首页 | 本学科首页   官方微博 | 高级检索  
     

环境光和邻牙对前牙接触式测色仪测色结果的影响
引用本文:王思钱,Sean S. Lee,Wu Zhang,Yiming Li,麻健丰. 环境光和邻牙对前牙接触式测色仪测色结果的影响[J]. 华西口腔医学杂志, 2007, 25(5): 477-480
作者姓名:王思钱  Sean S. Lee  Wu Zhang  Yiming Li  麻健丰
作者单位:温州医学院附属口腔医院,修复科,浙江,温州,325027;罗玛琳达大学,生物材料研究中心,美国
摘    要:目的探讨外源性环境光和邻牙对接触式测色仪测量牙齿颜色结果的影响。方法将10颗离体上颌中切牙固定,MI- 150光源从牙齿的唇面(切缘朝下)3点钟和12点钟上方45°入射,入射强度分别为0、50、75、100、125、150 W,在有邻牙和无邻牙时分别测量10颗离体中切牙中1/3正中点的CIE L﹡a﹡b﹡值,测量结果采用SPSS11.5软件进行统计分析。结果不同强度和方向的入射光及邻牙存在与否对颜色测量结果均没有明显影响(P>0.05)。结论环境光源和邻牙对接触式测色仪的测色结果没有影响,临床上在牙椅外源辅助灯光下可以采用接触式测色仪直接测色。

关 键 词:色彩色差计  牙齿  颜色测量
文章编号:1000-1182(2007)05-0477-04
收稿时间:2007-10-25
修稿时间:2006-12-11

Influence of ambient light and adjacent tooth in anterior tooth color measurement
WANG Si-qian,Sean S. Lee,Wu Zhang,Yiming Li,MA Jian-feng. Influence of ambient light and adjacent tooth in anterior tooth color measurement[J]. West China journal of stomatology, 2007, 25(5): 477-480
Authors:WANG Si-qian  Sean S. Lee  Wu Zhang  Yiming Li  MA Jian-feng
Affiliation:1. Dept. of Prosthodontics, Hospital of Stomatology, Wenzhou Medical College, Wenzhou 325027, China; 2. Center for Dental Research, Loma Linda University, USA
Abstract:OBJECTIVE: To investigate the influence of different intensity and directions of ambient light and adjacent tooth in anterior tooth color measurement by using colorimeter. METHODS: Fiber lite MI-150 was used as ambient illuminant and it irradiated from three or twelve o'clock direction through 45 degrees angle above. The light magnitude 0, 50, 75, 100, 125, 150 W were applied in this experiment. The values of CIE L* a* b* were measured by Minolta Chroma meter CR-321 colorimeter on the center labial surface of ten extracted human maxillary central incisors with or without adjacent teeth, then those data were analyzed statistically by using SPSS 11.5. RESULTS: Neither different intensities nor different directions of ambient light could influence the results of color measurement by using Minolta Chroma meter CR-321 colorimeter, so did the adjacent teeth whether those were exist or not. CONCLUSION: There is no influence of ambient light and adjacent teeth in the color measurement of anterior teeth under this experiment condition, and Minolta Chroma meter CR-321 colorimeter can be used to measure the color directly aside the chair with light.
Keywords:colorimeter  tooth  color measurement
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《华西口腔医学杂志》浏览原始摘要信息
点击此处可从《华西口腔医学杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号