首页 | 本学科首页   官方微博 | 高级检索  
检索        

彩超引导粗针穿刺活检对比细针吸取诊断甲状腺结节的应用价值
引用本文:姜 越,龚建安,邓 博,等.彩超引导粗针穿刺活检对比细针吸取诊断甲状腺结节的应用价值[J].海南医学院学报,2014(5):667-669.
作者姓名:姜 越  龚建安  邓 博  
作者单位:桂洲医院外三科,广东佛山528303
基金项目:2012年佛山市医学攻关课题:粗针穿刺活检在早期乳腺癌诊断中的应用研究(20121021030007)
摘    要:目的:评价彩色多普勒引导下粗针穿刺活检(CNB)和细针吸取(FNA)甲状腺结节良、恶性的准确性和安全性。方法:回顾性分析141例甲状腺结节均行CNB和FNA,并对比CNB和FNA在诊断甲状腺结节良、恶性的诊断符合率和术后并发症发生率之间的比较。结果:141例甲状腺结节中CNB和FNA诊断符合率分别为99.29%和93.61%,差异有统计学意义(P〈0.05);本组研究中CNB良性结节符合率为100%,FNA诊断良性结节的符合率95.38%;恶性结节CNB诊断符合率90.9%(10/11),FNA诊断符合率72.72%(8/11)。CNB和FNA特异性分别99.29%和93.61%;CNB和FNA敏感性分别为100%、95.38%;CNB和FNA出现皮下血肿分别是1.41%、0.07%,差异无统计学意义(P〉0.05)。结论:甲状腺结节在彩超引导下CNB比FNA更准确,同样是一种安全、简便鉴别甲状腺结节良、恶性的方法并可以更准确地指导临床治疗,能减少良性结节手术率。

关 键 词:粗针穿刺活检  细针吸取  甲状腺结节  彩超

Study of Color-Doppler guided core needle biopsy versus fine-needle aspiration for the diagnosis of thyroid nodules
JIANG Yue,GONG Jian-an,DENG Bo,LIANG Sheng-zhi,WU Yue-rui,XU Wei,GAO Song.Study of Color-Doppler guided core needle biopsy versus fine-needle aspiration for the diagnosis of thyroid nodules[J].Journal of Hainan Medical College,2014(5):667-669.
Authors:JIANG Yue  GONG Jian-an  DENG Bo  LIANG Sheng-zhi  WU Yue-rui  XU Wei  GAO Song
Institution:(No. 3 Surgery Department, Guizhou Hospital, Foshan 528303, Guangdong China)
Abstract:Objective: To evaluate the accuracy and security of color-doppler guides core-needle biopsy (CNB) and fine-needle aspiration(FNA) for the diagnosis of thyroid nodules. Methods: We evaluated the results of CNB and FNA in 141 case thyroid nodules with comparing final diagnoses. We assessed the accuracy and security of CNB and FNA for the diagnosis of thyroid nodules. Results: For the 141 cases of thyroid nodule, CNB and FNA showed diagnostic coincidence rate of 99.29% and 93.61%, and the difference was statistically significant (P〈0.05). For benign nodules diagnosed by CNB, the coincidence rate was 100%, while for FNA diagnosis the coincidence rate of the benign nodules was 95.38%. For malignant nodules diagnosed by CNB diagnosis, the coincidence rate was 90.9%, for FNA diagnosis the coincidence rate was 72.72%. The specificity of CNB and FNA was 100% ,95.38%. Incidence of subcutaneous hematoma for CNB and FNA was 1.41% and 0.07% respectively showing no significant difference. Conclusion: Color-Doppler guided CNB is more safe and more accurate in diagnosis of thyroid nodule, especial- ly for differentiation diagnosis of benign and malignant diseases.
Keywords:Core-needle biopsy  Fine-needle aspiration  Thyroid nodules  Color-doppler
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏