首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ObjectivesThe aim of this study was to compare outcomes after transcatheter aortic valve replacement (TAVR) in patients with pure aortic stenosis (AS) (i.e., no or trivial associated aortic regurgitation [AR]) with those in patients with AS and mild or more severe AR (i.e., mixed aortic valve disease [MAVD]).BackgroundTAVR is indicated in treating patients with severe AS. Limited data exist regarding the outcomes of TAVR in patients with MAVD.MethodsA total of 1,133 patients who underwent TAVR between January 2014 and December 2017 were included. The primary outcome was all-cause mortality. The comparison was adjusted to account for post-TAVR AR development in both groups. The secondary outcomes included composite endpoints of early safety and clinical efficacy as specified in the Valve Academic Research Consortium-2 criteria. Variables were compared using Mann-Whitney, chi-square, and Fisher exact tests, while Kaplan-Meier analyses were used to compare survival.ResultsA total of 688 patients (61%) had MAVD (median age 83 years , 43% women). Among these, 17% developed mild, 2% moderate, and <1% severe post-TAVR AR. Overall, patients with MAVD had better survival compared with patients with pure AS (p = 0.03). Among patients who developed post-TAVR AR, those in the MAVD group had better survival (p = 0.04). In contrast, in patients who did not develop post-TAVR AR, pre-TAVR AR did not improve survival (p = 0.11).ConclusionsPatients with MAVD who underwent TAVR had better survival compared with patients with pure AS. This is explained by the better survival of patients with MAVD who developed post-TAVR AR, likely due to left ventricular adaptation to AR.  相似文献   

2.

Objectives

This study sought to evaluate the trends in isolated surgical aortic valve replacement (SAVR) procedures across hospitals with different transcatheter aortic valve replacement (TAVR) volumes among Medicare beneficiaries.

Background

The volume of TAVR has increased in the United States since its approval, now exceeding that of isolated SAVR.

Methods

Hospitalizations of adults (≥18 years of age) with International Classification of Diseases-9th Revision-Clinical Modification procedure codes for SAVR (35.21 or 35.22) or TAVR (35.05 or 35.06) who were included in the Medicare Provider Analysis and Review database between January 1, 2011, and December 31, 2014, were included. Trends in isolated SAVR patient characteristics, procedural volumes, and outcomes by quartile (Q) of hospital-level TAVR use were assessed over the study period.

Results

A total of 37,705 isolated SAVR procedures were analyzed for the study. The annual volume of isolated SAVR procedures decreased in hospitals performing the largest number of TAVR procedures (Q3: 1,557 in 2011 to 1,391 in 2014; and Q4: 2,607 in 2011 to 1,791 in 2014). Thirty-day and 1-year mortality after SAVR also declined over the study period in hospitals with the largest TAVR volume (annual change rate in mortality for Q3: ?16.4%; p < 0.001; Q4: ?20.8%; p < 0.001).

Conclusions

The advent of TAVR was associated with a reduction in isolated SAVR volumes, a decrease in comorbidities among patients undergoing SAVR, and corresponding reductions in observed short- and long-term SAVR mortality among hospitals performing the greatest number of TAVRs.  相似文献   

3.
4.

Objectives

The aims of this study were to report on the use of local anesthesia or conscious sedation (LACS) and general anesthesia in transcatheter aortic valve replacement and to analyze the impact on outcome.

Background

Transcatheter aortic valve replacement can be performed in LACS or general anesthesia. Potential benefits of LACS, such as faster procedures and shorter hospital stays, need to be balanced with safety.

Methods

A total of 16,543 patients from the German Aortic Valve Registry from 2011 to 2014 were analyzed, and propensity-matched analyses were performed to correct for potential selection bias.

Results

LACS was used in 49% of patients (8,121 of 16,543). In hospital, LACS was associated with lower rates of low-output syndrome, respiratory failure, delirium, cardiopulmonary resuscitation, and death. There was no difference in paravalvular leakage (II+) between LACS and general anesthesia in the entire population (5% vs. 4.8%; p = 0.76) or in the matched population (3.9% vs. 4.9%, p = 0.13). The risk for prolonged intensive care unit stay (≥3 days) was significantly reduced with LACS (odds ratio: 0.82; 95% confidence interval [CI]: 0.73 to 0.92; p = 0.001). Thirty-day mortality was lower with LACS in the entire population (3.5% vs. 4.9%; hazard ratio [HR]: 0.72; 95% CI: 0.60 to 0.86; p < 0.001) and in the matched population (2.8% vs. 4.6%; HR: 0.6; 95% CI: 0.45 to 0.8; p < 0.001). However, no differences in 1-year mortality between both groups in the entire population (16.5% vs. 16.9%; HR: 0.93; 95% CI: 0.85 to 1.02; p = 0.140) and in the propensity-matched population (14.1% vs. 15.5%; HR: 0.90; 95% CI: 0.78 to 1.03; p = 0.130) were observed.

Conclusions

Use of LACS in transcatheter aortic valve replacement is safe, with fewer post-procedural complications and lower early mortality, suggesting its broad application.  相似文献   

5.
6.

Objectives

This study sought to develop a novel technique called bioprosthetic or native aortic scallop intentional laceration to prevent coronary artery obstruction (BASILICA).

Background

Coronary artery obstruction is a rare but fatal complication of transcatheter aortic valve replacement (TAVR).

Methods

We lacerated pericardial leaflets in vitro using catheter electrosurgery, and tested leaflet splaying after benchtop TAVR. The procedure was tested in swine. BASILICA was then offered to patients at high risk of coronary obstruction from TAVR and ineligible for surgical aortic valve replacement. BASILICA used marketed devices. Catheters directed an electrified guidewire to traverse and lacerate the aortic leaflet down the center line. TAVR was performed as usual.

Results

TAVR splayed lacerated bovine pericardial leaflets. BASILICA was successful in pigs, both to left and right cusps. Necropsy revealed full length lacerations with no collateral thermal injury. Seven patients underwent BASILICA on a compassionate basis. Six had failed bioprosthetic valves, both stented and stent-less. Two had severe aortic stenosis, including 1 patient with native disease, 3 had severe aortic regurgitation, and 2 had mixed aortic valve disease. One patient required laceration of both left and right coronary cusps. There was no hemodynamic compromise in any patient following BASILICA. All patients had successful TAVR, with no coronary obstruction, stroke, or any major complications. All patients survived to 30 days.

Conclusions

BASILICA may durably prevent coronary obstruction from TAVR. The procedure was successful across a range of presentations, and requires further evaluation in a prospective trial. Its role in treatment of degenerated TAVR devices remains untested.  相似文献   

7.

Objectives

This study sought to evaluate whether a multimarker approach might identify patients with higher mortality and hospitalization rates after aortic valve replacement (AVR) for aortic stenosis (AS).

Background

The society valve guidelines include accepted triggers for AVR in patients with severe asymptomatic AS, but circulating biomarkers do not have a clear role.

Method

From a prospective registry of patients undergoing cardiac surgery between 2000 and 2012, 665 treated with surgical AVR (441 isolated) were evaluated. Seven biomarkers were measured on blood samples obtained before AVR. Biomarker levels were adjusted to account for the influence of age, sex, body mass index, and renal function; the median was used to determine an elevated value. Endpoints included all-cause mortality and all-cause and cardiovascular hospitalizations. Mean follow-up was 10.7 years and 299 (45%) died.

Results

Patients with 0 to 1, 2 to 3, 4 to 6, and 7 biomarkers elevated had 5-year mortality of 10%, 12%, 24%, and 33%, respectively, and 10-year mortality of 24%, 35%, 58%, and 71%, respectively (log-rank p < 0.001). The association between an increasing number of elevated biomarkers and increased all-cause mortality was observed among those with minimal symptoms (New York Heart Association functional class I or II) and those with a low N-terminal pro–B-type natriuretic peptide (p < 0.01 for both). Compared with those with 0 to 1 biomarkers elevated, patients with 4 to 6 or 7 biomarkers elevated had an increased hazard of mortality after adjustment for clinical risk scores (p < 0.01) and a 2- to 3-fold higher rate of all-cause and cardiovascular rehospitalization after AVR. Similar findings were obtained when evaluating cardiovascular mortality. Among patients with no or minimal symptoms, 42% had ≥4 biomarkers elevated.

Conclusions

Among patients with severe AS treated with surgical AVR, an increasing number of elevated biomarkers of cardiovascular stress was associated with higher all-cause and cardiovascular mortality and a higher rate of repeat hospitalization. A multimarker approach may be useful in the surveillance of asymptomatic patients with severe AS to optimize surgical timing.  相似文献   

8.

Background

It is unclear whether the Ross procedure offers superior survival compared with mechanical aortic valve replacement (AVR).

Objectives

This study evaluated experience and compared long-term survival between the Ross procedure and mechanical AVR.

Methods

Between 1992 and 2016, a total of 392 Ross procedures were performed. These were compared with 1,928 isolated mechanical AVRs performed during the same time period as identified using the University of Melbourne and Australia and New Zealand Society of Cardiac and Thoracic Surgeons’ Cardiac Surgery Databases. Only patients between 18 and 65 years of age were included. Propensity-score matching was performed for risk adjustment.

Results

Ross procedure patients were younger, and had fewer cardiovascular risk factors. The Ross procedure was associated with longer cardiopulmonary bypass and aortic cross-clamp times. Thirty-day mortality was similar (Ross, 0.3%; mechanical, 0.8%; p = 0.5). Ross procedure patients experienced superior unadjusted long-term survival at 20 years (Ross, 95%; mechanical, 68%; p < 0.001). Multivariable analysis showed the Ross procedure to be associated with a reduced risk of late mortality (hazard ratio: 0.34; 95% confidence internal: 0.17 to 0.67; p < 0.001). Among 275 propensity-score matched pairs, Ross procedure patients had superior survival at 20 years (Ross, 94%; mechanical, 84%; p = 0.018).

Conclusions

In this Australian, propensity-score matched study, the Ross procedure was associated with better long-term survival compared with mechanical AVR. In younger patients, with a long life expectancy, the Ross procedure should be considered in centers with sufficient expertise.  相似文献   

9.
10.
11.

Background

Spontaneous ruptured aortic plaques (SRAP), which might cause atheromatous embolization, are thought to be mainly iatrogenic and have not been observed directly.

Objectives

The purpose of this study was to clarify the incidence, types, and dimensions of SRAP using angioscopy.

Methods

In a cross-sectional study, 324 consecutive patients diagnosed with or suspected of having coronary artery disease were subjected to intra-aortic scans with nonobstructive angioscopy. Samples of SRAP were taken from the aorta. The dimensions of cholesterol crystals of atheromatous materials were measured with a polarizing microscope and compared with those of the ghost images of cholesterol crystals.

Results

SRAP were detected in 262 patients (80.9%); 120 of 262 patients had ruptured aortic plaques below the diaphragmatic level. Samples were successfully obtained from 96 patients. The detected numbers of atheromatous material, fibrin, macrophage, and calcification were 237 (49.1%), 244 (50.6%), 111 (23.0%), and 127 (26.3%) out of 482 samples, respectively. The median lengths and widths of the sampled plaques were 254 μm (interquartile range [IQR]: 100 to 685 μm) and 148 μm (IQR: 535 to 423.5 μm), respectively. The lengths and widths of the cholesterol crystals isolated from atheromatous materials were 40 μm (IQR: 32.7 to 53.7 μm), and 30 μm (IQR: 23 to 38 μm), respectively, compared with the respective dimensions of the ghost images of 86 μm (IQR: 53 to 119) and 13 μm (IQR: 7 to 18 μm). No embolic symptoms were observed within 24 h of general care via cardiac catheterization.

Conclusions

SRAP are commonly scattered, and their dimensions were smaller than previously recognized. (Detecting Ruptured Aortic Plaques by Nonobstructive Angioscopy; UMIN000029772)  相似文献   

12.
13.

Objectives

The aim of this study was to assess the implications of concomitant tricuspid regurgitation (TR) in patients undergoing valve-in-valve (VIV) transcatheter aortic valve replacement.

Background

Patients undergoing VIV transcatheter aortic valve replacement with concomitant TR may have worse outcomes, and optimal management remains undetermined.

Methods

The multicenter PARTNER 2 (Placement of Aortic Transcatheter Valves) VIV trial enrolled patients with symptomatic degenerated surgical aortic bioprostheses who were at high risk for reoperation. Outcomes were assessed between patients with mild or no TR versus moderate or severe TR.

Results

A total of 237 patients underwent VIV procedures (mean age 78.7 ± 10.8 years, mean Society of Thoracic Surgeons score 9.1 ± 4.8%). In this cohort, 162 patients (68.4%) had mild or no TR, and 75 patients (31.6%) had moderate or severe TR. Although there was no difference in New York Heart Association functional class III or IV symptomatic status (89.3% vs. 91.4%; p = 0.62) or moderate or severe right ventricular dysfunction (9.4% vs. 16.9%; p = 0.11), patients with moderate or severe TR were more likely to be at high surgical risk, with a Society of Thoracic Surgeons score of >8 (62.7% vs 46.9%; p = 0.02). There was no difference in a composite endpoint of death and rehospitalization between moderate or severe TR and mild or no TR, either at 30 days (10.7% vs. 9.9%; p = 0.85) or at 1-year follow-up (24.1% vs. 23.2%; p = 0.80). There was a significant reduction in overall moderate or severe TR from baseline at 30 days (31.1% vs. 21.1%; p = 0.002), which was sustained at 1-year follow-up (38.0% vs. 22.8%; p = 0.004).

Conclusions

Despite higher predicted surgical risk, the presence of TR was not a predictor of long-term outcomes. Importantly, there was significant reduction in TR severity at both short- and long-term follow-up. In selected patients undergoing VIV transcatheter aortic valve replacement, it may be appropriate to conservatively manage concomitant TR.  相似文献   

14.
Prosthesis-patient mismatch (PPM) occurs when the effective orifice area (EOA) of the prosthetic valve is too small in relation to a patient’s body size, thus resulting in high residual postoperative pressure gradients across the prosthesis. Severe PPM occurs in 2% to 20% of patients undergoing surgical aortic valve replacement (AVR) and is associated with 1.5- to 2.0-fold increase in the risk of mortality and heart failure rehospitalization. The purpose of this article is to present an overview of the role of multimodality imaging in the assessment, prediction, prevention, and management of PPM following AVR. The risk of PPM can be anticipated at the time of AVR by calculating the predicted indexed from the normal reference value of EOA of the selected prosthesis and patient’s body surface area. The strategies to prevent PPM at the time of surgical AVR include: 1) implanting a newer generation of prosthetic valve with better hemodynamic; 2) enlarging the aortic root or annulus to accommodate a larger prosthetic valve; or 3) performing TAVR rather than surgical AVR. The identification and quantitation of PPM as well as its distinction versus prosthetic valve stenosis is primarily based on transthoracic echocardiography, but important information may be obtained from other imaging modalities such as transesophageal echocardiography and multidetector computed tomography. PPM is characterized by high transprosthetic velocity and gradients, normal EOA, small indexed EOA, and normal leaflet morphology and mobility. Transesophageal echocardiography and multidetector computed tomography are particularly helpful to assess prosthetic valve leaflet morphology and mobility, which is a cornerstone of the differential diagnosis between PPM and pathologic valve obstruction. Severe symptomatic PPM following AVR with a bioprosthetic valve may be treated by redo surgery or the transcatheter valve-in-valve procedure with fracturing of the surgical valve stent.  相似文献   

15.
16.
ObjectivesThe purpose of the study was to investigate the impact of oral anticoagulation (OAC) type on clinical outcomes 1 year after transcatheter aortic valve replacement (TAVR).BackgroundNon–vitamin K oral anticoagulants (NOACs) are superior to vitamin K antagonists (VKAs) in nonvalvular atrial fibrillation (AF), while their comparative performance among patients in need of OAC undergoing TAVR is underinvestigated.MethodsThe study enrolled 962 consecutive patients who underwent TAVR in 4 tertiary European centers and were discharged on either NOACs (n = 326) or VKAs (n = 636). By using propensity scores for inverse probability of treatment weighting (IPTW), the comparison of treatment groups was adjusted to correct for potential confounding.ResultsMean age and Society of Thoracic Surgeons score of the population were 81.3 ± 6.3 years and 4.5% (interquartile range: 3.0% to 7.3%); 52.5% were women and a balloon-expandable valve was used in 62.7% of cases. The primary outcome of interest, combined incidence of all-cause mortality, myocardial infarction, and any cerebrovascular event at 1-year after TAVR, was 21.2% with NOACs versus 15.0% with VKAs (hazard ratio [HR]: 1.44; 95% confidence interval [CI]: 1.00 to 2.07; p = 0.050, IPTW-adjusted). The 1-year incidence of any Bleeding Academic Research Consortium bleeds and all-cause mortality were comparable between the NOAC and VKA groups, 33.9% versus 34.1% (HR: 0.97; 95% CI: 0.74 to 1.26; p = 0.838, IPTW-adjusted) and 16.5% versus 12.2% (HR: 1.36; 95% CI: 0.90 to 2.06; p = 0.136, IPTW-adjusted), respectively.ConclusionsChronic use of both NOACs and VKAs among patients in need of OAC after TAVR are comparable regarding 1-year bleeding risk. The higher ischemic event rate observed with NOACs needs to be evaluated in large randomized trials.  相似文献   

17.
ObjectivesThis study sought to ascertain whether patients with a bicuspid aortic valve (BAV) have an intrinsic alteration in regional aortic stiffness compared with patients with tricuspid aortic valve (TAV) and Marfan syndrome (MFS) patients with similar aortic sizes, as well as to assess the influence of ascending aorta (AAo) dilation on regional stiffness parameters in BAV patients.BackgroundImaging biomarkers as predictors of BAV, MFS, and degenerative AAo aneurysms in TAV patients (DA-TAV) are lacking. Biomechanical characterization has been proposed as a possible tool for further aneurysm stratification.MethodsA total 234 subjects (136 BAV, 44 MFS, and 18 DA-TAV patients and 36 healthy control subjects) were included. The cardiac magnetic resonance protocol comprised 4-dimensional flow to assess AAo and descending aorta (DAo) pulse wave velocities (PWVs) and double-oblique, 2-dimensional, steady-state free-precession cine cardiac magnetic resonance to compute aortic distensibility (AD).ResultsOn adjusted analysis, nondilated BAV patients had similar PWV and AD as healthy control subjects in both AAo and DAo, whereas dilated BAV did not differ from DA-TAV. In contrast, AAo and DAo stiffness in MFS patients was markedly greater than in BAV patients, increasing slightly with dilation severity. AAo PWV showed a biphasic pattern in BAV patients: it first decreased and then increased throughout AAo dilation, with a clear turning point at 50 mm, whereas distensibility did not discern mildly dilated aorta. In multivariate analysis adjusted for clinical and demographic characteristics, only PWV was related to AAo dilation in BAV patients.ConclusionsThe mechanical properties of AAo aneurysms are similar in BAV and TAV patients, whereas MFS patients have a stiffer aorta. Aortic stiffness strongly depends on dilation severity. AAo PWV resulted in a potentially clinically useful biphasic trend with respect to aneurysm diameter, whereas distensibility did not discern mildly dilated aorta. Beyond clinical risk factors, PWV but not AD was independently related to AAo dilation in BAV patients.  相似文献   

18.
The management of patients with valvular heart disease is increasingly reliant on multimodal cardiac imaging. In patients with severe aortic stenosis considered for transcatheter aortic valve replacement, careful pre-procedural planning with multimodal imaging is necessary to avoid and prevent complications during the procedure. During or immediately after the procedure, rapid echocardiographic assessment is important to assess the new valve’s function and manage major complications. Echocardiography, cardiac computed tomography, and cardiac magnetic resonance imaging all share important roles in the post-procedural evaluation of abnormal transcatheter valve function. This review discusses the use of multimodal imaging for predicting, detecting, and managing complications after TAVR.  相似文献   

19.
20.

Background

Left ventricular (LV) hypertrophy, a key process in human cardiac disease, results from cellular (hypertrophy) and extracellular matrix expansion (interstitial fibrosis).

Objectives

This study sought to investigate whether human myocardial interstitial fibrosis in aortic stenosis (AS) is plastic and can regress.

Methods

Patients with symptomatic, severe AS (n = 181; aortic valve area index 0.4 ± 0.1 cm2/m2) were assessed pre–aortic valve replacement (AVR) by echocardiography (AS severity, diastology), cardiovascular magnetic resonance (CMR) (for volumes, function, and focal or diffuse fibrosis), biomarkers (N-terminal pro–B-type natriuretic peptide and high-sensitivity troponin T), and the 6-min walk test. CMR was used to measure the extracellular volume fraction (ECV), thereby deriving matrix volume (LV mass × ECV) and cell volume (LV mass × [1 ? ECV]). Biopsy excluded occult bystander disease. Assessment was repeated at 1 year post-AVR.

Results

At 1 year post-AVR in 116 pacemaker-free survivors (age 70 ± 10 years; 54% male), mean valve gradient had improved (48 ± 16 mm Hg to 12 ± 6 mm Hg; p < 0.001), and indexed LV mass had regressed by 19% (88 ± 26 g/m2 to 71 ± 19 g/m2; p < 0.001). Focal fibrosis by CMR late gadolinium enhancement did not change, but ECV increased (28.2 ± 2.9% to 29.9 ± 4.0%; p < 0.001): this was the result of a 16% reduction in matrix volume (25 ± 9 ml/m2 to 21 ± 7 ml/m2; p < 0.001) but a proportionally greater 22% reduction in cell volume (64 ± 18 ml/m2 to 50 ± 13 ml/m2; p < 0.001). These changes were accompanied by improvement in diastolic function, N-terminal pro–B-type natriuretic peptide, 6-min walk test results, and New York Heart Association functional class.

Conclusions

Post-AVR, focal fibrosis does not resolve, but diffuse fibrosis and myocardial cellular hypertrophy regress. Regression is accompanied by structural and functional improvements suggesting that human diffuse fibrosis is plastic, measurable by CMR and a potential therapeutic target. (Regression of Myocardial Fibrosis After Aortic Valve Replacement; NCT02174471)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号