首页 | 本学科首页   官方微博 | 高级检索  
     

时透视触发三维动态增强磁共振血管成像技术及其在颈部动脉的应用
引用本文:冯德朝,徐亮,丛培新,郑金勇,孟祥水,崔宜,李传福. 时透视触发三维动态增强磁共振血管成像技术及其在颈部动脉的应用[J]. 山东大学学报(医学版), 2006, 44(9): 918-921
作者姓名:冯德朝  徐亮  丛培新  郑金勇  孟祥水  崔宜  李传福
作者单位:山东大学齐鲁医院影像中心磁共振室, 山东 济南 250012
摘    要:目的:探讨磁共振实时透视触发三维增强磁共振血管成像技术(3DDCEMRA)在颈部动脉临床应用的可行性。方法:颈部动脉疾病患者和颈部动脉正常者各30例,均行三维快速时间飞跃磁共振血管成像(3DTOFMRA)和3DDCEMRA。3DTOFMRA采用三维快速时间飞跃梯度回波(3DFGRE)序列,薄层、多层块轴位扫描;3DDCEMRA应用三维快速时间飞跃干扰梯度回波(3DFSPGR)序列,快速注射(注射速度2.0~3.0?ml/s)对比剂钆-喷替酸葡甲胺(Gd DTPA)20~25?ml(0.15~0.2?mmol/kg),磁共振实时透视触发即时扫描。两种方法所得全部原始图像在后处理工作站进行MIP重建,按解剖及影像诊断要求对颈部动脉的显示效果、颈部正常动脉连续性及边缘锐利度等进行比较评价。结果:60例颈部3DDCEMRA图像中,57例颈部动脉显示较佳,占95%;显示不佳3例,占5%;其中疾患组诊断为动脉硬化斑块3例、血管狭窄15例、血管闭塞6例、血管畸形4例、细小动脉瘤2例。3DDCEMRA对颈部动脉的显示效果、颈部正常动脉连续性及边缘锐利度等均优于3DTOFMRA(Р<0.001)。结论:3DDCEMRA对颈部动脉的硬化斑块、狭窄、闭塞、畸形、细小动脉瘤等病变的诊断均优于传统3DTOFMRA,具有较高的临床应用价值。

关 键 词:磁共振透视  磁共振血管成像  颈动脉
文章编号:1671-7554(2006)09-0918-04
收稿时间:2005-06-12
修稿时间:2005-06-12

Three-dimensional dynamic contrast-enhanced MR angiography with real-time fluoroscopic triggering: techniques and clinical applications in carotid arteries
FENG De-chao,XU Liang,CONG Pei-xin,ZHENG Jin-yong,MENG Xiang-shui,CUI Yi,LI Chuan-fu. Three-dimensional dynamic contrast-enhanced MR angiography with real-time fluoroscopic triggering: techniques and clinical applications in carotid arteries[J]. Journal of Shandong University:Health Sciences, 2006, 44(9): 918-921
Authors:FENG De-chao  XU Liang  CONG Pei-xin  ZHENG Jin-yong  MENG Xiang-shui  CUI Yi  LI Chuan-fu
Affiliation:Imaging Center, Qilu Hospital of Shandong University, Jinan 250012, Shandong, China
Abstract:To investigate the feasibility of three dimensional dynamic contrast enhanced MR angiography (3DDCEMRA) with real time fluoroscopic triggering in carotid arteries. Methods: Three dimensional time of flight MR angiography (3DTOFMRA) and 3DDCEMRA were performed in 60 cases. 3DTOFMRA imaging sequence was three dimensional fast gradient echo with thin slice and multi slab, and 3DDCEMRA imaging sequence was three dimensional time of flight spoiled gradient echo. The 20 25?ml Gd DTPA was injected with the rate of 2.0 3.0?ml/sec and the dose 0.15 0.2?ml/kg. With the MR fluoroscopic triggering technique, all the primary graphs were analyzed by maximum intensity projection reconstruction in the post processing station. The image qualities, included sensitivity, continuity and sharp edged degree of these two different techniques were evaluated according to the diagnosed demand and dissecting. Results: Major branch was displayed in 57 cases, which presented 95% of total of cases classified as good image quality. 3DDCEMRA had significantly higher sensitivity, continuity, and sharp edged degree than 3DTOFMRA in evaluation of carotiarteries. Conclusion: 3DDCEMRA is an effectively and minimally invasive method for evaluating lesions in carotid arteries.
Keywords:Magnetic fluoroscopy  Magnetic resonance angiography  Carotid arteries
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《山东大学学报(医学版)》浏览原始摘要信息
点击此处可从《山东大学学报(医学版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏