首页 | 本学科首页   官方微博 | 高级检索  
检索        

三维K-空间Kz轴数据不对称填充技术在3D-TOF脑动脉MRA的应用价值
引用本文:刘定西,于群,熊茵,梁明,刘芳,孔祥泉,徐海波,石浩军,董道玉.三维K-空间Kz轴数据不对称填充技术在3D-TOF脑动脉MRA的应用价值[J].中国医学影像技术,2004,20(9):1437-1439.
作者姓名:刘定西  于群  熊茵  梁明  刘芳  孔祥泉  徐海波  石浩军  董道玉
作者单位:华中科技大学同济医学院协和医院放射科,湖北武汉,430022
摘    要:目的探讨3D K-空间Kz轴数据不对称填充方法在3D TOF脑动脉MRA的应用价值.方法 40例患者行Kz轴K-空间数据不对称填充的3D TOF脑动脉MRA(Turbo MRA)及Kz轴K-空间数据对称填充的3D TOF脑动脉MRA(常规MRA),在3D源图像和MIP图像上比较二种方法的影像质量、成像时间及显示血管的能力.结果 Kz轴不对称K-空间填充3D TOF脑动脉MRA与Kz轴对称K-空间填充3D TOF脑动脉MRA相比,影像质量指标(S/N、C/N、Rz)、采集时间TA、血管显示能力等均有显著性差异(P<0.01).结论 Kz轴K-空间不对称填充3D TOF脑动脉MRA与常规3D TOF脑动脉MRA相比成像质量更佳,显示血管更多,节约采集时间44%.

关 键 词:K-空间  Kz轴  不对称填充  时间飞跃法  磁共振血管造影
文章编号:1003-3289(2004)09-1437-03
修稿时间:2004年5月21日

Application of 3D TOF MRA of intracranial vessels with 3D K-space asymmetrically filled by the data in Kz axis
LIU Ding-xi,YU Qun,XIONG Yin,LIANG Ming,LIU Fang,KONG Xiang-quan,XU Hai-bo,SHI Hao-jun and DONG Dao-yu.Application of 3D TOF MRA of intracranial vessels with 3D K-space asymmetrically filled by the data in Kz axis[J].Chinese Journal of Medical Imaging Technology,2004,20(9):1437-1439.
Authors:LIU Ding-xi  YU Qun  XIONG Yin  LIANG Ming  LIU Fang  KONG Xiang-quan  XU Hai-bo  SHI Hao-jun and DONG Dao-yu
Institution:Department of Radiology, Xiehe Hospital, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430022, China;Department of Radiology, Xiehe Hospital, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430022, China;Department of Radiology, Xiehe Hospital, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430022, China;Department of Radiology, Xiehe Hospital, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430022, China;Department of Radiology, Xiehe Hospital, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430022, China;Department of Radiology, Xiehe Hospital, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430022, China;Department of Radiology, Xiehe Hospital, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430022, China;Department of Radiology, Xiehe Hospital, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430022, China;Department of Radiology, Xiehe Hospital, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430022, China
Abstract:Objective To investigate the value of 3D TOF MRA of intracranial vessels with K-space asymmetrically filled by the data in Kz axis. Methods Forty subjects underwent two kinds of 3D TOF MRA sequences with and without K-space asymmetrically filled by the data in Kz axis. On the source images and MIP images of these two sequences, the image quality,acquisition time,and the visualization of vessels were compared. Results Compared with those of routine method, 3D TOF MRA with K-space asymmetrically filled by the data in Kz axis showed significant difference in SNR, CNR,acquisition time, spatial resolution and vessel visualization ( P <0.01). Conclusion 3D TOF MRA with K-space asymmetrically filled by the data in Kz axis improves image quality and the visualization of intracranial vessels, and saves the acquisition time by 44%.
Keywords:K-space  Kz axis  Asymmetrically filled  Time of flight  Magnetic resonance angiography
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号