首页 | 本学科首页   官方微博 | 高级检索  
检索        

妇科超声影像报告和数据系统联合三维超声造影鉴别诊断卵巢良恶性肿块
引用本文:王霞丽,杨舒萍,吕国荣,廖建梅,张伟娜,吴淑芬.妇科超声影像报告和数据系统联合三维超声造影鉴别诊断卵巢良恶性肿块[J].中国医学影像技术,2018,34(6):888-892.
作者姓名:王霞丽  杨舒萍  吕国荣  廖建梅  张伟娜  吴淑芬
作者单位:福建医科大学附属漳州市医院超声医学科, 福建 漳州 363000;泉州医学高等专科学校临床系, 福建 泉州 362000,福建医科大学附属漳州市医院超声医学科, 福建 漳州 363000,福建医科大学附属漳州市医院超声医学科, 福建 漳州 363000;泉州医学高等专科学校临床系, 福建 泉州 362000;福建医科大学附属第二医院超声科, 福建 泉州 362000,福建医科大学附属漳州市医院超声医学科, 福建 漳州 363000,福建医科大学附属漳州市医院超声医学科, 福建 漳州 363000,福建医科大学附属漳州市医院超声医学科, 福建 漳州 363000
基金项目:福建省自然科学基金项目(2016J01649)。
摘    要:Objective To evaluate the efficacy of the combination of gynecologic imaging reporting and data system (GI-RADS) ultrasonographic stratification and 3D contrast-enhanced ultrasonography (3D-CEUS) in identifying malignant lesions from benign ovarian masses. Methods Both of 2D ultrasound (2D-US) and 3D-CEUS were performed on 102 patients with ovarian masses. The perfusion characteristics of ovarian masses were observed with 3D-CEUS,and the 2D-US features of ovarian masses were analyzed based on GI-RADS. Simple and multiple Logistic regression analysis were used to investigate whether the independent risk predictors in differential diagnosis of benign and malignant ovarian could be confirmed. In addition, ROC curves were drawn. The diagnostic efficacy of GI-RADS combined with 3D-CEUS scoring system was evaluated and compared with that of only GI-RADS. Results Simple and multiple Logistic regression analysis confirmed that there were 8 independent predictors of malignant masses, including large papillary projections (≥ 7 mm), separated or wall thickness ≥ 3 mm, central blood flow, the proportion of solid part ≥ 50%, combination of ascites, high level enhancement, uneven distribution of contrast media in enhanced solid part and the vascular with characteristics as dense, tortuous and anfractuous. When using 4 points as the cut-off, the area under the curve (AUC) of GI-RADS combined with 3D-CEUS scoring system in identifying malignant ovarian masses was 0.969, higher than that of only GI-RADS (0.839; Z=1.64, P=0.029). Furthermore, the scoring system showed higher sensitivity, specificity, positive predictive value, negative predictive value and accuracy (all P<0.001). Conclusion The combination of GI-RADS with 3D-CEUS can be more effective to distinguish malignant lesions from benign ovarian masses.

关 键 词:卵巢肿瘤  超声检查  成像  三维  妇科超声影像报告与数据系统
收稿时间:2017/7/21 0:00:00
修稿时间:2018/3/15 0:00:00

Gynecologic imaging reporting and data system combined with three-dimensional contrast-enhanced ultrasonography for differential diagnosis of benign and malignant ovarian masses
WANG Xiali,YANG Shuping,LYU Guorong,LIAO Jianmei,ZHANG Weina and WU Shufen.Gynecologic imaging reporting and data system combined with three-dimensional contrast-enhanced ultrasonography for differential diagnosis of benign and malignant ovarian masses[J].Chinese Journal of Medical Imaging Technology,2018,34(6):888-892.
Authors:WANG Xiali  YANG Shuping  LYU Guorong  LIAO Jianmei  ZHANG Weina and WU Shufen
Institution:Department of Ultrasound, Zhangzhou Affiliated Hospital of Fujian Medical University, Zhangzhou 363000, China;Department of Clinical Medicine, Quanzhou Medical College, Quanzhou 362000, China,Department of Ultrasound, Zhangzhou Affiliated Hospital of Fujian Medical University, Zhangzhou 363000, China,Department of Ultrasound, Zhangzhou Affiliated Hospital of Fujian Medical University, Zhangzhou 363000, China;Department of Clinical Medicine, Quanzhou Medical College, Quanzhou 362000, China;Department of Ultrasound, the Second Affiliated Hospital of Fujian Medical University, Quanzhou 362000, China,Department of Ultrasound, Zhangzhou Affiliated Hospital of Fujian Medical University, Zhangzhou 363000, China,Department of Ultrasound, Zhangzhou Affiliated Hospital of Fujian Medical University, Zhangzhou 363000, China and Department of Ultrasound, Zhangzhou Affiliated Hospital of Fujian Medical University, Zhangzhou 363000, China
Abstract:
Keywords:Ovarian neoplasms  Ultrasonography  Imaging  three-dimensional  Gynecologic imaging reporting and data system
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号