The elastic properties of the lens capsule in capsulorhexis
Authors:E I Assia  D J Apple  J C Tsai  E S Lim
Institution:Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston 29425.
Abstract:We investigated the ability of the anterior lens capsule to stretch and allow removal of lens substance and intraocular lens implantation through a continuous circular capsulorhexis. Capsulorhexis of various sizes (2.5 to 7.5 mm) were performed in 50 eyes obtained post mortem from 31 patients. The nucleus and cortex were removed by either phacoemulsification (35 eyes) or manual extracapsular cataract extraction (15 eyes). The opening of the capsule was then gradually enlarged, using a modified caliper with two pins attached to its tips, until the margins were torn. The capsule was torn when the circumference at the time of rupture was 1.6 times larger than the circumference of the original circular capsulectomy or 5.0 times larger than the diameter of the capsulectomy. Manual extraction of a lens nucleus with profile circumference (sagittal or anteroposterior) of 18.0 to 22.0 mm can be performed through a 5.5-mm opening and a 6.0- to 7.0-mm optic intraocular lens (profile circumference of 13.0 to 17.0 mm) can be implanted through a 4.5-mm capsulectomy.