首页 | 本学科首页   官方微博 | 高级检索  
检索        

不同龈下冲洗方式治疗牙周炎的临床对比研究
引用本文:聂瑞,;闫福华,;梁凌智,;武云霞.不同龈下冲洗方式治疗牙周炎的临床对比研究[J].中国现代医生,2014(29):120-122.
作者姓名:聂瑞  ;闫福华  ;梁凌智  ;武云霞
作者单位:[1]浙江省义乌杭州口腔医院门诊部牙周科,浙江义乌322000; [2]南京大学医学院附属口腔医院牙周科,江苏南京210008; [3]杭州口腔医院牙周科,浙江杭州310000; [4]山西医科大学第一医院口腔内科,山西太原030100
基金项目:江苏省科技发展计划项目(BL2013002)
摘    要:目的:探究与分析不同龈下冲洗方式治疗牙周炎的临床疗效。方法选取我院收治的中度及重度牙周炎患者23例(共88颗)采取随机数字表法进行分组。对照组给予传统超声龈下刮治后冲洗器给药治疗,试验组给予超声龈下刮治同步药物冲洗治疗,比较两种方法的临床疗效。结果两组治疗后菌斑指数(PL)、探诊出血指数(SBI)各数值较治疗前明显降低,差异有统计学意义(P〈0.05)。而试验组治疗后菌斑指数(PL)、探诊出血指数(SBI)、探诊深度(PD)、附着丧失(AL)各数值降低程度明显大于对照组,差异有统计学意义(P〈0.05)。试验组满意度明显高于对照组,差异有统计学意义(P〈0.05)。结论超声龈下刮治同步药物冲洗治疗牙周炎的临床疗效显著,值得广泛推广。

关 键 词:龈下冲洗  牙周炎  超声  疗效

Clinical comparative study of different subgingival rinse methods in treat-ment of periodontitis
Institution:NIE Rui, YAN Fuhua, LIANG Lingzhi, WU Yunxia (1.Department of Outpatient Periodontics, Yiwu Branch of Hangzhou Stomatology Hospital in Zhejiang Province, Yiwu 322000, China; 2. Department of Periodontics, Affiliated Stomatology Hospital of Medical School of Nanjing University, Nanjing 210008, China; 3. Department of Periodontics, Hangzhou Stomatology Hospital, Hangzhou 322000, China; g. Departmem of Oral Medicine, the First Hospital of Shanxi Medical University, Taiyuan 030100, China)
Abstract:Objective To explore and analyze the clinical efficacy of different subgingival rinse methods in the treat-ment of periodontitis. Methods Twenty-three patients (88 teeth) with moderate and severe periodontitis admitted to our hospital were divided into different groups using the random number table method. The control group was given drug administration treatment using the rinser after traditional ultrasound subgingival scaling and the experimental group was given drug rinse treatment synchronized with ultrasound subgingival scaling. The clinical efficacy of the two methods was compared. Results After the treatment, the numerical values of plaque indices (PL) and sulcus bleeding indices (SBI) of both groups decreased significantly compared to those before the treatment, with statistical significance (P〈0.05). After the treatment, the experimental group was significantly larger than the control group in the decrease degrees of numerical values of PL, SBI, probing depth (PD) and attachment loss (AL), with statistical significance (P〈0.05). The experimental group had higher satisfaction degree than the control group, with statistical significance (P〈0.05). Conclu-sion Drug rinse treatment synchronized with ultrasound subgingival scaling has remarkable clinical efficacy in the treatment of periodontitis, thereby worthy of wide promotion.
Keywords:Subgingival rinse  Periodontitis  Ultrasound  Efficacy
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号