环孢素A和他克莫司血药浓度监测的质控评价与分析
引用本文:谢诚,钱美英,缪丽燕.环孢素A和他克莫司血药浓度监测的质控评价与分析[J].中国药房,2008,19(32):2508-2510.
作者姓名:谢诚  钱美英  缪丽燕
作者单位:苏州大学附属第一医院临床药理室
摘    要:目的:评价荧光偏振免疫分析法测定环孢素A(CsA)以及微粒子酶免分析(MEIA)法测定他克莫司(FK506)血药浓度过程中质控的稳定性。方法:对2007年6~8月我院作CsA和FK506血药浓度监测患者血样的质控结果进行连续性评价与分析,考察其稳定性和准确性。结果:CsA和FK506低、中、高3种浓度质控的平均相对回收率分别为93.14%~97.65%、97.70%~103.09%,RSD分别为4.41%~5.37%、10.44%~14.23%,符合《中国药典》生物样品监测规定。结论:荧光偏振免疫分析法测定CsA和MEIA法测定FK506血药浓度的方法较为准确,值得在临床应用并指导个体化给药。

关 键 词:环孢素A  他克莫司  血药浓度监测  质控

Assessment and Analysis of Quality Control for Therapeutic Drug Monitoring of Cyelosporine A and Tacrolimus
XIE Cheng,QIAN Mei-ying,MIAO Li-yan.Assessment and Analysis of Quality Control for Therapeutic Drug Monitoring of Cyelosporine A and Tacrolimus[J].China Pharmacy,2008,19(32):2508-2510.
Authors:XIE Cheng  QIAN Mei-ying  MIAO Li-yan
Institution:(Dept. of Clinical Pharmacology, The First Affiliated Hospital of Suzhou University, Suzhou 215006, China)
Abstract:OBJECTIVE: To assess the stability of the quality control of FPIA for monitoring of CsA and MEIA for monitoring of FK506. METHODS: The quality control on the blood samples of patients receiving therapeutic drug monitoring of CsA and FK506 from June to August in 2007 were subjected to a continual assessment and analysis to investigate the stability and accuracy of the quality control. RESULTS: The mean recoveries of the low, middle and high concentrations of CsA and FK506 were 93.14%-97.65% and 97.70%- 103.09% respectively, with RSD at 4.41%-5.37% and 10.44%-14.23% respectively, which accorded with the requirement for biological sample determination stated in the Chinese Pharmacopoeia. CONCLUSION : The methods of FPIA for monitoring of CsA and MEIA for monitoring of FK506 were accurate, and worth to be applied in clinical to guide individualized medication.
Keywords:Cyclosporine A  Tacrolimus  Therapeutic drug monitoring  Quality control