Comparison of commercial slide agglutination kits with a tube coagulase test for the rapid identification of Staphylococcus aureus from blood culture. |
| |
Authors: | R P Cooke and C T Jenkins |
| |
Affiliation: | Department of Medical Microbiology, District General Hospital, East Sussex. |
| |
Abstract: | Eighty clinical specimens of BACTEC 9240 blood culture vials, culture positive for staphylococci (38 Staphylococcus aureus and 42 coagulase negative staphylococci), were tested directly for the presence of clumping factor/protein A and free coagulase. Seven commercial slide agglutination kits were compared with a direct-tube coagulase (DTC) method. All tests were performed on blood culture pellets. Sensitivity, specificity, and negative and positive predictive values for the seven commercial kits were extremely variable, whereas a two-hour DTC test was highly predictive of S aureus. There was no significant difference between a two-, six- or 24-hour DTC test. Three (8%) S aureus isolates remained DTC negative even after 24 hours' incubation. Staphylococcal slide agglutination kits should not be used directly on blood culture broths. In contrast, a two-hour DTC test is a useful, rapid screening test for S aureus bacteraemia, provided isolates from DTC negative blood culture broths are re-tested using standard laboratory techniques. |
| |
Keywords: | |
|
|