95°接骨板与逆行髓内钉治疗股骨髁上骨折生物力学研究
引用本文:宋建新,胡军,郑诚功,郑承泽,林楚平,吴杰,杜世新,李文胜,陈瞬亮,邱开封,罗绍伟.95°接骨板与逆行髓内钉治疗股骨髁上骨折生物力学研究[J].汕头大学医学院学报,2006,19(1):35-36.
作者姓名:宋建新  胡军  郑诚功  郑承泽  林楚平  吴杰  杜世新  李文胜  陈瞬亮  邱开封  罗绍伟
作者单位:1. 汕头大学医学院第一附属医院骨科,广东,汕头,515041
2. 国立阳明大学医学工程研究所,台湾,台北
摘    要:目的:研究股骨远端逆行髓内钉与动力髁(DCS)固定股骨髁上骨折的生物力学特征,比较两种内固定物固定股骨远端骨折的初期稳定度。方法:15具人造股骨随机分为逆行髓内钉组、DCS组和对照组(每组各5具),逆行髓内钉组与DCS组制作髁上骨折模型后分别应用逆行髓内钉固定及接骨板固定,对照组股骨不作任何处理,应用生物力学测试仪进行轴向加压与扭转测试,比较各组轴向与扭转刚度。结果:在股骨远端骨折的固定中,逆行髓内钉可以提供与DCS接骨板相同程度的初期稳定度。结论:逆行髓内钉与DCS接骨板具有相似的轴向与扭转刚度,逆行髓内钉适用于关节外股骨远端骨折。

关 键 词:骨折  内固定  髓内钉  生物力学
文章编号:1007-4716(2006)01-0035-02
修稿时间:2005年12月2日

Biomechanics Study on Internal Fixation for Supracondylar Fracture of Femur with 95 Degree Plate and Retrograde Intramedullar Nail
SONG Jian-xin,HU Jun,ZHENG Cheng-gong,ZHENG Cheng-ze,LIN Chu-ping,WU Jie,DU Shi-xin,LI Wen-sheng,CHEN Sun-liang,QIU Kai-feng,LUO Shao-wei.Biomechanics Study on Internal Fixation for Supracondylar Fracture of Femur with 95 Degree Plate and Retrograde Intramedullar Nail[J].Journal of Shantou University Medical College,2006,19(1):35-36.
Authors:SONG Jian-xin  HU Jun  ZHENG Cheng-gong  ZHENG Cheng-ze  LIN Chu-ping  WU Jie  DU Shi-xin  LI Wen-sheng  CHEN Sun-liang  QIU Kai-feng  LUO Shao-wei
Abstract:Objective:To study the biomechanics on internal fixation for supracondylar fracture of femur with 95 degree plate and retrograde intramedullar nail,and to investigate the fixation stable of the plate and retrograde intramedullar nail.Methods:The 15 artificial femur models were divided into DCS group,retrograde intramedullar nail group and control group.The artificial femurs of DCS group and retrograde intramedullar nail group were performed supracondylar fracture and fixed with 95 degree plate and retrograde intramedullar nail.The artificial models of three groups were test to investigate axial and torsional stiffness by bionix858 test system.Results:The stability would be satisfied in the internal fixation for the fracture of femur with retrograde intramedullar nail.The stable degree was the same as the DCS group in the early stage of fracture fixation.Conclusion:The axial and torsional stiffness are same between DCS and retrograde intramedullar nail.The retrograde intramedullar nail is ideal choice in fixation for supracondylar fracture of femur.
Keywords:fracture  internal fixation  intramedullar nail  biomechanics
本文献已被 CNKI 万方数据 等数据库收录!