首页 | 本学科首页   官方微博 | 高级检索  
检索        

掌侧与背侧钢板固定关节外桡骨远端背侧粉碎性骨折的生物力学研究
引用本文:周海涛,项舟,梁新刚,彭鲲,黄光平,李秀群,陈孟诗,黄学进.掌侧与背侧钢板固定关节外桡骨远端背侧粉碎性骨折的生物力学研究[J].中华手外科杂志,2009,25(1).
作者姓名:周海涛  项舟  梁新刚  彭鲲  黄光平  李秀群  陈孟诗  黄学进
作者单位:1. 四川大学华西医院骨科,成都,610041
2. 四川大学生物治疗国家重点实验室、干细胞与组织工程研究室
3. 四川大学生物力学工程实验室
摘    要:目的 探讨掌侧与背侧钢板固定桡骨远端背侧粉碎性骨折时的抗压缩、抗扭转差异性.方法 将12侧新鲜成人尸体桡骨标本制成桡骨远端背侧粉碎性骨折模型,随机分为2个大组,分别进行掌侧与背侧钢板螺钉固定;再将每个大组分为2个亚组,分别进行轴向压缩试验和水平扭转试验.检测指标:轴向压缩强度、轴向压缩刚度、水平扭转强度和水平扭转刚度.结果 在轴向压缩试验中,掌、背侧两组之间轴向压缩强度差异有统计学意义(P<0.05),背侧组大于掌侧组;在生理压缩载荷下,掌、背侧两组刚度值差异有统计学意义(P<0.05),背侧组高于掌侧组.在水平扭转试验中,两组水平扭转强度与扭转刚度差异都没有统计学意义,但数据显示,掌侧组都略强于背侧组.结论 在抗压缩方面,两组的压缩强度以及压缩刚度差异均有统计学意义,背侧组要优于掌侧组;而在抗旋转方面,两组的扭转强度与扭转刚度差异均无统计学意义,但掌侧组在数据上均稍大于背侧组.

关 键 词:生物力学  骨折  粉碎性  内固定器  桡骨远端骨折

Plate fixation for extra-articular dorsally comminuted distal radius fracture:a biomechanical comparison between volar plating and dorsal plating
ZHOU Hai-tao,XIANG Zhou,HANG Xin-gang,Peng Kun,HUANG Guang-ping,LI Xiu-qun,CHEN Meng-shi,HUANG Xue-jin.Plate fixation for extra-articular dorsally comminuted distal radius fracture:a biomechanical comparison between volar plating and dorsal plating[J].Chinses Journal of Hand Surgery,2009,25(1).
Authors:ZHOU Hai-tao  XIANG Zhou  HANG Xin-gang  Peng Kun  HUANG Guang-ping  LI Xiu-qun  CHEN Meng-shi  HUANG Xue-jin
Abstract:Objective To investigate the biomechanical differences in the aspects of anti-compression and anti-torsion of plate fixation applied through volar or dorsal approaches in the treatment of extra-articular distal radius fracture.Methods Dorsally comminuted distal radius fracture was created in 12 fresh cadaver radius specimens.The specimens were then randomly assigned to volar plating group and dorsal piing group,with 6 eack Plate fixation of the fracture WaS done via a volar approach and a dorsal approach respectively.Subsequently.each group was further divided into 2 subgroups to undergo axial compression and horizontal torsion test using MTS machine.The following parmneters were measured:axial compression strength axial compression rigidity,horizontal torsion strength,and horizontal torsion rigidity.Results The compression test showed statistically significant difference of compression strength between the volar and dorsal groups,that of the dorsal group being stronger.Similarly,there was statistically significant difference in the compression rigidity between these two groups,that of the dorsal group being stronger.In the torsion tests,however,we have noticed that although the torsion strength and rigidity of the volar group were slighfly stronger than those of the dorsal group,the diitemnce was not statistically significant.Conclusion Dorsal plating of dorsally corraninuted distal radius fracture yields significantly stronger anti-compressionfeatures comparingto volar plating.The anti-torsion features between volar plating and dorsal plating are comparable although the parameters of volar plating are slightly stronger.
Keywords:Biomechanics  Fractures  comminuted  Internal fixators  Distal radius fractures
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号