首页 | 本学科首页   官方微博 | 高级检索  
     

内置自动弹力牵引成骨装置的设计应用
引用本文:周宏志,胡敏,胡开进,姚军,刘洪臣. 内置自动弹力牵引成骨装置的设计应用[J]. 华西口腔医学杂志, 2005, 23(5): 370-372
作者姓名:周宏志  胡敏  胡开进  姚军  刘洪臣
作者单位:1.第四军医大学口腔医院 口腔颌面外科,陕西 西安710032;2.解放军总医院 口腔科,北京100853
基金项目:国家自然科学基金资助项目(30171017),北京市自然科学基金资助项目(7042058)
摘    要:目的 完善记忆合金弹力牵引器的辅助固定导引装置设计,初步探索其应用的可行性。方法 利用正弦波形记忆合金弹力牵引器、医用重建钛板、小型钛板配合构成内置式自动弹力牵引装置,构建牵引成骨重建下颌骨颏部约6 cm节段缺失的杂种犬动物模型,观察新型装置的应用效果。结果 实验设计装置可基本按照预想方式自动完成骨牵引,手术后2个月内即可形成节段再生骨,可延长截短的双侧下颌骨。结论 内置自动弹力牵引装置显示了实际应用的可行性和优越性,但在牵引力控制等方面还需要深入研究。

关 键 词:牵引成骨  下颌骨  骨重建  内置固定器  
文章编号:1000-1182(2005)05-0370-03
收稿时间:2004-11-02
修稿时间:2005-08-03

Design and Application of Internal Devices for Automatic Elasticity Distraction Osteogenesis
ZHOU Hong-zhi,HU Min,HU Kai-jin,YAO Jun,LIU Hong-chen. Design and Application of Internal Devices for Automatic Elasticity Distraction Osteogenesis[J]. West China journal of stomatology, 2005, 23(5): 370-372
Authors:ZHOU Hong-zhi  HU Min  HU Kai-jin  YAO Jun  LIU Hong-chen
Affiliation:1.Dept.ofOral andMaxillofacial Surgery,College ofStomatology,Fourth Milit- aryMedical University,Xi′an710032,China; 2.Dept.ofStomatology,PLAGeneralHospital,Beijing100853,China
Abstract:Objective To improve the design of the devices used for automatic elasticity distraction osteogenesis,and to preliminarily testify their feasibility for clinical application.Methods The internal automatic distraction devices were constructed by three parts,including sinusoid shape memory alloy distractor,reconstructive plate and mini_plate.The animal model of trifocal bone transport reconstruction of canine mandibular mentis was duplicated,in which a 6 cm mandibular mentis segment was removed and the transport disc was created by osteotomy in both ends of the mandibular defect.The plates were used for internal fixation and shape reconstruction of the mandible.They also served as transport distraction guidance for the elasticity distractor.Results The new devices could complete bone transport as expected.Regenerated bone segments were formed in two months and both sides of the mandibular body were lengthened.Because of the narrow angle and obstruction from the thick soft tissues in the mentis area,the ultimate symphysis mentalis was not reconstructed.Conclusion The design of the internal elasticity distraction devices showed potential feasibility for clinical practice.But further studies are still needed for better control of the strength and balance of distraction forces.
Keywords:distraction osteogenesis  mandible  bone regeneration  internal fixators
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《华西口腔医学杂志》浏览原始摘要信息
点击此处可从《华西口腔医学杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号