首页 | 本学科首页   官方微博 | 高级检索  
检索        

产前超声横断面连续扫查三血管气管上多切面诊断胎儿心血管异常
引用本文:林芸,张雪梅,冉素真,张晓航.产前超声横断面连续扫查三血管气管上多切面诊断胎儿心血管异常[J].中国医学影像技术,2019,35(5):725-729.
作者姓名:林芸  张雪梅  冉素真  张晓航
作者单位:重庆市妇幼保健院超声科, 重庆 400021,重庆市妇幼保健院超声科, 重庆 400021,重庆市妇幼保健院超声科, 重庆 400021,重庆市妇幼保健院超声科, 重庆 400021
摘    要:目的 探讨产前超声横断面连续扫查三血管气管上多切面诊断胎儿心血管异常的价值。方法 采用横断面连续扫查三血管气管上多切面方法,观察502胎正常胎儿和521胎异常胎儿的三血管气管上多切面声像图特点。结果 由三血管气管切面开始向胎儿头侧移动探头,依次获得三血管气管切面;头臂静脉切面可显示头臂静脉、主动脉横弓;头臂动脉起始段切面可显示头臂动脉、左颈总动脉、左锁骨下动脉起始段横断面;双侧锁骨下动静脉切面可显示双侧锁骨下动脉及双侧锁骨下静脉长轴、双侧颈总动脉起始段横断面。502胎正常胎儿三血管气管上多切面均可通过连续扫查获得显示。521胎异常胎儿中,三血管气管上多切面扫查检出头臂静脉异常236胎,头臂动脉异常277胎,心上型肺静脉异位引流7胎,颈位主动脉弓1胎。结论 三血管气管上多切面连续扫查有助于产前超声诊断胎儿心血管异常。

关 键 词:胎儿  超声心动描记术  三血管气管切面  头臂静脉  锁骨下动脉
收稿时间:2018/11/28 0:00:00
修稿时间:2019/3/4 0:00:00

Transverse continuous scanning on multiple sections above three vessels and trachea view in prenatal ultrasonic diagnosis of fetal cardiovascular anomalies
LIN Yun,ZHANG Xuemei,RAN Suzhen and ZHANG Xiaohang.Transverse continuous scanning on multiple sections above three vessels and trachea view in prenatal ultrasonic diagnosis of fetal cardiovascular anomalies[J].Chinese Journal of Medical Imaging Technology,2019,35(5):725-729.
Authors:LIN Yun  ZHANG Xuemei  RAN Suzhen and ZHANG Xiaohang
Institution:Department of Ultrasound, Chongqing Maternal and Child Health Hospital, Chongqing 400021, China,Department of Ultrasound, Chongqing Maternal and Child Health Hospital, Chongqing 400021, China,Department of Ultrasound, Chongqing Maternal and Child Health Hospital, Chongqing 400021, China and Department of Ultrasound, Chongqing Maternal and Child Health Hospital, Chongqing 400021, China
Abstract:Objective To explore the value of transverse continuous scanning on multiple sections above three vessels and trachea view in prenatal ultrasonic detection of fetal cardiovascular anomalies. Methods Using transverse continuous scanning on multiple sections above three vessels and trachea view, 502 normal fetus and 521 abnormal fetuses were observed, and ultrasonographic features of multiple sections above three vessels and trachea view were recorded. Results Four sections could be obtained by moving probe from the three-vessel tracheal section to the cephalic side of fetus. Section of three-vessel tracheal was firstly observed, then section of brachiocephalic vein which could show brachiocephalic vein and transverse aortic arch was screened, section of initial segment of brachiocephalic artery which could show the cross section planes of brachiocephalic artery, left common carotid artery and left subclavian artery was observed, and finally section of bilateral subclavian artery and subclavian vein which could show long axis planes of bilateral subclavian artery, bilateral subclavian vein and cross section of bilateral common carotid artery was screened. Multiple sections above three vessels and trachea view could be displayed by continuous scanning in all 502 normal fetuses. Among 521 ultrasonographic abnormal fetuses, 236 fetuses were found with abnormal brachiocephalic vein, 277 with abnormal brachiocephalic artery, 7 with abnormal pulmonary vein drainage at the heart and 1 with aortic arch at the neck. Conclusion Transverse continuous scanning sections above three vessels and tracheal view are helpful for prenatal ultrasonic diagnosis of fetal cardiovascular anomalies.
Keywords:fetus  echocardiography  three vessels and tracheal view  brachiocephalic veins  subclavian artery
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号