首页 | 本学科首页   官方微博 | 高级检索  
检索        

Ozone Emitted During Copying Process -A Potential Cause of Pathological Oxidative Stress and Potential Oxidative Damage in the Bodies of Operators
作者姓名:Zhou JF  Chen WW  Tong GZ
作者单位:JUN-FU ZHOU*,1,WEI-WEI CHEN*,AND GUI-ZHONG TONG# *The Second Affiliated Hospital,College of Medicine,Zhejiang University,88 Jiefang Road,Hangzhou 310009,Zhejiang,China; #Zhejiang Provincial Health and Epidemic Prevention Station,17 Laozhedazhi Road,Hangzhou 310009,Zhejiang,China
摘    要:INTRODUCTION Copying of references, documents, information and photos plays important roles in social, economic, business, scientific and technological affairs, however, photochemical smog emitted during this process may become risk factors inducing potential oxidative 1Correspondence should be addressed to Prof. Jun-Fu ZHOU, Second Affiliated Hospital of College of Medicine, Zhejiang University, 88 Jiefang R…

关 键 词:复印从业人员  空气污染  臭氧  氧化损伤  病理改变

Ozone emitted during copying process--a potential cause of pathological oxidative stress and potential oxidative damage in the bodies of operators
Zhou JF,Chen WW,Tong GZ.Ozone Emitted During Copying Process -A Potential Cause of Pathological Oxidative Stress and Potential Oxidative Damage in the Bodies of Operators[J].Biomedical and Environmental Sciences,2003,16(2):95-104.
Authors:Zhou Jun-Fu  Chen Wei-Wei  Tong Gui-Zhong
Institution:The Second Affiliated Hospital, College of Medicine, Zhejiang University, 88 Jiefang Road, Hangzhou 310009, Zhejiang, China. zhuojun88@sina.com
Abstract:To estimate the impact of copying on the indoor air quality, and to investigate whether ozone emitted during such a process induces pathological oxidative stress and potential oxidative damage in the bodies of operators. Methods 67 copying operators (CO) and 67 healthy volunteers (HV) were enrolled in a random control study, in which levels of lipoperoxide (LPO) in plasma and erythrocytes, and levels of vitamin C (VC), vitamin E (VE) and b-carotene (b-CAR) in plasma as well as activities of superoxide dismutase (SOD), catalase (CAT) and glutathione peroxidase (GPX) in erythrocytes were determined by spectrophotometric methods. Results Compared with the HV group, the average values of LPO in plasma and erythrocytes in the CO group were significantly increased (P<0.0001), while those of VC, VE and b-CAR in plasma as well as those of SOD, CAT and GPX in erythrocytes in the CO group were significantly decreased (P<0.0001). Pearson product-moment correlation analysis showed that with increase of ozone level in copying sites and duration of exposure to ozone, the values of LPO in plasma and erythrocytes in the bodies of operators were gradually increased,while those of VC, VE, b-CAR, SOD, CAT and GPX were decreased in the same manner. Odds ratio (OR) of risk of biochemical parameters reflecting potential oxidative damage of the copying operators ranged from 4.440 to 13.516, and 95 % CI of OR was from 2.113 to 34.061. Reliability coefficient () of the biochemical parameters used to reflect the potential oxidative damage of the operators was 0.8156, standardized item =0.9929, P<0.0001. Conclusion Findings in the present study suggest that there exist a series of free radical chain reactions and pathological oxidative stress induced by high dose ozone in the operators, thereby causing potential oxidative and lipoperoxidative damages in their bodies.
Keywords:Ozone  Oxidation  Lipoperoxidation  Antioxidant  Antioxidase  Oxidative stress  Oxidative damage  Copying  Copying operators  Copier  
本文献已被 CNKI 万方数据 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号