A comparable study of clinical and optical outcomes after 1.8, 2.0 mm microcoaxial and 3.0 mm coaxial cataract surgery
Authors:Yi-Bo Yu  Ya-Nan Zhu  Wei Wang  Yi-Dong Zhang  Yin-Hui Yu and Ke Yao
Institution:Eye Center, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang Province, China; Zhejiang Provincial Key Lab of Ophthalmology, Hangzhou 310009, Zhejiang Province, China;Eye Center, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang Province, China;Eye Center, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang Province, China;Eye Center, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang Province, China;Eye Center, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang Province, China;Eye Center, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang Province, China; Zhejiang Provincial Key Lab of Ophthalmology, Hangzhou 310009, Zhejiang Province, China
Abstract:AIM: To evaluate the clinical and optical outcomes after clear corneal incision cataract surgery (CICS) with three different incision sizes (1.8, 2.0 and 3.0 mm). METHODS: Eyes of 150 patients with age-related cataract scheduled for coaxial cataract surgery were randomized to three groups: 1.8, 2.0, or 3.0 mm CICS. Intraoperative data and postoperative outcomes including surgically induced astigmatism (SIA), the corneal incision thickness, wavefront aberrations and modulation transfer function (MTF) of cornea were obtained. RESULTS: There were no significant differences among the three groups in demographic characteristics and intraoperative outcome. The 1.8 and 2.0 mm microincisions showed more satisfactory clinical outcomes than the 3.0 mm incision. The 1.8 mm incision showed significantly less SIA than the 2.0 mm incision until postoperative 1mo (P<0.05), but the difference was only 0.14-0.18 D. Combined with less increased incision thickness only at postoperative 1d (P=0.013), the 1.8 mm incision presented better uncorrected distance visual acuity (UCDVA) than the 2.0 mm incision only at 1d postoperatively (P=0.008). For higher-order aberrations and other Zernike coefficients, there were no significant differences between the 1.8 mm group and 2.0 mm group (P>0.05). CONCLUSION: Converting from 3.0 mm CICS to 1.8 or 2.0 mm CICS result in better clinical and optical outcomes. However, when incision is 1.8 mm, the benefits from further reduction in size compared with 2.0 mm are limited. The necessity to reduce the incision size is to be deliberated.
Keywords:microsurgery  phacoemulsification  treatment outcome
点击此处可从《国际眼科杂志(英文版)》浏览原始摘要信息
点击此处可从《国际眼科杂志(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号