首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BACKGROUND: Ventricular desynchronization caused by right ventricular pacing may impair ventricular function and increase risk of heart failure (CHF), atrial fibrillation (AF), and death. Conventional DDD/R mode often results in high cumulative percentage ventricular pacing (Cum%VP). We hypothesized that a new managed ventricular pacing mode (MVP) would safely provide AAI/R pacing with ventricular monitoring and DDD/R during AV block (AVB) and reduce Cum%VP compared to DDD/R. METHODS: MVP RAMware was downloaded in 181 patients with Marquis DR ICDs. Patients were initially randomized to either MVP or DDD/R for 1 month, then crossed over to the opposite mode for 1 month. ICD diagnostics were analyzed for cumulative percentage atrial pacing (Cum%AP), Cum%VP, and duration of DDD/R pacing for spontaneous AVB. RESULTS: Baseline characteristics included age 66 +/- 12 years, EF 36 +/- 14%, and NYHA Class II-III 36%. Baseline PR interval was 190 +/- 53 msec and programmed AV intervals (DDD/R) were 216 +/- 50 (paced)/189 +/- 53 (sensed) msec. Mean Cum%VP was significantly lower in MVP versus DDD/R (4.1 +/- 16.3 vs 73.8 +/- 32.5, P < 0.0001). The median absolute and relative reductions in Cum%VP during MVP were 85.0 and 99.9, respectively. Mean Cum%AP was not different between MVP versus DDD/R (48.7 +/- 38.5 vs 47.3 +/- 38.4, P = 0.83). During MVP overall time spent in AAI/R was 89.6% (intrinsic conduction), DDD/R 6.7% (intermittent AVB), and DDI/R 3.7% (AF). No adverse events were attributed to MVP. CONCLUSIONS: MVP safely achieves functional atrial pacing by limiting ventricular pacing to periods of intermittent AVB and AF in ICD patients, significantly reducing Cum%VP compared to DDD/R. MVP is a universal pacing mode that adapts to AVB and AF, providing both atrial pacing and ventricular pacing support when needed.  相似文献   

2.
Background: Enhanced AAI/R pacing minimizes right ventricular pacing but may permit or induce AV decoupling (AV‐DC) due to unrestricted AV intervals (AVIs). The purpose of this study was to characterize and quantify AVI behavior in a randomized trial of enhanced AAI/R pacing in ICD patients. Methods: One hundred twenty‐one patients in the Marquis ICD MVP? Study, a randomized 1‐month crossover comparison of cumulative% ventricular pacing (Cum%VP) in enhanced AAIR (MVP) vs DDD/R, were analyzed. AV‐DC was defined as ≥40% AVIs >300 ms; VA coupling (VA‐C) was defined as%V‐atrial pace (AP) intervals <300 ms. Dynamic AVI behavior and increases in Cum%VP due to AV block (AV uncoupling, AV‐UC) were characterized using Holters with real‐time ICD telemetry. Results: AV‐DC occurred in 17 (14%) of patients. Baseline PR, amiodarone, nighttime, lower rate >60 beats/min, rate response, and Cum%AP were associated with longer AVIs. Logistic regression identified baseline PR (odds ratio [OR]= 1.024, 95% confidence interval [CI] 1.007–1.042; P = 0.005), and Cum%AP (OR = 1.089, 95% CI 1.027–1.154; P = 0.004) as predictors of AV‐DC. AV‐DC was associated with ≈10‐fold increases in both Cum%VP (13.6 ± 28.3% vs 1.2 ± 3.9%; P = 0.023) due to transient AV‐UC) and VA‐C (6.0 ± 17.5% vs 0.5 ± 1.2%, P = 0.028). AV coupling (<40% AVIs >300 ms) was preserved in 104 (86%) patients. Conclusions: AV‐DC, VA‐C, and AV‐UC may be worsened or induced by enhanced AAI/R pacing. Conservative programming of lower rate and rate response should reduce the risk of AV‐DC by reducing Cum%AP.  相似文献   

3.
OBJECTIVES: The purpose of this study was to characterize interactions between normal pacing system operation and the initiating sequence of ventricular tachycardia (VT)/ventricular fibrillation (VF). BACKGROUND: Abrupt changes in ventricular cycle lengths (short-long-short, S-L-S) might initiate VT/VF. The S-L-S sequences might be passively permitted or actively facilitated by bradycardia pacing. METHODS: Initiating sequences of 1,356 VT/VF episodes in the PainFree Rx II (n = 634) and EnTrust Trial (n = 421) were analyzed with stored electrograms and by pacing mode (DDD/R, VVI/R, and Managed Ventricular Pacing [MVP]). Interactions between pacing and VT/VF initiation were classified as: non-pacing associated, pacing associated, pacing permitted, and pacing facilitated. RESULTS: Non-pacing associated (no pacing, no S-L-S) and pacing associated (ventricular pacing without S-L-S) onset accounted for 44.0% and 29.8% of all VT/VF, respectively. Pacing permitted (S-L-S sequences without ventricular pacing) episodes accounted for 6.4% (DDD/R), 20.0% (MVP), and 25.6% (VVI/R) of 1,356 VT/VF episodes. Pacing facilitated onset (S-L-S sequences actively facilitated by ventricular pacing including the terminal beat after a pause) accounted for 8.2% (MVP), 9.4% (VVI/R), and 14.8% (DDD/R) of 1,356 VT/VF episodes. Pacing facilitated S-L-S VT/VF occurred in 2.6% (MVP), 3.3% (VVI/R), and 5.2% (DDD/R) of patients with episodes and was the sole initiating sequence in approximately 1% of patients. Pause durations during pacing facilitated S-L-S differed between modes (DDD/R 793 +/- 172 ms vs. MVP 865 +/- 278 ms vs. VVI/R 1180 +/- 414 ms, p = 0.002). The majority of these episodes were monomorphic VT. CONCLUSIONS: Ventricular tachycardia/VF in some implantable cardioverter-defibrillator patients might be initiated by S-L-S sequences that are actively facilitated by bradycardia pacing operation and might constitute an important mechanism of ventricular proarrhythmia.  相似文献   

4.
双腔起搏器自动房室间期搜索功能的临床应用观察   总被引:3,自引:0,他引:3  
目的观察双腔起搏器自动AV间期搜索功能(auto AV search)减少心室起搏的有效性及对心功能和快速房性心律失常的影响。方法43例植入具有自动AV间期搜索功能的双腔DDD(R)起搏器的患者,术后6个月内随机交叉关闭或打开AV search功能各3个月,分别在第一阶段(3个月末)、第二阶段(6个月末)程控获取心室起搏百分比(Vp)、高频心房事件及测试血浆BNP值。结果43例患者按计划完成随访,AV search关闭组心室起搏(VP)比例为78.0±10.3%,心房高频事件为58±15次,血浆脑钠肽(BNP)水平为333±30pg/ml;AVsearch打开组Vp比例为15.9±4.8%,心房高频事件为29±13次,BNP65±21 pg/ml,两者相比具有显著统计学差异(P<0.01)。结论双腔起搏器的auto AV search功能可有效减少非必须的心室起搏,促进自身心室激动。  相似文献   

5.
目的观察自动AV间期搜索功能双腔起搏器减少心室起搏的有效性及对心功能和快速房性心律失常的影响。方法 100例植入DDD/R起搏器的患者(有AV搜索功能50例,无AV搜索功能50例),术后1年内程控获取右室起搏百分比、高频心房事件、检查超声心动图及测试血浆心房利钠肽(ANP)值。结果有AV搜索功能组术后3,6,12个月右室起搏百分比明显小于无AV搜索功能组(18.7%±5.6%vs 82.4%±10.2%,19.8%±6.6%vs 77.3%±9.5%,18.4%±7.3%vs 79.2%±8.6%,P均<0.05)。有AV搜索功能组左室舒张末内径、左房内径、左室射血分数均明显改善(P均<0.05);ANP水平明显降低(203.10±28.20 pg/ml vs 298.80±31.50 pg/ml,P<0.05);高频心房事件也显著减少(18±9次vs 39±11次,P<0.05)。结论有AV搜索功能起搏器明显减少病窦综合征患者右室起搏比例,改善心功能,并减少高频心房事件。  相似文献   

6.
AIM: In a prospective and randomized multicenter study using a cross-over protocol we compared the efficacy and the safety of the ELA medical mode-switch algorithm (DDD/AMC = DDD to AAI) to conventional DDD stimulation in patients with spontaneous AV conduction. PATIENTS AND METHOD: Forty-eight patients with a mean age of 67 +/- 13 years were included. Underlying heart disease was present in 54%. Pacemaker indications were paroxysmal AV block (21%), sick-sinus syndrome (46%), paroxysmal AV block + sick-sinus syndrome (31%) and tachycardia-bradycardia syndrome (8%). Patients were excluded from the study in case of a permanent 1st to 3rd degree AV block, a right bundle-branch block with QRS > 120 ms, severe coronary heart disease or idiopathic cardiomyopathy. The programming of the pacemaker was randomized to either DDD/AMC or DDD and was crossed over after 1 month. The AV interval (AVI) which was programmed in conventional DDD pacing was calculated as AVI = PR (or AR) + 30 ms at rest or as AVI = PR (or AR) - 50 ms during exercise. When the DDD/AMC mode was programmed, the AV interval was calculated automatically. We analyzed the AV interval, the frequency of ventricular pacing, the number of pacemaker-induced tachycardias, the number of atrial tachyarrhythmias, and the final programming which was left to the physician's choice. RESULTS: The AV interval after conventional DDD stimulation was 201 +/- 38 ms vs 195 +/- 28 ms with DDD/AMC (p = ns). Ventricular stimulation was significantly less often in the DDD/AMC mode than in the DDD mode (15 +/- 17% vs 48 +/- 37%, p < 0.001). Thereby the DDD/AMC algorithm led to a 69% reduction of ventricular pacing which means an approximately 5.5 months prolongation of the battery lifetime. There was no significant difference in the incidence of pacemaker-induced tachycardias. At the end of the study 77% of the physicians programmed the DDD/AMC mode. CONCLUSION: The analyzed DDD/AMC mode-switch algorithm leads to a significant reduction of ventricular pacing in patients with spontaneous AV conduction or with only paroxysmal AV block. Thereby the battery lifetime is prolonged and the incidence of complications due to ventricular pacing can be reduced.  相似文献   

7.
Aims: Unnecessary right ventricular pacing has deleterious effectsand becomes more significant when cumulative percent ventricularpacing (Cum%VP) exceeds 40% of time. The Managed VentricularPacing (MVP) mode has been shown to significantly reduce thepercent ventricular pacing compared to the DDD/R mode. Thisstudy assessed the percent of ventricular pacing in a standardpacemaker population programmed to MVP and for which patientsit is possible to achieve a Cum%VP 40%. Methods and results: Unselected, consecutive patients were implanted with a dualchamber pacemaker with a mean follow-up period of 76 days. TheCum%VP was calculated from device diagnostics between pre-hospitaldischarge (PHD) and the 1-month post implant visit. The medianCum%VP of 107 patients (age 67.2 ± 14 years; 53% male)who were programmed to MVP was 3.9%. The median Cum%VP was 1.4%in patients with sinus node disease (SND) and 28.8% in patientswith AV block (AVB). Cum%VP 40% was observed in 72% of allpatients, in 50% of AVB patients, and in 86% of SND patients. Conclusion: The MVP mode is capable of achieving a low percent of ventricularpacing in a standard pacemaker population with SND and AVB.In addition, 72% of patients in MVP mode demonstrated Cum%VP 40%.  相似文献   

8.
This study evaluated the relative hemodynamic importance of a normal left ventricular (LV) activation sequence compared to atrioventricular (AV) synchrony with respect to systolic and diastolic function. Twelve patients with intact AV conduction and AV sequential pacemakers underwent radionuclide studies at rest and Doppler echocardiographic studies at rest and during submaximal exercise, comparing atrial demand pacing (AAI) to sequential AV sensing pacing (DDD) and ventricular demand pacing (VVI). Studies at rest were performed at a constant heart rate between pacing modes, and the exercise study was performed at a constant heart rate and work load. Cardiac output was higher during AAI than during both DDD and VVI (6.2 +/- 1 vs 5.6 +/- 1 and 5.3 +/- 1 liters/min, p less than 0.05). LV ejection fraction was likewise higher during AAI (55 +/- 12 vs 49 +/- 11 vs 51 +/- 13, p less than 0.05). VVI with or without AV synchrony was associated with a paradoxical septal motion pattern, resulting in a 25% impairment of regional septal ejection fraction. In addition, LV contraction duration was more homogenous during AAI. Peak filling rate during AAI and VVI was higher than during DDD (2.86 +/- 1 and 2.95 +/- 1 vs 2.25 +/- 1 end-diastolic volume/s; p less than 0.05). During VVI, the time to peak filling was significantly shorter than during both AAI and DDD (165 +/- 34 vs 239 +/- 99 and 224 +/- 99 ms; p less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

9.
Ventricular dyssynchrony induced by ventricular pacing (VP) may predispose patients to congestive heart failure. The detrimental effects of VP are directly related to the cumulative percentage of VP (Cum%VP). Managed VP (MVP) is a novel pacing algorithm developed to minimize unnecessary VP by uncoupling atrial pacing from VP. This retrospective analysis assessed the feasibility of using MVP in pediatric patients and patients with congenital heart disease (CHD). A multicenter review evaluated all pediatric patients <22 years old and older patients with CHD that had an implanted device using a MVP algorithm. Primary outcome variables were Cum%VP and adverse events. A subgroup analysis evaluated patients that had a DDD(R) pacemaker before a MVP device and compared Cum%VP before and after initiation of MVP. From 6 centers 62 patients (mean age 21.5 +/- 9.6 years) were included; 64% had CHD. With a MVP device, mean Cum%VP was 4.3 +/- 14.6% (range 0 to 83.7): Eleven patients were eligible for subgroup analysis. Compared with DDD(R), Cum%VP significantly decreased with MVP (67.1 +/- 29.4% vs 9.2 +/- 24.8%, p = 0.002). One MVP-related adverse event occurred; a patient with intermittent atrioventricular block had symptoms with frequent nonconducted atrial depolarizations and was reprogrammed to DDD. In conclusion, MVP can be used safely and can significantly reduce unnecessary VP in pediatric patients and patients with CHD.  相似文献   

10.
The ultrashort-acting beta blocker flestolol was studied during atrial pacing and atrial fibrillation (AF) in 10 patients with Wolff-Parkinson-White syndrome. Flestolol was given as a 100-micrograms/kg bolus followed by a 10-micrograms/kg/min infusion for 15 minutes. The drug did not alter the antegrade effective refractory period of the accessory pathway or the atrial paced cycle length at which block occurred in the accessory pathway. After flestolol, the percent of preexcited QRS complexes during AF increased (60 +/- 10 vs 87 +/- 5%, p = 0.01). Despite this, the ventricular rate slowed, with increases in mean RR interval (382 +/- 20 vs 416 +/- 22 ms, p = 0.02) and in the shortest interval between preexcited QRS complexes (251 +/- 18 vs 270 +/- 17 ms, p less than 0.01). The effect of isoproterenol 3 to 5 micrograms/min was studied in 5 patients. During atrial pacing, isoproterenol decreased the antegrade refractory period and the atrial paced cycle length of block in the accessory pathway (p less than or equal to 0.05). During AF, it decreased the percent of preexcited QRS complexes, mean RR interval and shortest interval between preexcited QRS complexes (p less than 0.05). Flestolol reversed the effects of isoproterenol both during atrial pacing and AF. Thus, flestolol does not alter conduction over the accessory pathway during atrial pacing, but during AF it slows conduction over the accessory pathway and prevents isoproterenol-mediated increases in ventricular rate. This suggests that in patients with Wolff-Parkinson-White syndrome sympathetic stimulation after the onset of AF enhances conduction over the accessory pathway and is an important determinant of ventricular rate.  相似文献   

11.
OBJECTIVES: We aimed to compare the hemodynamic effects of right-atrial-paced (DDD) and right-atrial-sensed (VDD) biventricular paced rhythm on cardiac resynchronization therapy (CRT). BACKGROUND: Cardiac resynchronization therapy improves hemodynamics in patients with severe heart failure and left ventricular (LV) dyssynchrony. However, the impact of active right atrial pacing on resynchronization therapy is unknown. METHODS: Seventeen CRT patients were studied 10 months (range: 1 to 46 months) after implantation. At baseline, the programmed atrioventricular delay was optimized by timing LV contraction properly at the end of atrial contraction. In both modes the acute hemodynamic effects were assessed by multiple Doppler echocardiographic parameters. RESULTS: Compared to DDD pacing, VDD pacing resulted in much better improvement of intraventricular dyssynchrony assessed by the septal-to-posterior wall motion delay (VDD 106 +/- 83 ms vs. DDD 145 +/- 95 ms; p = 0.001), whereas the interventricular mechanical delay (difference between onset of pulmonary and aortic outflow) did not differ (VDD 20 +/- 21 ms vs. DDD 18 +/- 17 ms; p = NS). Furthermore, VDD pacing significantly prolonged the rate-corrected LV filling period (VDD 458 +/- 123 ms vs. DDD 371 +/- 94 ms; p = 0.0001) and improved the myocardial performance index (VDD 0.60 +/- 0.18 vs. DDD 0.71 +/- 0.23; p < 0.01). CONCLUSIONS: Our findings suggest that avoidance of right atrial pacing results in a higher degree of LV resynchronization, in a substantial prolongation of the LV filling period, and in an improved myocardial performance. Thus, the VDD mode seems to be superior to the DDD mode in CRT patients.  相似文献   

12.
Introduction:A dual-chamber pacemaker (DDD/R) for a sinus node disease is sometimes referred to as a physiological pacemaker as it maintains atrioventricular synchrony, however several clinical trials have proved its inferiority to a nonphysiological single-chamber ventricular back-up pacing.Patient concerns:A subject of the study is a 74-year-old woman with a sick sinus syndrome (SSS) and a previously implanted physiological DDD/R pacemaker. The SSS was diagnosed because of patient''s very slow sinus rhythm of about 36 bpm, and due to several episodes of dizziness. After the DDD/R implantation the percentage of atrial pacing approached 100%, with almost none ventricular pacing.Diagnoses:Sick sinus syndrome, complete Bachmann''s bundle block, atrial fibrillation, atrial flutter.Interventions:The patient was previously implanted with a physiological DDD/R pacemaker. Several years after the implantation, the atrial fibrillation was diagnosed and the pulmonary vein isolation was then performed by cryoablation. During the follow-up after pulmonary vein isolation, the improvement of mitral filling parameters was assessed using echocardiography. Shortly thereafter the patient developed the persistent paroxysm of a typical atrial flutter which was successfully terminated using a radiofrequency ablation. No recurrence thereof has been observed ever since (24 months).Outcomes:The atrial electrode of the pacing system was implanted within the low interatrial septal region that resulted in a reduced P-wave duration compared to native sinus rhythm P-waves. The said morphology was deformed because of the complete Bachmann bundle block. That approach, despite a nonphysiological direction of an atrial activation, yielded relatively short P-waves (paced P-wave: 179 ms vs intrinsic sinus P-wave: 237 ms). It also contributed to a significantly shorter PR interval (paced PR: 204 ms vs sinus rhythm PR: 254 ms).Conclusions:The authors took into consideration different aspects of alternative right atrial pacing sites. This report has shown that in some patients with a sinus node disease, low interatrial septal pacing can reduce the P-wave duration but does not prevent from the development of atrial arrhythmias.  相似文献   

13.
目的探讨Ⅲ度房室传导阻滞(AVB)患者不同房室间期(AVD)起搏对血流动力学及功能的影响。方法选择植入双腔起搏器的Ⅲ度AVB患者51例,按不同AVD分为前后4期:A期AVD为心房感知(SAV)90 ms、心室起搏(PAV)120 ms;B期为SAV 120 ms、PAV 150 ms;C期为SAV 150 ms、PAV 180 ms;D期为SAV 180 ms、PAV 210 ms。每期观察2个月,分别比较Ⅲ度AVB患者4期心电图QRS波时限和形态,血清氨基末端脑钠肽前体(NT-proBNP)水平及心脏超声左房内径(LAD)、左室收缩末期内径(LVDs)、左室舒张末期内径(LVDd)、室间隔厚度(IVST)、左室后壁厚度(LVPWT)、左室射血分数(LVEF)及二、三尖瓣返流等参数。结果Ⅲ度AVB患者行不同AVD起搏时LAD、LVDd、LVDs、IVST、LVPWT及LVEF无变化;而二尖瓣及三尖瓣返流随AVD的延长而依次减少;起搏QRS波时限A期较D期长(149.21±8.10 ms vs 145.27±6.94 ms,P<0.05);NT-proBNP随AVD的延长而减少(中位值分别为365.51,327.54,279.13和270.10 pg/ml)。结论Ⅲ度AVD患者不同AVD起搏对心脏血流动力学会产生影响,短期内对心脏的结构及功能影响不明显,选择起搏间期为SAV180 ms、PAV 210 ms时患者的获益最大。  相似文献   

14.
Y Otsuji  H Toda  A Kisanuki  S Nakao  H Tanaka 《Chest》1992,102(4):1199-1203
We correlated the percentage of atrial contribution to left ventricular filling (percent AC) assessed by Doppler echocardiography with the hemodynamic benefit from atrioventricular synchronous pacing assessed by direct hemodynamic measurements. Subjects comprised 40 patients who underwent electrophysiologic catheterization because of unexplained syncope or bradycardia (< 40 beats/min). Femoral arterial and pulmonary capillary wedge pressure were recorded by catheterization, and cardiac output was measured by thermodilution during temporary atrioventricular synchronous (DDD, 70 beats/min with 150 ms of atrioventricular delay) and ventricular (VVI, 70 beats/min) pacing. Mitral inflow velocity by pulsed-wave Doppler echocardiography was recorded during DDD pacing and percent AC was obtained by calculating the ratio of mitral inflow velocity area during atrial systole to total mitral inflow velocity area during early diastole and atrial systole. The mean arterial pressure and the cardiac output increased significantly (99 +/- 16 mm Hg vs 90 +/- 15 mm Hg, p < 0.001; 4.6 +/- 1.0 L/min vs 3.9 +/- 0.9 L/min, p < 0.001), and the mean pulmonary capillary wedge pressure decreased (7 +/- 4 mm Hg vs 10 +/- 4 mm Hg, p < 0.001) during DDD compared with VVI pacing. A significant positive correlation was observed between the percent AC and the increase in cardiac output (r = 0.58, n = 40, p < 0.01) or the increase in mean arterial pressure (r = 0.62, n = 38, p < 0.01) during DDD pacing. The percent AC did not significantly correlate with the decrease in pulmonary capillary wedge pressure. In conclusion, patients with larger percent AC may receive major benefit from atrioventricular synchronous pacing.  相似文献   

15.
The ability to program different atrioventricular (AV) delay intervals for paced and sensed atrial events is incorporated in the design of some newer dual chamber pacemakers. However, little is known regarding the hemodynamic benefit of differential AV delay intervals or the magnitude of difference between optimal AV delay intervals for paced and sensed P waves in individual patients. In this study, Doppler-derived cardiac output was used to examine the optimal timing of paced and sensed atrial events in 24 patients with a permanent dual chamber pacemaker. The hemodynamic effect of utilizing separate optimal delay intervals for sensed and paced events compared with utilizing the same fixed AV delay interval for both was determined. The optimal delay interval during DVI (AV sequential) pacing and VDD (atrial triggered, ventricular inhibited) pacing at similar heart rates was 176 +/- 44 and 144 +/- 48 ms (p less than 0.002), respectively. The mean difference between the optimal AV delay intervals for sensed (VDD) and paced (DVI) P waves was 32 ms and was up to 100 ms in some individuals. The difference between optimal AV delay intervals for sensed and paced atrial events was similar in patients with complete heart block and those with intact AV node conduction. At the respective optimal AV delay intervals for sensed and paced P waves, there was no significant difference in the cardiac output during VDD compared with DVI pacing. However, cardiac output significant declined during VDD pacing at the optimal AV delay interval for a paced event and during DVI pacing at the optimal interval for a sensed event.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

16.
Asynchronism and right ventricular pacing   总被引:2,自引:0,他引:2  
In patients with congenital heart block (CHB), dual-chamber pacing restores physiological heart rate and atrio-ventricular synchronization. However, patients with narrow QRS junctional escape rhythm may be deleteriously affected by long-term, permanent, apical ventricular pacing. We assessed the impact of apical ventricular pacing on echocardiographic ventricular dyssynchrony and hemodynamic parameters. METHODS: Fourteen CHB adults (23 +/- years, 58% male), with a DDD transvenous pacemaker and a junctional escape rhythm (QRS<120 ms) before implantation, were studied. Echocardiography coupled with tissue Doppler imaging (TDI) and Strain rate was performed in spontaneous rhythm (VVI mode 30/mn) and during atrio-synchronized ventricular pacing. RESULTS: The heart rate (43 +/- 09 vs 68 +/- 07: p<0.01), cardiac output (2.9 +/- 0.7 vs 3.7 +/- 0.6 L/min) and left ventricular filling time (325 +/- 38 vs 412 +/- 51 ms; p<0.01) were significantly less in the escape spontaneous rhythm compared with atrio-ventricular synchronized apical pacing. However, interventricular dyssynchrony (28 +/- 12 vs 59 +/- 25 ms, p<0.05), intra-left ventricular dyssynchrony (36 +/- 11 vs 57 +/- 29 ms; p<0.05), extent of left ventricular myocardium displaying delayed longitudinal contraction (26 +/- 10 vs 39 +/- 17%: p<0.05) were significantly less in the escape rhythm compared with paced rhythm. CONCLUSION: Once implanted with a DDD pacemaker, CHB patients present with increased cardiac output secondary to the restoration of physiological heart rate and improved diastolic function. However, the apical site is not optimal, as it creates detrimental ventricular dyssynchrony in patients with previous nearly physiological ventricular activation. Alternative pacing sites should be investigated.  相似文献   

17.
目的 观察自动AV间期搜索功能双腔起搏器减少心室起搏和高频心房事件的效果及对心功能的影响.方法 60例置入DDD/R起搏器的患者(有AV搜索功能30例,无AV搜索功能30例),术后1年内程控获取右室起搏百分比、高频心房事件,检查超声心动图,测试血浆利钠肽(BNP)值.结果 有AV搜索功能组术后6个月和12个月右室起搏百分比明显小于无AV搜索功能组[(21.2±6.0)%比(78.3±7.5)%,(19.1±6.5)%比(73.4±7.9)%,P均<0.05).AV搜索功能组左室射血分数、左室Tei指数均明显改善(0.57±0.03比0.53±0.05,0.48±0.15比0.68±0.20,P均<0.05);BNP水平明显降低[(75.2±34.5)pg/ml)比(37.0±16.4)pg/ml,P<0.05];高频心房事件也显著减少[(42±10)次比(19±11)次,P<0.05].结论 AV自动搜索功能起搏器可有效减少不必要的右室起搏及高频心房事件,改善血流动力学效应.  相似文献   

18.
AIMS: This study was designed to evaluate the effect of variation of atrioventricular (AV) interval (AVI) on left ventricular (LV) diastolic function and ANP and c-GMP levels during DDD pacing in patients with complete AV block and normal systolic function. METHODS: The study population comprised 22 patients (mean age 65.2+/-14.3, 12 males) with complete AV block. All patients underwent complete Doppler echocardiography before implantation of a DDD-pacemaker. Twenty-four hours later, patients were paced for a period of 30 min, at three different AVIs (100 ms, 150 ms and 200 ms), at rest. During each pacing period, Doppler-derived LV diastolic indices were re-evaluated and ANP and c-GMP levels were reassessed. RESULTS: Overall comparison showed a significant progressive augmentation, from 200 ms to 100 ms AVI, in transmitral E/A wave ratio (from 0.53+/-0.13 to 0.90+/-0.25, P = 0.0005) and in LV filling time (from 0.33+/-0.05 to 0.40+/-0.06s, P = 0.0005), followed by a significant progressive reduction in ANP and c-GMP levels. An AVI of 100 ms or 150 ms was associated with improved diastolic indices and lower natriuretic peptides levels, compared with the longer AVI. CONCLUSION: Programmed AVI during DDD pacing affects LV diastolic performance and plasma ANP and c-GMP levels. The assessment of these parameters constitutes a useful modality for AVI optimization.  相似文献   

19.
Left atrial appendage function in patients with different pacing modes   总被引:2,自引:0,他引:2  
Many studies suggest that patients who receive a ventricular pacemaker have a higher incidence of systemic thromboembolism compared to patients receiving a physiological pacemaker. However, the exact mechanism regarding the etiology of thromboembolism remains unclear. We evaluated the left atrial appendage (LAA) functions, using multiplane transesophageal echocardiography (TEE), in patients with different pacing modes. In order to evaluate the ejection fraction (EF), peak emptying (V(E)) and filling (V(F)) flow velocities of the LAA by TEE, we studied 31 patients (mean age 63+/-18.5 years) who had been paced for 5.0+/-2.9 years. Patients with atrial fibrillation, left ventricular dysfunction and mitral valve disease were excluded. The pacing indications were complete atrioventricular block (AVB) in 19 patients (9 VVI, 10 VDD or DDD) and sick sinus syndrome (SSS) in 12 patients (5 VVI, 7 DDD). Mean EF, V(E) and V(F) of the LAA were significantly lower in all patients with ventricular pacing (25.5+/-15.6%, 30.4+/-15.6 cm/s and 29. 1+/-19.2 cm/s, respectively) compared to those with physiologic pacing (48.5+/-16.9%, 59.6+/-16.3 cm/s, 57.9+/-18.5 cm/s, respectively) (P<0.01 in all). When patients were further classified with respect to underlying heart disease whether they had SSS or AVB, all measurements of the LAA (EF, V(E) and V(F)) in both subgroup of patients with SSS and AVB were found significantly lower in those with ventricular pacing than in those with physiologic pacing (Tables 3 and 4). This decrease, especially in LAA flow, was much greater in those with SSS (Mean V(E) and V(F) <20 cm/s). In a patient paced with VVI for SSS, a thrombus was detected within the LAA cavity. In conclusion, these results suggest that the pacing modality appeared to influence the LAA functions in paced patients. Patients with asynchronous ventricular pacing modes had a significantly higher incidence of depressed LAA functions than did patients with physiological pacing, especially more marked in patients with sick sinus syndrome. This may be a factor responsible for increased risk of thrombus formation and thromboembolic events in this patient population.  相似文献   

20.
In DDD pacing, the left-ventricular electromechanical latency period defines the duration between premature ventricular stimulation and the prematurely ending left-atrial contribution to left-ventricular filling. It has to be considered in diastolic AV delay optimization. Individual duration of this parameter seemed to reflect the ventricular function. Therefore, we compared the left-ventricular electromechanical latency period due to right ventricular stimulus with the documented ejection fraction of two groups, 33 congestive heart failure patients carrying biventricular systems and 13 right ventricular paced bradycardia patients. A mean latency period of 168+/-26 ms was found in the heart failure patients (ejection fraction: 25+/-5%) which was significantly longer (p=0.0039) compared to the bradycardia patients (ejection fraction: 51+/-12%) with a mean latency of 119+/-13 ms. Thus, an increasing latency period during right ventricular DDD pacing therapy indicates decreasing ejection fraction. A cut-off interval of 135 ms allowed the discrimination of 93% of our patients as having an individual ejection fraction of either up to 35% or above. Thus, the left ventricular electromechanical latency period can be used as an additional parameter indicating the necessity to upgrade from right to biventricular DDD pacing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号