首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Background: Patients with paroxysmal atrial fibrillation (AF) experience impaired quality of life (QoL) and psychological distress. Catheter ablation of AF can markedly improve QoL. However, the effect of catheter ablation of AF on psychological status is unknown. Hypothesis: Depression, anxiety, and QoL improve after catheter ablation in patients with paroxysmal AF. Methods: A total of 166 consecutive patients with symptomatic paroxysmal AF were examined. Eighty‐two patients (55 men, mean age 55.9 ± 6.1 y) underwent catheter ablation and 84 patients (58 men, mean age 57.2 ± 5.4 years) received antiarrhythmic drug (AAD) therapy. The Self‐Rating Depression Scale, Self‐Rating Anxiety Scale, and Medical Outcomes Survey 36‐item Short‐Form questionnaires were completed by these patients at baseline, and at 3, 6, 9, and 12 months of follow‐up. Results in the ablation group were compared with those of the AAD group. Results: In the ablation group, 42.7% of patients showed symptoms of depression and 37.8% showed symptoms of anxiety, which were similar to those in the AAD group. Both groups similarly displayed reduced physical and mental QoL. Catheter ablation was effective in reducing symptoms of depression and anxiety and improving QoL, and it was superior to AAD therapy (all P < 0.001). Multiple regression analysis demonstrated that catheter ablation, no AF recurrence, avoidance of warfarin use, higher baseline depression and anxiety scores, and lower baseline QoL scores contributed to improvement of depression, anxiety, and QoL, respectively. Conclusions: Catheter ablation is more effective for improving depression, anxiety, and QoL in patients with paroxysmal AF compared with AAD therapy. Clin. Cardiol. 2012 doi: 10.1002/clc.22039 This work was supported by grants from the National Science Foundation Council of China (No. 30971239 and No. 81070147) and the Beijing Natural Science Foundation (No. 7101004). The authors have no other funding, financial relationships, or conflicts of interest to disclose.  相似文献   

2.
Atrial Substrate Properties in Chronic AF Patients with LASEC. Background: The atrial substrate in chronic atrial fibrillation (AF) patients with a left atrial spontaneous echo contrast (LASEC) has not been previously reported. The aim of this study was to investigate the atrial substrate properties and long‐term follow‐up results in the patients who received catheter ablation of chronic AF. Methods: Of 36 consecutive patients with chronic AF who received a stepwise ablation approach, 18 patients with an LASEC (group I) were compared with 18 age‐gender‐left atrial volume matched patients without an LASEC (group II). The atrial substrate properties including the weighted peak‐to‐peak voltage, total activation time during sinus rhythm (SR), dominant frequency (DF), and complex fractionated electrograms (CFEs) during AF in the bi‐atria were evaluated. Result: The left atrial weighted bipolar peak‐to‐peak voltage (1.0 ± 0.6 vs 1.6 ± 0.7 mV, P = 0.04), total activation time (119 ± 20 vs 103 ± 13 ms, P < 0.001) and DF (7.3 ± 1.3 vs 6.6 ± 0.7 Hz, P < 0.001) differed between group I and group II, respectively. Those parameters did not differ in the right atrium. The bi‐atrial CFEs (left atrium: 89 ± 24 vs 92 ± 25, P = 0.8; right atrium: 92 ± 25 vs 102 ± 3, P = 0.9) did not differ between group I and group II, respectively. After a mean follow‐up of 30 ± 13 month, there were significant differences in the antiarrhythmic drugs (1.1 ± 0.3 vs 0.7 ± 0.5, P = 0.02) needed after ablation, and recurrence as persistent AF (92% vs 50%, P = 0.03) between group I and group II, respectively. After multiple procedures, there were more group II patients that remained in SR, when compared with group I (78% vs 44%, P = 0.04). Conclusion: There was a poorer atrial substrate, lesser SR maintenance after catheter ablation and need for more antiarrhythmic drugs in the chronic AF patients with an LASEC when compared with those without an LASEC. (J Cardiovasc Electrophysiol, Vol. pp. 1‐8)  相似文献   

3.
Impact of COPD on Atrial Fibrillation Ablation. Background : Chronic obstructive pulmonary disease (COPD) is a risk factor for atrial fibrillation (AF). The aim of this study was to investigate the impact of COPD on outcomes of catheter ablation in patients with AF in terms of recurrence and quality of life (QoL). Methods : In this prospective study, 550 consecutive patients with symptomatic, medication‐refractory AF underwent first catheter ablation. Patients were classified into those with COPD (group 1, n = 54) and those without COPD (group 2, n = 496). Patients were followed up for atrial tachyarrhythmia (ATa) recurrence for at least 24 months. The Medical Outcomes Study SF‐36 Health Survey was used to assess QoL at baseline and 24 months after ablation. Results : After a single ablation, 24 patients in group 1 (44.4%) and 142 in group 2 (28.6%) had ATa recurrence during a mean follow‐up of 31.4 ± 4.8 months (P = 0.016). The second ablation was performed in 19 patients (35.2%) from group 1 and in 109 patients (22.0%) from group 2 (P = 0.029). Multivariate logistic analysis showed that nonparoxysmal AF (P = 0.013, OR = 1.767, 95% CI: 1.129–2.765) as well as the presence of COPD (P = 0.029, OR = 1.951, 95% CI: 1.070–3.557) was the independent predictor for higher ATa recurrence. Moreover, patients in group 1 had significantly lower baseline scores on all SF‐36 Health Survey subscales. At 24‐month follow‐up, both mental component summary and physical component summary scores improved markedly in group 1 and 2. Conclusions : Although the presence of COPD predicted higher recurrence after single‐catheter ablation in AF patients, significant improvements in QoL were observed in the postablation COPD population. (J Cardiovasc Electrophysiol, Vol. 24, pp. 148‐154, February 2013)  相似文献   

4.
Predict AF. Objective: Since predictors of recurrence of atrial fibrillation (AF) after ablation procedures are poorly defined, this prospective study was conducted to assess the value of left atrial (LA) deformation imaging with two‐dimensional speckle‐tracking (2D‐ST) to predict AF recurrences after successful ablation procedures. Methods and results: One hundred and three consecutive patients (age 58.1 ± 16.6 years, 72.8% male) with AF (76 paroxysmal, 27 persistent) and 30 matched controls underwent transthoracic echocardiography and 2D‐ST‐LA‐deformation analysis with assessment of LA‐radial and LA‐longitudinal strain (Sr, Sl), and velocities derived from the apical 4‐ and 2‐chamber views (4CV, 2CV). AF recurrence was assessed during 6 months of follow‐up. For determination of AF‐related LA changes, AF patients were compared to controls and patients with AF recurrences after ablation procedures (n = 30, 29.1%) were compared with patients who maintained sinus rhythm (n = 73, 70.9%). Atrial deformation capabilities were significantly reduced (P < 0.0005) in patients with AF (4CVSl 17.8 ± 13.5%; 4CVSr 22.3 ± 14.9%; 4CV‐velocities 2.53 ± 0.97 seconds) when compared with controls (4CVSl 31.3 ± 12.4%; 4CVSr 30.3 ± 9.1%; 4CV‐velocities 3.48 ± 1.01 cm/s). Independent predictors for AF recurrence after ablation procedures were 2CV‐LA‐global‐strain (Sr, P = 0.03; Sl, P = 0.003), 4CV‐LA‐gobal‐strain (Sr, P = 0.03; Sl, P = 0.02), and regional LA‐septal wall‐Sl (P = 0.008). LA‐global‐strain parameters were superior to regional LA function analysis for the prediction of AF recurrences, with cutoff values (cov), hazard ratios (HR), positive and negative predictive values (PPV, NPV) were: 4CVSl cov, 10.79% (HR 27.8, P < 0.0005; PPV 78.8%, NPV 93.9%), 4CVSr cov, ?16.65% (HR 24.8, P < 0.0005; PPV 69.4%, NPV 96.6%), 2CVSl cov, 12.31% (HR 22.7, P < 0.0005; PPV 75.8%, NPV 95.3%), and 2CVSr cov, ?14.9% (HR 12.9, P < 0.0005; PPV 64.3%, NPV 93.2%). Conclusion: Compared with controls, AF itself seems to decrease LA deformation capabilities. The assessment of global LA strain with 2D‐ST identifies patients with high risk for AF recurrence after ablation procedures. This imaging technique may help to improve therapeutic guiding for patients with AF. (J Cardiovasc Electrophysiol, Vol. 23 p. 247‐255, March 2012.)  相似文献   

5.
Background: Evaluation of ventricular rate control in atrial fibrillation (AF) can be difficult, and the presence of an AF‐induced ventricular cardiomyopathy due to intermittent poor rate control or other causes may be underestimated. The outcome with AF ablation in patients with a decreased left ventricular ejection fraction (LVEF) may provide insight into this important clinical issue. Objective: To determine the effect of pulmonary vein isolation on LVEF in patients with AF and decreased LVEF (≤50%). Methods: Ablation consisted of proximal isolation of arrhythmogenic pulmonary veins (PVs) and elimination of non‐PV triggers. LVEF was determined within 24 hours after ablation and again at up to 6 months follow‐up. Transtelephonic monitoring was performed routinely for 2–3 weeks prior to ablation, at 6 weeks, and 6 months post and with symptoms following ablation. AF control was defined as freedom from AF or marked (>90%) reduction in AF burden on or off previously ineffective antiarrhythmic medication. Results: AF ablation was performed in 366 patients and 67 (18%) patients had decreased LV function with a mean LVEF of 42 ± 9%. An average of 3.4 ± 0.9 PVs were isolated. AF control in the depressed LVEF group compared favorably with the normal EF group (86% vs. 87% P = NS), although more redo procedures were required (1.6 ± 0.8 vs 1.3 ± 0.6 procedures; P ≤ 0.05). Only 15 of 67 patients (22%) with decreased LVEF had shown tachycardia (>100 bpm) on repeated preablation ECG recordings during AF. In the decreased LVEF group, the LVEF increased from 42 ± 9% to 56 ± 8% (P < 0.001) after ablation. Conclusions: Patients with AF and decreased LVEF undergoing AF ablation have similar success to patients with normal LVEF and have improvement in LVEF after ablation. These results suggest the presence of a reversible AF‐induced ventricular cardiomyopathy in many patients with AF and depressed LV function. The presence of under‐recognized and reversible cardiomyopathy even when tachycardia is not persistent is important to recognize.  相似文献   

6.
Long‐Term Outcome of NPV AF Ablation . Introduction: Data regarding the long‐term outcome of catheter ablation in patients with nonpulmonary vein (NPV) ectopy initiating atrial fibrillation (AF) are limited. We aimed to evaluate the long‐term result of patients with AF who had NPV triggers and underwent catheter ablation. Methods and Results: The study included 660 consecutive patients (age 54 ± 11 years old, 477 males) who had undergone catheter ablation for AF. Group 1 consisted of 132 patients with AF initiating from the NPV, and group 2 consisted of 528 patients with AF initiating from pulmonary vein (PV) triggers only. Patients from Group 1 were younger than those from Group 2 (51 ± 12 years old vs 54 ± 11 years old, P = 0.001) and were more likely to be females (34.4% vs 25.8%, P = 0.049). The incidences of nonparoxysmal AF (36.4% vs 16.3%, P < 0.001) and right atrial (RA) enlargement (31.3% vs 19%, P = 0.004) were higher, and the biatrial substrates were worse in Group 1 than those in Group 2 (left atrial voltage 1.5 ± 0.7 mV vs 1.9 ± 0.7 mV, P < 0.001, RA voltage 1.6 ± 0.5 mV vs 1.8 ± 0.6 mV, P = 0.014). During a follow‐up period of 46 ± 23 months, there was a higher AF recurrence rate in Group 1 than in Group 2 (57.6% vs 38.8%, P < 0.001). The independent predictors of AF recurrence were NPV trigger (P < 0.001, HR 2, 95% CI 1.4–2.85), nonparoxysmal AF (P = 0.021, HR 1.55, 95% CI 1.07–2.24), larger left atrial diameter (P = 0.002, HR 1.04, 95% CI 1.02–1.07) and worse left atrial substrate (P = 0.028, HR 1.3, 95% CI 1.03–1.64). Conclusion: Compared to AF originating from the PV alone, AF originating from the NPV ectopy showed a worse outcome. (J Cardiovasc Electrophysiol, Vol. 24, pp. 250‐258, March 2013)  相似文献   

7.
Early Recurrence After AF Ablation. Background: Atrial tachycardia (AT) commonly recurs within 3 months after radiofrequency catheter ablation for atrial fibrillation (AF). However, it remains unclear whether early recurrence of atrial tachycardia (ERAT) predicts late recurrence of AF or AT. Methods: Of 352 consecutive patients who underwent circumferential pulmonary vein isolation with or without linear ablation(s) for AF, 56 patients (15.9%) with ERAT were identified by retrospective analysis. ERAT was defined as early relapse of AT within a 3‐month blanking period after ablation. Results: During 21.7 ± 12.5 months, the rate of late recurrence was higher in patients with ERAT (41.1%) compared with those without ERAT (11.8%, P < 0.001). In a multivariable model, positive inducibility of AF or AT immediately after ablation (65.2% vs 36.4%, P = 0.046; odd ratio, 3.9; 95% confidence interval, 1.0–14.6) and the number of patients who underwent cavotricuspid isthmus (CTI) ablation (73.9% vs 42.4%, P = 0.042; odd ratio, 4.5; 95% confidence interval, 1.1–19.5) were significantly related to late recurrence in the ERAT group. The duration of ablation (174.3 ± 62.3 vs 114.7 ± 39.5 minutes, P = 0.046) and the procedure time (329.3 ± 83.4 vs 279.2 ± 79.7 minutes, P = 0.027) were significantly longer in patients with late recurrence than in those without late recurrence following ERAT. Conclusions: The late recurrence rate is higher in the patients with ERAT compared with those without ERAT following AF ablation, and is more often noted in the patients who underwent CTI ablation and had a prolonged procedure time. Furthermore, inducibility of AF or AT immediately after ablation independently predicts late recurrence in patients with ERAT. (J Cardiovasc Electrophysiol, Vol. 21, pp. 1331‐1337, December 2010)  相似文献   

8.
Functional Evaluation of the LA by Dynamic CT. Introduction: Elucidating the functional properties and remodeling process of the entire left atrium (LA) is important not only for offering the mechanistic insight into atrial fibrillation (AF) but also for assessing the effectiveness of catheter ablation. Methods: We included 65 patients with paroxysmal AF and 29 controls. Baseline multidetector computed tomography (MDCT) was acquired in all subjects and a follow‐up MDCT was available in 48 patients after pulmonary vein and LA ablation. The 3‐dimensional images at atrial end‐diastole (ED) and end‐systole (ES) were analyzed. Results: The LA volume (ED: 61.11 ± 15.94 vs 54.12 ± 8.94 mL/m2, P = 0.03; ES: 45.29 ± 17.64 vs 33.38 ± 7.78 mL/m2, P < 0.001) was increased, and ejection fraction (EF) (26.93 ± 13.40 vs 38.09 ± 11.62%, P < 0.001) decreased in AF patients as compared to controls. After ablation, the ES LA volume (44.73 ± 14.93 vs 38.04 ± 11.51 mL/m2, P = 0.04) decreased and the LA EF (25.04 ± 13.13 vs 30.82 ± 7.85%, P = 0.03) increased in patients without any AF recurrence. The wall motion (WM) analysis of the 18 segments of LA revealed increased motional magnitudes of entire LA except for the anterior roof. In contrast, the volume, EF, and WM of LA remained similar in patients with recurrence. Conclusion: Dilated LA with global hypokinesia was noted in AF patients. Improved LA transport function was demonstrated in patients without any recurrence after ablation. However, the anatomic and functional reverse remodeling was not significant in patients with AF recurrence. (J Cardiovasc Electrophysiol, Vol. 21, pp. 270–277, March 2010)  相似文献   

9.
MMP‐2 Predicts the Outcome of AF Ablation. Introduction: Although catheter ablation can effectively eliminate atrial fibrillation (AF), the progression of atrial remodeling increases the risk of recurrence. AF is associated with inflammation and subsequent myocardial fibrosis. We therefore examined the possibility of determining the postablation prognosis of patients with AF using biomarkers of inflammation and collagen turnover. Methods and Results: Subjects were 50 patients who underwent catheter ablation for drug‐resistant AF. High‐sensitivity CRP (hs‐CRP), interleukin (IL)‐6, carboxyl‐terminal telopeptide of collagen type I (ICTP), metalloproteinase (MMP)‐2, tissue inhibitor of MMP‐2 (TIMP‐2), atrial natriuretic peptide (ANP), and brain natriuretic peptide (BNP) were measured before and 2.2 ± 0.8 months after ablation. During the follow‐up period of 14.0 (4.7–20.9) months, AF recurred in 21 of the 50 patients. Recurrence was associated with an MMP‐2 elevation (860.3 ± 120.8 ng/mL vs 687.0 ± 122.5 ng/mL [in patients without recurrence]), ICTP elevation (3.2 ± 1.1 ng/mL vs 2.7 ± 0.6 ng/mL), BNP elevation, greater body mass index, nonparoxysmal AF, and hypertension (P < 0.05 for all). Serum MMP‐2 and nonparoxysmal AF were shown by multivariate analysis to be independent predictors for postablation AF recurrence. Overall, hs‐CRP, IL‐6, ANP, and BNP levels decreased, and MMP‐2, TIMP‐2, and ICTP levels increased 2 months after ablation. Conclusions: Our finding that markers of collagen turnover were elevated in patients who experienced AF recurrence after ablation indicate that these markers might be a useful guide to identify a subgroup of AF patients who require extensive ablation strategies. A 2‐month postablation elevation in collagen turnover markers suggests that the wound healing process persists for that long after ablation. (J Cardiovasc Electrophysiol, Vol. 22, pp. 987‐993, September 2011)  相似文献   

10.
Ablation and Spectral Characteristics of Fibrillation. Background: Complex fractionated atrial electrograms (CFAE) have been considered to be helpful during catheter ablation of atrial fibrillation (AF). The purpose of this study was to analyze the characteristics of CFAEs recorded during sinus rhythm (SR) and AF, and to determine their relationship to perpetuation of AF and clinical outcome. Methods and Results: Antral pulmonary vein isolation (APVI) was performed in 34 consecutive patients (age = 59 ± 10 years) with paroxysmal AF who presented in SR. Time‐ and frequency‐domain characteristics of electrograms recorded from the same sites in the coronary sinus (CS) were analyzed during SR and AF, before and during isoproterenol infusion. There was a modest correlation in fractionation index (FI: change in the direction of depolarization, r = 0.40, P = 0.001) and complexity index (CI: change in the polarity of depolarization, r = 0.41, P = 0.001), but not in the dominant frequency (DF) between SR and AF. There was no relationship between the DF and CI or FI during AF. Isoproterenol was associated with an increase in DF during AF (6.6 ± 0.9 vs 5.1 ± 0.6 Hz, P < 0.001) but had no effect on CI or FI (P = 0.6). A higher CI (58.3 ± 21.0/s vs 38.0 ± 21.0/s, P < 0.01), and FI (123.5 ± 44.8/s vs 75.6 ± 44.6/s, P < 0.01) during AF were associated with a lower likelihood of termination of AF during APVI and a higher probability of recurrent AF after ablation. Ratio of FI during AF to SR was also higher when AF persisted than terminated after APVI (29.7 ± 12.4 vs 19.1 ± 9.7, P = 0.002). However, time‐ or frequency‐domain parameters during SR were not predictive of termination or clinical outcome. Conclusions: Structural and functional properties of the atrial myocardium during AF contribute to electrogram complexity, which may indicate the presence of extra‐PV mechanisms of AF that are not eliminated by APVI. Mapping of complex electrograms in SR is not likely to be sufficient to identify drivers of AF. (J Cardiovasc Electrophysiol, Vol. 22, pp. 851‐857, August 2011)  相似文献   

11.

Introduction

Obesity is a well-known risk factor for atrial fibrillation (AF). We aim to evaluate the effect of baseline obesity on procedural complications, AF recurrence, and symptoms following catheter ablation (CA).

Methods

All consecutive patients undergoing AF ablation (2013–2021) at our center were enrolled in a prospective registry. The study included all consecutive patients with available data on body mass index (BMI). Primary endpoint was AF recurrence based on electrocardiographic documentation. Patients were categorized into five groups according to their baseline BMI. Patients survey at baseline and at follow-up were used to calculate AF symptom severity score (AFSS) as well as AF burden (mean of AF duration score and AF frequency score; scale 0: no AF to 10: continuous and 9 frequencies/durations in between). Patients were scheduled for follow-up visits with 12-lead electrocardiogram at 3, 6, and 12 months after ablation, and every 6 months thereafter.

Results

A total of 5841 patients were included (17% normal weight, 34% overweight, 27% Class I, 13% Class II, and 9% Class III obesity). Major procedural complications were low (1.5%) among all BMI subgroups. At 3 years AF recurrence was the highest in Class III obesity patients (48%) followed by Class II (43%), whereas Class I, normal, and overweight had similar results with lower recurrence (35%). In multivariable analyses, Class III obesity (BMI ≥ 40) was independently associated with increased risk for AF recurrence (hazard ratio, 1.30; confidence interval, 1.06–1.60; p = .01), whereas other groups had similar risk in comparison to normal weight. Baseline AFSS was lowest in normal weight, and highest in Obesity-III, median (interquartile range) 10 (5–16) versus 15 (10–21). In all groups, CA resulted in a significant improvement in their AFSS with a similar magnitude among the groups. At follow-up, AF burden was minimal and did not differ significantly between the groups.

Conclusion

AF ablation is safe with a low complication rate across all BMI groups. Morbid obesity (BMI ≥ 40) was significantly associated with reduced AF ablation success. However, ablation resulted in improvement in QoL including reduction of the AFSS, and AF burden regardless of BMI.  相似文献   

12.
Long‐Term Outcome of SVC AF Ablation. Introduction: Data of the long‐term clinical outcome after superior vena cava (SVC) isolation are limited. We aimed to evaluate the long‐term outcome in patients with atrial fibrillation (AF) who had triggers originating from the SVC and received catheter ablation of AF. Methods and Results: The study consisted of 68 patients (age 56 ± 12 years old, 32 males) who underwent the ablation procedure for drug‐refractory, symptomatic paroxysmal AF originating from the SVC since 1999. Group 1 consisted of 37 patients with AF initiated from the SVC only, and group 2 consisted of 31 patients with both SVC and pulmonary vein (PV) triggers. During a follow‐up period of 88 ± 50 months, the AF recurrence rate was 35.3% after a single procedure. The freedom‐from‐AF rates were 85.3% at 1 year and 73.3% at 5 years. In the baseline study, group 2 had larger left atrium (38 ± 4 mm vs 36 ± 5 mm, P = 0.04), left ventricle (50 ± 5 mm vs 46 ± 5 mm, P = 0.003), and PV diameters. Kaplan–Meier survival analysis showed a higher AF recurrence rate in group 2 compared to that in group 1 (P = 0.012). The independent predictor of an AF recurrence was a larger SVC diameter (P = 0.02, HR 1.4, 95% CI 1.1–1.8). Conclusion: Among the patients with paroxysmal AF originating from the SVC, 73% remained free of AF for 5 years after a single catheter ablation procedure. Superior vena cava isolation without PV isolation is an acceptable therapeutic strategy in those patients with AF originating from the SVC only. The SVC diameter was an independent predictor of AF recurrence. (J Cardiovasc Electrophysiol, Vol. 23, pp. 955‐961, September 2012)  相似文献   

13.
AF Ablation in Octogenarians. Introduction: Radiofrequency catheter ablation (RFCA) is an effective treatment for atrial fibrillation (AF), although studies evaluating the role of RFCA have largely excluded elderly patients. We report the safety and outcomes of RFCA of AF in octogenarians. Methods and Results: From 2008 to 2011, out of 2,754 consecutive patients undergoing RFCA of AF, 103 (3.7%) had ≥80 years (age 85 ± 3 years, 4 with >90 years). Pulmonary vein (PV) antrum isolation was performed in paroxysmal AF. In nonparoxysmal AF, ablation was extended to the entire left atrial posterior wall and to complex fractionated electrograms. Non‐PV triggers were disclosed by isoproterenol challenge at the end of the procedure and targeted for ablation. Octogenarians presented a high rate of non‐PV triggers (84% vs 69%, P = 0.001), especially in patients with paroxysmal AF (62% vs 19%, P < 0.001); non‐PV triggers were most commonly mapped in the coronary sinus (54%), left atrial appendage (32%), interatrial septum and superior vena cava (14%). After a mean follow‐up of 18 ± 6 months, 71 (69%) octogenarians remained free from AF recurrence off antiarrhythmic drugs after a single procedure (vs 71% in patients <80 years, P = 0.65). The success rate reached 87% after 2 procedures. Total periprocedural complication rates also did not differ between the 2 age groups. Conclusions: RFCA of AF is safe and effective in octogenarians. A high rate of non‐PV triggers is present in these patients, and targeting multiple structures other than the pulmonary veins is often necessary to achieve long‐term success. (J Cardiovasc Electrophysiol, Vol. 23, pp. 687‐693, July 2012)  相似文献   

14.
Atrial Substrate Remodeling After Chronic AF Ablation . Background: Multiple remodeling patterns have been observed after catheter ablation of atrial fibrillation (AF). Objective: We aimed to clarify the electrical/structural properties associated with recurrences after ablation of chronic AF. Methods: After a stepwise ablation procedure in 120 consecutive patients with persistent/long‐lasting persistent AF, 36 had a recurrence of AF (Group 1/Group 2: recurrence with paroxysmal/persistent AF, n = 16/20). Results: During the first procedure, the left atrial (LA) bipolar voltage did not differ between the 2 groups, and the LA volume was smaller in Group 1 than in Group 2 and it was the only factor predicting the recurrent types (P = 0.009, OR = 1.04). In the second procedure, the bipolar voltage of the global left atrium increased (1.33 ± 0.11 mV vs 1.76 ± 0.16 mV, P = 0.001) in Group 1 and decreased (1.31 ± 0.14 mV vs 0.90 ± 0.12 mV, P = 0.01) in Group 2, when compared with that of the first procedure. The LA low‐voltage area (<0.5 mV) decreased in Group 1, and increased in Group 2. The LA volume (90 ± 8 cm3 vs 72 ± 8 cm3, P = 0.002) decreased in the second procedure in Group 1. It remained the same in Group 2. The right atrial substrates did not change between the procedures. After a follow‐up of 27 ± 3 months, all patients in Group 1 and 14 patients in Group 2 remained in sinus rhythm (P = 0.02). Conclusion: A better outcome with reverse electrical and structural remodeling occurred after the ablation of chronic AF when the recurrence was paroxysmal AF. Progressive electrical remodeling without any structural remodeling developed in those with a recurrence involving persistent AF. (J Cardiovasc Electrophysiol, Vol. 22, pp. 385‐393)  相似文献   

15.
Cerebral Microthromboembolism After CFAE Ablation . Background: The incidence of cerebral thromboembolism after pulmonary vein isolation (PVI) ranges from 2% to 14%. This study investigated the incidence of cerebral thromboembolism after complex fractionated atrial electrogram (CFAE) ablation with or without PVI. Methods: One hundred consecutive atrial fibrillation (AF) patients (50 paroxysmal and 50 persistent, including 10 longstanding) who underwent CFAE ablation combined with (n = 41, PVI+CFAE group) or without (n = 59, CFAE group) PVI were studied. Coronary angiography (CAG) was conducted with AF ablation in 5 cases in which coronary artery stenosis was suspected on 3D‐computed tomography. PVI was performed before CFAE ablation without circular catheter during AF. After termination of AF, additional ablation was performed to complete PVI with a circular catheter. All patients underwent cerebral magnetic resonance imaging (MRI) including diffusion‐weighted MRI and T2‐weighted MRI the day after ablation. Results: New thromboembolism was detected in 7.0%, and there was no significant difference between the 2 strategies (7.3% in PVI+CFAE group, 6.8% in CFAE group). CHADS2 score (1.6 ± 1.0 vs 0.8 ± 0.9, P < 0.05), left atrial volume (LAV; 83.8 ± 27.1 vs 67.8 ± 21.8, P < 0.05), and left ventricular ejection fraction (LVEF, 53.1 ± 9.2 vs 65.1 ± 9.7, P < 0.01) were significantly different when comparing patients with or without thromboembolism. In multivariate analysis, LVEF (odds ratio [OR], 0.92; 95% confidence interval [CI], 0.84–0.99; P < 0.05) and concomitant CAG (OR 18.82; 95% CI, 1.77–200.00; P < 0.05) were important predictors of new cerebral thromboembolism. Conclusions: The incidence of cerebral microthromboembolism after CFAE ablation was not greater than previous reports in PVI. Cautious management is required during AF ablation, especially in the patients with low LVEF. (J Cardiovasc Electrophysiol, Vol. 23, pp. 567–573, June 2012)  相似文献   

16.
Very Early Recurrence of AF. Introduction: Early restoration of sinus rhythm following ablation of atrial fibrillation (AF) facilitates reverse atrial remodeling and improves the long‐term outcome. The purpose of this study was to determine the predictors and outcome in patients with very early AF recurrences (< 2 days). Methods and Results: Ablation was performed in 339 consecutive AF patients (paroxysmal AF = 262). Biatrial voltage was mapped during sinus rhythm. If recurrent AF occurred within 2 days following the ablation, electrical cardioversion was performed to restore sinus rhythm. Very early recurrences of AF occurred in 39 (15%) patients with paroxysmal AF and 26 (34%) with nonparoxysmal AF. Patients with very early recurrence had a higher incidence of nonparoxysmal AF (40% vs 18.6%, P< 0.001), requirement of electrical cardioversion during procedure, larger left atrial (LA) diameter (43 ± 7 vs 39 ± 6 mm, P< 0.001), lower left ventricular ejection fraction (54 ± 10% vs 59 ± 7, P< 0.001), longer procedural time, and lower LA voltage (1.5 ± 0.7 vs 1.9 ± 0.8 mV, P< 0.001). A multivariate analysis revealed that the independent predictors of a very early recurrence were a longer procedural time and lower LA voltage. During a follow‐up of 13 ± 5 months, a very early recurrence did not predict the long‐term outcome of a single procedure recurrence in the patients with paroxysmal AF, but was associated with a late recurrence in the nonparoxysmal AF patients. Conclusion: Very early recurrence occurred in patients with paroxysmal AF is not associated with long‐term recurrence. Nonparoxysmal AF is an independent predictor of late recurrence of AF in patients with very early recurrence. (J Cardiovasc Electrophysiol, Vol. pp. 1‐6)  相似文献   

17.
Electromechanical Interval and Strokes After Ablations of AF . Introduction: Atrial fibrillation (AF) is associated with increased risk of embolic stroke. Catheter ablation of AF provides an effective therapy for patients with symptomatic and drug‐refractory AF. The aim of this study was to evaluate whether the atrial electromechanical interval is useful in identifying patients at risk of stroke after successful catheter ablation. Methods and Results: A total of 279 AF patients who received catheter ablation and showed no evidence of recurrences were enrolled. Electromechanical interval (PA–PDI) was determined as the time interval from the initiation of P wave deflection to the peak of mitral inflow A wave on pulse wave Doppler imaging. The PA–PDI interval was measured for each patient after the 3‐month blanking period of catheter ablation. The clinical endpoint was the occurrence of ischemic stroke. During the follow‐up of 46.5 ± 17.2 months, 6 patients suffered from ischemic strokes. Patients with strokes had higher CHA2DS2–VASc scores and longer PA–PDI intervals (138.7 ± 12.4 ms vs 161.2 ± 7.7 ms, P value < 0.001) compared to those without strokes. At a cutoff point of 150 ms identified by ROC curve, the positive and negative predictive values of the PA–PDI interval to predict stroke were 86.7% and 100%, respectively. The PA–PDI interval improved the predictive performance of the CHA2DS2–VASc score, and the area under the ROC curve increased from 0.75 to 0.85. Conclusions: Our results suggest that the PA–PDI interval is a useful tool to identify patients with high risk of stroke after successful catheter ablation of AF. (J Cardiovasc Electrophysiol, Vol. 24, pp. 375‐380, April 2013)  相似文献   

18.
Noninducibility by High‐Dose Isoproterenol. Objective: To determine the relative clinical value of noninducibility of atrial fibrillation (AF) by isoproterenol (ISO) and by rapid atrial pacing (RAP) in patients with paroxysmal AF (PAF). Background: AF can be induced by RAP or ISO in >85% of patients with PAF. Methods: ISO was administered in escalating doses of 5, 10, 15, and 20 μg/min in 112 patients (age = 56 ± 13 years) with PAF before radiofrequency catheter ablation. AF was inducible in 97 of 112 patients (87%) at a mean dose of 15 ± 5 μg/min. RAP induced AF in the remaining 14 of 15 patients. Antral pulmonary vein (PV) isolation (APVI) was followed by ablation of complex fractionated atrial electrograms (CFAEs) as necessary to terminate AF and render AF noninducible in response to ISO. Results: AF terminated during APVI in 72 of 111 patients (65%) and after APVI plus ablation of CFAEs in 11 of 111 patients (10%). In the remaining 28 patients (25%), sinus rhythm was restored by transthoracic cardioversion. RAP was performed in the last 61 consecutive patients who were rendered noninducible by ISO. RAP initiated AF in 20 of 61 patients (33%) and atrial flutter in 6 patients (10%). No additional ablation was performed if AF was induced with RAP; however, atrial flutter was targeted. At 12 ± 5 months, 63/75 patients (84%) who were noninducible by ISO and 2 of 8 (25%) who still were reinducible by ISO were free from recurrent AF after a single ablation procedure without antiarrhythmic drugs (P = 0.001). AF recurred in 20 of 36 patients (56%) who required cardioversion for persistent AF after ablation (P < 0.001). Among the 61 patients who also underwent RAP, 12 of 20 (60%) who were, and 31 of 41 (76%) who were not inducible by RAP were free from recurrent AF (P = 0.21). The accuracy of noninducibility as a predictor of clinical outcome was 83% with ISO and 64% by RAP (P = 0.03). Conclusions: The response to isoproterenol after catheter ablation of PAF more accurately predicts clinical outcome than the response to RAP. (J Cardiovasc Electrophysiol, Vol. 21, pp. 13–20, January 2010)  相似文献   

19.
Introduction: It is unclear whether early restoration of sinus rhythm in patients with persistent atrial arrhythmias after catheter ablation of atrial fibrillation (AF) facilitates reverse atrial remodeling and promotes long‐term maintenance of sinus rhythm. The purpose of this study was to determine the relationship between the time to restoration of sinus rhythm after a recurrence of an atrial arrhythmia and long‐term maintenance of sinus rhythm after radiofrequency catheter ablation of AF. Methods and Results: Radiofrequency catheter ablation was performed in 384 consecutive patients (age 60 ± 9 years) for paroxysmal (215 patients) or persistent AF (169 patients). Transthoracic cardioversion was performed in all 93 patients (24%) who presented with a persistent atrial arrhythmia: AF (n = 74) or atrial flutter (n = 19) at a mean of 51 ± 53 days from the recurrence of atrial arrhythmia and 88 ± 72 days from the ablation procedure. At a mean of 16 ± 10 months after the ablation procedure, 25 of 93 patients (27%) who underwent cardioversion were in sinus rhythm without antiarrhythmic therapy. Among the 46 patients who underwent cardioversion at ≤30 days after the recurrence, 23 (50%) were in sinus rhythm without antiarrhythmic therapy. On multivariate analysis of clinical variables, time to cardioversion within 30 days after the onset of atrial arrhythmia was the only independent predictor of maintenance of sinus rhythm in the absence of antiarrhythmic drug therapy after a single ablation procedure (OR 22.5; 95% CI 4.87–103.88, P < 0.001). Conclusion: Freedom from AF/flutter is achieved in approximately 50% of patients who undergo cardioversion within 30 days of a persistent atrial arrhythmia after catheter ablation of AF.  相似文献   

20.
Background: The mechanistic and clinical significance of complex fractionated atrial electrograms (CFAE) in the coronary sinus (CS) has been unclear. Methods and Results: Antral pulmonary vein isolation (APVI) was performed in 77 patients with paroxysmal (32) or persistent AF (45). CS electrograms recorded for 60 seconds before and after APVI were analyzed in the time‐ and frequency‐domains. Dominant frequency (DF), complexity index (CI: change in polarity of depolarization), and fractionation index (FI: change in direction of depolarization slope) were determined. Before APVI, there was no difference in DF, CI, or FI between paroxysmal and persistent AF. APVI resulted in a significant decrease in DF, CI, and FI in all patients. Baseline CI (43 ± 13/s vs 54 ± 14/s, P = 0.03) and FI (64 ± 23/s vs 87 ± 30/s, P = 0.02) were lower in patients with paroxysmal AF who had AF terminated by ablation than who did not. At 10 ± 2 months, 69% of patients with paroxysmal AF and 49% of patients with persistent AF were free from AF after single ablation. Baseline CI was higher among patients with paroxysmal AF who had AF after APVI (56 ± 20/s vs 44 ± 10/s, P = 0.03). In patients with persistent AF, there was a larger decrease in DF after APVI among patients who remained free from AF (13 ± 11% vs 7 ± 9%, P < 0.05). Conclusions: Complexity of CS electrograms may reflect drivers of AF that perpetuate paroxysmal AF after APVI. In persistent AF, the extent to which APVI decreases DF in the CS correlates with efficacy, suggesting that DF identifies patients who may require additional ablation beyond APVI.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号