From April, 1984 to April, 1989, 104 heart valve replacements were performed in 103 patients. The atrio-ventricular valves (97 mitral and 7 tricuspid valves) were replace by bioprosthetic valves mounted on the flexible stent made of Elgiloy. They included 91 porcine aortic valves and 13 bovine pericardial valves. Only 74 patients recovered and discharged from the hospital because of high operative mortality of re-replacement and double valve replacement (19 and 30 patients, respectively). These patients were followed-up for 8 to 68 months with a total follow-up period of 297 patient-years. Two patients developed cerebral embolism and two developed bacterial endocarditis. The incidence of the two complications was 0.67%/patient-year. No valve failure occurred. Long-term results of bioprosthetic heart valves mounted on flexible stent were better than those mounted on rigid stent. 相似文献
3.
K A Sawatani K Nakano E Imamura M Endo A Hashimoto H Hayashi H Koyanagi 《Nihon Geka Gakkai zasshi》1988,89(11):1886-1892
One hundred and ninety-four patients underwent valve replacements with the glutaraldehyde-preserved porcine bioprostheses (133 Hancock valves, 39 Angell-Shiley valves, 22 Carpentier-Edwards valves and 3 other valves) from 1974 through 1979. There were 105 women and 89 men, whose age ranged 18 to 62 (mean 38.8) years. One hundred and eighty-two patients had mitral bioprosthetic valve replacement (BVR)s, of which 52 had combined aortic mechanical valve replacements, 8 had aortic BVR's, 3 had tricuspid BVR's and 3 had multi-BVR's. Operative mortality was 10.8%. Only one patient was lost to follow-up. Cumulative duration of follow-up is 1421 patient-years. Linearized rate of anticoagulant related hemorrhage, thromboembolism (TE), prosthetic valve endocarditis (PVE), primary tissue failure (PTF) and valve dysfunction (VD) were 0.07, 1.62, 0.49, 2.74 and 3.66% per patient-year. Actuarial freedom from TE, PVE, PTF and VD were 87.0 +/- 2.7%, 95.6 +/- 1.5%, 65.2 +/- 4.9% and 56.9 +/- 5.6% at 13 years. Actuarial survival rate was 67.4 +/- 4.0% at 13 years. Long term follow-up after valve replacement with porcine bioprosthetic valve confirms low thrombogenicity. But primary tissue failure was the chief cause of valve dysfunction and represent a major problem. At this time, we are going to use porcine bioprosthetic valve in the selected patients, that is in the situations in which anticoagulation is contraindicated. 相似文献
4.
J A Sanchez C C Marboe J S Auteri V Jeevanandum N M Edwards C L Berger E A Rose 《The Annals of thoracic surgery》1991,51(1):30-33
We have investigated whether preformed antibodies against xenoantigens bind to cellular elements remaining on porcine bioprosthetic valves after various methods of preservation. Fresh porcine valves treated with either acetone, 4% formaldehyde, or 0.625% glutaraldehyde, as well as an unfixed valve, were incubated with antiserum against porcine xenoantigens. This serum was prepared using the affinity purification method with porcine lymphocytes as the target. The valves were stained with secondary fluorescein-conjugated antibody against immunoglobulin M or immunoglobulin G and examined under fluorescent microscopy. Intense binding of immunoglobulin M to the endocardium was observed in the unfixed valve as well as in valves fixed in acetone and formaldehyde. Glutaraldehyde fixation eliminated binding of antibody. Binding was not noted within the connective tissue. No binding of antiimmunoglobulin G was noted on the endocardium of any of the sections. Examination of three glutaraldehyde-treated porcine valves explanted from the aortic position after 10 years in situ showed no immunoglobulin deposition. These results demonstrate the elimination of antigenicity to preformed antibodies in the endocardium and connective tissue of glutaraldehyde-preserved porcine valves. The findings may, in part, explain the poor performance of formaldehyde-preserved bioprosthetic xenograft valves in the past and support the use of glutaraldehyde as a preferred agent for preservation of bioprosthetic endovascular materials. 相似文献
5.
R S Hartz E B Fisher B Finkelmeier A DeBoer J H Sanders J M Moran L L Michaelis 《The Journal of thoracic and cardiovascular surgery》1986,91(6):910-917
A total of 589 porcine bioprostheses were implanted in 509 patients from January, 1976, through December, 1983. Of the valves implanted, 390 were Hancock and 199 were Carpentier-Edwards. A total of 1,633 patient-years was accrued, with a mean follow-up of 38 months per patient. Two hundred eight patients had aortic valve replacement, 209 had mitral valve replacement, and 79 had multiple valve replacements, of which 46 were aortic and mitral replacements. The mortality for isolated aortic valve replacement was 5.8%; for isolated mitral replacement, 8.6%, and for all patients, 10.9%. Late mortality was 3.9% per patient-year. The actuarial survival rate at 5 years was 79% for aortic, 68% for mitral, and 76% for aortic-mitral valve replacement. There were 12 thromboembolic events (0.73% per patient-year). Two episodes occurred in patients with an aortic bioprosthesis, nine in patients with a porcine mitral valve, and one in a patient with mitral and tricuspid bioprosthetic valves. The probability of remaining free of thromboembolism at 5 years was 99% for the group having aortic valve replacement, 93% for those having mitral replacement, and 100% for the group having aortic-mitral valve replacements. Thirteen episodes of endocarditis occurred (0.8% per patient-year). Seven of the 13 patients died as a direct result of endocarditis. The probability of remaining free of prosthetic endocarditis at 5 years was 97% for the aortic valve replacement group, 95% for the mitral group, and 97% for the aortic-mitral group. There were 20 instances of xenograft failure (1.2% per patient-year). The probability of remaining free of valve failure at 5 years was 96% for the aortic valve replacement group, 93% for the mitral group, and 93% for the aortic-mitral replacement group. Primary tissue failure of a prosthesis occurred in seven patients, all with Hancock valves (0.43% per patient-year). As yet there has been no primary tissue failure of the Carpentier-Edwards prosthesis. There also appears to be a lower incidence of thromboembolism (Edwards, 0.3% per patient-year; Hancock, 0.8% per patient-year) and endocarditis (Edwards, 0.6% per patient-year; Hancock, 1.0% per patient-year). The low incidence of complications with the porcine bioprosthetic valve, especially the Carpentier-Edwards, encourages us to recommend its continued use, especially in situations in which anticoagulation is contraindicated. 相似文献
6.
Helft G Tabone X Georges JL Lomama E Lepailleur C Le Feuvre C Metzger JP Heulin A Vacheron A 《Journal of cardiac surgery》1999,14(4):252-256
AIM: We report the long-term outcome of aortic and mitral bioprostheses in patients over 65 years of age at the time of implantation. The aim was to determine actuarial patient survival, causes of death, and the rate of documented primary structural deterioration. METHODS: One hundred ten patients > or = 65 years of age (mean, 73.4; range, 65-82) underwent successful bioprosthetic valve replacement (aortic, n = 71; mitral, n = 32; both, n = 7) from 1979 to 1985. The valve was pericardial in 39 cases and porcine in 78. The mean follow-up was 8.5 years (101.9 months-total; 934 patient-years; range, 2 months to 15 years). RESULTS: Actuarial patient survival was 79.6% (71-86) at 5 years and 62.4% (52-71) at 10 years. Forty-four patients died, 21 from valve-related causes and 23 from other causes. Thirteen patients (11.8%) had reoperation for valve-related complications: 10 structural deteriorations, 2 paravalvular leaks, and 1 case of endocarditis. One surgical death occurred (7.7%). Twenty-six percent of the patients were receiving anticoagulants because of atrial fibrillation, and 6.4% developed severe bleeding (2.9% patient-years). CONCLUSIONS: Long-term follow-up of these patients > 65 years of age, undergoing bioprosthetic value replacement surgery revealed a low rate of documented primary structural deterioration (0.95% per patient-year), a low mortality rate on reoperation (7.7%), and a high mortality rate due to non-value-related causes (52.3%). 相似文献
7.
P D Stein J M Riddle S R Kemp M W Lee J W Lewis D J Magilligan 《The Journal of thoracic and cardiovascular surgery》1985,90(1):119-125
Synthesis of a calcium-binding amino acid, gamma-carboxyglutamic acid, is a vitamin K-dependent enzymatic process. Warfarin inhibits gamma-carboxyglutamic acid synthesis and, therefore, might diminish the calcification of porcine bioprosthetic valves. To evaluate this, we studied 40 porcine bioprosthetic valves removed because of spontaneous degeneration; 17 patients were treated with warfarin (prothrombin time greater than or equal to 1.5 control) and 23 were untreated. Gross visualization of calcification corresponded closely to x-ray visualization of calcification in explanted valves. No grossly visible calcification or only a single localized nodule was shown in 11 of 17 valves (65%) in treated patients and in only five of 23 valves (22%) in untreated patients (p less than 0.02). Histologic examination showed no calcium or only fine specks of calcium in nine of 13 valves (69%) among warfarin-treated patients and three of 19 valves (16%) from untreated patients. Warfarin, therefore, administered in usual clinical doses, appeared to diminish calcification in spontaneously degenerated porcine bioprosthetic valves. 相似文献
8.
This report provides retrospective follow-up data on 324 consecutive patients who received a Hancock-I porcine valve in the aortic or the mitral position, or in both positions, between June, 1974, and December, 1976. This analysis included 319 valves (193 mitral, 126 aortic) available for study of the incidence of primary tissue valve failure after 10 to 12.5 years of follow-up. Of the 319 prostheses at risk, 114 instances of primary tissue valve failure occurred. Seventy-three of the failed valves were in the mitral position, and 41 were in the aortic position. The calculated actuarial probability of freedom from primary tissue valve failure was 52 +/- 5% for the mitral and 58 +/- 6% for the aortic prostheses at 12.5 years of follow-up. For patients older than 40 years at the time of operation, the rate of freedom from primary failure was 68 +/- 8% and 55 +/- 6% for aortic and mitral prostheses, respectively, at 12.5 years. Comparison of both actuarial curves disclosed no meaningful difference. However, a tendency toward greater failure rate was observed in the mitral prosthesis group. 相似文献
9.
The long-term survival following valve replacement with Carpentier-Edwards or Hancock bioprostheses was compared between the two valve models and between the two groups totaling 407 patients who were discharged after valve replacement beginning in 1974. The two groups of patients were treated in a nonrandomized fashion. The actuarial survival for 299 patients with Carpentier-Edwards valves was 94 +/- 1.5% (+/- standard error) and 93 +/- 1.7% after 5 and 8 years of follow-up, respectively. Comparable figures for 108 patients undergoing valve replacement with Hancock valves were 89 +/- 3.0% and 83 +/- 3.7%, respectively (p = not significant [NS]). The probability of freedom from death and valve removal after 5 and 8 years of follow-up was 91 +/- 1.8% and 79 +/- 4.6%, respectively, with the Carpentier-Edwards valve and 84 +/- 3.5% and 75 +/- 4.3%, respectively, with the Hancock valve (p = NS). An accelerated rate of attrition for both valves was observed in the mitral position. There were no significant differences in actuarial survival between the two valves in the mitral or the aortic position or in the incidence of major valve-related complications. 相似文献
10.
Relation of calcification to torn leaflets of spontaneously degenerated porcine bioprosthetic valves
P D Stein S R Kemp J M Riddle M W Lee J W Lewis D J Magilligan 《The Annals of thoracic surgery》1985,40(2):175-180
The gross appearance of 54 spontaneously degenerated porcine bioprosthetic valves was evaluated to determine the relation of calcium deposition to cusp disruption. Tears or perforations were shown in 89% (48) of the degenerated valves. The most common site of tears or perforations was near the commissural attachment (60% of all tears). Grossly visible deposits of calcium salts that ruptured to the surface of the cusps or caused changes in the topography were observed in 70% (38) of the 54 valves. Calcification was adjacent to tears or perforations in 56% (27) of the 48 valves with torn cusps. Among the valves that showed calcification, the deposits of calcium salts were adjacent to tears or perforations in 71% (27 of 38). The location of deposits of calcium did not relate to the age or sex of the patient or to the position of the valve, but valves with calcium were inserted longer than valves with no calcium (87 +/- 4 versus 58 +/- 7 months; p less than 0.001). The outflow surfaces showed more calcification than the inflow surfaces, irrespective of whether the valves were in the aortic or mitral position. Among the 38 valves with calcification, 92% (35) showed calcification at the commissural attachments, 53% (20) showed calcification in the body of 1 or more cusps, 11% (4) near the base, and 8% (3) near the free edge. In conclusion, most patients with spontaneous porcine valve degeneration showed calcification. The calcification was associated with tears or perforations of the cusps in 50% of all degenerated valves, in 56% of valves with torn cusps, and in 71% of valves that showed gross calcification. 相似文献
11.
12.
Pettenazzo E Deiwick M Thiene G Molin G Glasmacher B Martignago F Bottio T Reul H Valente M 《The Journal of thoracic and cardiovascular surgery》2001,121(3):500-509
OBJECTIVE: Calcification is the most important cause of structural deterioration of glutaraldehyde-fixed bioprosthetic valves. Devitalization of tissue favors calcium deposits in the shape of apatite crystals. Host factors influence the extent and progression of calcification, but the phenomenon can also occur in vitro in the absence of a viable milieu. Whether calcific deposits obtained in vitro are similar to those found in vivo is unknown. METHODS: Four porcine frame-mounted bioprostheses (St Jude Medical Bioimplant; St Jude Medical, Inc, St Paul, Minn) were tested in vitro by using a pulsatile accelerated calcification testing device at a frequency of 300 cycles per minute at 37 degrees C for 19 x 10(6) cycles with a rapid synthetic calcification solution (final product [calcium x phosphate], 130 mg/dL(2)). Three of the same type of xenografts explanted from human subjects because of calcific failure (time in place, 108 +/- 25.63 mo) served as control grafts. Each sample underwent gross and x-ray examination, histology, transmission and scanning electron microscopy, atomic absorption spectroscopy, electron microprobe analysis, and x-ray powder diffraction methods. RESULTS: All in vitro bioprostheses were heavily calcific, with intrinsic Von Kossa stain-positive deposits and a mean calcium content of 205.285 +/- 64.87 mg/g dry weight. At transmission electron microscopy, nuclei of calcification involved mostly collagen fibers and interfibrillar spaces and, more rarely, cell debris and nuclei. Electron microprobe analysis showed a Ca/P atoms ratio of 4.5:3, a value intermediate between hydroxyapatite and its precursor, octacalciumphosphate. X-ray powder diffraction showed a well-separated and sharp peak, which is typical of hydroxyapatite. Aggregates of plate-like crystals up to 8 microm in size were observed at scanning electron microscopy, with a typical tabular hexagonal shape consistent with apatite. The morphologic and chemical findings in human explants were similar. CONCLUSIONS: Intrinsic calcification of glutaraldehyde-fixed porcine valves was induced in vitro. Electron microprobe analysis and x-ray powder diffraction findings were in keeping with apatite crystallization, such as that occurring in valve xenografts implanted in vivo. The model may be of value to accelerate the screening of anticalcific agents and may reduce the need for animal experiments. 相似文献
13.
K Okamura N Atsumi T Jikuya Y Sakakibara T Tsutsui T Mitsui M Hori 《Nihon Geka Gakkai zasshi》1992,93(6):639-645
Long-term clinical results of aortic valve replacement (AVR) with mechanical heart valves and mitral valve replacement (MVR) with porcine valves were analysed. Sixty-three patients received isolated AVR and 48 received isolated MVR. Sixty-eight patients with MVR including double or triple valve replacement were also added in order to evaluate the primary tissue failure (PTF). The patients with operative deaths were excluded. Survival rate at 11 years in AVR was 68 +/- 10% and 67 +/- 15% in MVR without statistical difference. At 11 years, 76 +/- 8% of the patients in AVR were free from valve-related complications in contrast with the poor result of 34 +/- 31% in MVR (p less than 0.01). Main cause of this poor result in MVR was PTF as indicated in following event free rates; 83 +/- 9% at 7 years, 61 +/- 25% at 10 years and 49 +/- 31% at 13 years. There was no statistical difference between patients of above 50 years and below 49 years in PTF. Valve-related death event free was 93 +/- 5% in AVR and 86 +/- 11% in MVR at 11 years (not significant), however, there was statistical difference in re-operation event free rate as 94 +/- 5% in AVR and 76 +/- 11% in MVR at 11 years (p less than 0.001). These results suggest that the use of porcine valves in mitral position is confined to the selected patients. 相似文献
14.
R. S. Almeida R. K. H. Wyse M. R. de Leval M. J. Elliott J. Stark 《European journal of cardio-thoracic surgery》1989,3(6):488-493
Between 1971 and 1986, 335 patients received various extracardiac valved conduits between one of the heart chambers and the pulmonary arteries. The group of patients who received aortic homograft conduits and survived the operation were analysed in detail. The age varied between 9 days and 18 years (mean 7.1 ± 0.7 years), weight 2.4 kg–63.5 kg (mean 17.8 ± 10.8 kg). The diameter of the conduit used was 10–30 mm (mean 20.8 mm). Multivariate analysis revealed a highly significant model (P < 0.005) which showed that the time interval between harvesting and use of the homograft (P < 0.02) and the earlier date of operation (P < 0.05) were the major risk factors for obstruction. Homografts used within 3 weeks of harvesting had freedom from obstruction of 79% at 8 years; homografts used between 3–6 weeks had freedom from obstruction of only 55% at 8 years. Homografts used alone performed significantly better than those extended with woven Dacron tubes. At 10 years, 93% of homografts used alone were free of obstruction compared to 52% of homografts extended with a Dacron tube. We conclude that aortic homografts used within 3 weeks of harvesting provide a reasonably durable conduit for a period of 12 years. Longer storage, and extension of the homograft with a woven Dacron tube should be avoided. 相似文献
15.
T Kazui M Morikawa K Nakanishi M Tsukamoto T Yamaguchi O Yamada S Komatsu 《[Zasshi] [Journal]. Nihon Kyōbu Geka Gakkai》1990,38(6):1023-1029
Long-term results of mitral valve replacement using glutaraldehyde-treated porcine bioprostheses were evaluated. The subjects were 77 patients with the Hancock valve (Hancock group) and 60 with the Liotta valve (Liotta group) who survived operation. The maximum follow-up was 14 years and 8 years, and the cumulative follow-up was 631 patient-year (p-y) and 301 p-y in the Hancock and Liotta groups. The actuarial survival rate at 8 years was 80.1 +/- 4.6% for the Hancock group and 88.1 +/- 4.2% for the Liotta group, and there was no significant difference in survival rate between the both groups. The actuarial survival rate at 14 years was 74.3 +/- 5.9% for the Hancock group. The valve-related complications in the Hancock and the Liotta groups were as follow; thromboembolism 1.9%/p-y vs 1.3%/p-y, bleeding 0 vs 0.7%/p-y, perivalvular leak 0.3% vs 0, infection 0.3%/p-y vs 0.7%/p-y, primary tissue failure (PTF) 3.3%/p-y and all valve-related complications 5.9%/p-y vs 6.0%/p-y. There was no significant difference in valve-related complications between the both groups. However, the actuarial event free rate of PTF was significantly lower in the Liotta group than the Hancock group between 4 and 7 years after operation (100% vs 88.8 +/- 4.3% in the 4th year p less than 0.01, 87.7 +/- 4.4% vs 73.5 +/- 8.0% in the 7th year, p less than 0.05). Although the both anti-thrombogenicity and anti-inflammation were acceptable in the porcine bioprostheses, this prosthesis is now used only in the selected patients because of the limited long term durability of this valve. 相似文献
16.
The purpose of this study was to (1) evaluate the magnitude and distribution of mechanical stresses on closed leaflets of porcine bioprosthetic valves (PBVs) by using a nonlinear, finite-element model, and (2) determine if a relationship exists between the magnitude of stresses at various sites on the leaflet and the incidence of calcification at those sites. Mechanical stresses were found to be highest near the commissures and lowest at the base of the leaflet. At a pressure of 100 mm Hg applied to the closed valve, the maximal principal normal stress was 160 kPa near the commissures, 140 kPa in the body of the leaflet, 70 kPa at the free margin, and 60 kPa near the base. Similarly, the maximal shear stress, at an applied pressure of 100 mm Hg, was 80 kPa near the commissures, 70 kPa in the body of the leaflet, 50 kPa at the free margin, and 40 kPa near the base. This distribution of mechanical stresses on the PBV leaflet coincided with the incidence of calcification of the various regions of the leaflet. Calcification was found most frequently near the commissures, less frequently in the body of the leaflet and free margin, and least frequently at the base. These observations suggest a possible causative relation between the magnitude of mechanical stresses and the site of calcification of PBV leaflets. 相似文献
17.
Long-term results of bioprosthetic mitral valve replacement: the pericardial perspective 总被引:2,自引:0,他引:2
Pericardial valve bioprostheses were introduced in early 1970s and were widely used in the 1980s. The longterm results with the Ionescu-Shiley valve, the first commercially available pericardial valve, were disappointing because of high rate cusp tears during the first decade after implantation. The enthusiasm for this type of bioprosthetic valve was further hampered by the premature failure of the Hancock pericardial valve. The long-term results of aortic valve replacement with the Carpentier-Edwards pericardial valve, which was introduced in 1981, indicated that that valve was durable and the issue of cusp tears had been resolved by an appropriate design. This knowledge prompted surgeons to revisit the merits of pericardial valves for mitral valve replacement and several other pericardial valves are now commercially available. The largest data on long-term results are with the Carpentier-Edwards pericardial mitral valve. The reported freedom from structure valve failure ranged from 69% to 85% at 10 years in patient population with mean age of 60 to 70 years. Young age is a major determinant of valve failure, which is largely due to calcification. There are also long-term data, albeit more limited on the Sorin Pericarbon and Mitroflow valves used for mitral valve replacement. This paper review the published experience with various pericardial bioprosthetic valves used for mitral valve replacement during the past 3 decades. 相似文献
18.
The presence of mechanical or bioprosthetic valves has traditionally excluded patients from mechanical circulatory support. However, several centers have now developed algorithms for the surgical management of native or prosthetic valve disease in patients requiring left ventricular assist device insertion. We report adverse events associated with bioprosthetic valves in the mitral and tricuspid positions in 2 patients who received long-term mechanical support. We recommend anticoagulation for all patients with prosthetic valves in the mitral or tricuspid position to avoid thromboembolism, inflow conduit occlusion, or valvular incompetence. 相似文献
19.
生物瓣膜失功能原因分析 总被引:1,自引:1,他引:1
目的对植入人体内1年以上损坏的生物瓣膜作损坏原因的临床分析。方法1993年6月至2004年6月,共41例(47只)生物瓣膜失功能病人行再次手术换瓣。两次换瓣间隔时间1~16年,平均(9.7±4.1)年。对失功能生物瓣膜进行标本观察及病理学检测。结果47只带支架生物瓣膜中,瓣架无一损坏,42只瓣膜发生瓣叶撕裂或穿孔,35只有不同程度的钙化现象,且在瓣环表面和瓣脚周围有纤维组织增生,2只瓣膜有赘生物及血栓形成;47只生物瓣膜中损坏较重的瓣膜送病理学检查发现大量吞噬细胞和单核细胞浸润。结论生物瓣膜早期损坏以破损撕裂为主,晚期以钙化和破损撕裂等多种因素的复合病损结果出现。 相似文献
20.
M Grimm E Eybl M Grabenw?ger H Spreitzer W J?ger G Grimm P B?ck M M Müller E Wolner 《Surgery》1992,111(1):74-78
A marked release of glutaraldehyde from commercially available pericardial bioprosthetic heart valve (BHV) material in washing solutions was found by high performance liquid chromatography (up to 1.8 ppm of glutaraldehyde per gram of dry tissue). In vitro endothelial cell proliferation rate was impaired dose-dependently in the presence of increasing glutaraldehyde concentrations of the cultivation medium (r = 0.9; p less than 0.05). Cultivation of endothelial cells was impossible on the surface of commercially available BHV material, but successful and uninhibited when toxic glutaraldehyde ligands of the BHV material were antagonized by treatment with L-glutamic acid. 相似文献