首页 | 本学科首页   官方微博 | 高级检索  
检索        

A comparison of clinical and angiographic outcomes after Excel bioabsorbable polymer versus Firebird durable polymer rapamycin-eluting stent for the treatment of coronary artery disease in a “real world” setting: six-month follow-up results
作者姓名:Liu HB  Xu B  Qiao SB  Yang YJ  Ma WH  Qin XW  Yao M  Wu YJ  Yuan JQ  Chen J  You SJ  Dai J  Xia R  Li JJ  Chen JL  Gao RL
作者单位:Department of Cardiology, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100037, China 
摘    要:Background Several clinical trials have shown that rapamycin-eluting stents significantly reduce the risk of restenosis after percutaneous coronary intervention (PCI). The Firebird stent and the Excel stent (coated with bioabsorbable polymer) are two different types of rapamycin-eluting stents made in China, both have been recently approved for clinical use in China by State Food and Drug Administration. However, it is unclear whether there are differences in safety and efficacy between the two types of stents in daily practice. Methods In the month of June 2006, a total of 190 consecutive patients were treated exclusively with Firebird stents (n=93, Firebird group) or Excel stents (n=97, Excel group) in our center and were included in this study. The frequency of major adverse cardiac events (MACE, a composite of death, myocardial infarction or target lesion revascularization), binary restenosis, and late lumen loss and stent thrombosis during a six-month follow-up period were compared between the two groups.Results Patient and lesion characteristics were comparable between the groups. Major adverse cardiac event rates were low in hospital and at 6 months (2.1% in the Excel group and 0% in the Firebird group, P﹥0.05). The 6-month angiographic in-stent restenosis rate was 0% in both groups, with an associated late loss of (0.15 ± 0.21) mm versus (0.14 ± 0.20) mm (P=0.858) and the in-segment restenosis rate was also 0% for the Excel group and the Firebird group. There was no definite stent thrombosis identified in either group during the six-month follow-up period and only one patient in the Excel group had probable stent thrombosis in hospital. Conclusions Results from this mid-term, single-center study showed that both of the Firebird and the Excel rapamycin eluting stent had similar effects on reducing the incidence of MACE and the risk of restenosis (both in-stent and in-segment binary restenosis) after PCI in daily practice.

关 键 词:雷帕霉素  药物洗脱内支架  冠状动脉疾病  治疗  生物吸收性聚合物支架  火鸟牌持久性聚合物支架  疗效比较  血管造影  随访
收稿时间:2007-02-10

A comparison of clinical and angiographic outcomes after Excel bioabsorbable polymer versus Firebird durable polymer rapamycin-eluting stent for the treatment of coronary artery disease in a "real world" setting: six-month follow-up results
Liu HB,Xu B,Qiao SB,Yang YJ,Ma WH,Qin XW,Yao M,Wu YJ,Yuan JQ,Chen J,You SJ,Dai J,Xia R,Li JJ,Chen JL,Gao RL.A comparison of clinical and angiographic outcomes after Excel bioabsorbable polymer versus Firebird durable polymer rapamycin-eluting stent for the treatment of coronary artery disease in a "real world" setting: six-month follow-up results[J].Chinese Medical Journal,2007,120(7):574-577.
Authors:Liu Hai-bo  Xu Bo  Qiao Shu-bin  Yang Yue-jin  Ma Wei-hua  Qin Xue-wen  Yao Min  Wu Yong-jian  Yuan Jin-qing  Chen Jue  You Shi-jie  Dai Jun  Xia Ran  Li Jian-jun  Chen Ji-lin  Gao Run-lin
Institution:Department of Cardiology, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100037, China
Abstract:BACKGROUND: Several clinical trials have shown that rapamycin-eluting stents significantly reduce the risk of restenosis after percutaneous coronary intervention (PCI). The Firebird stent and the Excel stent (coated with bioabsorbable polymer) are two different types of rapamycin-eluting stents made in China, both have been recently approved for clinical use in China by State Food and Drug Administration. However, it is unclear whether there are differences in safety and efficacy between the two types of stents in daily practice. METHODS: In the month of June 2006, a total of 190 consecutive patients were treated exclusively with Firebird stents (n = 93, Firebird group) or Excel stents (n = 97, Excel group) in our center and were included in this study. The frequency of major adverse cardiac events (MACE, a composite of death, myocardial infarction or target lesion revascularization), binary restenosis, and late lumen loss and stent thrombosis during a six-month follow-up period were compared between the two groups. RESULTS: Patient and lesion characteristics were comparable between the groups. Major adverse cardiac event rates were low in hospital and at 6 months (2.1% in the Excel group and 0% in the Firebird group, P > 0.05). The 6-month angiographic in-stent restenosis rate was 0% in both groups, with an associated late loss of (0.15 +/- 0.21) mm versus (0.14 +/- 0.20) mm (P = 0.858) and the in-segment restenosis rate was also 0% for the Excel group and the Firebird group. There was no definite stent thrombosis identified in either group during the six-month follow-up period and only one patient in the Excel group had probable stent thrombosis in hospital. CONCLUSIONS: Results from this mid-term, single-center study showed that both of the Firebird and the Excel rapamycin eluting stent had similar effects on reducing the incidence of MACE and the risk of restenosis (both in-stent and in-segment binary restenosis) after PCI in daily practice.
Keywords:percutaneous coronary intervention  drug-eluting stent  bioabsorbable polymer  comparative study
本文献已被 万方数据 PubMed 等数据库收录!
点击此处可从《中华医学杂志(英文版)》浏览原始摘要信息
点击此处可从《中华医学杂志(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏