首页 | 本学科首页   官方微博 | 高级检索  
检索        

应用4DCT研究乳腺癌根治术后胸壁IMRT的放射物理学优势
引用本文:王文岩,肖志清,王艳强,张玉峰,郭晗,薛晓英.应用4DCT研究乳腺癌根治术后胸壁IMRT的放射物理学优势[J].中华放射肿瘤学杂志,2013,23(2):152-155.
作者姓名:王文岩  肖志清  王艳强  张玉峰  郭晗  薛晓英
作者单位:050000 石家庄,河北医科大学第二医院放疗科(王文岩、张玉峰、薛晓英),物理室(肖志清、王艳强、郭晗)
摘    要:目的 探讨根治术后乳腺癌胸壁IMRT时为克服呼吸运动影响应用4DCT确定靶区的临床价值。方法 对入组的17例乳腺癌根治术后患者序贯进行常规CT和4DCT扫描并采集图像,分别勾画靶区和正常组织。根据每位患者的3D、4D靶区分别制定3D计划和4D计划,并将3D计划按等中心坐标直接复制到4D靶区上比较差异及OAR剂量学变化,并行配对t检验或Wilcoxon符号秩检验。结果 自由呼吸状态下呼吸运动导致PTV4D较PTV3D平均增大(10.35±4.80)%(P=0.000),V100、V95、V90、D95、D90、Dmin分别降低(0.78~18.0)%(P=0.000)、(0.01~3.90)%(P=0.000)、(0~2.12)%(P=0.000)、(13~222) cGy (P=0.000)、(1~118) cGy (P=0.000)、(6~1910) cGy (P=0.000)。而呼吸运动对患侧肺V20、V10、V5、Dmean和心脏V30影响不明显(P=0.288、0.407、0.435、0.758、0.575)。

关 键 词:乳腺肿瘤/术后放射疗法  呼吸运动  四维治疗计划  
收稿时间:2013-05-20

The radiation physics advantages of 4DCT on intensity-modulated radiotherapy of chest wall after radical mastectomy
Wang Wenyan,Xiao Zhiqing,Wang Yanqiang,Zhang Yufeng,Guo Han,Xue Xiaoying.The radiation physics advantages of 4DCT on intensity-modulated radiotherapy of chest wall after radical mastectomy[J].Chinese Journal of Radiation Oncology,2013,23(2):152-155.
Authors:Wang Wenyan  Xiao Zhiqing  Wang Yanqiang  Zhang Yufeng  Guo Han  Xue Xiaoying
Institution:Department of Radiation Oncology, Second Hospital of Hebei Medical University, Shijiazhuang 050000, China
Abstract:Objective To invesigate the influence of breathing motion on intensity-modulated radiotherapy (IMRT) of chest wall after radical mastectomy, and explore clinical value of accurately determined target volume. Methods A total of 17 radical mastectomy patients underwent 3DCT simulation scans sequentially followed by 4DCT simulation scans during free breathing. The targets and normal organs was determined based on CT images respectively. Three sets of radiotherapy plan were designed for each patient:plan 3D, plan 4D and plan 3D-A. The Plan 3D and plan 4D was designed based on 3D and 4D targets respectively. Plan 3D was copied to 4D target with the same isocenter coordinates. The dose distribution was calculated separately to evaluate the dose-volume histograms parameters for PTV, ipsilateral lung and heart, respectively. Two planning parameters was compared with paired t-test or Wilcoxon sign-rank test.Results The average volume of PTV4D was (10.35±4.80)% larger than PTV3D (P=0.000). Compared with plan 3D, the V100, V95, V90, D95, D90, Dmin of plan 3D-A were reduced, that were (0.78—18.0)%(P=0.000),(0.01—3.90)%(P=0.000),(0—2.12)%(P=0.000),(13—222) cGy (P=0.000),(1—118) cGy (P=0.000),(6—1910) cGy (P=0.000). However, the V20, V10, V5, Dmean of the ipsilateral lung and V30 of heart were same between 3D plan and 4D plan (P=0.288,0.407,0.435,0.758,0.575). Conclusions The respiratory motion may reduce the target dose and its coverage in chest wall treatments, so 4DCT plan could accurately define target volume without increasing the exposure dose of normal tissues.
Keywords:Breast neoplasms/postoperative radiotherapy  Respiratory movement  Four-dimensional treatment planning  
点击此处可从《中华放射肿瘤学杂志》浏览原始摘要信息
点击此处可从《中华放射肿瘤学杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号