首页 | 本学科首页   官方微博 | 高级检索  
检索        

高效液相色谱法检测心肌细胞蛋白降解率
引用本文:陈保林,马跃东,熊肇军,张成喜,刘晨,董吁钢.高效液相色谱法检测心肌细胞蛋白降解率[J].重庆医学,2011,40(22):2234-2235,2290.
作者姓名:陈保林  马跃东  熊肇军  张成喜  刘晨  董吁钢
作者单位:陈保林,Chen Baolin(贵州省人民医院心内科,贵阳,550002);马跃东,Ma Yuedong(中山大学附属第一医院心血管医学部,广州,510080);熊肇军,张成喜,Xiong Zhaojun,Zhang Chengxi(中山大学附属第三医院心内科,广州,510630);刘晨,董吁钢,Liu Chen,Dong Yugang(中山大学附属第一医院心血管医学部,广州,510080;卫生部辅助循环重点实验室,广州,510080)
摘    要:目的建立一种快速测定心肌细胞3-甲基组氨酸(3-MH)释放量的方法。方法分离培养新生大鼠心肌细胞。细胞培养液样品用乙腈沉淀蛋白,离心后取上清液进样用于3-MH分析。3-MH检测采用岛津LC-20A高效液相色谱仪,用C18色谱柱分离,外标法定量,检测波长为338 nm。结果色谱峰分离良好,线性方程为:y=731 241x+896.86,相关系数(r)=0.999 8,3-MH线性检测范围为1.6~107.0μmol/L。结论该实验为检测心肌细胞蛋白降解提供了一种精确、简单、可行的方法。

关 键 词:肌细胞  心脏  色谱法  高压液相  甲基组氨酸类

Determination of protein degradation in cardiomyocytes by high performance liquid chromatography
Chen Baolin,Ma Yuedong,Xiong Zhaojun,Zhang Chengxi,Liu Chen,Dong Yugang.Determination of protein degradation in cardiomyocytes by high performance liquid chromatography[J].Chongqing Medical Journal,2011,40(22):2234-2235,2290.
Authors:Chen Baolin  Ma Yuedong  Xiong Zhaojun  Zhang Chengxi  Liu Chen  Dong Yugang
Institution:2,4(1.Department of Cardiology,the People’s Hospital of Guizhou Province,Guiyang 550002,China;2.Department of Cardiology,the First Affiliated hospital of Sun Yat-Sen University,Guangzhou 510080,China;3.Department of Cardiology,the Third Affiliated Hospital of Sun Yat-Sen University,Guangzhou 510630,China;4.Key Laboratory on Assisted Circulation of Ministry of Health,Guangzhou 510630,China)
Abstract:Objective To establish a fast method to determine the release of 3-methylhistidine(3-MH) in cardiomyocytes.Methods Neonatal SD rat cardiomyocytes were isolated and cultured.The analytes in culture medium were extracted by protein precipitation using acetonitrile.High performance liquid chromatographic detection was used to determine the 3-MH levels in medium by applying Shimadzu High-Performance Liquid Chromatograph.Chromatographic separation was performed on a C18 column.The monitor wave-length was 338 nm.Results The chromatography was well separative.Linear equation was:y=731 241X+896.86,r=0.999 8.The calibration curve was linear in the range of 1.6-107.0 μmo/L for 3-MH,with correlation coefficient above 0.99.Conclusion The method is accurate,precise and reliable for the determination of protein degradation in cardiomyocytes.
Keywords:myocytes  cardiac  chromatography  high pressure liquid  methylhistidines
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号