首页 | 本学科首页   官方微博 | 高级检索  
检索        

对比剂不同流率对门静脉CT血管成像质量的影响
引用本文:雷建明,董鹏,全冠民,袁涛,柳青,屈长强,卜静英,宋鹏,刘武杰.对比剂不同流率对门静脉CT血管成像质量的影响[J].实用放射学杂志,2010,26(2).
作者姓名:雷建明  董鹏  全冠民  袁涛  柳青  屈长强  卜静英  宋鹏  刘武杰
作者单位:1. 河北医科大学第二医院影像科,河北,石家庄,050000
2. 河北钢铁集团邯钢公司医院影像科
基金项目:河北省科学技术研究与发展计划项目,河北医科大学第二医院2006年科研资助课题 
摘    要:目的 探讨对比剂不同注射流率对多层螺旋CT肝门静脉成像质量的影响.方法 30例患者随机分为3组,每组10例,年龄与体重无明显差异,行腹部CT增强扫描.按1.5 ml/kg剂量前臂静脉注射浓度为300 mg Ⅰ/ml的非离子型对比剂,注射流率分别为2.0 ml/s、3.0 ml/s和4.0 ml/s.腹主动脉兴趣区智能跟踪技术触发动脉期扫描,动脉期后延迟7 s与20 s行门静脉期扫描.在工作站测量3组CT源图像上门静脉(PV)与肝实质的CT值,并重组PV斜轴位与冠状位最大密度投影(MIP)图像,观察PV显示的分支级别.采用SPSS 11.5软件行统计学分析.结果 2.0 ml/s组、3.0 ml/s组、4.0 ml/s组门静脉CT值分别为(150.80±21.16)HU、(170.90±17.26)HU与(181.90±22.88)HU,2.0 ml/s组与4.0 ml/s组间有明显差别(P=0.017).2.0 ml/s组、3.0 ml/s组、4.0 ml/s组PV与肝实质CT值差别分别是(50.20±17.40)HU、(67.10±23.08)HU与(76.20±22.75)HU,2.0 ml/s组与4.0 ml/s组间有明显差别(P=0.039).2.0 ml/s组、3.0 ml/s组、4.0ml/s组对PV分支显示级别分别为4.20±1.14、4.90±0.99及5.50±0.53,2.0 ml/s组与4.0 ml/s组间有明显差别(P=0.013).结论 注射流率对PV CT血管成像的质量有影响,流率为4.0 ml/s时SCTP质量最佳.

关 键 词:对比剂  体层摄影术  X线计算机  门静脉造影术

Influence of Velocity of Flow of Contrast Media on Spiral CT Portography
LEI Jian-ruing,DONG Peng,QUAN Guan-min,YUAN Tao,LIU Qing,QU Chang-qiang,BU Jing-ying,SONG Peng,LIU Wu-jie.Influence of Velocity of Flow of Contrast Media on Spiral CT Portography[J].Journal of Practical Radiology,2010,26(2).
Authors:LEI Jian-ruing  DONG Peng  QUAN Guan-min  YUAN Tao  LIU Qing  QU Chang-qiang  BU Jing-ying  SONG Peng  LIU Wu-jie
Abstract:Objective To investigate the effect of different injection rate of contrast medium on the quality of multislice spiral CT portography(SCTP). Methods Thirty patients with no prominent difference in the age and weight randomly divided into 3 groups (10 cases each group) underwent contrast-enhanced CT scan of abdomen. Non-ionic contrast medium (300 mgⅠ/ml, 1.5 ml/kg) was injected through antebrachium veins with power injector at the rates of 2.0 ml/s,3.0 ml/s and 4.0ml/s. Arterial phase acquisi-tion was made using the software of automated bolus triggering with a ROI placed on abdominal aorta when 100 HU was reached, and 7 seconds and 20 seconds later, portal phases were done respectively. The attenuations of portal vein(PV) and hepatic parenchy-ma of 3 groups were measured on source images. Then the oblique axial and coronal maximum intensity projection(MIP) maps were reconstructed at workstation and PVs were observed. Statistics analysis was made with software of SPSS 11.5. Results The attenu-ations of PV in 2.0ml/s, 3.0 ml/s and 4.0 ml/s groups were (150.80±21.16)HU, (170.90±17.26)HU and 181.90±22.88) HU respectively. There was obvious difference between 2.0ml/s and 4.0ml/s groups for atteuation of PV(P=0.017). The differences of CT attenuation of PV-hepatic parenchyma in three groups were (50.20±17.40) HU, (67.10±23.08) HU and (76.20±22.75) HU respectively. Prominent difference was also found between 2.0 ml/s and 4.0 ml/s groups(P=0.039). The grades of segment of PV displayed on SCTP maps were 4.20±1.14,4.90±0.99 and 5.50±0.53 in 2.0 ml/s,3.0 ml/s and 4.0 ml/s groups respectively, which were of obvious differences between them (P=0.013). Conclusion Injection rate of contrast medium dose influence the quality of SCTP of PV,SCTP quality is best with velocity of flow at 4.0 ml/s.
Keywords:contrast medium  tomography  X-raycomputed  portography
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号