首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Multidetector-row computed tomography (MDCT) and magnetic resonance (MR) imaging are currently the most frequently performed imaging modalities for the study of pancreatic disease. In cases of suspected autoimmune pancreatitis (AIP), a dynamic quadriphasic (precontrast, contrast-enhanced pancreatic, venous and late phases) study is recommended in both techniques. In the diffuse form of autoimmune pancreatitis (DAIP), the pancreatic parenchyma shows diffuse enlargement and appears, during the MDCT and MR contrast-enhanced pancreatic phase, diffusely hypodense and hypointense, respectively, compared to the spleen because of lymphoplasmacytic infiltration and pancreatic fibrosis. During the venous phase of MDCT and MR imaging, the parenchyma appears hyperdense and hyperintense, respectively, in comparison to the pancreatic phase. In the delayed phase of both imaging modalities, it shows retention of contrast media. A “capsule-like rim” may be recognised as a peripancreatic MDCT hyperdense and MR hypointense halo in the T2-weighted images, compared to the parenchyma. DAIP must be differentiated from non-necrotizing acute pancreatitis (NNAP) and lymphoma since both diseases show diffuse enlargement of the pancreatic parenchyma. The differential diagnosis is clinically difficult, and dynamic contrast-enhanced MDCT has an important role. In the focal form of autoimmune pancreatitis (FAIP), the parenchyma shows segmental enlargement involving the head, the body-tail or the tail, with the same contrast pattern as the diffuse form on both modalities. FAIP needs to be differentiated from pancreatic adenocarcinoma to avoid unnecessary surgical procedures, since both diseases have similar clinical and imaging presentation. The differential diagnosis is clinically difficult, and dynamic contrast-enhanced MDCT and MR imaging both have an important role. MR cholangiopancreatography helps in the differential diagnosis. Furthermore, MDCT and MR imaging can identify the extrapancreatic manifestations of AIP, most commonly biliary, renal and retroperitoneal. Finally, in all cases of uncertain diagnosis, MDCT and/or MR follow-up after short-term treatment (2–3 weeks) with high-dose steroids can identify a significant reduction in size of the pancreatic parenchyma and, in FAIP, normalisation of the calibre of the upstream main pancreatic duct.  相似文献   

2.

Purpose

The aim of this study was to evaluate the diagnostic accuracy of postnatal multidetector computed tomography (MDCT) compared with prenatal ultrasound (US), surgical findings, and histology, in 33 patients with congenital cystic lung disease.

Methods

Thirty-three patients, 17 males and 16 females, were evaluated by MDCT. Twenty-seven of these patients underwent prenatal US between week 18 and 22, and between week 32 and 35 of gestation. Lung lobectomy, segmentectomy, atypical resection, lesion resection were performed in 31 patients and surgical specimens were analysed.

Results

Prenatal US and MDCT correctly diagnosed 76.9 and 94 % of the lesions, respectively. Disagreement occurred in six lesions with prenatal US and in two lesions with MDCT. No statistically significant differences were observed between the two techniques (P = 0.122).

Conclusions

As most surgeons consider the surgical resection of these lesions mandatory, our study underscores the essential role of imaging, in particular CT, in providing invaluable preoperative information on congenital cystic lung diseases recognised in uterus.  相似文献   

3.
This article reviews the normal postsurgical anatomy and appearance of PCL reconstructions on MDCT and MRI with the different operative techniques considering the type of tibial fixation, use of a single or double bundle, type of tendon graft and the fixation material. Tunnel positioning, appearance of the ligament graft and findings at the donor site are considered. Imaging signs of PCL graft failure and its possible causes are discussed. Imaging manifestations of other potential complications of both the PCL graft and donor sites are described, such as laxity, impingement, arthrofibrosis, ganglion cyst formation or complications related to the fixation material.  相似文献   

4.
Thoracic multidetector computed tomography—MDCT—was simultaneously performed during emergency abdominal CT in a patient presenting with abdominal pain and acute cardiogenic edema related to sick sinus syndrome and mitral prolapse with regurgitation. A constellation of severe but completely reversible interstitial and mediastinal features was found comprising pleural effusions, diffuse alveolar ground glass, thickening of the bronchial walls and septal lines, hazy infiltration of the mediastinal fat, and enlarged lymphatic nodes. Multiple atypical hypodense nodular “pearls” were also found. These oval shape or fusiform pearls were distributed along the thickened septal lines and disappeared completely after treatment. The hypothesis of transient lymphatic ectasia or lakes is proposed for these never previously described abnormalities.  相似文献   

5.

Objective

Our objective was to evaluate ultrafast cone-beam computed tomography (u-CBCT) image data using cross-sectional images, perfusion blood volume (PBV), and image fusion during tumour detection at the course of transarterial chemoembolization.

Methods

One hundred and fifty patients (63?±?20 years; 33–82) were examined from February to October 2013 with u-CBCT. Tumour delineation and conspicuity were determined using u-CBCT cross-sectional PBV and u-CBCT-magnetic resonance imaging (MRI) fused data sets for hyperenhanced (HYET), heterogeneously enhanced (HEET), and unenhanced (UET) tumour categories. Catheter localisation and tumour feeding vessels were assessed using all data sets. Quantitative and qualitative analyses were performed using appropriate statistical tests.

Result

Qualitative and quantitative tumour delineation showed significant difference (all P?P?P?Conclusion Tumour delineation was clearly possible using u-CBCT cross sections with contrast material. PBV uses color-coded images to increase detection and produces good tumour differentiation. Image fusion helps accurately identify tumour and feeding vessels and locate contrast material injection sites and catheter tips without additional data acquisition.

Key points

? Ultrafast CBCT cross-sectional data provide good tumour delineation with contrast material ? Postprocessed PBV using u-CBCT increased detectability and tumour differentiation ? u-CBCT cross-sectional PBV and u-CBCT-MRI data helps image guidance during chemoembolization ? u-CBCT-MRI can identify tumours and feeding vessels and locate catheter tip accurately  相似文献   

6.
Published data on the diagnosis of bone metastases of prostate cancer are conflicting and heterogeneous. We performed a comprehensive meta-analysis to compare the diagnostic performance of choline-PET/CT, MRI, bone SPECT, and bone scintigraphy (BS) in detecting bone metastases in parents with prostate cancer. Pooled sensitivity, specificity, and diagnostic odds ratios (DOR) were calculated both on a per-patient basis and on a per-lesion basis. Summary receiver operating characteristic (SROC) curves were also drawn to obtain the area under curve (AUC) and Q* value. Sixteen articles consisting of 27 studies were included in the analysis. On a per-patient basis, the pooled sensitivities by using choline PET/CT, MRI, and BS were 0.91 [95 % confidence interval (CI): 0.83–0.96], 0.97 (95 % CI: 0.91–0.99), 0.79 (95 % CI: 0.73–0.83), respectively. The pooled specificities for detection of bone metastases using choline PET/CT, MRI, and BS, were 0.99 (95 % CI: 0.93–1.00), 0.95 (95 % CI: 0.90–0.97), and 0.82 (95 % CI: 0.78–0.85), respectively. On a per-lesion basis, the pooled sensitivities of choline PET/CT, bone SPECT, and BS were 0.84 (95 % CI: 0.81–0.87), 0.90 (95 % CI: 0.86–0.93), 0.59 (95 % CI: 0.55–0.63), respectively. The pooled specificities were 0.93 (95 % CI: 0.89–0.96) for choline PET/CT, 0.85 (95 % CI: 0.80–0.90) for bone SPECT, and 0.75 (95 % CI: 0.71–0.79) for BS. This meta-analysis indicated that MRI was better than choline PET/CT and BS on a per-patient basis. On a per-lesion analysis, choline PET/CT with the highest DOR and Q* was better than bone SPECT and BS for detecting bone metastases from prostate cancer.  相似文献   

7.

Objectives

To assess the value of secretin during magnetic resonance cholangiopancreatography (MRCP) in demonstrating communication between cystic lesions and the pancreatic duct to help determine the diagnosis of side-branch intraductal papillary mucinous neoplasm (SB-IPMN).

Methods

This is an IRB-approved, HIPAA-compliant retrospective study of 29 SB-IPMN patients and 13 non-IPMN subjects (control) who underwent secretin-enhanced MRCP (s-MRCP). Two readers blinded to the final diagnosis reviewed three randomised image sets: (1) pre-secretin HASTE, (2) dynamic s-MRCP and (3) post-secretin HASTE. Logistic regression, generalised linear models and ROC analyses were used to compare pre- and post-secretin results.

Results

There was no significant difference in median scores for the pre-secretin [reader 1: 1; reader 2: 2 (range -2 to 2)] and post-secretin HASTE [reader 1: 1; reader 2: 1 (range -2 to 2)] in the SB-IPMN group (P?=?0.14), while the scores were lower for s-MRCP [reader 1: 0.5 (range -2 to 2); reader 2: 0 (range -1 to 2); P?=?0.016]. There was no significant difference in mean maximum diameter of SB-IPMN on pre- and post-secretin HASTE, and s-MRCP (P?>?0.05).

Conclusion

Secretin stimulation did not add to MRCP in characterising pancreatic cystic lesions as SB-IPMN.

Key Points

? Magnetic resonance cholangiopancreatography (MRCP) is used to evaluate pancreatic cystic lesions. ? Intraductal papillary mucinous neoplasm (IPMN) is a type of pancreatic cystic neoplasm. ? Secretin administration does not facilitate the diagnosis of IPMN on MRCP.  相似文献   

8.

Introduction

We assessed the validity of “perfusion-metabolism coupling” hypothesis in recurrent glioma with 13N-ammonia (13N-NH3) PET/CT and 18F-fluorodeoxyglucose (18F-FDG) PET/CT.

Methods

Fifty-six consecutive patients (age, 38.8?±?12.1 years; 62.5 % males) with histologically proven and previously treated glioma presenting with clinical suspicion of recurrence were prospectively enrolled and evaluated with 13N-NH3 PET/CT and 18F-FDG PET/CT. PET/CT images were evaluated both qualitatively and semiquantitatively. Tumor to white matter uptake ratio (T/W) and tumor to gray matter uptake ratio (T/G) were calculated and analyzed for both the modalities. A combination of clinico-radiological follow-up, repeated imaging, and biopsy (when available) were considered as the reference standard.

Results

Based on the reference standard, 27/56 patients had recurrence. 13N-NH3 PET/CT and 18F-FDG PET/CT were concordant in 55/56 patients. Overall sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 13N-NH3PET/CT were 77.8, 86.2, 84.0, 80.7, and 82.1 %, respectively, and for 18F-FDG PET/CT were 77.8, 89.7, 87.5, 81.2, and 83.9 %, respectively. There was excellent agreement between results of 13N-NH3 PET/CT and 18F-FDG PET/CT (??=?0.964; P?13N-NH3 PET/CT and 18F-FDG PET/CT were not significantly different between high-grade and low-grade glioma (P?=?1.000). A strong positive correlation was noted between the uptake ratios derived on the two modalities (ρ?=?0.866, P?ρ?=?0.918, P?Conclusion A combination of 13N-NH3 PET/CT and 18F-FDG PET/CT demonstrates that perfusion and metabolism are coupled in recurrent gliomas. These tracers target two different but interrelated aspects of the same pathologic process and can be used as surrogates for each other.  相似文献   

9.

Objective

Our aim was to test the feasibility of blood oxygen level dependent magnetic resonance imaging (BOLD MRI) and dynamic contrast-enhanced (DCE) MRI to monitor periarticular hypoxic/inflammatory changes over time in a juvenile rabbit model of arthritis.

Methods

We examined arthritic and contralateral nonarthritic knees of 21 juvenile rabbits at baseline and days 1,14, and 28 after induction of arthritis by unilateral intra-articular injection of carrageenin with BOLD and DCE MRI at 1.5 Tesla (T). Nine noninjected rabbits served as controls. Associations between BOLD and DCE-MRI and corresponding intra-articular oxygen pressure (PO2) and blood flow [blood perfusion units (BPU)] (polarographic probes, reference standards) or clinical–histological data were measured by correlation coefficients.

Results

Percentage BOLD MRI change obtained in contralateral knees correlated moderately with BPU on day 0 (r?=??0.51, p?=?0.02) and excellently on day 28 (r?=??0.84, p?=?0.03). A moderate correlation was observed between peak enhancement DCE MRI (day 1) and BPU measurements in arthritic knees (r?=?0.49, p?=?0.04). In acute arthritis, BOLD and DCE MRI highly correlated (r?=?0.89, p?=?0.04; r?=?1.0, p?Conclusion The proposed techniques are feasible to perform at 1.5 T, and they hold potential as surrogate measures to monitor hypoxic and inflammatory changes over time in arthritis at higher-strength MRI fields.

Key points

? BOLD and DCE MRI detect interval perisynovial changes in a rabbit knee ? BOLD and DCE MRI act as surrogate markers of physiologic changes in arthritis ? BOLD MRI signal represents oxygen extraction compared with intra-articular PO 2 ? DCE MRI measurements estimate physiologic periarticular vascular properties ? In rabbit knees with acute arthritis, BOLD/DCE MRI highly correlated with histological scores  相似文献   

10.

Purpose

Combined clinical examination and supine chest radiography have shown low accuracy in the assessment of pneumothorax in unstable patients with major chest trauma during the primary survey in the emergency room. The aim of our study was to evaluate the diagnostic accuracy of extended-focused assessment with sonography in trauma (e-FAST), in the diagnosis of pneumothorax, compared with the results of multidetector computed tomography (MDCT) and of invasive interventions (thoracostomy tube placement).

Materials and methods

This was a retrospective case series involving 368 consecutive unstable adult patients (273 men and 95 women; average age, 25 years; range, 16–68 years) admitted to our hospital’s emergency department between January 2011 and December 2012 for major trauma (Injury Severity Score ≥ 15). We evaluated the accuracy of thoracic ultrasound in the detection of pneumothorax compared with the results of MDCT and invasive interventions (thoracostomy tube placement). Institutional review board approval was obtained prior to commencement of this study.

Results

Among the 736 lung fields included in the study, 87 pneumothoraces were detected with thoracic CT scans (23.6 %). e-FAST detected 67/87 and missed 20 pneumothoraces (17 mild, 3 moderate). The diagnostic performance of ultrasound was: sensitivity 77 % (74 % in 2011 and 80 % in 2012), specificity 99.8 %, positive predictive value 98.5 %, negative predictive value 97 %, accuracy 97.2 % (67 true positive; 668 true negative; 1 false positive; 20 false negative); 17 missed mild pneumothoraces were not immediately life-threatening (thickness less than 5 mm).

Conclusions

Thoracic ultrasound (e-FAST) is a rapid and accurate first-line, bedside diagnostic modality for the diagnosis of pneumothorax in unstable patients with major chest trauma during the primary survey in the emergency room.  相似文献   

11.

Purpose

This study compares the quality of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) plans optimized for an Elekta AgilityTM (Elekta, Stockholm, Sweden) multileaf collimator (MLC; leaf width 5 mm) and an Elekta MLCi2 (leaf width 10 mm) for complex target volumes (anal, AC; head and neck, H&N and prostate cancer, PC).

Patients and methods

For plan comparisons, 15 patients who had been treated with IMRT or VMAT using the MLCi2 were selected. For each patient, a retrospective treatment plan using the MLCi2 for the technique not applied was created, as were treatment plans for both techniques using the AgilityTM MLC. Dose–volume histograms (DHVs) for planning target volumes (PTVs) and organs at risk (OARs) were compared. Further parameters relating to dose conformity, dose homogeneity and mean dose (Dmean) to the PTV, compliance with the intended OAR dose criteria and overall dose to normal tissue were analyzed. Verification measurements were performed and optimization and treatment times were compared.

Results

Compared to the MLCi2 plans, the AgilityTM IMRT and VMAT plans show better or equivalent results in terms of PTV dose conformity and homogeneity. Compliance with the intended OAR dose criteria does not differ according to technique or MLC type. Slight differences are shown for dose distributions in OARs and normal tissue. Verification measurements show that all plans fulfill the acceptance criteria of a minimum of 95 % matched dose points for the 3 %/3 mm γ criterion. Optimization times for the VMAT plans increase compared to the IMRT plans, whereas treatment times decrease.

Conclusion

With the MLCi2, treatment of complex target volumes with VMAT was only possible with compromises in terms of target coverage. Using the AgilityTM MLC, even complex target volumes can be treated with VMAT without compromising target coverage or resulting in higher exposure of OARs or normal tissue.  相似文献   

12.
Sonography detected a paraaortic pulsatile tubular mass in a patient 10 years after “stump” nephrectomy, which was subsequently confirmed as a renal artery-renal vein fistula by computed tomography, angiography, and laparotomy.  相似文献   

13.

Objective

IQ-SPECT (Siemens AG, Munich, Germany) is a highly sensitive single-photon-emission computed tomography (SPECT) myocardial perfusion imaging (MPI) system that uses a multifocal collimator. We searched for a suitable protocol for short-time imaging by IQ-SPECT in thallium-201 (Tl-201) MPI by evaluating phantom images and also by comparing human IQ-SPECT images with conventional SPECT images as reference standards.

Methods

We assessed the image quality using the normalized mean square error (NMSE) and drew up count profiles in Tl-201 SPECT images acquired with IQ-SPECT in a phantom study. We also performed Tl-201 stress myocardial SPECT/CT in 21 patients and compared delayed images acquired by using IQ-SPECT with 36 or 17 views per head with images obtained by using conventional SPECT.

Results

The NMSE of SPECT images from IQ-SPECT with 36 views was approximately one-fifth of that with 17 views. The myocardial count profile of images with 17 views was lower than those of images with 36 or 104 views in some regions. Defect scores were significantly lower, and image quality scores higher, in images from conventional SPECT than in those from IQ-SPECT with 17 views. Defect scores and image quality scores were equivalent in images from conventional SPECT and those from IQ-SPECT with 36 views. Agreement with the results of conventional SPECT in terms of coronary artery territory-based defect judgment was the best in IQ-SPECT with 36 views with computed tomography-derived attenuation correction (CTAC): the kappa values for IQ-SPECT with 36 views were 0.76 (without CTAC) and 0.83 (with CTAC), and those for IQ-SPECT with 17 views were 0.62 (without CTAC) and 0.59 (with CTAC). The difference in quantitative tracer uptake between conventional SPECT images and IQ-SPECT images was significantly greater for IQ-SPECT images with 17 views than for those with 36 views.

Conclusions

Scanning with 36 views per head with CTAC may be appropriate for Tl-201 MPI using IQ-SPECT, because it provides images equivalent to those using conventional SPECT.  相似文献   

14.
The value of sonography in the diagnosis of renal masses in a series of 119 consecutive histologically confirmed cases is presented. Sonography correctly identified 92% of the cystic and 90% of the solid renal masses. Causes of incorrect diagnoses included lesions smaller than 2 cm, masses in the left upper pole, diffusely infiltrating urothelial tumors, echogenic fatty lesions (early in our experience), and acute abscesses and hematomas. Angiography in the same series of cases correctly diagnosed 80% of the cystic and 88% of the solid renal masses. Avascular lesions were the main cause for equivocal or incorrect angiographic diagnoses. We conclude that sonography is more definitive than angiography in the diagnosis of avascular masses, while angiography excels when the lesion is vascular or small. Combining the sonographic and angiographic findings allowed accurate diagnosis in over 99% of the cases.  相似文献   

15.

Purpose

The tumour molecular profile predicts the activity of epidermal growth factor receptor (EGFR) inhibitors in non-small-cell lung cancer (NSCLC). However, tissue availability and tumour heterogeneity limit its assessment. We evaluated whether [18F]FDG PET might help predict KRAS and EFGR mutation status in NSCLC.

Methods

Between January 2005 and October 2011, 340 NSCLC patients were tested for KRAS and EGFR mutation status. We identified patients with stage III and IV disease who had undergone [18F]FDG PET/CT scanning for initial staging. SUVpeak, SUVmax and SUVmean of the single hottest tumour lesions were calculated, and their association with KRAS and EGFR mutation status was assessed. A receiver operator characteristic (ROC) curve analysis and a multivariate analysis (including SUVmean, gender, age and AJCC stage) were performed to identify the potential value of [18F]FDG PET/CT for predicting KRAS mutation.

Results

From 102 patients staged using [18F]FDG PET/CT, 28 (27 %) had KRAS mutation (KRAS+), 22 (22 %) had EGFR mutation (EGFR+) and 52 (51 %) had wild-type KRAS and EGFR profiles (WT). KRAS+ patients showed significantly higher [18F]FDG uptake than EGFR+ and WT patients (SUVmean 9.5, 5.7 and 6.6, respectively; p?18F]FDG uptake between EGFR+ patients and WT patients. ROC curve analysis for KRAS mutation status discrimination yielded an area under the curve of 0.740 for SUVmean (p?Conclusion NSCLC patients with tumours harbouring KRAS mutations showed significantly higher [18F]FDG uptake than WT patients, as assessed in terms of SUVpeak, SUVmax and SUVmean. A multivariate model based on age, gender, AJCC stage and SUVmean might be used as a predictive marker of KRAS mutation status in patients with stage III or IV NSCLC.  相似文献   

16.

Background and purpose

Physical 3D treatment planning provides a pool of parameters describing dose distributions. It is often useful to define conformal indices to enable quicker evaluation. However, the application of individual indices is controversial and not always effective. The aim of this study was to design a quick check of dose distributions based on several indices detecting underdosages within planning target volumes (PTVs) and overdosages in normal tissue.

Materials and methods

Dose distributions of 215 cancer patients were considered. Treatment modalities used were three-dimensional conformal radiotherapy (3DCRT), radiosurgery, intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy (IMAT) and tomotherapy. The volumes recommended in ICRU 50 and 83 were used for planning and six conformation and homogeneity indices were selected: CI, CN, CICRU, COV, C?, and HI. These were based on the PTV, the partial volume covered by the prescribed isodose (PI; PTVPI), the treated volume (TVPI), near maximum D2 and near minimum D98. Results were presented as a hexagon—the corners of which represent the values of the indices—and a modified test function F (Rosenbrock’s function) was calculated. Results refer to clinical examples and mean values, in order to allow evaluation of the power of F and hexagon-based decision support procedures in detail and in general.

Results

IMAT and tomotherapy showed the best values for the indices and the lowest standard deviation followed by static IMRT. DCRT and radiosurgery (e.g. CN: IMAT 0.85?±?0.06; tomotherapy 0.84?±?0.06; IMRT 0.83?±?0.07; 3DCRT 0.65?±?0.08; radiosurgery 0.64?±?0.11). In extreme situations, not all indices reflected the situation correctly. Over- and underdosing of PTV and normal tissue could be qualitatively assessed from the distortion of the hexagon in graphic analysis. Tomotherapy, IMRT, IMAT, 3DCRT and radiosurgery showed increasingly distorted hexagons, the type of distortion indicating exposure of normal tissue volumes. The calculated F values correlated with these observations.

Conclusion

An evaluation of dose distributions cannot be based on a single conformal index. A solution could be the use of several indices presented as a hexagonal graphic and/or as a test function.  相似文献   

17.

Purpose

Adrenocortical carcinoma (ACC) is a rare and aggressive malignancy. Limited data are available about on value of 18F-FDG PET/CT in ACC. We evaluated the impact of PET/CT on the management of ACC.

Methods

We performed a retrospective review in patients with ACC who had undergone PET/CT. The impact of PET/CT on the management plan was evaluated by comparing the findings on PET/CT to the findings on contrast-enhanced CT. The sensitivity, specificity, and accuracy of each form of imaging were calculated. The correlations between PET/CT parameters, including maximum standardized uptake value (SUVmax), total lesion glycolysis, and decline in SUVmax after chemotherapy, and clinical outcome were evaluated.

Results

Included in the analysis were 106 patients with 180 PET/CT scans. Of the 106 patients, 7 underwent PET/CT only for initial staging, 84 underwent PET/CT only for restaging, and 15 underwent PET/CT for both initial staging and restaging. PET/CT changed the management plan in 1 of 22 patients (5 %) at initial staging and 9 of 99 patients (9 %) at restaging. In 5 of the patients in whom PET/CT changed the management plan, PET/CT showed response to chemotherapy but contrast-enhanced CT showed stable disease. Sensitivity, specificity, and accuracy were 100 %, 100 %, and 100 % for PET/CT at initial staging; 92.6 %, 100 %, and 96.4 % for CT at initial staging; 98.4 %, 100 %, and 99.5 % for PET/CT at restaging; and 96.8 %, 98.6 %, and 98.0 % for CT at restaging, respectively. No PET/CT parameters were associated with survival at either initial diagnosis or recurrence.

Conclusion

PET/CT findings could substantially change the management plan in a small proportion of patients with ACC. Although lesion detection was similar between PET/CT and CT, PET/CT may be preferred for chemotherapeutic response assessment because it may predict response before anatomic changes are detected on CT.  相似文献   

18.

Purpose

This study evaluated the accuracy of MR sequences [T2-, diffusion-weighted, and dynamic contrast-enhanced (T2WI, DWI, and DCE) imaging] at 3T, based on the European Society of Urogenital Radiology (ESUR) scoring system [Prostate Imaging Reporting and Data System (PI-RADS)] using MR-guided in-bore prostate biopsies as reference standard.

Methods

In 235 consecutive patients [aged 65.7?±?7.9 years; median prostate-specific antigen (PSA) 8 ng/ml] with multiparametric prostate MRI (mp-MRI), 566 lesions were scored according to PI-RADS. Histology of all lesions was obtained by targeted MR-guided in-bore biopsy.

Results

In 200 lesions, biopsy revealed prostate cancer (PCa). The area under the curve (AUC) for cancer detection was 0.70 (T2WI), 0.80 (DWI), and 0.74 (DCE). A combination of T2WI + DWI, T2WI + DCE, and DWI + DCE achieved an AUC of 0.81, 0.78, and 0.79. A summed PI-RADS score of T2WI + DWI + DCE achieved an AUC of 0.81. For higher grade PCa (primary Gleason pattern?≥?4), the AUC was 0.85 for T2WI + DWI, 0.84 for T2WI + DCE, 0.86 for DWI + DCE, and 0.87 for T2WI + DWI + DCE. The AUC for T2WI + DWI + DCE for transitional-zone PCa was 0.73, and for the peripheral zone 0.88. Regarding higher-grade PCa, AUC for transitional-zone PCa was 0.88, and for peripheral zone 0.96.

Conclusion

The combination of T2WI + DWI + DCE achieved the highest test accuracy, especially in patients with higher-grade PCa. The use of ≤2 MR sequences led to lower AUC in higher-grade and peripheral-zone cancers.

Key Points

? T2WI + DWI + DCE achieved the highest accuracy in patients with higher grade PCa ? T2WI + DWI + DCE was more accurate for peripheral- than for transitional-zone PCa ? DCE increased PCa detection accuracy in the peripheral zone ? DWI was the leading sequence in the transitional zone  相似文献   

19.
A patient with a direct arterial fistula into a calyx caused by a stab wound was successfully treated by transcatheter Gelfoam occlusion.  相似文献   

20.

Purpose

We investigated the prognostic value of total metabolic tumour volume (TMTV) in diffuse large B-cell lymphoma (DLBCL).

Methods

TMTV was measured in 114 patients with newly diagnosed DLBCL who underwent 18F-FDG PET/CT at baseline before immunochemotherapy. TMTV was computed by summing the volumes of all lymphomatous lesions after applying the local SUVmax threshold of 41 % using semiautomatic software. Prognostic value was assessed by Kaplan-Meier estimates of progression-free survival (PFS) and overall survival (OS).

Results

Median follow-up was 39 months. Average pretherapy TMTV was 509?±?568 cm3. The 3-year estimates of PFS were 77 % in the low metabolic burden group (TMTV ≤550 cm3) and 60 % in the high metabolic burden group (TMTV >550 cm3, p?=?0.04), and prediction of OS was even better (87 % vs. 60 %, p?=?0.0003). Cox regression showed independence of TMTV for OS prediction (p?=?0.002) compared with other pretherapy indices of tumour burden, such as tumour bulk and the International Prognostic Index.

Conclusion

Pretherapy TMTV is an independent predictor of outcome in patients with DLBCL.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号