Investigation of reduced susceptibility to glycopeptides among methicillin-resistant Staphylococcus aureus isolates from patients in Ireland and evaluation of agar screening methods for detection of heterogeneously glycopeptide-intermediate S. aureus |
| |
Authors: | Fitzgibbon Margaret M Rossney Angela S O'Connell Brian |
| |
Affiliation: | National MRSA Reference Laboratory, St. James's Hospital, James's St., Dublin 8, Ireland. |
| |
Abstract: | Methicillin-resistant Staphylococcus aureus (MRSA) isolates (n = 3,189) from 2,990 patients were investigated by agar screening and by the Etest macromethod for reduced susceptibility to glycopeptide. No vancomycin-resistant S. aureus or glycopeptide-intermediate S. aureus (GISA) isolates were detected, but 178 isolates were confirmed as hetero-GISA (hGISA) by vancomycin population analysis profile (vPAP)-area under the curve (AUC) ratio determination and/or teicoplanin PAP (tPAP) methods. Of 139 isolates detected using the recommended Etest macromethod cutoff values of > or =8 mg/liter for both vancomycin and teicoplanin or > or =12 mg/liter for teicoplanin alone, 73 were confirmed as hGISA by vPAP-AUC, 95 were confirmed as hGISA by tPAP, and 108 were confirmed as hGISA by both methods. An Etest macromethod cutoff value of 8 mg/liter for teicoplanin alone detected a further 70 hGISA (17 were confirmed by vPAP-AUC and 70 were confirmed by tPAP). Agar screening utilizing brain heart infusion (BHI) agar containing 6 mg of vancomycin/liter (BHIV6) and Mueller-Hinton (MH) agar containing 8 mg of teicoplanin/liter (MHT8) failed to detect hGISA. MH agar containing 5 mg of teicoplanin/liter (MHT5) and BHI containing 5 mg of teicoplanin/liter (BHIT5) were evaluated using 10-microl volumes of three inoculum concentrations (with densities equivalent to 0.5 and 2.0 McFarland turbidity standards and stationary-phase BHI broth subcultures [MHT5(0.5), MHT5(2.0), MHT5(S), BHIT5(0.5), BHIT5(2.0), and BHIT5(S)]). The sensitivity of all methods except MHT5(0.5) and MHT5(2.0) was 100%. The specificity ranged from 4 to 82%. BHIT5(0.5) yielded the best performance, with a specificity of 84% for detecting isolates with teicoplanin Etest macromethod values of > or =8 mg/liter. Screening on BHIT5(0.5) is useful where screen-positive isolates are investigated with the Etest macromethod and confirmed by vPAP-AUC and tPAP. The prevalence of hGISA among patients with blood culture isolates recovered in Irish hospitals between 1999 and 2003 was 2.6%, whereas the prevalence among patients with isolates from all specimen sites collected during a 2-week survey in 1999 was 12%. The prevalence in one hospital decreased from 5.3% in 2003 to 1.5% in 2004. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|