首页 | 本学科首页   官方微博 | 高级检索  
检索        

Experimental study on interbody fusion with CFR/PEFK
引用本文:石吉才,李家顺,等.Experimental study on interbody fusion with CFR/PEFK[J].中国人民解放军军医大学学报,2001,16(2):111-114.
作者姓名:石吉才  李家顺
作者单位:[1]DepartmentofOrthopedics,ChanghaiHospital,SecondMilitaryMedicalUniversity,Shanghai200433,China [2]Departm,ChanghaiHospital,SecondMilitaryMedicalUniversity,Shanghai200433,China
摘    要:Abstract Objective:To study the biocompatibility of CFR/PEEK composite in bone tissue after implanted in lumbar intervertebral space and to evaluate its role in the interbody fusion compared with allograft bone.Methods:Thirteen beagles were chosen among which 7 animals were implanted with the disk-like CFR/PEEK composite in the lumbar intervertebaral space and 6 were implanted with allograft bone,X-ray,QCT and histological examination were employed at 6,12,and 24 months postoperatively.Results:The X-ray results were in conformity with that of QCT.Histological examination showed the anterior soft tissue of the implant exhibited a nonspecific foreign body reaction with connective tissue the biomaterials,Carbon fragment were seen in the surrounding tissue and some of the debric were phagocytosed by foreign body giant cell.Histological examination of bone and material showeb new bone growth alone the hole of CFR/PEEK implant.Conclusion:CFR/PEEK has excellent biocompatibility to bone tissue.

关 键 词:CFR  PEEK  体内融合  骨移植物  生物适合性
本文献已被 维普 等数据库收录!