A biomechanical comparison of proximal femoral nails and locking proximal anatomic femoral plates in femoral fracture fixation: A study on synthetic bones
Authors:Korhan Ozkan  ?smail Türkmen  Adem Sahin  Yavuz Yildiz  Selim Erturk  Mehmet Salih Soylemez
Institution:Department of Orthopaedics and Traumatology, Faculty of Medicine, Istanbul Medeniyet University, Istanbul, Turkey;1Department of Orthopaedics and Traumatology, Istanbul Medeniyet University, GoztepeTraining and Research Hospital, Istanbul, Turkey;2Department of Orthopaedics and Traumatology, Corlu State Hospital, Istanbul, Turkey;3Department of Material and Metalurgia Engineering, Istanbul Technical University, Istanbul, Turkey
Abstract:Background:The incidence of fractures in the trochanteric area has risen with the increasing numbers of elderly people with osteoporosis. Although dynamic hip screw fixation is the gold standard for the treatment of stable intertrochanteric femur fractures, treatment of unstable intertrochanteric femur fractures still remains controversial. Intramedullary devices such as Gamma nail or proximal femoral nail and proximal anatomic femur plates are in use for the treatment of intertrochanteric femur fractures. There are still many investigations to find the optimal implant to treat these fractures with minimum complications. For this reason, we aimed to perform a biomechanical comparison of the proximal femoral nail and the locking proximal anatomic femoral plate in the treatment of unstable intertrochanteric fractures.Result:Nail and plate models were locked distally at the same level. Axial steady load with a 5 mm/m velocity was applied through the mechanical axis of femur bone models. Axial loading in the proximal femoral intramedullary nail group was 1.78-fold greater compared to the plate group. All bones that had the plate applied were fractured in the portion containing the distal locking screw.Conclusion:The proximal femoral intramedullary nail provides more stability and allows for earlier weight bearing than the locking plate when used for the treatment of unstable intertrochanteric fractures of the femur. Clinicians should be cautious for early weight bearing with locking plate for unstable intertrochanteric femur fractures.
Keywords:Biomechanical comparison  intertrochanteric femur fractures  intramedullary nail  proximal anatomic femoral plate
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号