首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
3.

Purpose

Managing a deficient acetabulum in patients with developmental dysplasia of the hip (DDH) can be challenging. The purpose of the study was to determine the mid-term results of total hip arthroplasty (THA) using a bulk structural autograft for reconstruction of the acetabular roof in patients with DDH.

Methods

Between 1982 and 1999, 112 patients underwent THA with acetabular roof-plasty using a bulk structural autograft for secondary osteoarthritis related to DDH. A total of 106 patients (115 hips) met inclusion criteria and were followed for an average of 11.6 years (seven to 24 years). The mean age was 52.5 years at the index operation. Clinical and radiological evaluations were performed according to the methods of Merle d’Aubigné and Postel, Johnston et al. and DeLee and Charnley.

Results

The overall Merle d’Aubigné hip score significantly improved (3.7 vs 10.4, p < 0.01). The limb length discrepancy decreased from 30 to 6 mm (p < 0.01). The average distance that the hip centre was distalised was 22.3 mm (0–56 mm). However, radiolucent lines were observed in 27 % of patients at final follow-up, and the overall rate of revision for aseptic loosening was 16 %. Further, Kaplan-Meier survivorship curves predicted a rapid increase in the failure rate at 15 years.

Conclusions

The mid-term functional outcome of THA with an acetabular roof-plasty using a bulk autograft is satisfactory; however, the long-term results are questionable.  相似文献   

4.

Purpose

Selection of the correct femoral stem size is crucial in total hip arthroplasty for an uncomplicated implantation and good initial stability. Pre-operative templating has been shown to be a valuable tool in predicting the correct implant size. For short-stem total hip arthroplasty (SHA), which recently is increasingly used, it is unknown if templating can be performed as reliable as conventional total hip arthroplasty (THA).

Methods

A total of 100 hip arthroplasties, 50 with SHA and 50 with THA, were templated by four orthopaedic surgeons each. The surgeons had different levels of professional experience and performed a digital template of the acetabular and femoral component on the pre-operative radiographs. The results were compared with the truly inserted implant size.

Results

For the femoral stems the average percentage of agreement (±1 size) was 89.0 % in SHA and 88.5 % in THA. There was no significant difference among surgeons in the accuracy of templating the correct stem size and no significant difference between templating SHA and THA. For the acetabular component the average percentage of agreement (±1 size) was 75.8 %. However, the more experienced surgeons showed a significant higher accuracy for templating the correct cup size than the less experienced surgeons.

Conclusion

Digital templating of SHA can predict the stem sizes as accurately as conventional THA. Therefore digital templating is also recommendable for SHA, as it helps to predict the implant size prior to surgery and thereby might help to avoid complications.  相似文献   

5.

Background

A dual mobility cup has the theoretic potential to improve stability in primary total hip arthroplasty (THA) and mid-term cohort results are favorable. We hypothesized that use of a new-generation dual mobility cup in revision arthroplasty prevents dislocation in patients with a history of recurrent dislocation of the THA.

Materials and methods

We performed a retrospective cohort study of patients receiving an isolated acetabular revision with a dual mobility cup for recurrent dislocation of the prosthesis with a minimum follow-up of 1 year. Kaplan–Meier survival analyses were performed with dislocation as a primary endpoint and re-revision for any reason as a secondary endpoint.

Results

Forty-nine consecutive patients (50 hips) were included; none of the patients was lost to follow-up. The median follow-up was 29 months (range 12–66 months). Two patients died from unrelated causes. Survival after 56 months was 100 % based on dislocation and 93 % (95 % CI 79–98 %) based on re-revision for any reason. Radiologic analysis revealed no osteolysis or radiolucent lines around the acetabular component during the follow-up period.

Conclusion

The dual mobility cup is an efficient solution for instability of THA with a favorable implant survival at 56 months.

Level of evidence

Level 4, retrospective case series.  相似文献   

6.

Purpose

Hip replacement is the most common treatment for displaced femoral neck fractures in the elderly, and minimally invasive surgery is popular in the field of orthopaedic surgery. This study evaluated the outcome of monopolar hemiarthroplasty by the direct anterior approach over a postoperative period up to 2.5 years.

Methods

A total of 86 patients with displaced femoral neck fractures were included (mean age of 86.5 years). Surviving patients were reviewed three months (retrospectively) and one to 2.5 years (prospectively) after surgery. One-year mortality was 36 %.

Results

For all stems, implant positioning with respect to stem alignment, restoration of leg length and femoral offset was correct. Acetabular protrusion was observed in 55 % of the patients one to 2.5 years postoperatively. Subsidence and intraoperative periprosthetic fractures occurred in three patients (3 %) each. All revision stems for postoperative periprosthetic fractures could be implanted using the initial surgical technique without extension of the previous approach. The mean Harris hip score was 85 points at the one to 2.5-year follow-up; 85 % of the patients were satisfied with their hip and 57 % returned to their preoperative level of mobility.

Conclusion

Based on these findings, hemiarthroplasty for hip fractures can be performed safely and effectively via the direct anterior approach with good functional outcome and high patient satisfaction.  相似文献   

7.
8.

Purpose

Mid- and long-term follow-up of Charnley total hip arthroplasty (THA) demonstrated good functional results with 85 % survivorship at 25-year follow-up. However, dislocation still remains an unsolved problem. Dislocation may occur throughout the patient’s and implant’s life. The aim of this study is to answer the question: does a dual mobility cup (DMC) decrease the dislocation risk?

Methods

We report comparative results at ten years of follow-up of two groups of primary cemented Charnley-type THA, one with a standard polyethylene cup (group 1, n = 215) and the other one with a DMC (group 2, n = 105).

Results

In group 1, 26 dislocations (12.9 %) occurred. In group 2 only one dislocation (0.9 %) occurred. This dislocation was successfully reduced by closed reduction, without any recurrence. This difference was statistically significant (p = 0.0018). In group 1, the reason for revision was recurrent dislocation in 21 cases. Five patients were revised for other reasons. The global revision rate was 12.9 %. In group 2, two patients needed revision surgery for aseptic loosening. The global revision rate was 2.1 %. This difference was statistically significant (p = 0.054). The goal was reached for the patients of group 2 who had more risks factors for dislocation (age, aetiology, American Society of Anesthesiologists and Devane scores) than those of group 1.

Conclusions

When using a DMC, we observed a low rate of dislocation in primary THA (0.9 %). This surgical choice seems to be a safe and effective technique in Charnley-type THA, especially in a high-risk population.  相似文献   

9.

Background

Total hip arthroplasty (THA) continues to be one of the most successful surgical procedures in the medical field. However, over the last two decades, the use of modularity and alternative bearings in THA has become routine. Given the known problems associated with hard-on-hard bearing couples, including taper failures with more modular stem designs, local and systemic effects from metal-on-metal bearings, and fractures with ceramic-on-ceramic bearings, it is not known whether in aggregate the survivorship of these implants is better or worse than the metal-on-polyethylene bearings that they sought to replace.

Questions/purposes

Have alternative bearings (metal-on-metal and ceramic-on-ceramic) and implant modularity decreased revision rates of primary THAs?

Methods

In this systematic review of MEDLINE and EMBASE, we used several Boolean search strings for each topic and surveyed national registry data from English-speaking countries. Clinical research (Level IV or higher) with ≥ 5 years of followup was included; retrieval studies and case reports were excluded. We included registry data at ≥ 7 years followup. A total of 32 studies (and five registry reports) on metal-on-metal, 19 studies (and five registry reports) on ceramic-on-ceramic, and 20 studies (and one registry report) on modular stem designs met inclusion criteria and were evaluated in detail. Insufficient data were available on metal-on-ceramic and ceramic-on-metal implants, and monoblock acetabular designs were evaluated in another recent systematic review so these were not evaluated here.

Results

There was no evidence in the literature that alternative bearings (either metal-on-metal or ceramic-on-ceramic) in THA have decreased revision rates. Registry data, however, showed that large head metal-on-metal implants have lower 7- to 10-year survivorship than do standard bearings. In THA, modular exchangeable femoral neck implants had a lower 10-year survival rate in both literature reviews and in registry data compared with combined registry primary THA implant survivorship.

Conclusions

Despite improvements in implant technology, there is no evidence that alternative bearings or modularity have resulted in decreased THA revision rates after 5 years. In fact, both large head metal-on-metal THA and added modularity may well lower survivorship and should only be used in select cases in which the mission cannot be achieved without it. Based on this experience, followup and/or postmarket surveillance studies should have a duration of at least 5 years before introducing new alternative bearings or modularity on a widespread scale.  相似文献   

10.

Background

Hip resurfacing arthroplasty (HRA) is an alternative to traditional total hip replacement (THR) that allows for the preservation of femoral bone. It is a more technically difficult procedure that has led some researchers to report an unsatisfactory learning curve (Berend et al., J Bone Joint Surg Am Suppl 2:89–92, 2011; Mont et al., Clin Orthop Relat Res 465:63–70, 2007).

Purpose

The purpose of this study was to investigate the adoption of HRA at our institution, examining the clinical results, revision rate, and modes of failure. Additionally, a comparison of three different implant systems was performed.

Methods

A retrospective review of a consecutive series of HRA performed at our institution between the years 2004 and 2009 was carried out. A total of 820 HRA with a minimum of 2 years of follow-up were included in the study. The majority of included patients were males (70%), with osteoarthritis (92%). The average age was 49.8 years, and the mean BMI was 27.5 kg/m2.

Results

The average Harris hip score improved from 61 to 96.5 postoperatively. Thirteen revisions (1.6%) were performed for femoral neck fracture, femoral head osteonecrosis, acetabular loosening, metal reactivity/metallosis, and metal allergy. The overall Kaplan–Meier survival curve with revision surgery as an endpoint showed 98.5% survival at 5 years. There were no observable differences in clinical scores or revision rates between the different implant systems.

Conclusions

HRA can be successfully adopted with a low complication rate, given careful patient selection, specialized surgical training, and use of good implant design.  相似文献   

11.

Background

The concept of a dual-mobility hip socket involves the standard femoral head component encased in a larger polyethylene liner, which in turn articulates inside a metal shell implanted in the native acetabulum. The aim of this study was to assess outcomes from using a Serf Novae® Dual Mobility Acetabular cup (Orthodynamics Ltd, Gloucestershire, UK) to address the problem of instability in primary and revision total hip arthroplasty (THA).

Materials and methods

A retrospective review was carried out of all hip arthroplasties performed in a District General Hospital utilising the dual-mobility socket from January 2007 to December 2012. Clinical and radiological outcomes were analysed for 44 hips in 41 patients, comprising 20 primary and 24 revision THA. The average age of the study group was 70.8 years (range 56–84 years) for primary and 76.4 years (range 56–89 years) for revision arthroplasty. Among the primary THA, always performed for hip osteoarthritis or in presence of osteoarthritic changes, the reasons to choose a dual mobility cup were central nervous system problems such as Parkinson’s disease, stroke, dementia (10), hip fracture (5), failed hip fracture fixation (2), severe fixed hip deformity (2) and diffuse peripheral neuropathy (1). The indications for revisions were recurrent dislocation (17), aseptic loosening with abductor deficiency (4), failed hemiarthroplasty with abductor deficiency (2) and neglected dislocation (1).

Results

At a mean follow-up of 22 months (range 6–63 months), none of the hips had any dislocation, instability or infection and no further surgical intervention was required. Radiological assessment showed that one uncemented socket in a revision arthroplasty performed for recurrent dislocation had changed position, but was stable in the new position. The patient did not have complications from this and did not need any surgical intervention.

Conclusions

Even though postoperative hip stability depends on several factors other than design-related ones, our study shows promising early results for reducing the risk of instability in this challenging group of patients undergoing primary and revision hip arthroplasty.

Level of evidence

IV.  相似文献   

12.
13.

Purpose

Displaced femoral neck fractures in healthy elderly patients have traditionally been managed with hemiarthroplasty (HA). Recent data suggest that total hip arthroplasty (THA) may be a better alternative.

Methods

A systematic review of the English literature was conducted. Randomized controlled trials comparing all forms of THA with HA were included. Three authors independently extracted articles and predefined data. Results were pooled using a random effects model.

Results

Eight trials totalling 986 patients were retrieved. After THA 4 % underwent revision surgery versus 7 % after HA. The one-year mortality was equal in both groups: 13 % (THA) versus 15 % (HA). Dislocation rates were 9 % after THA versus 3 % after HA. Equal rates were found for major (25 % in THA versus 24 % in HA) and minor complications (13 % THA versus 14 % HA). The weighted mean of the Harris hip score was 81 points after THA versus 77 after HA. The subdomain pain of the HHS (weighted mean score after THA was 42 versus 39 points for HA), the rate of patients reporting mild to no pain (75 % after THA versus 56 % after HA) and the score of WOMAC (94 points for THA versus 78 for HA) all favored THA. Quality of life measured with the EQ-5D favored THA (0.69 versus 0.57).

Conclusions

Total hip arthroplasty for displaced femoral neck fractures in the fit elderly may lead to higher patient-based outcomes but has higher dislocation rates compared with hemiarthroplasty. Further high-quality randomized clinical trails are needed to provide robust evidence and to definitively answer this clinical question.  相似文献   

14.
15.
Julien Girard MD  PhD 《HSS journal》2012,8(3):245-250

Background

Metal-on-metal bearing with cemented femoral component and cementless acetabular fixation is the current standard in surface replacement arthroplasty (RSA) of the hip. Because of concerns about the long-term survivorship of cemented stems in conventional hip arthroplasty, it seems logical to achieve cementless fixation on the femoral side with RSA.

Questions/Purposes

The goals of this review were to evaluate clinical and radiological data reported from previously published cementless RSA series. In addition, we intend to review author’s preliminary experience with Conserve Plus cementless devices specifically assessing the clinical outcomes, the complications rate, the survivorship, and the metallic ions levels measured in follow-up.

Methods

A references search was done with PubMed using the key words “cementless hip resurfacing”, “cementless hip resurfacing prosthesis”, and “femoral cementless hip resurfacing”. Additionally, the clinical outcomes, the complications rate, the survivorship, and the metallic ions levels were measured in 94 cementless Conserve Plus© devices in 90 patients (68 males and 22 females) with a mean age of 41.1 years (18–59). Mean follow-up was 13.1 months (8–16).

Results

No revision was performed during the observed follow-up. Neither radiological signs of loosening nor neck narrowing >10% were evident. Chromium and cobalt levels in whole blood samples rose respectively from 0.53 μg/l (0.1–1.7) to 1.7 μg/l (0.6–2.9) and from 0.54 μg/l (0.1–1.4) to 1.98 μg/l (0.1–2.8).

Conclusions

Cementless “fit and fill” femoral-side fixation, which seems to be potentially evolved and design-related, should be considered for future hip-resurfacing device generations.  相似文献   

16.

Background

Dual mobility (DM) cups of mobile polyethylene were introduced to prevent total hip arthroplasty (THA) dislocation, but no large series with this design to treat recurrent instability have been reported.

Purpose

Our retrospective investigation ascertained the efficiency of DM cups in correction of recurrent dislocation and assessed any adverse effects.

Methods

One hundred eighty THAs with recurrent instability were revised to DM cups in 180 patients (mean age, 67.4 ± 11.7 years; range, 19 to 92 years). Thirty-one patients (17.2%) underwent at least one earlier THA revision, and 15 (10.3%) incurred non-union of the greater trochanter. Of the initial group in 2009, 145 patients had completed evaluations which included assessment of the Harris Hip Score and a radiographic assessment at a mean follow-up of 7.7 ± 2.2 years (range, 4 to 14 years). The rate of survival was calculated considering any reason for revision as failure.

Results

At follow-up, Harris hip score was 83.9 ± 16.1 (range, 21 to 100). Dislocation of the large articulation occurred in seven hips (4.8%), and only two recurred (1.4%) (one requiring additional revision). In addition, two intra-prosthetic dislocations of the small articulation (1.4%) were observed and needed revision surgery. The large number of earlier surgeries and non-union of the greater trochanter were related to recurrent instability. Two cups (1.4%) showed signs of definite loosening; six (4.1%) presented signs of possible loosening. Twenty-nine hips manifested femoral or acetabular osteolysis (20%), but only three were severe. Eight-year survival rate considering revision for any reason was 92.6% (95% CI, 85.5–96.4%).

Conclusions

This series indicates that DM cups are a viable option to treat recurrent THA instability. Their design provides a low risk of recurrent instability without increasing mechanical complications.  相似文献   

17.

Background

High hip center reconstructions, used in revision and complex primary THAs, rely on pelvic bone stock at least 35 mm above the anatomic teardrop. However, the technique does not restore normal hip biomechanics and controversy exists regarding acetabular implant survival. Previous reports document a wide range of implant positioning above the teardrop. There is no anatomic guidance in the literature regarding the amount of bone stock available for initial implant stability in this area of the ilium.

Questions/purposes

We therefore determined the thickness of the human ilium and related it to acetabulum cup coverage in high hip center reconstructions.

Methods

We sectioned 16 cadaveric hips from the anterior superior iliac spine to the anatomic teardrop in 5-mm increments, then measured the thickness of the ilium for each cross section.

Results

The maximum thickness of 42 ± 9 mm occurred at the dome of the acetabulum 35 ± 3 mm above the teardrop. At a distance of 1 cm above the dome, the ilium was reduced by 24%, to 32 ± 6 mm. At 2 cm above the dome, the ilium thickness was 22 ± 4 mm, a 48% reduction from its maximum.

Conclusion

There are substantial anatomic limitations to high hip reconstructions 2 cm above the acetabular dome.  相似文献   

18.

Purpose

The cementless Bicontact® total hip arthroplasty (THA) system (AESCULAP AG, Tuttlingen, Germany) was introduced in 1986/1987 and has been in successful clinical use in an unaltered form up to today. Although good long-term results with the Bicontact® stem have been published, it is questionable whether the implant provides the criteria for a state-of-the-art stem regarding proximal bone stock preservation. The purpose of the study was to monitor the periprosthetic bone mineral density (BMD) in a prospective two-year follow-up dual-energy X-ray absorptiometry (DEXA) study.

Methods

After power analysis, a consecutive series of 25 patients with unilateral Bicontact® stem implantation was examined clinically and underwent DEXA examinations. Scans of seven regions of interest were taken preoperatively and at one week, six months, and one and two years.

Results

One patient required stem revision due to a deep infection. The Harris Hip Score increased significantly by 44 points. The most significant bone loss was observed in the calcar region (R7) in the first six months (−19.2 %). It recovered in the following 18 months to −8.5 %. The BMD in the greater trochanter dropped significantly after six months and remained stable at this level. BMD exceeded baseline values in distal regions and even more in the lesser trochanter region after two years.

Conclusions

We conclude that the Bicontact® stem provides adequate proximal bone stock preservation. We observed some signs of stress shielding at the tip of the stem, which is inevitable to some degree in THA with cementless straight stems. However, in this prospective DEXA investigation, we showed that proximal off-loading does not occur after THA with the Bicontact® system. Thus, we believe that this stem is still a state-of-the-art implant.  相似文献   