首页 | 本学科首页   官方微博 | 高级检索  
检索        

USCOM检测危重症新生儿左心功能的临床研究
引用本文:张苹琳,严学渝,苏丽君,杨义,姜汝勇,汤正珍.USCOM检测危重症新生儿左心功能的临床研究[J].中国现代医学杂志,2022(8):64-68.
作者姓名:张苹琳  严学渝  苏丽君  杨义  姜汝勇  汤正珍
作者单位:遵义市第一人民医院(遵义医科大学第三附属医院) 新生儿科, 贵州 遵义 563002
基金项目:贵州省科技计划项目(No:20191327);遵义市汇川区科技计划项目(No:2016025)
摘    要:目的 研究超声心输出量监测仪(USCOM)评定危重症新生儿左心功能的临床价值。方法 选取2017年1月—2018年12月遵义市第一人民医院收治的危重症新生儿73例作为研究对象。按照患儿有无休克分为无休克组和休克组,分别有34例和39例。另选取同期来该院体检的37例健康新生儿作为对照组。各组均应用USCOM监测左心功能,观察USCOM对危重症新生儿左心功能的临床评定价值。结果 各组心率、射血分数比较,差异无统计学意义(P >0.05)。休克组每搏输出量、每搏输出量指数、心输出量及心脏指数低于对照组和无休克组(P <0.05),无休克组每搏输出量、每搏输出量指数、心输出量及心脏指数低或短于对照组(P <0.05)。休克组速度峰值、速度时间积分及流动时间低或短于对照组和无休克组(P <0.05),外周阻力和血管阻力指数高于对照组和无休克组(P <0.05);无休克组速度峰值、速度时间积分和流动时间低于对照组(P <0.05),外周阻力和血管阻力指数高于对照组(P <0.05)。结论 USCOM可有效监测危重症新生儿左心功能,分析患儿血流情况,为临床制订防治措施提供有力依据,值得临床应用及推广。

关 键 词:超声检查  心功能  危重病  婴儿,新生
收稿时间:2021/11/30 0:00:00

Clinical value of USCOM in assessing left ventricular function of critically ill neonates
Ping-lin Zhang,Xue-yu Yan,Li-jun Su,Yi Yang,Ru-yong Jiang,Zheng-zhen Tang.Clinical value of USCOM in assessing left ventricular function of critically ill neonates[J].China Journal of Modern Medicine,2022(8):64-68.
Authors:Ping-lin Zhang  Xue-yu Yan  Li-jun Su  Yi Yang  Ru-yong Jiang  Zheng-zhen Tang
Institution:Department of Neonatology, The First People''s Hospital of Zunyi (The Third Affiliated Hospital of Zunyi Medical University), Zunyi, Guizhou 563002, China
Abstract:Objective To study the value of ultrasonic cardiac output monitor (USCOM) in assessing the left ventricular function of critically ill neonates.Methods Seventy-three critically ill neonates admitted to our hospital from January 2017 to December 2018 were selected and assigned to non-shock group (n = 34) and shock group (n = 39) according to the presence or absence of shock. Another 37 healthy neonates undergoing physical examinations in our hospital during the same period were enrolled as control group. USCOM was applied to monitor the left ventricular function, and the its clinical value for assessing the left ventricular function of critically ill neonates was analyzed.Results There was no difference in heart rate and ejection fraction among the groups (P > 0.05). The stroke volume, stroke volume index, cardiac output and cardiac index in the shock group were lower than those in the control group and the non-shock group (P < 0.05), and they were even lower in the non-shock group compared with the control group (P < 0.05). The peak velocity, velocity time integral, and flow time were lower, but the peripheral resistance and vascular resistance index were higher in the shock group than those in the control group and non-shock group (P < 0.05). Compared with the control group, the peak velocity, velocity time integral, and flow time were lower, but the peripheral resistance and vascular resistance index were higher in the non-shock group (P < 0.05).Conclusions USCOM is able to effectively monitor the left ventricular function and analyze the hemodynamics of critically ill neonates, thereby providing references for clinical interventions. Thus, USCOM should be more widely adopted in the clinical practice.
Keywords:ultrasonography  cardiac function  critically illness  neonates
点击此处可从《中国现代医学杂志》浏览原始摘要信息
点击此处可从《中国现代医学杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号