首页 | 本学科首页   官方微博 | 高级检索  
检索        

联合多种视功能检查对原发性开角型青光眼早期诊断的意义
引用本文:蓝育青,葛坚.联合多种视功能检查对原发性开角型青光眼早期诊断的意义[J].眼科学报,1998,14(4):199-203,235.
作者姓名:蓝育青  葛坚
作者单位:[1]中山医科大学孙逸仙纪念医院眼科 [2]中山医科大学中山眼科中心
摘    要:了解原发性开角型青光眼视觉电生理和计算机自动视野检查结果的变化特征并对其视功能状况进行综合分析以寻找比较敏感和特异的参数,为原发性开角型青光眼较早期和早期诊断提供依据。方法:对36例原发性开角型青光眼患者,8例可疑性青光眼患者,30例正常对照者分别进行视网膜振荡电位,视网膜电图,视诱发电位和Humphery计算机自动视野检查。

关 键 词:视觉  电生理  自动视野检查  开角型青光眼  诊断

The Significance of Combination of Electrophysiology and Automated Perimetry Tests on the Early Diagnosis of Primary Open Angle Glaucoma
Y Lan,J Ge,Y Liu.The Significance of Combination of Electrophysiology and Automated Perimetry Tests on the Early Diagnosis of Primary Open Angle Glaucoma[J].Eye Science,1998,14(4):199-203,235.
Authors:Y Lan  J Ge  Y Liu
Institution:Department of Ophthalmology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University of Medical Sciences, Guangzhou 510120, China.
Abstract:OBJECTIVE: The study was designed to analyze the relationship among the three electrophysiological tests and visual fields in primary open angle glaucoma (POAG) in order to find some more sensitive and specific parameters in earlier and early diagnosis of patients with POAG. METHODS: Thirty-six(70 eyes) patients with POAG, 8(12 eyes) glaucoma suspects and 30 (60 eyes) normal subjects underwent pattern electroretinogram (PERG), oscillatory potentials (OPs), pattern visual evoked potentials (PVEP) and Humphery automated perimetry tests respectively. RESULTS: The abnormal rate of PERG was the highest among the three electrophysiological tests in the glaucoma suspects and those of PERG and automated perimetry results were higher than others after early stage. In the correlation analysis of all objects, the amplitude of PERG had negative correlated with IOP and visual indices, but no correlation with C/D and VA. OPs had negative correlated with C/D, and no correlation with visual fields indices, intraocular pressure (IOP) and visual acuity (VA). The latency of PVEP had positive correlation with visual fields indices and C/D, but no correlation with IOP. CONCLUSION: Statistical result showed that different parameters could be selected according to different appearance of POAG. In the earlier stage before visual field defects could be found, PERG would be a more sensitive indicator if IOP were high; once C/D was abnormal, OPs and PVEP would be the better signs even though IOP was normal. PERG and Humphery automated perimetry were very useful indicators after early stage. It was significant in combination of many visual function tests on earlier or early diagnosis of POAG.
Keywords:visual electrophysiology  automated perimetry  glaucoma
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号