首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Tongue inspection (TI) is an important and unique diagnostic method in traditional Chinese medicine (TCM), because significant connections between various viscerae diseases and abnormalities in the tongue have been verified. In TCM, TI is simple and non invasive, but in clinical applications, TI is subjectively based on the experience and technique of physicians. To avoid this problem, optical coherence tomography (OCT) imaging is introduced here for TI. We study OCT imaging in rats in vivo from chronic gastritis group (model) and normal group (control) and quantitatively analyze the relative parameters, such as the thickness and the moisture degree of TI. Our results show that OCT images properly demonstrate the thickness of the tongue coating and the moisture degree of the tongue in both groups, and the thickness is increased in the model group from that in the normal group, while the moisture degree decreases. As a result, OCT technology has the potential to provide physicians with an objective diagnostic standard for visual TI in TCM clinical practice and research.  相似文献   

2.
Ultrahigh resolution optical coherence tomography (OCT) is an emerging imaging modality that enables noninvasive imaging of tissue with 1- to 3-microm resolutions. Initial OCT studies have typically been performed using harvested tissue specimens (ex vivo). No reports have investigated postexcision tissue degradation on OCT image quality. We investigate the effects of formalin fixation and commonly used cell culture media on tissue optical scattering characteristics in OCT images at different times postexcision compared to in vivo conditions. OCT imaging at 800-nm wavelength with 1.5-mum axial resolution is used to image the hamster cheek pouch in vivo, followed by excision and imaging during preservation in phosphate-buffered saline (PBS), Dulbecco's Modified Eagle's Media (DMEM), and 10% neutral-buffered formalin. Imaging is performed in vivo and at sequential time points postexcision from 15 min to 10 to 18 h. Formalin fixation results in increases in scattering intensity from the muscle layers, as well as shrinkage of the epithelium, muscle, and connective tissue of approximately 50%. PBS preservation shows loss of optical contrast within two hours, occurring predominantly in deep muscle and connective tissue. DMEM maintains tissue structure and optical scattering characteristics close to in vivo conditions up to 4 to 6 h after excision and best preserved tissue optical properties when compared to in vivo imaging.  相似文献   

3.
To quantify OCT images of rectal tissue for clinic diagnosis, the scattering coefficient of the tissue is extracted by curve fitting the OCT signals to a confocal single model. A total of 1000 measurements (half and half of normal and malignant tissues) were obtained from 16 recta. The normal rectal tissue has a larger scattering coefficient ranging from 1.09 to 5.41?mm(-1)?with a mean value of 2.29?mm(-1)?(std:±0.32), while the malignant group shows lower scattering property and the values ranging from 0.25 to 2.69?mm(-1)?with a mean value of 1.41?mm(-1)?(std:±0.18). The peri-cancer of recta has also been investigated to distinguish the difference between normal and malignant rectal tissue. The results demonstrate that the quantitative analysis of the rectal tissue can be used as a promising diagnostic criterion of early rectal cancer, which has great value for clinical medical applications.  相似文献   

4.
目的 通过对早期自然龋变光学相干断层成像(OCT)图像进行定量分析,寻找适于光学相干断层成像技术检测早期龋的定量参数指标.方法 选取D0期、D1期和D2期自然发生釉质龋双尖牙标本各3颗,利用光学相干断层成像分别对上述不同程度早期釉质龋人离体牙进行扫描,并以龋变区域(目标区域)平均灰度值与正常区域(背景区域)平均灰度之比...  相似文献   

5.

Background  

Optic nerve head drusen (ONHD) are white calcareous deposits, seen either superficially on the optic nerve head or buried within it. Diagnosis of ONHD is made by one or more ways: clinical exam, autofluorescence, ultrasound of the optic nerve, CT scan and/or visual field examination. The present study describes features of ONHD based on another diagnostic modality, the spectral-domain OCT (Spectralis).  相似文献   

6.
The use of high-resolution optical coherence tomography (OCT) to visualize penetration kinetics during the initial phase of chemical eye burns is evaluated. The changes in scattering properties and thickness of rabbit cornea ex vivo were monitored after topical application of different corrosives by time-resolved OCT imaging. Eye burn causes changes in the corneal microstructure due to chemical interaction or change in the hydration state as a result of osmotic imbalance. These changes compromise the corneal transparency. The associated increase in light scattering within the cornea is observed with high spatial and temporal resolution. Parameters affecting the severity of pathophysiological damage associated with chemical eye burns like diffusion velocity and depth of penetration are obtained. We demonstrate the potential of high-resolution OCT for the visualization and direct noninvasive measurement of specific interaction of chemicals with the eye. This work opens new horizons in clinical evaluation of chemical eye burns, eye irritation testing, and product testing for chemical and pharmacological products.  相似文献   

7.
We present spectral domain polarization-sensitive optical coherence tomography (SD PS-OCT) imaging of peripheral nerves. Structural and polarization-sensitive OCT imaging of uninjured rat sciatic nerves was evaluated both qualitatively and quantitatively. OCT and its functional extension, PS-OCT, were used to image sciatic nerve structure with clear delineation of the nerve boundaries to muscle and adipose tissues. A long-known optical effect, bands of Fontana, was also observed. Postprocessing analysis of these images provided significant quantitative information, such as epineurium thickness, estimates of extinction coefficient and birefringence of nerve and muscle tissue, frequency of bands of Fontana at different stretch levels of nerve, and change in average birefringence of nerve under stretched condition. We demonstrate that PS-OCT combined with regular-intensity OCT (compared with OCT alone) allows for a clearer determination of the inner and outer boundaries of the epineurium and distinction of nerve and muscle based on their birefringence pattern. PS-OCT measurements on normal nerves show that the technique is promising for studies on peripheral nerve injury.  相似文献   

8.
A new approach to distinguish normal fat, well-differentiated (WD), and dedifferentiated liposarcoma (LS) tumors is demonstrated, based on the use of optical coherence tomography (OCT). OCT images show the same structures seen with conventional histological methods. Our visual grading analysis is supported by numerical analysis of observed structures for normal fat and WDLS samples. Further development could apply the real-time and high resolution advantages of OCT for use in liposarcoma diagnosis and clinical procedures.  相似文献   

9.
Spectral domain optical coherence tomography (SD-OCT) with ultrahigh resolution can be used to measure precise structures in the context of ophthalmic imaging. We designed an ultrahigh resolution SD-OCT system based on broadband superluminescent diode (SLD) as the light source. An axial resolution of 2.2 μm in tissue, a scan depth of 1.48 mm, and a high sensitivity of 93 dB were achieved by the spectrometer designed. The ultrahigh-resolution SD-OCT system was employed to image the human cornea and retina with a cross-section image of 2048 × 2048 pixels. Our research demonstrated that ultrahigh -resolution SD-OCT can be achieved using broadband SLD in a simple way.  相似文献   

10.
An ultrahigh-resolution full-field optical coherence tomography (OCT) system has been developed for cellular-level imaging of biological media. The system is based on a Linnik interference microscope illuminated with a tungsten halogen lamp, associated with a high-resolution CCD camera. En face tomographic images are produced in real time, with the best spatial resolution ever achieved in OCT (0.7 microm x 0.9 microm, axial x transverse). A shot-noise limited detection sensitivity of 80 dB can be reached with an acquisition time per image of 1 s. Images of animal ophthalmic biopsies and vegetal tissues are shown.  相似文献   

11.
The vast majority of bladder cancers originate within 600 microm of the tissue surface, making optical coherence tomography (OCT) a potentially powerful tool for recognizing cancers that are not easily visible with current techniques. OCT is a new technology, however, and surgeons are not familiar with the resulting images. Technology able to analyze and provide diagnoses based on OCT images would improve the clinical utility of OCT systems. We present an automated algorithm that uses texture analysis to detect bladder cancer from OCT images. Our algorithm was applied to 182 OCT images of bladder tissue, taken from 68 distinct areas and 21 patients, to classify the images as noncancerous, dysplasia, carcinoma in situ (CIS), or papillary lesions, and to determine tumor invasion. The results, when compared with the corresponding pathology, indicate that the algorithm is effective at differentiating cancerous from noncancerous tissue with a sensitivity of 92% and a specificity of 62%. With further research to improve discrimination between cancer types and recognition of false positives, it may be possible to use OCT to guide endoscopic biopsies toward tissue likely to contain cancer and to avoid unnecessary biopsies of normal tissue.  相似文献   

12.
We use polarization-sensitive optical coherence tomography (PS-OCT) to monitor the wound healing process in vitro and in vivo, which are affected by various drugs. Five rabbit subjects are used for in vitro studies and another five are used for in vivo studies. The in vitro studies are conducted to compare the PS-OCT images with histopathology. For each subject, three biopsy lesions are created on each ear: one site is not treated (control); the second site is treated with sphingosylphosphorylcholine, which is expected to promote healing; and the last is administered with tetraacetylphytosphingosine, which negatively affects the healing process. Each site is examined with a PS-OCT system at 1, 4, 7, 10, and 14- days after wound generation. The variations of phase retardation values caused by the collagen morphology changes on wound sites are quantified for all cases. Our results suggest that PS-OCT may be a useful tool for visualization of collagen fiber regeneration and for quantification of various drug effects during the wound healing process.  相似文献   

13.
Nanoshell-enhanced optical coherence tomography (OCT) is a novel technique with the potential for molecular imaging and improved disease detection. However, optimization of this approach will require a quantitative understanding of the influence of nanoshell parameters on detected OCT signals. In this study, OCT was performed at 1310 nm in water and turbid tissue-simulating phantoms to which nanoshells were added. The effect of nanoshell concentration, core diameter, and shell thickness on signal enhancement was characterized. Experimental results indicated trends that were consistent with predicted optical properties-a monotonic increase in signal intensity and attenuation with increasing shell and core size. Threshold concentrations for a 2-dB OCT signal intensity gain were determined for several nanoshell geometries. For the most highly backscattering nanoshells tested-291-nm core diameter, 25-nm shell thickness-a concentration of 10(9) nanoshells/mL was needed to produce this signal increase. Based on these results, we discuss various practical considerations for optimizing nanoshell-enhanced OCT. Quantitative experimental data presented here will facilitate optimization of OCT-based diagnostics and may also be relevant to other reflectance-based approaches as well.  相似文献   

14.
Glaucoma causes damage of the nerve fiber layer, which may cause loss of retinal birefringence. Therefore, PS-OCT is a potentially useful technique for the early detection of glaucoma. We built a fiber-based PS-OCT setup that produces real-time images of the human retina in vivo, coregistered with retinal video images of the location of PS-OCT scans. Preliminary measurements of a healthy volunteer show that the double-pass phase retardation per unit of depth of the RNFL is not constant and varies with location, with values between 0.18 and 0.37 deg/microm. A trend in the preliminary measurements shows that the nerve fiber layer located inferior and superior to the optic nerve head is more birefringent than the thinner layer of nerve fiber tissue in the temporal and nasal regions.  相似文献   

15.
Heterogeneity in cardiac tissue microstructure is a potential mechanism for the generation and maintenance of arrhythmias. Abnormal changes in fiber orientation increase the likelihood of arrhythmia. We present optical coherence tomography (OCT) as a method to image myofibers in excised intact heart preparations. Three-dimensional (3-D) image sets were gathered from the rabbit right ventricular free wall (RVFW) using a microscope-integrated OCT system. An automated algorithm for fiber orientation quantification in the plane parallel to the wall surface was developed. The algorithm was validated by comparison with manual measurements. Quantifying fiber orientation in the plane parallel to the wall surface from OCT images can be used to help understand the conduction system of the specific sample being imaged.  相似文献   

16.
A novel technique for axial resolution improvement in Fourier domain optical coherence tomography (FDOCT) is presented. The technique is based on the deconvolution of modulated optical coherence tomography signals. In FDOCT, the real part of the Fourier transform of the interferogram is modulated by a frequency which depends on the position of the interferogram in k space. A slight numerical k shift results in a different modulation frequency. By adding two shifted signals, beating can appear in the A-scan. When the amount of shifting is appropriately selected, deconvolution of the resulting depth profile, using suitable modulated kernels, yields a narrower resolution width. A resolution improvement by a factor of ~7 can be achieved without the need for a broader bandwidth light source.  相似文献   

17.
Novel ultra-broad bandwidth light sources enabling unprecedented sub-2 microm axial resolution over the 400 nm-1700 nm wavelength range have been developed and evaluated with respect to their feasibility for clinical ultrahigh resolution optical coherence tomography (UHR OCT) applications. The state-of-the-art light sources described here include a compact Kerr lens mode locked Ti:sapphire laser (lambdaC = 785 nm, delta lambda = 260 nm, P(out) = 50 mW) and different nonlinear fibre-based light sources with spectral bandwidths (at full width at half maximum) up to 350 nm at lambdaC = 1130 nm and 470 nm at lambdaC = 1375 nm. In vitro UHR OCT imaging is demonstrated at multiple wavelengths in human cancer cells, animal ganglion cells as well as in neuropathologic and ophthalmic biopsies in order to compare and optimize UHR OCT image contrast, resolution and penetration depth.  相似文献   

18.
Blood, being a suspension of deformable red cells suspended in plasma, displays flow dynamics considerably more complicated than those of an ideal Newtonian fluid. Flow dynamics in blood capillaries of a few hundred micrometers in diameter are investigated using Doppler optical coherence tomography (DOCT) and Doppler amplitude optical coherence tomography (DAOCT), a novel extension of DOCT. Velocity profiles and concentration distributions of normal and rigidified in vitro red blood cell suspensions are shown to vary as functions of mean flow velocity, cell concentration, and cell rigidity. Deviation from the parabolic velocity profile expected for Pouseille flow is observed for both rigid and normal cells at low flow rates. Axial red cell migration both toward and away from the tube axis is observed for both rigid and normal cells as a function of flow velocity. Good agreement is found between our measurements, and theoretical expectations.  相似文献   

19.
20.
We describe the use of optical coherence tomography (OCT) for high-resolution, real-time imaging of three-dimensional structure and development of a Pseudomonas aeruginosa biofilm in a standard capillary flow-cell model. As the penetration depth of OCT can reach several millimeters in scattering samples, we are able to observe complete biofilm development on all surfaces of a 1 mm x 1 mm flow-cell. We find that biofilm growing at the bottom of the tube has more structural features including voids, outward projections, and microcolonies while the biofilm growing on the top of the tube is relatively flat and contains less structural features. Volume-rendered reconstructions of cross-sectional OCT images also reveal three-dimensional structural information. These three-dimensional OCT images are visually similar to biofilm images obtained with confocal laser scanning microscopy, but are obtained at greater depths. Based on the imaging capabilities of OCT and the biofilm imaging data obtained, OCT has potential to be used as a non-invasive, label-free, real-time, in-situ and/or in-vivo imaging modality for biofilm characterization.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号