首页 | 本学科首页   官方微博 | 高级检索  
     

不同屈光状态儿童应用盐酸环喷托酯滴眼后1h内等效球镜度与瞳孔直径达到稳定所需时间及变化幅度的相关影响因素
引用本文:金成成,裴茹霞,杜蓓,王希莲,刘桂华,金楠,韩丁,刘琳,魏瑞华. 不同屈光状态儿童应用盐酸环喷托酯滴眼后1h内等效球镜度与瞳孔直径达到稳定所需时间及变化幅度的相关影响因素[J]. 眼科新进展, 2020, 0(10): 946-951. DOI: 10.13389/j.cnki.rao.2020.0213
作者姓名:金成成  裴茹霞  杜蓓  王希莲  刘桂华  金楠  韩丁  刘琳  魏瑞华
作者单位:300384 天津市,天津医科大学眼科医院、眼视光学院、眼科研究所,天津市眼科学与视觉科学国际联合研究中心(金成成,裴茹霞,杜蓓,刘桂华,金楠,韩丁,刘琳,魏瑞华);300400 天津市,天津市北辰医院眼科(王希莲)
基金项目:天津市科技计划项目基金资助(编号:17ZXHLSY00070);
摘    要:目的探讨不同屈光状态儿童应用盐酸环喷托酯(cyclopentolate hydrochloride,CH)滴眼后1 h内等效球镜度(spherical equivalent,SE)与瞳孔直径(pupil diameter,PD)达到稳定所需时间及变化幅度的相关影响因素。方法选取2019年9月首次于天津医科大学眼科医院视光门诊就诊,拟诊断为屈光不正,需要进行睫状肌麻痹验光的患儿56例100眼。根据末次测量的SE将患儿分为3组:(1)近视组(40眼):SE <-0.50 D;(2)正视组(29眼):-0.50 D≤SE≤+0.50 D;(3)远视组(31眼):SE>+0.50 D。在第一滴CH滴眼前和滴眼后1 h内,由同一名研究人员分别应用自动电脑验光仪(精度0.13 D)和红外瞳孔计(精度0.01 mm)监测SE和PD的动态变化,每5 min监测1次,共计13次。通过重复测量方差分析确定不同屈光状态组SE与PD达到稳定所需时间;通过方差分析比较不同屈光状态组SE和PD变化幅度差异;通过Pearson双变量相关分析寻找SE及PD变化幅度的相关影响因素。结果近视组在第一滴CH滴眼...

关 键 词:盐酸环喷托酯  等效球镜度  瞳孔直径  相关影响因素  儿童

Time to reach stabilization and factors related with changing amplitude of spherical equivalents and pupil diameters during1hour after cycloplegia with cyclopentolate hydrochloride on children in different refractive status
JIN Chengcheng1,PEI Ruxia1,DU Bei1,WANG Xilian2,LIU Guihua1,JIN Nan1,HAN Ding1,LIU Lin1,WEI Ruihua1. Time to reach stabilization and factors related with changing amplitude of spherical equivalents and pupil diameters during1hour after cycloplegia with cyclopentolate hydrochloride on children in different refractive status[J]. Recent Advances in Ophthalmology, 2020, 0(10): 946-951. DOI: 10.13389/j.cnki.rao.2020.0213
Authors:JIN Chengcheng1  PEI Ruxia1  DU Bei1  WANG Xilian2  LIU Guihua1  JIN Nan1  HAN Ding1  LIU Lin1  WEI Ruihua1
Affiliation:1.Tianjin International Joint Research and Development Centre of Ophthalmology and Vision Science,Eye Institute and School of Optometry,Tianjin Medical University Eye Hospital,Tianjin 300384,China2.Department of Ophthalmology,Tianjin Beichen Hospita
Abstract:Objective To determine the time for spherical equivalents (SE) and pupil diameters (PD) to become stable and related factors of the changing amplitude at 1 hour after application of cyclopentolate hydrochloride (CH) to children in different refractive status.Methods A total of 56 patients (100 eyes) with ametropia were selected who were first treated in Optometry Clinic of Tianjin Medical University Eye Hospital in September 2019. According to the final SE, subjects were divided into three groups: (1)myopia group (40 eyes): SE<-0.50 D; (2) emmetropia group (29 eyes): -0.50 D≤SE≤+0.50 D; (3) hyperopia group (31 eyes): SE>+0.50 D. The dynamic changes of SE and PD were monitored 13 times by the same researcher through the autorefractor (with an accuracy of 0.13 D) and infrared pupillometer (with an accuracy of 0.01 mm) every 5 minutes in 1 hour after and before the first drop of CH. Repeated-measure analyses of variance were used to determine the time required for SE and PD to reach stability in different refractive groups. Analyses of variance were conducted to compare the changing amplitude of SE and PD among different refractive groups. Pearson bivariate correlation analyses were utilized to find related factors with the changing amplitude of SE and PD.Results No significant difference was found between the peak value of SE and the value measured 30 minutes after (including 30 minutes) the first drop of CH in myopia group (all P> 0.05), with the difference not more than 0.04 D. No significant difference was found between the peak value of SE and the value measured 30 minutes after (including 30 minutes) the first drop of CH in emmetropia group (all P> 0.05), with the difference not more than 0.13 D. No significant difference was found between the peak value of SE and the value measured 35 minutes after (including 35 minutes) the first drop of CH in hyperopia group (all P> 0.05), with the difference not more than 0.07 D. Totally, the difference between the peak value of SE within 1 hour after the first CH and the SE measured at 35 minutes after the first CH was not more than 0.25 D in 95 eyes (95%). Significant difference was found between the peak value of PD and the value measured within 55 minutes after (including 55 minutes) the first drop of CH in myopia group (all P< 0.05), with no clinical difference (0.07 mm) at 55 minutes. Significant difference was found between the peak value of PD and the value measured within 55 minutes after (including 55 minutes) the first drop of CH in emmetropia group (all P< 0.05), with no clinical difference (0.05 mm) at 55 minutes. Significant difference was found between the peak value of PD and the value measured within 55 minutes after (including 55 minutes) the first drop of CH in hyperopia group (all P< 0.05), with no clinical difference (0.06 mm) at 55 minutes. Totally, the difference between the peak value of PD within 1 hour after the first CH and the PD measured at 55 minutes after the first CH was not more than 0.10 mm in 86 eyes (86%). Pearson bivariate linear correlation analysis showed that the change of SE was negatively correlated with axial length (r=-0.445, P<0.001) and age (r=-0.225, P=0.024), and positively correlated with the final SE (r=0.543, P< 0.001) and initial SE (r=0.297, P=0.003), but not significantly correlated with gender (r=0.113, P=0.262) or intraocular pressure (r=-0.142, P=0.158). The change of PD was negatively correlated with the initial PD (r=-0.583, P<0.001), but not significantly correlated with age (r=-0.008, P=0.933), gender (r=0.005, P=0.957), intraocular pressure (r=-0.139, P=0.167), axial length (r=-0.020, P=0.843) or the final PD (r=-0.003, P=0.979). No serious side effects were observed throughout the study.
Keywords:cyclopentolate hydrochloride   spherical equivalents   pupil diameters   related factors   children
点击此处可从《眼科新进展》浏览原始摘要信息
点击此处可从《眼科新进展》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号