30例双胎输血综合征声像图特征的回顾性分析
引用本文:李哲,张晓航,李锐,华兴,钟华,薛雅方,郭燕丽,陈朝晖,唐春霖.30例双胎输血综合征声像图特征的回顾性分析[J].第三军医大学学报,2012,34(2):122-125.
作者姓名:李哲  张晓航  李锐  华兴  钟华  薛雅方  郭燕丽  陈朝晖  唐春霖
作者单位:李哲 (400038重庆,第三军医大学西南医院超声科) ; 张晓航 (841700乌鲁木齐,解放军第546医院超声科) ; 李锐 (第三军医大学西南医院超声科,重庆,400038) ; 华兴 (第三军医大学西南医院超声科,重庆,400038) ; 钟华 (第三军医大学西南医院超声科,重庆,400038) ; 薛雅方 (第三军医大学西南医院超声科,重庆,400038) ; 郭燕丽 (第三军医大学西南医院超声科,重庆,400038) ; 陈朝晖 (第三军医大学西南医院超声科,重庆,400038) ; 唐春霖 (第三军医大学西南医院超声科,重庆,400038) ;
基金项目:"十一五"国家科技支撑计划,重庆市人口与计划生育科研课题
摘    要:目的探讨产前超声检查对双胎输血综合征的预测、诊断及价值。方法对2006年8月至2011年3月在本科确诊,并有最终随访结果的30例双胎输血综合征孕妇的60个胎儿的超声表现进行回顾性分析。结果 30例孕妇中共60个胎儿,17例孕妇的胎儿S/D增高,而且受血儿较供血儿增高明显;14例孕妇的受血儿心脏增大,1例孕妇供血儿心脏增大;8例孕妇的供血儿为贴壁儿;20例孕妇接受胎儿镜治疗,15例较治疗前有明显好转;脐带帆状入口和边缘入口的胎儿经治疗后存活率低。结论产前超声对双胎输血的及时诊断、治疗和提高胎儿生存率具有明显的临床价值。

关 键 词:超声表现  双胎输血综合征  胎儿镜

Prenatal ultrasonographic features of twin-to-twin transfusion syndrome: a retrospective analysis of 30 cases
Li Zhe,Zhang Xiaohang,Li Rui,Hua Xing,Zhong Hua,Xue Yafang,Guo Yanli,Chen Zhaohui,Tang Chunlin.Prenatal ultrasonographic features of twin-to-twin transfusion syndrome: a retrospective analysis of 30 cases[J].Acta Academiae Medicinae Militaris Tertiae,2012,34(2):122-125.
Authors:Li Zhe  Zhang Xiaohang  Li Rui  Hua Xing  Zhong Hua  Xue Yafang  Guo Yanli  Chen Zhaohui  Tang Chunlin
Institution:1(1Department of Ultrasonography,Southwest Hospital,Third Military Medical University,Chongqing,400038;2Department of Ultrasonography,No.546 Hospital of PLA,Xinjiang Uygur Autonomous Region,841700,China)
Abstract:Objective To identify the clinical value of prenatal ultrasonography to predict and diagnose twin-to-twin transfusion syndrome.Methods The ultrasonographic data of 30 pregnant women of twin-to-twin transfusion syndrome including 60 fetuses who were diagnosed and followed up in our hospital from Aug.2006 to Mar.2011 were retrospectively analyzed.Results Among the 30 women with 60 fetuses,the S/D value of 17 pregnant women’s fetuses was increased,particularly in the recipient fetus.The 14 cases of recipient fetuses had enlarged heart,but the heart of one donor fetus showed same symptom.There were 8 donors attached to chorionic membrane.Among the 20 cases underwent fetoscopic treatment,15 cases had significantly changes.The fetus having fan-shaped and edge umbilical cord inlet had lower survival rate.Conclusion Prenatal ultrasonic examination is helpful to the immediate diagnosis and treatment of twin-to-twin transfusion syndrome,and has a positive effect to improve fetuses’ survival.
Keywords:ultrasonographic manifestation  twin-to-twin transfusion syndrome  fetoscopy