首页 | 本学科首页   官方微博 | 高级检索  
检索        


Procedural results and 30-day clinical events analysis following Edwards transcatheter aortic valve implantation in 48 consecutive patients: initial experience
Authors:Zhao Quan-Ming  Lognone Therese  Ivascau Calin  Sabatier Remi  Roule Vincent  Dahdouh Ziad  Massetti Massimo  Grollier Gilles
Institution:Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China.
Abstract:Background Transcatheter aortic valve implantation (TAVI) is a rapidly evolving strategy for therapy of aortic stenosis.We presented the procedural results and analyzed the death causes of 30-day mortality and clinical events in patients who underwent TAVI with Edwards prosthetic valves in University Hospital of Caen,France.Methods The patients with severe aortic stenosis but at high surgical risk or inoperable were considered as candidates for TAVI.Forty-eight patients undergoing TAVI from July 2010 to September 2011 were enrolled in this registry.The Edwards prosthetic valves were solely used in this clinical trial.Results Overall 48 patients underwent TAVI,28 of which accepted TAVI by trans-femoral (TF) approaches,20 by trans-apical approaches (TA).The aortic valve area (AVA) was (0.70±0.23) cm2,left ventricular ejection fraction (LVEF)was (57.4±17.6)%,Log EuroSCORE was (19.2±15.8)%,mean gradient was (47.0±16.6) mmHg.There were no significant differences between TF and TA groups in all these baseline parameters.Device success rate was 95.8%,and procedural success rate was 93.7% in total.Procedural mortality was 6.7% (3/48):two deaths in TA group (10%),and one death in TF group (3.6%).Forty-six Edwards valves were implanted:10 Edwards Sapien and 36 Edwards XT.Procedure-related complications included cardiac tamponade in 2 cases (4.2%),acute myocardial infarction (AMI) in 1 case (2.1%),permanent pacemaker implantation in 1 case (2.1%),life-threatening and major bleeding in 3 cases; access site related major complication in 1 case,AKI stage 3 in 3 cases (6.3%),minor stroke in 1 case (2.1%).Thirty-day survival rate was 89.6%.There were 5 deaths in total (10.4%):4 in TA group (20%) and 1 in TF group (3.6%).Conclusion The procedural success rate and 30-day mortality were acceptable in these high risk patients with Edwards prosthetic valves in the first 48 TAVI.
Keywords:aortic stenosis  transcatheter aortic valve implantation  registry
本文献已被 PubMed 等数据库收录!
点击此处可从《中华医学杂志(英文版)》浏览原始摘要信息
点击此处可从《中华医学杂志(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号