高能聚焦超声治疗宫颈糜烂的疗效
引用本文:隋龙,孙红,李成志,胡志琴,卫明花.高能聚焦超声治疗宫颈糜烂的疗效[J].复旦学报(医学版),2005,32(1):95-97.
作者姓名:隋龙  孙红  李成志  胡志琴  卫明花
作者单位:1. 复旦大学附属妇产科医院光电室,上海,200011
2. 重庆医科大学医学超声工程研究所,重庆,400016
摘    要:目的探讨高能聚焦超声治疗宫颈糜烂的有效性及安全性。方法采用海极星超声波妇科治疗仪对40例宫颈糜烂患者进行聚焦超声治疗的临床观察,比较治疗前后临床症状的变化和宫颈糜烂面积的改变,综合评价超声治疗的临床疗效。结果聚焦超声治疗后,白带增多,性交后出血等症状基本缓缓,轻、中和重度宫颈糜烂面积分别缩小97.89%、90.69%和81.91%;疗效分别达到100%、93.33%和72.22%。聚焦超声治疗后,宫颈局部组织有短暂的渗出性炎症反应,阴道排液的时间约5~21d,1月后可基本恢复正常;无组织结痂脱落出血的过程,无宫颈瘢痕形成。结论治疗剂量的高能聚焦超声波能安全有效地治疗慢性子宫颈炎。

关 键 词:宫颈糜烂  治疗后  高能聚焦超声  出血  疗效  超声治疗  论治  中和  超声波  脱落
修稿时间:2004年3月10日

Preliminary Observation of the Effect of High Intensity Focused Ultrasound on Chronic Cervicitis
SUI Long,SUN Hong,LI Cheng-zhi,HU Zhi-qin,WEI Ming-hua.Preliminary Observation of the Effect of High Intensity Focused Ultrasound on Chronic Cervicitis[J].Fudan University Journal of Medical Sciences,2005,32(1):95-97.
Authors:SUI Long  SUN Hong  LI Cheng-zhi  HU Zhi-qin  WEI Ming-hua
Institution:SUI Long,SUN Hong,LI Cheng-zhi,HU Zhi-qin,WEI Ming-hua Department of Photoelectricity,Obstetrics & Gynecology Hospital,Fudan University,Shanghai 200011,Institute of Ultrasound Engineering in Medicine,Chongqing University of Medical Sciences,Chongqing 400016,China
Abstract:Purpose To investigate the efficacy and reliability of high intensity focused ultrasound treatment on chronic cervicitis. Methods The seapostar gynecological ultrasound therapeutic equipment was applied to treat 40 cases with chronic cervicitis. The changes of clinical manifestations and cervical erosion area before and after treatment were recorded and compared. And the efficacy and reliability of focused ultrasound treatment of cervicitis was generally evaluated. Results The volume of leucorrhea discharge decreased and postcoital bleeding remissioned after the treatment of high intensity focused ultrasound on chronic cervicitis The cervical erosion area with mild, moderate and severe degree cervicitis was decreased by 97.89 %,90.69%and 81.9%,respectively.The therapeutic efficacy of focused ultrasound on mild, moderate and severe cervicitis reached to 100% ,93.33% and 72.22% , respectively.The reactive exudation was transitory after treatment and large leucorrhea discharge lasted for five to twenty-one days. The patient could recovered in about one month. No severe bleeding resulted from scar-shedding occurred and there was no scar formation in the cervical canal.Conclusions High intensity focused ultrasound could treat chronic cervicitis effectively and safely. It will be one nice alternative to treat cervicitis.
Keywords:chronic cervicitis  high intensity focused ultrasound  efficacy