首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Valine and lactate have been recognized as important metabolic markers to diagnose brain abscess by means of MRS. However, in vivo unambiguous detection and quantification is hampered by macromolecular contamination. In this work, MEGA‐PRESS difference editing of valine and lactate is proposed. The method is validated in vitro and applied for quantitative in vivo experiments in one healthy subject and two brain abscess patients. It is demonstrated that with this technique the overlapping lipid signal can be reduced by more than an order of magnitude and thus the robustness of valine and lactate detection in vivo can be enhanced. Quantification of the two abscess MEGA‐PRESS spectra yielded valine/lactate concentration ratios of 0.10 and 0.27. These ratios agreed with the concentration ratios determined from concomitantly acquired short‐TE PRESS data and were in line with literature values. The quantification accuracy of lactate (as measured with Cramér‐Rao lower bounds in LCModel processing) was better for MEGA‐PRESS than for short‐TE PRESS in all acquired in vivo datasets. The Cramér‐Rao lower bounds of valine were only better for MEGA‐PRESS in one of the two abscess cases, while in the other case coediting of isoleucine confounded the quantification in the MEGA‐PRESS analysis. MEGA‐PRESS and short‐TE PRESS should be combined for unambiguous quantification of amino acids in abscess measurements. Simultaneous valine/lactate MEGA‐PRESS editing might benefit the distinction of brain abscesses from tumors, and further categorization of bacteria with reasonable sensitivity and specificity.  相似文献   

2.
The goals of this study were to develop an acquisition protocol and the analysis tools for Meshcher–Garwood point‐resolved spectroscopy (MEGA‐PRESS) in mouse brain at 9.4 T, to allow the in vivo detection of γ‐aminobutyric acid (GABA) and to examine whether isoflurane alters GABA levels in the thalamus during anesthesia. We implemented the MEGA‐PRESS sequence on a Bruker 94/20 system with ParaVision 6.0.1, and magnetic resonance spectra were acquired from nine male wild‐type C57BL/6 J mice at the thalamus. Four individual scans were obtained for each mouse in a 2‐h time course whilst the mouse was anesthetized with isoflurane. We developed an automated analysis program with improved correction for frequency and phase drift compared with the standard creatine (Cr) fitting‐based method and provided automatic quantification. During MEGA‐PRESS acquisition, a single voxel with a size of 5 × 3 × 3 mm3 was placed at the thalamus to evaluate GABA to Cr (GABA/Cr) ratios during anesthesia. Detection and quantitative analysis of thalamic GABA levels were successfully achieved. We noticed a significant decrease in GABA/Cr during the 2‐h anesthesia (by linear regression analysis: slope < 0, p < 0.0001). In summary, our findings demonstrate that MEGA‐PRESS is a feasible technique to measure in vivo GABA levels in the mouse brain at 9.4 T.  相似文献   

3.
Glutamine has multiple roles in brain metabolism and its concentration can be altered in various pathological conditions. An accurate knowledge of its concentration is therefore highly desirable to monitor and study several brain disorders in vivo. However, in recent years, several MRS studies have reported conflicting glutamine concentrations in the human brain. A recent hypothesis for explaining these discrepancies is that a short T2 component of the glutamine signal may impact on its quantification at long echo times. The present study therefore aimed to investigate the impact of acquisition parameters on the quantified glutamine concentration using two different acquisition techniques, SPECIAL at ultra‐short echo time and MEGA‐SPECIAL at moderate echo time. For this purpose, MEGA‐SPECIAL was optimized for the first time for glutamine detection. Based on the very good agreement of the glutamine concentration obtained between the two measurements, it was concluded that no impact of a short T2 component of the glutamine signal was detected. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
To investigate the GABA+ modeling accuracy of MEGA‐PRESS GABA+‐edited MRS data with various spectral quality scenarios, the influence of varying signal‐to‐noise ratio (SNR) and linewidth on the model estimates was quantified. MEGA‐PRESS data from 46 volunteers were averaged to generate a template MEGA‐PRESS spectrum, which was modeled and quantified to generate a GABA+ level ground truth. This spectrum was then manipulated by adding 427 combinations of varying artificial noise levels and line broadening, mimicking variations in GABA+ SNR and B0 homogeneity. GABA+ modeling and quantification was performed with 100 simulated spectra per condition using automated routines in both Gannet 3.0 and Tarquin. The GABA+ estimation error was calculated as the relative deviation to the quantified GABA+ ground truth levels to assess the accuracy of GABA+ modeling. Finally, the accordance between the simulations and different in vivo scenarios was assessed. The GABA+ estimation error was smaller than 5% for all GABA+ SNR values with creatine linewidths lower than 9.7 Hz in Gannet 3.0 or unequal 10.6 Hz in Tarquin. The standard deviation of the GABA+ amplitude over 100 spectra per condition varied between 3.1 and 17% (Gannet 3.0) and between 1 and 11% (Tarquin) over the in vivo relevant GABA+ SNR range between 2.6 and 3.5. GABA+ edited studies might be realized for voxels with low GABA+ SNR at the cost of higher group‐level variance. The accuracy of GABA+ modeling had no relation to commonly used quality metrics. The Tarquin algorithm was found to be more robust against linewidth changes than the fitting algorithm in Gannet.  相似文献   

5.
Lactate levels are measurable by MRS and are related to neural activity. Therefore, it is of interest to accurately measure lactate levels in the basal ganglia networks. If sufficiently stable, lactate measurements may be used to investigate alterations in dopaminergic signalling in the striatum, facilitating the detection and diagnosis of metabolic deficits. The aim of this study is to provide a J‐difference editing MRS technique for the selective editing of lactate only, thus allowing the detection of lactate without contamination of overlapping macromolecules. As a validation procedure, macromolecule nulling was combined with J‐difference editing, and this was compared with J‐difference editing with a new highly selective editing pulse. The use of a high‐field (7T) MR scanner enables the application of editing pulses with very narrow bandwidth, which are selective for lactate. We show that, despite the sensitivity to B0 offsets, the use of a highly selective editing pulse is more efficient for the detection of lactate than the combination of a broad‐band editing pulse with macromolecule nulling. Although the signal‐to‐noise ratio of uncontaminated lactate detection in healthy subjects is relatively low, this article describes the test–retest performance of lactate detection in the striatum when using highly selective J‐difference editing MRS at 7 T. The coefficient of variation, σw and intraclass correlation coefficients for within‐ and between‐subject differences of lactate were determined. Lactate levels in the left and right striatum were determined twice in 10 healthy volunteers. Despite the fact that the test–retest performance of lactate detection is moderate with a coefficient of variation of about 20% for lactate, these values can be used for the design of new studies comparing, for example, patient populations with healthy controls. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
γ‐Aminobutyric acid (GABA) and glutamate (Glu), major neurotransmitters in the brain, are recycled through glutamine (Gln). All three metabolites can be measured by magnetic resonance spectroscopy in vivo, although GABA measurement at 3 T requires an extra editing acquisition, such as Mescher–Garwood point‐resolved spectroscopy (MEGA‐PRESS). In a GABA‐edited MEGA‐PRESS spectrum, Glu and Gln co‐edit with GABA, providing the possibility to measure all three in one acquisition. In this study, we investigated the reliability of the composite Glu + Gln (Glx) peak estimation and the possibility of Glu and Gln separation in GABA‐edited MEGA‐PRESS spectra. The data acquired in vivo were used to develop a quality assessment framework which identified MEGA‐PRESS spectra in which Glu and Gln could be estimated reliably. Phantoms containing Glu, Gln, GABA and N‐acetylaspartate (NAA) at different concentrations were scanned using GABA‐edited MEGA‐PRESS at 3 T. Fifty‐six sets of spectra in five brain regions were acquired from 36 healthy volunteers. Based on the Glu/Gln ratio, data were classified as either within or outside the physiological range. A peak‐by‐peak quality assessment was performed on all data to investigate whether quality metrics can discriminate between these two classes of spectra. The quality metrics were as follows: the GABA signal‐to‐noise ratio, the NAA linewidth and the Glx Cramer–Rao lower bound (CRLB). The Glu and Gln concentrations were estimated with precision across all phantoms with a linear relationship between the measured and true concentrations: R1 = 0.95 for Glu and R1 = 0.91 for Gln. A quality assessment framework was set based on the criteria necessary for a good GABA‐edited MEGA‐PRESS spectrum. Simultaneous criteria of NAA linewidth <8 Hz and Glx CRLB <16% were defined as optimum features for reliable Glu and Gln quantification. Glu and Gln can be reliably quantified from GABA‐edited MEGA‐PRESS acquisitions. However, this reliability should be controlled using the quality assessment methods suggested in this work.  相似文献   

7.
Proton point‐resolved spectroscopy (PRESS) localization has been combined with distortionless enhanced polarization transfer (DEPT) in multinuclear MRS to overcome the signal contamination problem in image‐selected in vivo spectroscopy (ISIS)‐combined DEPT, especially for lipid detection. However, homonuclear proton scalar couplings reduce the DEPT enhancement by modifying the spin coherence distribution under J modulation during proton PRESS localization. Herein, a J‐refocused proton PRESS‐localized DEPT sequence is presented to obtain simultaneously enhanced and localized signals from a large number of metabolites by in vivo 13C MRS. The suppression of J modulation during PRESS and the substantial recovery of signal enhancement by J‐refocused PRESS‐localized DEPT were demonstrated theoretically by product operator formalism, numerically by the spin density matrix simulations for different scalar coupling conditions, and experimentally with a glutamate phantom at various TEs, as well as a colza oil phantom. The application of the sequence for localized detection of saturated and unsaturated fatty acids in the calf bone marrow and skeletal muscle of healthy subjects yielded high signal enhancements simultaneously obtained for all components. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
Lactate and β‐hydroxybutyrate are important MRS‐visible biomarkers for the energy metabolism of the human brain. A major obstacle for their unambiguous detection and quantification in vivo is their inherently low concentration and spectral overlap with resonances from lipids and macromolecules. In this work, we demonstrate the improved detectability of lactate and β‐hydroxybutyrate with MEGA‐sLASER compared to MEGA‐PRESS at the clinical field strength of 3 T. The method is validated by numerical simulations, in vitro measurements and in vivo experiments on healthy subjects. It is demonstrated that MEGA‐sLASER offers an SNR increase of approximately 70% for lactate and β‐hydroxybutyrate detection compared to MEGA‐PRESS in various brain regions. This increased SNR translates into reduced Cramér‐Rao lower bounds for quantification and enables a more robust detection of subtle changes in the (brain) energy metabolism. The sensitivity of the method for detection of β‐hydroxybutyrate concentration changes is demonstrated through measurements before and during a ketogenic diet while the sensitivity for detection of lactate concentration changes is shown by measurements before and after an intensive anaerobic exercise.  相似文献   

9.
The reproducibility of gamma‐aminobutyric acid (GABA) quantification results, obtained with MRSI, was determined on a 3 T MR scanner in healthy adults. In this study, a spiral‐encoded, GABA‐edited, MEGA‐LASER MRSI sequence with real‐time motion–scanner‐instability corrections was applied for robust 3D mapping of neurotransmitters in the brain. In particular, the GABA+ (i.e. GABA plus macromolecule contamination) and Glx (i.e. glutamate plus glutamine contamination) signal was measured. This sequence enables 3D‐MRSI with about 3 cm3 nominal resolution in about 20 min. Since reliable quantification of GABA is challenging, the spatial distribution of the inter‐subject and intra‐subject variability of GABA+ and Glx levels was studied via test–retest assessment in 14 healthy volunteers (seven men–seven women). For both inter‐subject and intra‐subject repeated measurement sessions a low coefficient of variation (CV) and a high intraclass correlation coefficient (ICC) were found for GABA+ and Glx ratios across all evaluated voxels (intra?/inter‐subject: GABA+ ratios, CV ~ 8%–ICC > 0.75; Glx ratios, CV ~ 6%–ICC > 0.70). The same was found in selected brain regions for Glx ratios versus GABA+ ratios (CV varied from about 5% versus about 8% in occipital and parietal regions, to about 8% versus about 10% in the frontal area, thalamus, and basal ganglia). These results provide evidence that 3D mapping of GABA+ and Glx using the described methodology provides high reproducibility for application in clinical and neuroscientific studies.  相似文献   

10.
Abnormalities in brain γ‐aminobutyric acid (GABA) have been implicated in various neuropsychiatric and neurological disorders. However, in vivo GABA detection by 1H MRS presents significant challenges arising from the low brain concentration, overlap by much stronger resonances and contamination by mobile macromolecule (MM) signals. This study addresses these impediments to reliable brain GABA detection with the J‐editing difference technique on a 3‐T MR system in healthy human subjects by: (i) assessing the sensitivity gains attainable with an eight‐channel phased‐array head coil; (ii) determining the magnitude and anatomic variation of the contamination of GABA by MM; and (iii) estimating the test–retest reliability of the measurement of GABA with this method. Sensitivity gains and test–retest reliability were examined in the dorsolateral prefrontal cortex (DLPFC), whereas MM levels were compared across three cortical regions: DLPFC, the medial prefrontal cortex (MPFC) and the occipital cortex (OCC). A three‐fold higher GABA detection sensitivity was attained with the eight‐channel head coil compared with the standard single‐channel head coil in DLPFC. Despite significant anatomical variation in GABA + MM and MM across the three brain regions (p < 0.05), the contribution of MM to GABA + MM was relatively stable across the three voxels, ranging from 41% to 49%, a non‐significant regional variation (p = 0.58). The test–retest reliability of GABA measurement, expressed as either the ratio to voxel tissue water (W) or to total creatine, was found to be very high for both the single‐channel coil and the eight‐channel phased‐array coil. For the eight‐channel coil, for example, Pearson's correlation coefficient of test vs. retest for GABA/W was 0.98 (R2 = 0.96, p = 0.0007), the percentage coefficient of variation (CV) was 1.25% and the intraclass correlation coefficient (ICC) was 0.98. Similar reliability was also found for the co‐edited resonance of combined glutamate and glutamine (Glx) for both coils. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
It is generally accepted that the amount and distribution of adipose tissue (AT) in the human body play an important role in the pathogenesis of metabolic diseases. In addition, metabolic effects of released saturated fatty acids (FAs) in blood are known to be more critical than those of unsaturated FAs. However, little is known about the variability in unsaturation of FAs in various AT compartments. The aim of this prospective study was the assessment of mono‐ and polyunsaturated FAs in various AT compartments by localized 1H‐MRS in order to obtain insight into the intra‐ and interindividual variability. Associations of FA unsaturation with intrahepatic lipids (IHLs), insulin sensitivity and related AT volumes were analyzed. Fifty healthy Caucasians (36 male, 14 female) participated in this study. Spectroscopic examinations were performed in subcutaneous adipose tissue in the neck (SCATneck), abdominal deep subcutaneous adipose tissue (DSCAT), abdominal superficial subcutaneous adipose tissue (SSCAT), visceral adipose tissue (VAT), tibial bone marrow (BM) and subcutaneous adipose tissue of the lower leg (SCATcalf) at 3 T. Unsaturated index (UI) was calculated by the ratio of olefinic and methyl resonances, polyunsaturated index (PUI) by the ratio of diallylic and methyl resonances. Volumes of AT compartments (by T1‐weighted MRI) and IHL (single‐voxel STEAM) were assessed at 1.5 T, insulin sensitivity by an oral glucose tolerance test. UI was highest for SCATcalf (0.622) and lowest for BM (0.527). Highest PUI was observed for SSCAT (0.108), lowest for BM (0.093). Significant intraindividual differences between UIs—but not PUIs—are present for most compartments. There is a non‐significant trend for higher UI in males but otherwise no correlation to anthropometric data (age, BMI). A significant negative correlation between UI and AT volume was observed for VAT but for none of the other compartments. Neither UIs nor PUIs show a relation with IHL; insulin sensitivity is significantly correlated to UI in BM (p < 0.01). Unsaturation indices in several distinct AT compartments are location dependent. Our cohort showed only moderate gender‐related differences, with a trend towards less unsaturated FAs (mainly PUI) in females. In BM, insulin resistant subjects are characterized by a higher UI compared with the insulin sensitive ones. Further studies in larger cohorts are necessary to gain further insight into unsaturation of AT.  相似文献   

12.
The glycerol methylene proton resonances (4–4.5 parts per million, ppm), which arise from the triglyceride backbone, are relevant to fat composition assessment and can be measured with proton MRS. The purpose of the presented work is to determine long TE (echo time) point resolved spectroscopy (PRESS) and stimulated echo acquisition mode (STEAM) values at 3 T to resolve the glycerol resonances from that of overlapping water. The response of the glycerol methylene protons of nine edible oils as a function of PRESS and STEAM TE (mixing time, TM = 20 ms) was investigated. In addition, high resolution NMR spectra of the oils were acquired at 16.5 T. Long TE values where J‐coupling losses were lowest were selected, namely a TE of 180 ms for PRESS (first echo time 17 ms) and a TE of 100 ms for STEAM (mixing time 20 ms). Oil olefinic (≈5.4 ppm) to glycerol ratios were calculated from the long TE spectra and correlated with 16.5 T ratios. The two techniques yielded olefinic/glycerol ratios that correlated with 16.5 T ratios (R2 = 0.79 for PRESS and 0.90 for STEAM). The efficacy of the sequences in resolving the glycerol resonance from that of water was verified in vivo on tibial bone marrow of four healthy volunteers. In addition, the potential for using the glycerol methylene signal normalized to the methyl signal (≈0.9 ppm) to assess changes in free fatty acid content was demonstrated by measuring differences in spectra acquired from a triglyceride peanut oil phantom and from a phantom composed of a mixture of peanut oil and free fatty acid oleic acid.  相似文献   

13.
In vitro 1H MRS of human bile has shown potential in the diagnosis of various hepatopancreatobiliary (HPB) diseases. Previously, in vivo 1H MRS of human bile in gallbladder using a 1.5 T scanner demonstrated the possibility of quantification of choline‐containing phospholipids (chol‐PLs). However, other lipid components such as bile acids play an important role in the pathophysiology of the HPB system. We have employed a higher magnetic field strength (3 T), and a custom‐built receive array coil, to improve the quality of in vivo 1H MRS of human bile in the gallbladder. We obtained significant improvement in the quality of 1D spectra (17 healthy volunteers) using a respiratory‐gated PRESS sequence with well distinguished signals for total bile acids (TBAs) plus cholesterol resonating at 0.66 ppm, taurine‐conjugated bile acids (TCBAs) at 3.08 ppm, chol‐PLs at 3.22 ppm, glycine‐conjugated bile acids (GCBAs) at 3.74 ppm, and the amide proton (?NH) arising from GCBAs and TCBAs in the region 7.76–8.05 ppm. The peak areas of these signals were measured by deconvolution, and subsequently the molar concentrations of metabolites were estimated with good accuracy, except for that of TBAs plus cholesterol. The concentration of TBAs plus cholesterol was overestimated in some cases, which could be due to lipid contamination. In addition, we report the first 2D L‐COSY spectra of human gallbladder bile in vivo (obtained in 15 healthy volunteers). 2D L‐COSY spectra will be helpful in differentiating various biliary chol‐PLs in pathological conditions of the HPB system. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

14.
Alterations in the hepatic lipid content (HLC) and fatty acid composition are associated with disruptions in whole body metabolism, both in humans and in rodent models, and can be non‐invasively assessed by 1H‐MRS in vivo. We used 1H‐MRS to characterize the hepatic fatty‐acyl chains of healthy mice and to follow changes caused by streptozotocin (STZ) injection. Using STEAM at 14.1 T with an ultra‐short TE of 2.8 ms, confounding effects from T2 relaxation and J‐coupling were avoided, allowing for accurate estimations of the contribution of unsaturated (UFA), saturated (SFA), mono‐unsaturated (MUFA) and poly‐unsaturated (PUFA) fatty‐acyl chains, number of double bonds, PU bonds and mean chain length. Compared with in vivo 1H‐MRS, high resolution NMR performed in vitro in hepatic lipid extracts reported longer fatty‐acyl chains (18 versus 15 carbons) with a lower contribution from UFA (61 ± 1% versus 80 ± 5%) but a higher number of PU bonds per UFA (1.39 ± 0.03 versus 0.58 ± 0.08), driven by the presence of membrane species in the extracts. STZ injection caused a decrease of HLC (from 1.7 ± 0.3% to 0.7 ± 0.1%), an increase in the contribution of SFA (from 21 ± 2% to 45 ± 6%) and a reduction of the mean length (from 15 to 13 carbons) of cytosolic fatty‐acyl chains. In addition, SFAs were also likely to have increased in membrane lipids of STZ‐induced diabetic mice, along with a decrease of the mean chain length. These studies show the applicability of 1H‐MRS in vivo to monitor changes in the composition of the hepatic fatty‐acyl chains in mice even when they exhibit reduced HLC, pointing to the value of this methodology to evaluate lipid‐lowering interventions in the scope of metabolic disorders. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
16.
17.
Oxidative damage is a central feature of ulcerative colitis. Here, we tested whether the antioxidant Mesna, when administered alone or in combination with n‐3 polyunsaturated fatty acids (n‐3 PUFAs), affects the outcome of dextran sodium sulphate (DSS)‐induced ulcerative colitis in rats. After the induction of colitis, DSS‐treated rats were further treated orally (p.o), intraperitoneally (i.p) or intrarectally (i.r) for either 7 or 14 days with Mesna, n‐3 PUFAs or both. Rats were euthanized at the end of each treatment period. Clinical disease activity index was recorded throughout the experiment. At necropsy colorectal gross lesions were scored. Colitis was scored histologically, and the expression of myeloperoxidase (MPO), caspase‐3, inducible nitric oxide synthase (iNOS) and nuclear factor κB (NF‐κΒ) in colonic tissue was assessed by immunohistochemistry. Mesna alone was sufficient to significantly reduce colorectal tissue damage when administered orally or intraperitoneally. Orally coadministered n‐3 PUFAs enhanced this effect, resulting in the significant suppression of DSS colitis after 7 days, and a remarkable recovery of colorectal mucosa was evident after 14 days of treatment. The amelioration of colon pathology co‐existed with a significant decrease in MPO expression, overexpression of iNOS and reduction of nuclear NF‐κB p65 in inflammatory cells, and the suppression of apoptosis in colonic epithelial cells. The simultaneous administration of Mesna and n‐3 PUFAs is particularly effective in ameliorating DSS colitis in rats, by reducing oxidative stress, inflammation and apoptosis, probably through a mechanism that involves the inhibition of NF‐κB and overexpression of iNOS.  相似文献   

18.
Magnetic resonance spectroscopy (MRS) is a powerful tool capable of investigating the metabolic status of several tissues in vivo. In particular, single‐voxel‐based 1H spectroscopy provides invaluable biochemical information from a volume of interest (VOI) and has therefore been used in a variety of studies. Unfortunately, typical one‐dimensional MRS data suffer from severe signal overlap and thus important metabolites are difficult to distinguish. One method that is used to disentangle overlapping resonances is the two‐dimensional J‐resolved spectroscopy (JPRESS) experiment. Due to the long acquisition duration of the JPRESS experiment, a limited number of points are acquired in the indirect dimension, leading to poor spectral resolution along this dimension. Poor spectral resolution is problematic because proper peak assignment may be hindered, which is why the zero‐filling method is often used to improve resolution as a post‐processing step. However, zero‐filling leads to spectral artifacts, which may affect visualization and quantitation of spectra. A novel method utilizing a covariance transformation, called covariance J‐resolved spectroscopy (CovJ), was developed in order to improve spectral resolution along the indirect dimension (F1). Comparison of simulated data demonstrates that peak structures remain qualitatively similar between JPRESS and the novel method along the diagonal region (F1 = 0 Hz), whereas differences arise in the cross‐peak (F1≠0 Hz) regions. In addition, quantitative results of in vivo JPRESS data acquired on a 3T scanner show significant correlations (r2>0.86, p<0.001) when comparing the metabolite concentrations between the two methods. Finally, a quantitation algorithm, ‘COVariance Spectral Evaluation of 1H Acquisitions using Representative prior knowledge’ (Cov‐SEHAR), was developed in order to quantify γ‐aminobutyric acid and glutamate from the CovJ spectra. These preliminary findings indicate that the CovJ method may be used to improve spectral resolution without hindering metabolite quantitation for J‐resolved spectra.  相似文献   

19.
Short‐TE MRS has been proposed recently as a method for the in vivo detection and quantification of γ‐aminobutyric acid (GABA) in the human brain at 3 T. In this study, we investigated the accuracy and reproducibility of short‐TE MRS measurements of GABA at 3 T using both simulations and experiments. LCModel analysis was performed on a large number of simulated spectra with known metabolite input concentrations. Simulated spectra were generated using a range of spectral linewidths and signal‐to‐noise ratios to investigate the effect of varying experimental conditions, and analyses were performed using two different baseline models to investigate the effect of an inaccurate baseline model on GABA quantification. The results of these analyses indicated that, under experimental conditions corresponding to those typically observed in the occipital cortex, GABA concentration estimates are reproducible (mean reproducibility error, <20%), even when an incorrect baseline model is used. However, simulations indicate that the accuracy of GABA concentration estimates depends strongly on the experimental conditions (linewidth and signal‐to‐noise ratio). In addition to simulations, in vivo GABA measurements were performed using both spectral editing and short‐TE MRS in the occipital cortex of 14 healthy volunteers. Short‐TE MRS measurements of GABA exhibited a significant positive correlation with edited GABA measurements (R = 0.58, p < 0.05), suggesting that short‐TE measurements of GABA correspond well with measurements made using spectral editing techniques. Finally, within‐session reproducibility was assessed in the same 14 subjects using four consecutive short‐TE GABA measurements in the occipital cortex. Across all subjects, the average coefficient of variation of these four GABA measurements was 8.7 ± 4.9%. This study demonstrates that, under some experimental conditions, short‐TE MRS can be employed for the reproducible detection of GABA at 3 T, but that the technique should be used with caution, as the results are dependent on the experimental conditions. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
The purpose of this work was to investigate the effect of J‐coupling interactions on the quantification and T2 determination of 1.3‐ppm lipid methylene protons at 3 T. The response of the 1.3‐ppm protons of hexanoic, heptanoic, octanoic, linoleic and oleic acid was measured as a function of point‐resolved spectroscopy (PRESS) and stimulated echo acquisition mode (STEAM) TE. In addition, a narrow‐bandwidth refocusing PRESS sequence designed to rewind J‐coupling evolution of the 1.3‐ppm protons was applied to the five fatty acids, to corn oil and to tibial bone marrow of six healthy volunteers. Peak areas were plotted as a function of TE, and data were fitted to monoexponentially decaying functions to determine Mo (the extrapolated area for TE = 0 ms) and T2 values. In phantoms, rewinding J‐coupling evolution resulted in 198%, 64%, 44%, 20% and 15% higher T2 values for heptanoic, octanoic, linoleic and oleic acid, and corn oil, respectively, compared with those obtained with standard PRESS. The narrow‐bandwidth PRESS sequence also resulted in significant changes in Mo, namely ?77%, ?22%, 28%, 23% and 28% for heptanoic, octanoic, linoleic and oleic acid, and corn oil, respectively. T2 values obtained with STEAM were closer to the values measured with narrow‐bandwidth PRESS. On average, in tibial bone marrow (six volunteers) rewinding J‐coupling evolution resulted in 21% ± 3% and 9 % ± 1% higher Mo and T2 values, respectively. This work demonstrates that the consequence of neglecting to consider scalar coupling effects on the quantification of 1.3‐ppm lipid methylene protons and their T2 values is not negligible. The linoleic and oleic acid T2 results indicate that T2 measures of lipids with standard MRS techniques are dependent on lipid composition. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号