胎心监护联合脐血血气分析及Apgar评分预测羊水粪染新生儿窒息的临床价值
引用本文:杨健红,谭艳丽,唐红,姚毓筠,潘柳萍,文哲.胎心监护联合脐血血气分析及Apgar评分预测羊水粪染新生儿窒息的临床价值[J].广西医学,2016(1):35-38.
作者姓名:杨健红  谭艳丽  唐红  姚毓筠  潘柳萍  文哲
作者单位:1. 广西梧州市红十字会医院妇产科,梧州市,543002;2. 广西梧州市红十字会医院儿科,梧州市,543002
基金项目:广西梧州市科技计划项目
摘    要:目的:探讨胎心监护联合脐动脉血气分析及Apgar评分对羊水粪染窒息新生儿的预测价值。方法对585例羊水粪染新生儿进行分娩前胎心监护,出生后立即采集脐动脉血进行pH值测定,进行Apgar评分,分析3项指标与脏器损伤的关系,以及三者联合诊断羊水粪染新生儿窒息的灵敏度、特异度及符合率。结果585例羊水粪染新生儿中共确诊窒息49例,占8.4%。随着pH值、Apgar评分的降低出现脏器损伤的新生儿比例升高(P<0.05),胎心监护异常组的脏器损伤发生率较正常组明显升高( P<0.05)。低Apgar评分(≤7分)联合异常胎心监护、脐动脉血pH值<7诊断羊水粪染新生儿窒息的敏感性为44.9%,特异性为100.0%,符合率为57.1%;低Apgar评分联合脐动脉血pH值<7.2、异常胎心监护诊断窒息的敏感性为83.7%,特异性为78.6%,符合率为82.5%。结论胎心监护联合脐动脉血气分析、Apgar评分可有效地预测评价羊水粪染新生儿窒息,为窒息新生儿及时采取正确的治疗措施提供了可靠的依据。

关 键 词:新生儿窒息  羊水粪染  胎心监护  脐动脉血气分析  Apgar评分  诊断

Predictive value of fetal heart rate monitoring combined with umbilical arterial blood gas analysis and Apgar score for asphyxia neonatorum with meconium-stained amniotic fluid
Abstract:Objective To explore the predictive value of fetal heart rate monitoring combined with umbilical arterial blood gas analysis and Apgar score for asphyxia neonatorum with meconium-stained amniotic fluid .Methods A total of 585 neonates with meconium-stained amniotic fluid received the antepartum fetal heart rate monitoring .And the umbilical arterial blood was collected to detect the pH values ,and Apgar score was performed at birth in all neonates .The relationship of the three indices with organ injuries was analyzed .And the sensitivity , specificity and coincidence rate of the three indices were assessed for the combined diagnosis of asphyxia neonatorum with meconium -stained amniotic fluid.Results Of 585 neonates with meconium-stained amniotic fluid,49 were definitely diagnosed as asphyxia ,accounting for 8.4%.The proportion of neonates with organ injuries increased with the decrease of pH values or Apgar score (P<0.05).The incidence of organ injuries in the abnormal fetal heart rate monitoring group was significantly higher than that in the normal group (P<0.05).For diagnosis of asphyxia neonatorum with meconium-stained amniotic fluid,the sensitivity,specificity and coincidence rate of low Apgar score (≤7) combined with abnormal fetal heart rate monitoring and umbilical arterial pH<7 were 44.9%,100.0%and 57.1%,respectively;The sensitivity,specificity and coincidence rate of low Apgar score combined with abnormal fetal heart rate monitoring and umbilical arterial pH <7.2 were 83.7%,78.6%and 82.5%,respectively.Conclusion Fetal heart rate monitoring combined with umbilical arterial blood gas analysis and Apgar score can effectively predict asphyxia neonatorum with meconium-stained amniotic fluid .And it can provide a reliable basis for the early diagnosis and proper treatment of asphyxia neonatorum .
Keywords:Asphyxia neonatorum  Meconium-stained amniotic fluid  Fetal heart rate monitoring  Umbilical arterial blood gas analysis  Apgar score  Diagnosis