首页 | 本学科首页   官方微博 | 高级检索  
     


Selective determination of tenofovir in human plasma by LC-MS-MS method
Authors:Xiang Xie  Rui Zhou  Peigen Zhou  Peng Yu  Feng Gao
Abstract:In the present study, we developed and validated a selective, specific and sensitive liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS/MS) method for the determination of tenofovir in human plasma. Entecavir was used as an internal standard, and plasma samples were prepared by solid-phase extraction performed on Phenomenex Strata cartridges (30 mg). The mobile phase consisted of 10 mM ammonium acetate in water and methanol (60:40, v/v). The chromatographic separation was performed isocratically on a Phenomenex C18 (4.6 mm×150 mm, 5 μm), and analytes were analyzed in multiple reaction monitoring (MRM) mode with positive electrospray ionization (ESI) interface using the respective [M+H]+ ions, m/z 288.2→m/z 176.1 for tenofovir and m/z 278.1→m/z 152 for entecavir. The calibration curve (r2 = 0.9962) of tenofovir was established within the range of 4.096–1000 μg/L. The intra- and inter-day precisions were less than 10%. This validated method was successfully applied to a pharmacokinetic study in 12 healthy Chinese volunteers after the oral administration of tenofovir disoproxil fumarate.
Keywords:LC-ESI-MS/MS  Tenofovir  Pharmacokinetic  Plasma  
点击此处可从《中国药学》浏览原始摘要信息
点击此处可从《中国药学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号