Abstract: | A competitive binding radioimmunoassay (CBA) for antibody to hepatitis A virus (HAV) was evaluated and compared with a standard solid-phase radioimmunoassay for anti-HAV, CBA was found to be sensitive and specific for the detection of anti-HAV, as demonstrated by the 98% concordance of CBA and solid-phase radioimmunoassay test results. The standard CBA test was modified for the differential detection of acute (immunoglobulin M) and convalescent (immunoglobulin G) anti-HAV by incorporation of a step in which immunoglobulin G anti-HAV was preferentially absorbed with S. aureus cells (protein A). The modified CBA test was shown to be capable of differentiating between acute- and convalescent-phase sera. The modified CBAM test was able to detect immunoglobulin M anti-HAV up to approximately 4 weeks after the onset of illness. |