摘    要:目的:建立对乙酰氨基酚片的反相高效液相色谱法。方法色谱柱为Waters-C18(4.6mm ×250mm,5μm),流动相:甲醇-1%冰醋酸溶液(30∶70),流速为1.0mL· min -1,柱温为35℃,检测波长为246nm。结果对乙酰氨基酚进样量在0.0402~1.0055μg范围内与峰面积呈良好线性关系,r=0.9997,平均回收率为99.43%,RSD=0.31%(n=9)。结论该方法准确度、灵敏度及重复性均较好,可作为对乙酰氨基酚片的含量测定。

关 键 词:对乙酰氨基酚片  反相高效液相色谱法  含量测定

Content Determination of Acetaminophen Tablets by RP-HPLC
Abstract:OBJECTIVE To establish a RP-HPLC method for the determination of acetaminophen tab-lets.METHODS Column Waters-C18(4.6mm ×250mm,5μm),mobile phase was methanol∶1% acetic acid solu-tion (30∶70),the flow rate was 1.0mL· min-1,the column temperature was 35℃,the detection wavelength was 246nm.RESULTS The sample presented good linear relationship in the range of 0.0402 ~1.0055μg, r =0.9997.The average recovery rate was 99.43%, RSD=0.31%( n=9 ) .CONCLUSION The method was accu-rate,sensitive and reproducible,and can be used as an assay for the determination of the content of acetaminophen tablets.