomoses are being developed. One such approach is the use of nonpenetrating titanium clips. We evaluated the quality of anastomoses achieved using this technique in a porcine model of saphenous vein-carotid artery grafting using scanning electron microscopy. METHODS: Bilateral saphenous vein-carotid artery interposition grafts were implanted in 10 "white race" pigs, using the nonpenetrating clips in one side of the neck and conventional hand suturing on the opposite side. One week after operation, the grafts were harvested. RESULTS: All grafts were patent 7 days after operation, and 40 anastomoses underwent scanning electron microscopic study. In all samples, the luminal surfaces of both the carotid artery and vein graft were covered by a continuous layer of endothelial cells up to the anastomosis. Anastomotic sites in all clipped samples and most of the sutured anastomoses were completely endothelialized, and anastomotic clefts were indistinguishable. However, in 25% of sutured specimens, the suture material remained clearly visible inside the lumen of the vessel, and the subendothelial matrix remained exposed, with extensive fibrin, red blood cells, and platelet deposition on its surface. CONCLUSIONS: Because the endothelial coverage consistently appeared to be complete and the subendothelial matrix was not exposed, it is likely that the risk of early anastomotic thrombosis is reduced by using the nonpenetrating titanium clips.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号