首页 | 本学科首页   官方微博 | 高级检索  
检索        

Vitek-2 Compact AST-GN13检测耐碳青霉烯鲍曼不动杆菌对左氧氟沙星药敏结果的准确性
引用本文:刘园,周万青,张之烽,孙静,沈瀚.Vitek-2 Compact AST-GN13检测耐碳青霉烯鲍曼不动杆菌对左氧氟沙星药敏结果的准确性[J].检验医学与临床,2016(19):2741-2742.
作者姓名:刘园  周万青  张之烽  孙静  沈瀚
作者单位:南京大学医学院附属鼓楼医院检验科 210008
基金项目:南京市卫生和计划生育委员会资助课题(YKK1006、YKK14052)。
摘    要:目的 探讨Vitek-2Compact AST-GN13对耐碳青霉烯鲍曼不动杆菌左氧氟沙星敏感性测定的准确性。方法 收集亚胺培南耐药鲍曼不动杆菌50株,以E-Test法为参考方法,分别用Vitek-2Compact AST-GN13药敏卡和纸片扩散(K-B)法对收集菌株进行左氧氟沙星敏感性检测,并评价3种方法结果的符合性。结果 共收集亚胺培南耐药鲍曼不动杆菌50株,E-Test法结果显示共有46株最低抑菌浓度(MIC)256mg/L,4株MIC=4mg/L;K-B法结果与E-Test法结果相符;Vitek-2Compact AST-GN13检测出现不同结果,其中4株菌株为敏感(≤2mg/L),36株为中介(4mg/L),10株为耐药(≥8mg/L)。K-B法与ETest法标准符合率(CA)为100%,Vitek-2Compact与E-Test法CA为20%,一般错误率为72%,严重错误率为8%。结论Vitek-2Compact AST-GN13检测耐碳青霉烯鲍曼不动杆菌对左氧氟沙星的敏感性时,可能会产生错误结果,日常工作中可采用E-Test与K-B法互为替代方法进行试验。

关 键 词:左氧氟沙星  耐碳青霉烯鲍曼不动杆菌  Vitek-2  Compact  AST-GN13

Accuracy investigation of Vitek-2 Compact AST-GN13 in detection of drug susceptibility of carbapenem-resistance Acinetobacter baumannii to levofloxacin
Abstract:Objective To investigate the accuracy of the automated system of Vitek-2 Compact for the detection of levofloxacin in carbapenem-resistance Acinetobacter baumannii .Methods Fifty strains of carbapenem-resistance Acinetobacter baumannii were collected .The susceptibility of carbapenem-resistance Acinetobacter baumannii to levofloxacin were determined by Vitek-2 Com-pact ,disk diffusion method and the E-Test method .E-Test method was used as the reference method for comparison .Results The susceptibility results to levofloxacin in E-Test method showed that 46 stains of resistant(> 256 mg/L)and 4 strains of intermediary (4 mg/L)in fifty strains of carbapenem-resistance Acinetobacter baumannii .The susceptibility of carbapenem-resistance Acineto-bacter baumannii to levofloxacin was consistent between disk diffusion method and E-Test method ,while different results showed in Vitek-2 Compact ,which included 4 stains of sensitive( ≤ 2 mg/L) ,36 strains of intermediary(4 mg/L)and 10 strains of resistant( ≥8 mg/L) .The disk diffusion method gave 100% category agreement(CA)with E-Test .While Vitek-2 Compact gave 20% with E-Test ,72% strains with minor errors ,8% strains with very major errors .Conclusion The Vitek-2 Compact system might not be suitable for the detection of levofloxacin in carbapenem-resistance Acinetobacter baumannii because of fault result causing ,the disk diffusion method could be used as an alternative method for E-Test in the experiment .
Keywords:levofloxacin  carbapenem-resistance Acinetobacter baumannii  Vitek-2 Compact AST-GN13
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号