首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The aim of the present study was to evaluate the diagnostic accuracy and imaging patterns of colour Doppler ultrasonography (US) and compare it with grayscale US, 99m-Tc methoxyisobutylisonitrile (MIBI) scans, and combined US and MIBI scans in the preoperative diagnosis of parathyroid adenomas in patients with primary hyperparathyroidism (pHPT). From June 2007 to June 2011, 36 consecutive patients (seven men and 29 women) with pHPT underwent grayscale US, colour Doppler ultrasonography (CDUS), and 99m-Tc MIBI scans prior to parathyroidectomy with traditional unilateral neck dissection. All 36 patients with pHPT underwent parathyroidectomy at our university hospital. According to histopathology results, the sensitivity, specificity, and accuracy of MIBI and US scan were 88%, 94%, and 91%, and 70%, 100%, and 85%, respectively. The overall sensitivity and specificity of combined US and MIBI was 97% and 100% respectively. The overall sensitivity, specificity, and accuracy of CDUS in the correct diagnosis of parathyroid adenoma were 97%, 100%, and 98.6%, respectively. The sensitivity and specificity of US in the detection of parathyroid adenoma and differentiating it from other cervical masses reached up to 97% and 100%, respectively, by combining CDUS with grayscale evaluations of parathyroid adenoma.  相似文献   

2.
Aim of the workTo assess serum amyloid A (SAA) level and study its relation to musculoskeletal ultrasound (MSUS) findings and to clinical disease activity indices in rheumatoid arthritis (RA) patients.Patients and methods60 RA patients and 60 matched controls were enrolled. Disease activity score-C-reactive protein (DAS-28-CRP) and simplified disease activity index (SDAI) and clinical disease activity Index (CDAI) were determined. MSUS evaluation was done using 12 -joint power Doppler ultrasound (PDUS) score. SAA was analyzed using an enzyme-linked immunosorbent assay.ResultsSAA levels were highly significant in patients (35.1 ± 3.6 mg/l) than in controls (1.6 ± 0.12 mg/l)(p < 0.001). There was significantly higher SAA level among steroid users (56.7 %)(p = 0.001) and a lower level among leflunomide users (30 %)(p = 0.04). SAA and PDUS significantly increased in patients with low disease activity (n = 13) compared to those in remission (n = 10)(p < 0.001). SAA significantly correlated with disease duration (p = 0.004), morning stiffness duration, swollen joint count, tender joint count, rheumatoid factor, anti-cyclic citrullinated peptide, DAS-28-CRP, SDAI, CDAI, erythrocyte sedimentation rate, CRP and total 12-joint PDUS score (p < 0.001). The highest discriminatory ability of active RA and remission was attributed to the combination of SAA, PDUS and CRP (accuracy = 96.7 %, AUC = 0.99; sensitivity 96 % and specificity 100 %).ConclusionRA patients have a significantly increased level of SAA which indicates a key pathogenic role in the disease. SAA level is a potentially effective biomarker in the assessment of disease activity in RAand allied to PDUS. Combining SAA, PDUS and CRP provide the highest sensitivity and specificity in discrimination of active RA from remission.  相似文献   

3.
OBJECTIVE: To assess the value of gray-scale ultrasound (US), color Doppler ultrasound (CDUS), contrast-enhanced CDUS, and magnetic resonance imaging (MRI) in the diagnostic evaluation of the hands in patients with remitting seronegative symmetrical synovitis with pitting edema (RS3PE). METHODS: Eight patients (5 men, 3 women; mean +/- SD age 69.3 +/- 7.2 years) with clinical diagnosis of RS3PE syndrome underwent US, CDUS, contrast-enhanced CDUS, and MRI. US was performed with a linear array transducer operating at 12 MHz. The US contrast agent (SHU 508; Levovist, Schering, Germany) was intravenously infused in a concentration of 300 mg/ml at a rate of 1 ml/minute. RESULTS: All patients showed symmetric subcutaneous edema and synovitis of tendons and finger joints on both US and MRI. Vascularity was detected subcutaneously in tendon sheaths and in the joint synovia on CDUS and MRI. Detection of increased vascularity was improved after contrast administration compared with unenhanced CDUS (P < 0.01). CONCLUSION: Ultrasound, CDUS, contrast-enhanced CDUS, and MRI are valuable tools in the diagnostic evaluation of involved anatomic structures in patients with RS3PE. Contrast-enhanced CDUS is superior to CDUS in assessment of inflammatory edema, effusion, and synovitis.  相似文献   

4.
Background:Computer-aided detection (CAD) system for accurate and automated prostate cancer (PCa) diagnosis have been developed, however, the diagnostic test accuracy of different CAD systems is still controversial. This systematic review aimed to assess the diagnostic accuracy of CAD systems based on magnetic resonance imaging for PCa.Methods:Cochrane library, PubMed, EMBASE and China Biology Medicine disc were systematically searched until March 2019 for original diagnostic studies. Two independent reviewers selected studies on CAD based on magnetic resonance imaging diagnosis of PCa and extracted the requisite data. Pooled sensitivity, specificity, and the area under the summary receiver operating characteristic curve were calculated to estimate the diagnostic accuracy of CAD system.Results:Fifteen studies involving 1945 patients were included in our analysis. The diagnostic meta-analysis showed that overall sensitivity of CAD system ranged from 0.47 to 1.00 and, specificity from 0.47 to 0.89. The pooled sensitivity of CAD system was 0.87 (95% CI: 0.76–0.94), pooled specificity 0.76 (95% CI: 0.62–0.85), and the area under curve (AUC) 0.89 (95% CI: 0.86–0.91). Subgroup analysis showed that the support vector machines produced the best AUC among the CAD classifiers, with sensitivity ranging from 0.87 to 0.92, and specificity from 0.47 to 0.95. Among different zones of prostate, CAD system produced the best AUC in the transitional zone than the peripheral zone and central gland; sensitivity ranged from 0.89 to 1.00, and specificity from 0.38 to 0.85.Conclusions:CAD system can help improve the diagnostic accuracy of PCa especially using the support vector machines classifier. Whether the performance of the CAD system depends on the specific locations of the prostate needs further investigation.  相似文献   

5.
BackgroundSeveral studies evaluated the current guideline of the American Society for Gastrointestinal Endoscopy (ASGE) and reported only suboptimal accuracy. This study evaluated the diagnostic performance of the ASGE guideline based on computed tomography (CT) and role of endoscopic ultrasonography (EUS) and magnetic resonance cholangiopancreatography (MRCP) in patients with suspected choledocholithiasis but negative CT finding.MethodsPatients with suspected choledocholithiasis undergoing ERCP between January 2016 and January 2017 were retrospectively analyzed. All patients underwent CT to detect choledocholithiasis. EUS or MRCP was performed when the CT scan showed negative findings. Patients were classified into the high and intermediate-risk groups, based on predictors from the ASGE criteria.ResultsOf 583 patients with suspected choledocholithiasis, 340 (58.3%) had stones on ERCP (65.9% in the high-risk group and 40.6% in the intermediate-risk group). The accuracy of ASGE guideline for CT was 63.98% (79.12% sensitivity, 42.80% specificity) and 36.02% (20.88% sensitivity, 57.20% specificity) in the high-risk and intermediate-risk groups, respectively. In 103 patients in the high-risk group underwent both CT and US, the accuracy of CT was higher than that of US for detecting choledocholithiasis (78.64% vs. 53.40%), with a significant difference in area under the curve (AUC) (0.78 vs. 0.59, P < 0.001). Of 339 with negative CT finding, the accuracy of EUS was higher than that of MRCP (90.91% vs. 82.76%), but with no significant difference in AUC (0.91 vs. 0.83, P = 0.347).ConclusionsCT-based ASGE guideline showed superior diagnostic performance than US for predicting choledocholithiasis. The diagnostic options, EUS or MRCP, with negative CT finding showed comparable performance. Therefore, the diagnostic modality should be selected based on availability, experience, cost, and contraindications.  相似文献   

6.
ObjectivesDepression is under-reported and under-identified by the healthcare professionals. Geriatric depression scale (GDS) is one of the most commonly used instruments for screening the older adults for depression. The current review was done to determine the diagnostic accuracy of various forms of GDS for screening of depression among older adults.MethodsWe conducted systematic search in various databases like Medline, Cochrane library, Sciencedirect and Google Scholar from inception till May 2019. Quality of trials was assessed by Quality Assessment of Diagnostic Accuracy Studies-2 tool. We performed bivariate meta-analysis to obtain the pooled sensitivity, specificity, positive, negative likelihood ratio and diagnostic odds ratio for each of the GDS forms.ResultsTotally 53 studies with 17,018 participants were included in the review. We found the pooled sensitivity and specificity of GDS 30 to be 82 % and 76 % with near higher diagnostic accuracy (AUC = 0.85). GDS 15 had pooled sensitivity and specificity of 86 % and 79 % with higher diagnostic accuracy (AUC = 0.90). GDS 10 had pooled sensitivity and specificity of 87 % and 75 % with AUC = 0.83. Our study found GDS 4 to have sensitivity of 74 % with specificity of 71 %. All the four forms of GDS belonged to right lower quadrant of LR scatter-gram indicating neither confirmation nor exclusion.ConclusionCurrent study found that all the forms of GDS are highly useful for detecting depression among elderly with higher sensitivity and specificity. The diagnostic performance was much better for shorter forms of GDS such as GDS 15 and GDS 10 when compared to GDS 30.  相似文献   

7.
BackgroundThe influence of extensive coronary calcifications on the diagnostic and prognostic value of coronary computed tomography angiography–derived fractional flow reserve (FFRCT) has been scantily investigated.ObjectivesThe purpose of this study was to investigate the diagnostic and short-term role of FFRCT in chest pain patients with Agatston score (AS) >399.MethodsThis was a prospective multicenter study of 260 stable patients with suspected coronary artery disease (CAD) and AS >399. FFRCT was measured blinded by an independent core laboratory. All patients underwent invasive coronary angiography (ICA) and FFR if indicated. The agreement of FFRCT ≤0.80 with hemodynamically significant CAD on ICA/FFR (≥50% left main or ≥70% epicardial artery stenosis and/or FFR ≤0.80) was assessed. Patients undergoing FFR had colocation FFRCT measured, and the lowest per-patient FFRCT was registered in all patients. The association among per-patient FFRCT, coronary revascularization, and major clinical events (all-cause mortality, myocardial infarction, or unstable angina hospitalization) at 90-day follow-up was evaluated.ResultsMedian age and AS were 68.5 years (IQR: 63-74 years) and 895 (IQR: 587-1,513), respectively. FFRCT was ≤0.80 in 204 patients (78%). Colocation FFRCT (n = 112) showed diagnostic accuracy, sensitivity, and specificity to identify hemodynamically significant CAD of 71%, 87%, and 54%. The area under the receiver-operating characteristics curve (AUC) was 0.75. When using the lowest FFRCT (n = 260), per-patient accuracy, sensitivity, and specificity were 57%, 95%, and 32%, respectively. The AUC was 0.84. A total of 85 patients underwent revascularization, and FFRCT was ≤0.80 in 96% of these. During follow-up, major clinical events occurred in 3 patients (1.2%), all with FFRCT ≤0.80.ConclusionsMost patients with AS >399 had FFRCT ≤0.80. Using ICA/FFR as the reference revealed a moderate diagnostic accuracy of colocation FFRCT. Compared with the lowest per-patient FFRCT, colocation FFRCT measurement improved diagnostic accuracy and specificity. The 90-day follow-up was favorable with few coronary revascularizations and no major clinical events occurring in patients with FFRCT >0.80. (Use of FFR-CT in Stable Intermediate Chest Pain Patients With Severe Coronary Calcium Score [FACC]; NCT03548753)  相似文献   

8.
AimTo evaluate sensitivity and specificity of the micro-controlled thermal stimulator (MTS) for detecting pathological changes in fine fiber of neuropathy patients with DM.MethodsA diagnostic accuracy study including 84 patients, aged 15–75 years was conducted. A patient’s foot was subjected to dermatological, musculoskeletal, vascular, and neurological evaluations. The latter was performed through the perception of a sharp touch with a toothpick (pinprick), thermal sensitivity (cold and hot temperature sensations measured using Diapason Handle and MTS, respectively), vibratory sensitivity (128 Hz Diapason Handle), 10 g Semmes-Weinstein monofilament, and a reflex test. Statistical analyses were performed using Stata® software version 13.0. The sensitivity, specificity, positive and negative predictive values, likelihood ratios, AUC, Kappa index, and accuracy of the diagnostic instruments were evaluated.ResultsOf the 84 volunteers, 66.7% were female, with an average age of 54 years. We observed that 17% of the total patients were positive for pain sensations in the foot, 13% for cold-temperature sensations, and 21% for hot-temperature sensations. The MTS (hot temperature) obtained 97.6% sensitivity and 90% specificity, agreeing on 87.5% (Kappa index) with the Diapason Handle (cold temperature) (AUC > 0.937; p < 0.05).ConclusionMTS is an accurate, sensitive, and specific instrument for the evaluation of diabetic neuropathy as compared with the tuning fork as the standard method and, consequently, it could be of help for the early diagnosis of diabetic neuropathy.  相似文献   

9.
《Pancreatology》2002,2(1):61-68
Aim: To investigate the diagnostic accuracy of power Doppler ultrasonography (US) in assessing the vascular invasion by pancreatic cancer. Methods: A prospective study of 40 consecutive patients with pancreatic cancer (head 35, body 5) was performed. All patients underwent surgery. The relationships between tumor and each vessel were classified into four types according to the closest circumferential contact of the tumor with the vessel. A type 0 indicated no contact; type 1 indicated less than one third contact; type 2 indicated one third to 99% contact, and type 3 indicated encasement. Vascular invasion was diagnosed in types 2 and 3. The diagnostic accuracy was evaluated in the portal vein and in the splanchnic arteries (celiac artery, common hepatic artery, and superior mesenteric artery). The power Doppler US findings were confirmed by the operative findings. The results of power Doppler US were compared with those of CT scan and angiography. Results: Portal vein invasion was confirmed in resected specimens in 23 cases and by operative findings in 5 cases. For the diagnosis of portal vein invasion, sensitivity, specificity, and overall accuracy of power Doppler US were, respectively, 79.3, 90.9, and 82.5%. The respective values were 79.3, 100, and 85% for CT and 72.4, 81.8, and 75% for angiography. For the diagnosis of arterial invasion, sensitivity, specificity, and overall accuracy of power Doppler US were 80, 92, and 90%, respectively. The corresponding values were 47, 88, and 73% for CT and 47, 100, and 80% for angiography. Conclusion: Power Doppler US proved to be useful for the diagnosis of vascular invasion by pancreatic cancer.  相似文献   

10.
Background: There is still a debate on which imaging method is the best to diagnose cesarean scar pregnancy (CSP). Accordingly, this study aimed to analyze the diagnostic performance of magnetic resonance imaging (MRI) and ultrasonography (US) on the detection of CSP based on current evidence in the literature.Methods:PubMed, Embase, Cochrane, Chinese Biomedical Documentation Service System, WanFang, and China National Knowledge Infrastructure databases were searched up to June 2020. The included studies were all comparisons of MRI and US in the diagnosis of CSP that adopted postoperative histological examination as the reference standard. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and area under the summary receiver operating characteristic curve (AUC) were calculated for MRI and US.Results:Thirteen studies were included, with a total sample size of 948 patients. The pooled sensitivity, specificity, PLR, NLR, and AUC of MRI in diagnosing CSP were 0.93 (95% CI, 0.91-0.95), 0.83 (95% CI, 0.75-0.89), 5.46 (95% CI, 3.70-8.05), 0.08 (95% CI, 0.06-0.11), and 0.96 (95% CI, 0.93-0.97), respectively; for US they were 0.84 (95% CI, 0.79-0.88), 0.73 (95% CI, 0.62-0.81), 3.06 (95% CI, 2.22-4.21), 0.23 (95% CI, 0.18-0.28), and 0.86 (95% CI, 0.83-0.89), respectively.Conclusion:We found that both MRI and US effectively diagnosed CSP; however, MRI had a higher diagnostic performance in detecting CSP than US.  相似文献   

11.
OBJECTIVE: A prospective study was performed to assess the usefulness of contrast-enhanced color Doppler ultrasound (CDUS) in the evaluation of intraarticular vascularization of finger joints in patients with rheumatoid arthritis (RA). METHODS: We investigated 198 finger joints in 46 patients with RA, and 80 finger joints in 10 healthy volunteers. Joints with varying levels of clinical activity of inflammation were classified as being active, moderately active, or inactive. CDUS was performed with a high-frequency multi-D linear array transducer. A microbubble-based ultrasound (US) contrast agent (Levovist; Schering, Berlin, Germany) was intravenously infused. Doppler findings were rated on the basis of both unenhanced and contrast-enhanced CDUS images. RESULTS: Healthy joints showed no intraarticular vascularization on either unenhanced or contrast-enhanced CDUS. Unenhanced CDUS detected intraarticular vascularization in 7 (8%) of 83 inactive joints, in 31 (52%) of 60 moderately active joints, and in 32 (58%) of 55 active joints. Contrast-enhanced CDUS detected intraarticular vascularization in 41 (49%) of 83 joints with inactive RA, in 59 (98%) of 60 joints with moderately active RA, and in all 55 joints with active RA. Detection of intraarticular vascularization was improved by administration of the microbubble-based US contrast agent (P < 0.001). Contrast-enhanced CDUS demonstrated differences in intraarticular vascularization between joints with inactive RA and those with active RA (P < 0.001), between joints with inactive RA and those with moderately active RA (P < 0.001), and between joints with moderately active RA and those with active RA (P < 0.001). CONCLUSION: The use of a microbubble-based US contrast agent significantly improved the detection of intraarticular vascularization in the finger joints of patients with RA. This technique seems to be a useful adjunct in the assessment of disease activity.  相似文献   

12.

Objective

To assess the intra‐ and interobserver reproducibility of musculoskeletal ultrasonography (US) in detecting inflammatory shoulder changes in patients with rheumatoid arthritis, and to determine the agreement between US and the Shoulder Pain and Disability Index (SPADI) and the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire, using magnetic resonance imaging (MRI) as a gold standard.

Methods

Eleven rheumatologists investigated 10 patients in 2 rounds independently and blindly of each other by US. US results were compared with shoulder function tests and MRI.

Results

The positive and negative predictive values (NPVs) for axillary recess synovitis (ARS) were 0.88 and 0.43, respectively, for posterior recess synovitis (PRS) were 0.36 and 0.97, respectively, for subacromial/subdeltoid bursitis (SASB) were 0.85 and 0.28, respectively, and the NPV for biceps tenosynovitis (BT) was 1.00. The intraobserver kappa was 0.62 for ARS, 0.59 for PRS, 0.51 for BT, and 0.70 for SASB. The intraobserver kappa for power Doppler US (PDUS) signal was 0.91 for PRS, 0.77 for ARS, 0.94 for SASB, and 0.53 for BT. The interobserver maximum kappa was 0.46 for BT, 0.95 for ARS, 0.52 for PRS, and 0.61 for SASB. The interobserver reliability of PDUS was 1.0 for PRS, 0.1 for ARS, 0.5 for BT, and 1.0 for SASB. P values for the SPADI and DASH versus cuff tear on US were 0.02 and 0.01, respectively; all other relationships were not significant.

Conclusion

Overall agreements between gray‐scale US and MRI regarding synovitis of the shoulder varied considerably, but excellent results were seen for PDUS. Measures of shoulder function have a poor relationship with US and MRI. Improved standardization of US scanning technique could further reliability of shoulder US.  相似文献   

13.
To investigate the complex appearance of vascularity of sacroiliac joint (SIJ) in ankylosing spondylitis. Sixty-eight patients and 35 controls were included in the study. Blood flow was examined at the SIJ by using color Doppler ultrasonography (CDUS). The location of color flow signs and flow pattern were observed. Arteries do not present reversed phase in diastolic phase on pulse Doppler sonography, and if they were found inside and around the SIJ, the resistive index (RI) was measured. In active AS patients, the region of SIJ presented increased vascularization greater than those in inactive AS (P = 0.001) and the controls (P = 0.001). There are three different spectral Doppler tracings: arterial flow (RI < 1), arterial flow representing reversed phase in diastolic phase on spectral Doppler sonography and venous flow. Besides arterial flow signs, most of color flow signs presented venous flow in active AS. Significant increases in a number of venous flow signs in active AS cases (P < 0.001) were observed. In most cases, two or more different flow patterns presented in a region very close to the location of SIJ. In addition, a different vascularization was observed. Abnormal vascularization at the sacroiliac joints can be detected by CDUS. The vascularization in SIJ presented complex appearance, which increases the difficulties of CDUS examination. Venous blood flow in the assessment of active AS merits further study.  相似文献   

14.
BackgroundQuantitative flow ratio (QFR) is a technology to evaluate the coronary stenosis significance on 3-dimensional quantitative coronary angiography. The aim of this study is to evaluate and compare the QFR versus fractional flow reserve (FFR) and/or instantaneous free-wave ratio (iFR) in a US population with a fair African American population representation.Methods and resultsThis was a retrospective, observational and single-center study that enrolled 100 patients who underwent coronary angiography. The diagnostic performance of QFR in terms of sensitivity was 0.80 (95%CI 0.64–0.97) and specificity was 0.95 (95% CI 0.90–1.00), the positive predictive value (PPV) was 0.83 (0.68–0.98), while the negative predictive value (NPV) was 0.94 (0.88–0.99). The overall accuracy was 0.91 and area under the curve (AUC) was 0.92 (95% CI 0.87–0.97).The R-squared was 0.54 and the Bland-Altman plot showed a bias of 0.0016 (SD 0.063) and limits of agreement (LOA): Upper LOA 0.13 and Lower LOA −0.12. In African Americans (n = 33), accuracy, AUC, sensitivity, specificity (94%; 0.90 [0.80–1.00]; 0.90 [0.71–1.00]; 0.96 [0.87–1.00], respectively) were better than those for the overall population.ConclusionsIn a US-based representative population, vessel QFR accuracy and agreement with FFR as reference is high. Diagnostic performance of QFR in African Americans is also excellent.  相似文献   

15.
Background:Computed tomography (CT) is the current gold standard for the detection of pulmonary nodules but has high radiation burden. In contrast, many radiologists tried to use magnetic resonance imaging (MRI) to replace CT because MRI has no radiation burden associated. Due to the lack of high-level evidence of comparison of the diagnostic accuracy of MRI versus CT for detecting pulmonary nodules, it is unknown whether CT can be replaced successfully by MRI. Therefore, the aim of this study was to compare the diagnostic accuracy of MRI versus CT for detecting pulmonary nodules.Methods:Electronic databases PubMed, EmBase, and Cochrane Library were systematically searched from their inception to September 2017 to identify studies in which CT/MRI was used to diagnose pulmonary nodules. According to true positive, true negative, false negative, and false positive extracted from the included studies, we calculate the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and area under the curve (AUC) using Stata version 14.0 software (STATA Corp, TX).Results:A total of 8 studies involving a total of 653 individuals were included. The pooled sensitivity, specificity, PLR, NLR, and AUC were 0.91 (95% confidence interval [CI]: 0.80–0.96), 0.76 (95%CI: 0.58–0.87), 3.72 (95%CI: 2.05–6.76), 0.12 (95%CI: 0.06–0.27), and 0.91 (95%CI: 0.88–0.93) for MRI respectively, while the pooled sensitivity, specificity, PLR, NLR, and AUC for CT were 1.00 (95%CI: 0.95–1.00), 0.99 (95%CI: 0.78–1.00), 79.35 (95%CI: 3.68–1711.06), 0.00 (95%CI: 0.00–0.06), and 1.00 (95%CI: 0.99–1.00), respectively. Further, we compared the diagnostic accuracy of CT versus MRI and found that compared with MRI, CT shows statistically higher sensitivity (odds ratio [OR] for MRI vs CT: 0.91; 95%CI: 0.85–0.98; P value .010), specificity (OR: 0.82; 95%CI: 0.69–0.97; P value .019), PLR (OR: 0.29; 95%CI: 0.10–0.83; P value 0.02), AUC (OR: 0.91; 95%CI: 0.89–0.94; P value < .001), and lower NLR (OR: 8.72; 95%CI: 1.57–48.56; P value .013).Conclusion:Our study suggested both CT and MRI have a high diagnostic accuracy in diagnosing pulmonary nodules, while CT was superior to MRI in sensitivity, specificity, PLR, NLR, and AUC, indicating that in terms of the currently available evidence, MRI could not replace CT in diagnosing pulmonary nodules.  相似文献   

16.
《Microvascular research》2012,83(3):410-415
ObjectiveTo assess morphology and blood flow of the proper palmar digital arteries (PPDA) by Color Doppler Ultrasonography (CDUS) and its relationship with nailfold videocapillaroscopy (NVC), skin blood perfusion and digital arteries pulsatility of hands in SSc patients and healthy controls.MethodsCDUS, NVC, Laser Doppler Perfusion Imaging (LDPI) and photoplethysmography (PPG) were performed in 36 systemic sclerosis (SSc) patients and 20 healthy controls.ResultsCDUS was pathologic in 69% of patients with SSc and in none of healthy controls (p < 0.0001). SSc patients with low vascular damage (early capillaroscopic pattern) have a normal morphology of PPDA, but the blood flow, evaluated by peak systolic velocity (PSV) and end diastolic velocity (EDV), is reduced and vascular resistance, measured by resistive index (RI) and pulsatility index (PI), increased. At this stage the LDPI mean perfusion and digital artery pulsatility, evaluated by PPG, were reduced. The US changes appear with microvasculare damage progression (active and late capillaroscopic patterns), while the PPDA blood flow progressively decreases (PSV and EDV decreased, RI and PI increased). The macrovascular damage correlates with disease duration. Anti-topoisomerase I represents an independent predictive factor for macrovascular damage. We not observed any association between digital ulcer history, pulmonary fibrosis and US findings.ConclusionPPDA blood flow dysfunction is already present in early disease. Structural macrovascular damage progresses with worsening of SSc microangiopathy.  相似文献   

17.
Background:We aim to evaluate the efficiency of Raman spectroscopy (RS) in diagnosing suspected patients with intrahepatic cholangiocarcinoma (ICC), manifested by diagnostic sensitivity, specificity, and accuracy.Methods:We will research widely the articles concerning the use of RS in ICC through authenticated database including PubMed/Medline, EMBASE, Web of Science, Ovid, Web of Knowledge, Cochrane Library, and CNKI between January 2012 and November 2020, retrieving at least 1500 spectra with strict criteria. This study will be carried out in accordance to Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. We are going to summarize the test performance using random effects models.Results:Based on the pooled sensitivity, specificity, and diagnostic accuracy, we intend to provide the relative diagnostic efficiency in ICC through RS.Conclusion:Through this systematic review and meta-analysis, we intend to provide the pooled sensitivity, specificity and diagnostic accuracy of RS in the diagnosis of suspected ICC. Other parameters like positive likelihood ratios (LR), negative LR, diagnostic odds ratio (DOR), and area under curve (AUC) of the summary receiver operating characteristics (SROC) curve will also be calculated and related figures will be drawn to help illustrate the efficacy of RS in the diagnosis of ICC.  相似文献   

18.
OBJECTIVE: To evaluate the sensitivity to change of power Doppler ultrasound (PDUS) assessment of joint inflammation and the predictive value of PDUS parameters in disease activity and radiologic outcome in patients with early rheumatoid arthritis (RA). METHODS: Forty-two patients with early RA who started therapy with disease-modifying antirheumatic drugs underwent blinded sequential clinical, laboratory, and ultrasound assessment at baseline, 3 months, 6 months, and 1 year and radiographic assessment at baseline and 1 year. For each patient, 28-joint Disease Activity Score (DAS28) was recorded at each visit. The presence of synovitis was investigated in 28 joints using gray-scale ultrasonography and intraarticular power Doppler signal. Active synovitis was defined as intraarticular synovitis detected with power Doppler signal. The ultrasound joint count for active synovitis and an overall joint index for power Doppler signal were calculated. Sensitivity to change of PDUS variables was assessed by estimating the smallest detectable difference (SDD) from the intraobserver variability. RESULTS: The SDD for ultrasound joint count for active synovitis and ultrasound joint index for power Doppler signal was lower than mean changes from baseline to 3 months, 6 months, and 1 year. Time-integrated values of PDUS parameters demonstrated a highly significant correlation with DAS28 after 1 year (r = 0.63, P < 0.001) and a stronger correlation with radiographic progression (r = 0.59-0.66, P < 0.001) than clinical and laboratory parameters (r < 0.5). CONCLUSION: PDUS is a sensitive and reliable method for longitudinal assessment of inflammatory activity in early RA. PDUS findings may have a predictive value in disease activity and radiographic outcome.  相似文献   

19.

Objective

To evaluate and improve the reliability of power Doppler ultrasonography (PDUS) for detecting and scoring enthesitis in patients with spondylarthitis, using a 3‐step procedure.

Methods

In the first step, we evaluated the reliability of 5 sonographers by bilaterally scanning 5 entheses twice in 5 patients. In the second step, starting from disagreements observed during the first step, we established consensus guidelines. The sonographers' implementation was further evaluated in 2 reliability exercises: one on 60 PDUS enthesitis images and the other by scanning 5 new patients. In the third step, we performed a final reliability evaluation of 5 additional patients after 1 year. Kappa coefficients (κ) as well as variance component analysis (VCA) and generalizability theory (GT) were used to assess reliability.

Results

The initial intra‐ and interobserver reliability were poor, especially for detecting and scoring Doppler signal. VCA and GT showed that most variability was accounted for by interaction between sonographer and enthesis. Implementation of consensus guidelines was associated with a significant improvement in Doppler reliability between the first and second steps (mean interobserver κ increased from 0.13 to 0.51 for binary Doppler scoring in patients; P < 0.005), which persisted in the third step (mean interobserver κ = 0.57). The high GT coefficients reached in the last steps supported such improvement.

Conclusion

The 3‐step procedure used in this study to standardize PDUS technique was associated with a significant improvement in interobserver reliability for detecting enthesitis in spondylarthritis patients. Such an approach can be useful to standardize PDUS assessment of musculoskeletal disorders.  相似文献   

20.
Background and objectiveEUS-FNA of pancreatic lesion has been put into clinical use widely in many centers. The present meta-analysis was conducted to study the diagnostic role of EUS-FNA in pancreatic cancer.MethodsA comprehensive review of study on the precision of EUS-FNA in the diagnosis of pancreatic cancer. A random effects model was used to pool the sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratio (DOR). A summary receiver-operating characteristic (SROC) was constructed to summarize the overall test performance.ResultsThirty-one articles were eligible for the meta-analysis. The pooled sensitivity, specificity, PLR, NLR and DOR of EUS-FNA in the diagnosis of pancreatic cancer were 0.89 (95% CI: 0.88–0.90), 0.96 (95% CI: 0.95–0.97), 16.88 (95% CI: 10.63–26.79), 0.13 (95%CI: 0.10–0.16) and 150.80 (95%CI: 95.94–237.03) respectively. In subgroup meta-analysis of the prospective studies, the pooled sensitivity, specificity, PLR, NLR and DOR were 0.91 (95% CI: 0.90–0.93), 0.94 (95% CI: 0.91–0.96), 11.19 (95% CI: 6.36–19.69), 0.10 (95% CI: 0.07–0.15) and 125.22 (62.37–251.41). The area under the curve (AUC) was 0.97, indicating a good performance of overall accuracy.ConclusionEUS-FNA has the high sensitivity and specificity in differentiating pancreatic cancer. Moreover, it is also a safe diagnostic modality with little complications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号